Skip to main content
Erschienen in: Clinical Research in Cardiology 8/2014

01.08.2014 | Critical Perspective

Contained aortic annulus rupture with persisting false aneurysm after transfemoral transcatheter aortic valve implantation

verfasst von: Stephanie Egenrieder, Stephan Hill, Maik Backes, Matthias Vöhringer, Udo Sechtem

Erschienen in: Clinical Research in Cardiology | Ausgabe 8/2014

Einloggen, um Zugang zu erhalten

Abstract

With older age and increasing comorbidities, conventional operative procedures for severe symptomatic aortic stenosis are associated with a high surgical risk. To date, transfemoral transcatheter aortic valve implantation (TF-TAVI) represents an accepted alternative method of intervention with a cardiovascular and all-cause mortality similar to operative replacement at early and long-term follow-up in this high risk population (Thomas et al., Circulation 124:425–433, 2011). Despite growing experience of the operators and improvement of the devices procedural and perioperative complications still occur (Panchal et al., Am J Cardiol, 2013). Aortic annulus rupture as well as the rupture of the membranous ventricular septum has been reported (Aminian et al., Catheter Cardiovasc Interv 81:E72–E75, 2013). We present the unusual case of an 80-year-old female who developed a false aneurysm following a contained aortic annulus rupture during a TF-TAVI procedure.
Literatur
1.
Zurück zum Zitat Aminian A, Lalmand J, Dolatabadi D (2013) Late contained aortic root rupture and ventricular septal defect after transcatheter aortic valve implantation. Catheter Cardiovasc Interv 81(1):E72–E75PubMedCrossRef Aminian A, Lalmand J, Dolatabadi D (2013) Late contained aortic root rupture and ventricular septal defect after transcatheter aortic valve implantation. Catheter Cardiovasc Interv 81(1):E72–E75PubMedCrossRef
2.
Zurück zum Zitat Blanke P, Reinöhl J, Schlensak C, Siepe M, Pache G, Euringer W, Geibel-Zehender A, Bode C, Langer M, Beyersdorf F, Zehender M (2012) Prothesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ CardiovascInterv 5(4):540–548CrossRef Blanke P, Reinöhl J, Schlensak C, Siepe M, Pache G, Euringer W, Geibel-Zehender A, Bode C, Langer M, Beyersdorf F, Zehender M (2012) Prothesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ CardiovascInterv 5(4):540–548CrossRef
3.
Zurück zum Zitat Panchal HB, Ladia V, Desai S, Shah T, Ramu V (2013) A meta-analysis of mortality and major adverse cardiovascular and cerebrovascular events following transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis. Am J Cardiol (published online) Panchal HB, Ladia V, Desai S, Shah T, Ramu V (2013) A meta-analysis of mortality and major adverse cardiovascular and cerebrovascular events following transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis. Am J Cardiol (published online)
4.
Zurück zum Zitat Thomas M, Schymik G, Walther T, Himbert D, Lefèvre T, Treede H, Eggebrecht H, Rubino P, Colombo A, Lange R, Schwarz RR, Wendler O (2011) One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 124(4):425–433PubMedCrossRef Thomas M, Schymik G, Walther T, Himbert D, Lefèvre T, Treede H, Eggebrecht H, Rubino P, Colombo A, Lange R, Schwarz RR, Wendler O (2011) One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 124(4):425–433PubMedCrossRef
Metadaten
Titel
Contained aortic annulus rupture with persisting false aneurysm after transfemoral transcatheter aortic valve implantation
verfasst von
Stephanie Egenrieder
Stephan Hill
Maik Backes
Matthias Vöhringer
Udo Sechtem
Publikationsdatum
01.08.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 8/2014
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-014-0696-0

Weitere Artikel der Ausgabe 8/2014

Clinical Research in Cardiology 8/2014 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.