Background

Correct sizing of the aortic annulus in aortic valve stenosis is crucial for successful transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) seems to be most promising imaging modality for this pre-interventional diagnostic work-up, but has the disadvantage of exposing mostly co-morbid patients to iodine and nephrotoxic contrast agents. To establish a useful sizing method for TAVI without the use of contrast media, we compared measurements of a non-contrast magnetic resonance imaging (MRI) technique with MSCT serving as the reference standard.

Methods

Fifty-two patients who underwent TAVI were previously examined with MSCT and MRI, respectively. MRI examination included a 3D steady-state free-precession sequence covering the entire ascending aorta. Perimeter and area of the aortic root were analyzed by two blinded readers in consensus using a dedicated software. Decisions for Sapien 3 valve size of both imaging modalities were compared using the mean derived annulus diameter.

Results

Mean age of the study cohort was 82.2 ± 4.9 years, log EuroScore was 25.2 ± 4.8 %. Mean aortic annulus perimeter as measured by MSCT was 76.7 ± 6.9 mm. MRI yielded a mean perimeter of 76.5 ± 6.7 mm with a good correlation coefficient (r = 0.93, p < 0.0001). Decision for valve size showed good correlation between both imaging modalities (r = 0.94, p < 0.0001).

Conclusion

In conclusion, non-contrast MRI shows good correlation to MSCT in the assessment of the aortic annulus and valve sizing. This non-contrast technique might be a reasonable alternative for aortic root sizing before TAVI without the use of nephrotoxic contrast agents, especially in patients with severely reduced kidney function.
Literatur
1.
Zurück zum Zitat Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP, Iung B, Otto CM, Pellikka PA, Quiñones M, American Society of Echocardiography; European Association of Echocardiography: Echocardiographic Assessment of Valve Stenosis: EAE/ASE (2009) Recommendations for clinical practice. J Am Soc Echocardiogr 22:1–23CrossRefPubMed Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP, Iung B, Otto CM, Pellikka PA, Quiñones M, American Society of Echocardiography; European Association of Echocardiography: Echocardiographic Assessment of Valve Stenosis: EAE/ASE (2009) Recommendations for clinical practice. J Am Soc Echocardiogr 22:1–23CrossRefPubMed
2.
Zurück zum Zitat Chin D (2009) Echocardiography for transcatheter aortic valve implantation. Eur J Echocardiogr 10:i21–i29CrossRefPubMed Chin D (2009) Echocardiography for transcatheter aortic valve implantation. Eur J Echocardiogr 10:i21–i29CrossRefPubMed
3.
Zurück zum Zitat Tops LF, Wood DA, Delegado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FP, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. J Am Coll Cardiol Imaging 1:321–330CrossRef Tops LF, Wood DA, Delegado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FP, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. J Am Coll Cardiol Imaging 1:321–330CrossRef
4.
Zurück zum Zitat Tzikas A, Schultz CJ, Piazza N, Moelker A, Van Mieghem NM, Nuis RJ, van Geuns RJ, Geleijnse ML, Serruys PW, de Jaegere PP (2011) Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and transthoracic echocardiography in patients referred for transcatheter aortic valve implantation. Catheter Cardiovasc Interv 77:868–875CrossRefPubMed Tzikas A, Schultz CJ, Piazza N, Moelker A, Van Mieghem NM, Nuis RJ, van Geuns RJ, Geleijnse ML, Serruys PW, de Jaegere PP (2011) Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and transthoracic echocardiography in patients referred for transcatheter aortic valve implantation. Catheter Cardiovasc Interv 77:868–875CrossRefPubMed
5.
Zurück zum Zitat Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, Neefjes LA, van Geuns RJ, de Feyter P, Krestin G, Serruys PW, de Jaegere PP (2010) Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer’s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 31:849–856CrossRefPubMed Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, Neefjes LA, van Geuns RJ, de Feyter P, Krestin G, Serruys PW, de Jaegere PP (2010) Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer’s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 31:849–856CrossRefPubMed
6.
Zurück zum Zitat Yamamoto M, Hayashida K, Mouillet G, Hovasse T, Chevalier B, Oquri A, Watanabe Y, Duboi-Randé JL, Morice MC, Lefèvre T, Teiger E (2013) Prognostic value of chronic kidney disease after transcatheter aortic valve implantation. J Am Coll Cardiol 62:869–877CrossRefPubMed Yamamoto M, Hayashida K, Mouillet G, Hovasse T, Chevalier B, Oquri A, Watanabe Y, Duboi-Randé JL, Morice MC, Lefèvre T, Teiger E (2013) Prognostic value of chronic kidney disease after transcatheter aortic valve implantation. J Am Coll Cardiol 62:869–877CrossRefPubMed
7.
Zurück zum Zitat Friedrich MG, Schulz-Menger J, Poetsch T, Pilz B, Uhlich F, Dietz R (2002) Quantification of valvular aortic stenosis by magnetic resonance imaging. Am Heart J 144:329–334CrossRefPubMed Friedrich MG, Schulz-Menger J, Poetsch T, Pilz B, Uhlich F, Dietz R (2002) Quantification of valvular aortic stenosis by magnetic resonance imaging. Am Heart J 144:329–334CrossRefPubMed
8.
Zurück zum Zitat Klass O, Walker MJ, Olszewski ME, Bahner J, Feuerlein S, Hoffmann MH, Lang A (2011) Quantification of aortic valve area at 256-slice computed tomography: comparison with transesophageal echocardiography and cardiac catheterization in subjects with high-grade aortic valve stenosis prior to percutaneous valve replacement. Eur J Radiol 80:151–157CrossRefPubMed Klass O, Walker MJ, Olszewski ME, Bahner J, Feuerlein S, Hoffmann MH, Lang A (2011) Quantification of aortic valve area at 256-slice computed tomography: comparison with transesophageal echocardiography and cardiac catheterization in subjects with high-grade aortic valve stenosis prior to percutaneous valve replacement. Eur J Radiol 80:151–157CrossRefPubMed
9.
Zurück zum Zitat La Manna A, Sanfilippo A, Capodanno D, Salemi A, Polizzi G, Deste W, Cincotta G, Cadoni A, Marchese A, Figuera M, Ussia GP, Pittalà R, Privitera C, Tamburino C (2011) Cardiovascular magnetic resonance fort he assessment of patients undergoing transcatheter aortic valve implantation: a pilot study. J Cardiovasc Magn Reson 13:82PubMedCentralCrossRefPubMed La Manna A, Sanfilippo A, Capodanno D, Salemi A, Polizzi G, Deste W, Cincotta G, Cadoni A, Marchese A, Figuera M, Ussia GP, Pittalà R, Privitera C, Tamburino C (2011) Cardiovascular magnetic resonance fort he assessment of patients undergoing transcatheter aortic valve implantation: a pilot study. J Cardiovasc Magn Reson 13:82PubMedCentralCrossRefPubMed
10.
Zurück zum Zitat Koos R, Altiok E, Mahnken AH, Neizel M, Dohmen G, Marx N, Kühl H, Hoffmann R (2012) Evaluation of aortic root for definition of prosthesis size by magnetic resonance imaging and cardiac computed tomography: implications for transcatheter aortic valve implantation. Int J Cardiol 158:353–358CrossRefPubMed Koos R, Altiok E, Mahnken AH, Neizel M, Dohmen G, Marx N, Kühl H, Hoffmann R (2012) Evaluation of aortic root for definition of prosthesis size by magnetic resonance imaging and cardiac computed tomography: implications for transcatheter aortic valve implantation. Int J Cardiol 158:353–358CrossRefPubMed
11.
Zurück zum Zitat Jabbour A, Ismail TF, Moat N, Gulati A, Roussin I, Alpendurada F, Park B, Okoroafor F, Asgar A, Barker S, Davies S, Prasad SK, Rubens M, Mohiaddin RH (2011) Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J Am Coll Cardiol 58:2165–2173CrossRefPubMed Jabbour A, Ismail TF, Moat N, Gulati A, Roussin I, Alpendurada F, Park B, Okoroafor F, Asgar A, Barker S, Davies S, Prasad SK, Rubens M, Mohiaddin RH (2011) Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J Am Coll Cardiol 58:2165–2173CrossRefPubMed
12.
Zurück zum Zitat Morita S, Masukawa A, Suzuki K, Hirata M, Kojima S, Ueno E (2011) Unenhanced MR angiography: techniques and clinical applications in patients with chronic kidney disease. Radiographics 31:E13–E33CrossRefPubMed Morita S, Masukawa A, Suzuki K, Hirata M, Kojima S, Ueno E (2011) Unenhanced MR angiography: techniques and clinical applications in patients with chronic kidney disease. Radiographics 31:E13–E33CrossRefPubMed
13.
Zurück zum Zitat Krishnam MS, Tomasian A, Malik S, Desphande V, Laub G, Ruehm SG (2010) Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic disease. Eur Radiol 20:1311–1320PubMedCentralCrossRefPubMed Krishnam MS, Tomasian A, Malik S, Desphande V, Laub G, Ruehm SG (2010) Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic disease. Eur Radiol 20:1311–1320PubMedCentralCrossRefPubMed
14.
Zurück zum Zitat Levey AS, Bosch JP, Lewis JB, Greene T, Rogers N, Roth D, for the Modification of Diet in Renal Disease Study Group (1999) A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med 130:461–470CrossRefPubMed Levey AS, Bosch JP, Lewis JB, Greene T, Rogers N, Roth D, for the Modification of Diet in Renal Disease Study Group (1999) A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med 130:461–470CrossRefPubMed
15.
Zurück zum Zitat Wöhrle J, von Scheidt F, Schauwecker P, Wiesneth M, Markovic S, Schrezenmeier H, Hombach V, Rottbauer W, Bernhardt P (2013) Impact of cell number and microvascular obstruction in patients with bone-marrow derived cell therapy: final results from the randomized, double-blind, placebo controlled intracoronary Stem Cell therapy in patients with Acute Myocardial Infarction (SCAMI) trial. Clin Res Cardiol 102:1295–1301CrossRef Wöhrle J, von Scheidt F, Schauwecker P, Wiesneth M, Markovic S, Schrezenmeier H, Hombach V, Rottbauer W, Bernhardt P (2013) Impact of cell number and microvascular obstruction in patients with bone-marrow derived cell therapy: final results from the randomized, double-blind, placebo controlled intracoronary Stem Cell therapy in patients with Acute Myocardial Infarction (SCAMI) trial. Clin Res Cardiol 102:1295–1301CrossRef
16.
Zurück zum Zitat Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1:74–81CrossRefPubMed Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1:74–81CrossRefPubMed
17.
Zurück zum Zitat Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A, Sengupta PP (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6:249–262CrossRefPubMed Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A, Sengupta PP (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6:249–262CrossRefPubMed
18.
Zurück zum Zitat Šmíd M, Ferda J, Baxa J, Čech J, Hájek T, Kreuzberg B, Rokyta R (2010) Aortic annulus and ascending aorta: comparison of preoperative and perioperative measurement in patients with aortic stenosis. Eur J Radiol 74:152–155CrossRefPubMed Šmíd M, Ferda J, Baxa J, Čech J, Hájek T, Kreuzberg B, Rokyta R (2010) Aortic annulus and ascending aorta: comparison of preoperative and perioperative measurement in patients with aortic stenosis. Eur J Radiol 74:152–155CrossRefPubMed
19.
20.
Zurück zum Zitat Rihal CS, Textor SC, Grill DE, Bernger PB, Ting HH, Best PJ, Singh M, Bell MR, Barsness GW, Mathew V, Garrat KN, Holmes DR Jr (2002) Incidence and prognostic importance of acute renal failure after percutaneous coronary intervention. Circulation 105:2259–2264CrossRefPubMed Rihal CS, Textor SC, Grill DE, Bernger PB, Ting HH, Best PJ, Singh M, Bell MR, Barsness GW, Mathew V, Garrat KN, Holmes DR Jr (2002) Incidence and prognostic importance of acute renal failure after percutaneous coronary intervention. Circulation 105:2259–2264CrossRefPubMed
21.
Zurück zum Zitat Diaz-Sandoval LJ, Kosowsky BD, Losordo DW (2002) Acetylcysteine to prevent angiography-related renal tissue injury (the APART trial). Am J Cardiol 89:356–358CrossRefPubMed Diaz-Sandoval LJ, Kosowsky BD, Losordo DW (2002) Acetylcysteine to prevent angiography-related renal tissue injury (the APART trial). Am J Cardiol 89:356–358CrossRefPubMed
22.
Zurück zum Zitat Durham JD, Caputo C, Dokko J, Zaharakis T, Pahlavan M, Keltz J, Dutka P, Marzo K, Maesaka JK, Fishbane S (2002) A randomized controlled trial of N-acetylcysteine to prevent contrast nephropathy in cardiac angiography. Kidney Int 62:2202–2207CrossRefPubMed Durham JD, Caputo C, Dokko J, Zaharakis T, Pahlavan M, Keltz J, Dutka P, Marzo K, Maesaka JK, Fishbane S (2002) A randomized controlled trial of N-acetylcysteine to prevent contrast nephropathy in cardiac angiography. Kidney Int 62:2202–2207CrossRefPubMed
23.
Zurück zum Zitat Aregger F, Wenaweser P, Hellige GJ, Kadner A, Carrel T, Windecker S, Frey FJ (2009) Risk of acute kidney injury in patients with severe aortic valve stenosis undergoing transcatheter valve replacement. Nephrol Dial Transplant 24:2175–2179CrossRefPubMed Aregger F, Wenaweser P, Hellige GJ, Kadner A, Carrel T, Windecker S, Frey FJ (2009) Risk of acute kidney injury in patients with severe aortic valve stenosis undergoing transcatheter valve replacement. Nephrol Dial Transplant 24:2175–2179CrossRefPubMed
24.
Zurück zum Zitat Wöhrle J, Gonska B, Rodewald C, Trepte U, Koch S, Scharnbeck D, Seeger J, Markovic S, Rottbauer W (2015) Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve. Int J Cardiol 195:171–175CrossRefPubMed Wöhrle J, Gonska B, Rodewald C, Trepte U, Koch S, Scharnbeck D, Seeger J, Markovic S, Rottbauer W (2015) Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve. Int J Cardiol 195:171–175CrossRefPubMed
25.
Zurück zum Zitat Deo A, Fogel M, Cowper SE (2007) Nephrogenic systemic fibrosis: a population study examining the relationship of disease development to gadolinium exposure. Clin J Am Soc Nephrol 2:264–267CrossRefPubMed Deo A, Fogel M, Cowper SE (2007) Nephrogenic systemic fibrosis: a population study examining the relationship of disease development to gadolinium exposure. Clin J Am Soc Nephrol 2:264–267CrossRefPubMed
26.
Zurück zum Zitat Chien CC, Wang HY, Wang JJ, Kan WC, Chien TW, Lin XY, Su SB (2011) Risk of acute kidney injury after exposure to gadolinium-based contrast in patients with renal impairment. Ren Fail 33:758–764CrossRefPubMed Chien CC, Wang HY, Wang JJ, Kan WC, Chien TW, Lin XY, Su SB (2011) Risk of acute kidney injury after exposure to gadolinium-based contrast in patients with renal impairment. Ren Fail 33:758–764CrossRefPubMed
Metadaten
Titel
Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation
verfasst von
Peter Bernhardt
Christoph Rodewald
Julia Seeger
Birgid Gonska
Dominik Buckert
Michael Radermacher
Vinzenz Hombach
Wolfgang Rottbauer
Jochen Wöhrle
Publikationsdatum
01.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 3/2016
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-015-0920-6

Weitere Artikel der Ausgabe 3/2016

Clinical Research in Cardiology 3/2016 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.