Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 5/2013

01.10.2013 | Original Article

Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly

verfasst von: A. El Saman, S. Meier, A. Sander, A. Kelm, I. Marzi, H. Laurer

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 5/2013

Einloggen, um Zugang zu erhalten

Abstract

Background

Therapy of vertebral fractures in the elderly is a growing challenge for surgeons. Within the last two decades, the use of polymethylmethacrylate (PMMA) in the treatment of osteoporotic vertebral fractures has been widely established. Besides vertebroplasty and kyphoplasty, the augmentation of pedicle screws with PMMA found widespread use to strengthen the implant–bone interface. Several studies showed an enhanced pullout strength of augmented screws compared to standard pedicle screws in osteoporotic bone models. To validate the clinical relevance, we analyzed postoperative radiologic follow-up data in regard to secondary loss of correction and loosening of pedicle screws in elderly patients.

Materials and methods

In this retrospective comparative study, 24 patients admitted to our level I trauma center were analyzed concerning screw loosening and secondary loss of correction following vertebral fracture and posterior instrumentation. Loss of correction was determined by the bisegmental Cobb angle and kyphosis angle of the fractured vertebra. Follow-up computed tomography (CT) scans were used to analyze the prevalence of clear zones around the pedicle screws as a sign of loosening.

Results

In 15 patients (mean age 76 ± 9.3 years) with 117 PMMA-augmented pedicle screws, 4.3 % of screws showed signs of loosening, whereas in nine patients (mean age 75 ± 8.2 years) with 86 uncemented screws, the loosening rate was 62.8 %. Thus, PMMA-augmented pedicle screws showed a significantly lower loosening rate compared to regular pedicle screws. Loss of correction was minimal, despite poor bone quality. There was significantly less loss of correction in patients with augmented pedicle screws (1.1° ± 0.8°) as compared to patients without augmentation (5° ± 3.8°).

Conclusion

The reinforcement of pedicle screws using PMMA augmentation may be a viable option in the surgical treatment of spinal fractures in the elderly.
Literatur
1.
Zurück zum Zitat Eysel P, Meinig G. Comparative study of different dorsal stabilization techniques in recent thoraco-lumbar spine fractures. Acta Neurochir (Wien). 1991;109(1–2):12–9.CrossRef Eysel P, Meinig G. Comparative study of different dorsal stabilization techniques in recent thoraco-lumbar spine fractures. Acta Neurochir (Wien). 1991;109(1–2):12–9.CrossRef
2.
Zurück zum Zitat Knop C, Blauth M, Bastian L, Lange U, Kesting J, Tscherne H. Fractures of the thoracolumbar spine. Late results of dorsal instrumentation and its consequences. Unfallchirurg. 1997;100(8):630–9.PubMedCrossRef Knop C, Blauth M, Bastian L, Lange U, Kesting J, Tscherne H. Fractures of the thoracolumbar spine. Late results of dorsal instrumentation and its consequences. Unfallchirurg. 1997;100(8):630–9.PubMedCrossRef
3.
Zurück zum Zitat Knop C, Blauth M, Bühren V, Arand M, Egbers HJ, Hax PM, et al. Surgical treatment of injuries of the thoracolumbar transition—3: follow-up examination. Results of a prospective multi-center study by the “Spinal” Study Group of the German Society of Trauma Surgery. Unfallchirurg. 2001;104(7):583–600.PubMedCrossRef Knop C, Blauth M, Bühren V, Arand M, Egbers HJ, Hax PM, et al. Surgical treatment of injuries of the thoracolumbar transition—3: follow-up examination. Results of a prospective multi-center study by the “Spinal” Study Group of the German Society of Trauma Surgery. Unfallchirurg. 2001;104(7):583–600.PubMedCrossRef
4.
Zurück zum Zitat Knop C, Blauth M, Bühren V, Hax PM, Kinzl L, Mutschler W, et al. Surgical treatment of injuries of the thoracolumbar transition. 1: epidemiology. Unfallchirurg. 1999;102(12):924–35.PubMedCrossRef Knop C, Blauth M, Bühren V, Hax PM, Kinzl L, Mutschler W, et al. Surgical treatment of injuries of the thoracolumbar transition. 1: epidemiology. Unfallchirurg. 1999;102(12):924–35.PubMedCrossRef
5.
Zurück zum Zitat Knop C, Blauth M, Bühren V, Hax PM, Kinzl L, Mutschler W, et al. Surgical treatment of injuries of the thoracolumbar transition. 2: operation and roentgenologic findings. Unfallchirurg. 2000;103(12):1032–47.PubMedCrossRef Knop C, Blauth M, Bühren V, Hax PM, Kinzl L, Mutschler W, et al. Surgical treatment of injuries of the thoracolumbar transition. 2: operation and roentgenologic findings. Unfallchirurg. 2000;103(12):1032–47.PubMedCrossRef
6.
Zurück zum Zitat Knop C, Fabian HF, Bastian L, Blauth M. Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting. Spine (Phila Pa 1976). 2001;26(1):88–99.CrossRef Knop C, Fabian HF, Bastian L, Blauth M. Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting. Spine (Phila Pa 1976). 2001;26(1):88–99.CrossRef
7.
Zurück zum Zitat Lindsey RW, Dick W. The fixateur interne in the reduction and stabilization of thoracolumbar spine fractures in patients with neurologic deficit. Spine (Phila Pa 1976). 1991;16(3 Suppl):S140–5.CrossRef Lindsey RW, Dick W. The fixateur interne in the reduction and stabilization of thoracolumbar spine fractures in patients with neurologic deficit. Spine (Phila Pa 1976). 1991;16(3 Suppl):S140–5.CrossRef
8.
Zurück zum Zitat Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of traumatic fractures of the thoracic and lumbar spinal column: part III: follow up data. Unfallchirurg. 2009;112(3):294–316. doi:10.1007/s00113-008-1539-0.PubMedCrossRef Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of traumatic fractures of the thoracic and lumbar spinal column: part III: follow up data. Unfallchirurg. 2009;112(3):294–316. doi:10.​1007/​s00113-008-1539-0.PubMedCrossRef
9.
Zurück zum Zitat Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of traumatic fractures of the thorax and lumbar spine. Part II: surgical treatment and radiological findings. Unfallchirurg. 2009;112(2):149–67. doi:10.1007/s00113-008-1538-1.PubMedCrossRef Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of traumatic fractures of the thorax and lumbar spine. Part II: surgical treatment and radiological findings. Unfallchirurg. 2009;112(2):149–67. doi:10.​1007/​s00113-008-1538-1.PubMedCrossRef
10.
Zurück zum Zitat Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of traumatic fractures of the thoracic and lumbar spinal column. Part I: epidemiology. Unfallchirurg. 2009; 112(1):33–42, 44–5. doi:10.1007/s00113-008-1524-7.PubMedCrossRef Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of traumatic fractures of the thoracic and lumbar spinal column. Part I: epidemiology. Unfallchirurg. 2009; 112(1):33–42, 44–5. doi:10.​1007/​s00113-008-1524-7.PubMedCrossRef
11.
Zurück zum Zitat Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of 733 patients with acute thoracolumbar spinal injuries: comprehensive results from the second, prospective, Internet-based multicenter study of the Spine Study Group of the German Association of Trauma Surgery. Eur Spine J. 2010;19(10):1657–76. doi:10.1007/s00586-010-1451-5.PubMedCrossRef Reinhold M, Knop C, Beisse R, Audigé L, Kandziora F, Pizanis A, et al. Operative treatment of 733 patients with acute thoracolumbar spinal injuries: comprehensive results from the second, prospective, Internet-based multicenter study of the Spine Study Group of the German Association of Trauma Surgery. Eur Spine J. 2010;19(10):1657–76. doi:10.​1007/​s00586-010-1451-5.PubMedCrossRef
13.
Zurück zum Zitat Magerl F, Aebi M, Gertzbein SD, Harms J, Nazarian S. A comprehensive classification of thoracic and lumbar injuries. Eur Spine J. 1994;3(4):184–201.PubMedCrossRef Magerl F, Aebi M, Gertzbein SD, Harms J, Nazarian S. A comprehensive classification of thoracic and lumbar injuries. Eur Spine J. 1994;3(4):184–201.PubMedCrossRef
14.
Zurück zum Zitat Isenberg J, Jubel A, Hahn U, Seifert H, Prokop A. Multistep surgery for spondylosyndesis. Treatment concept of destructive spondylodiscitis in patients with reduced general condition. Orthopade. 2005;34(2):159–66. doi:10.1007/s00132-004-0722-4.PubMedCrossRef Isenberg J, Jubel A, Hahn U, Seifert H, Prokop A. Multistep surgery for spondylosyndesis. Treatment concept of destructive spondylodiscitis in patients with reduced general condition. Orthopade. 2005;34(2):159–66. doi:10.​1007/​s00132-004-0722-4.PubMedCrossRef
15.
Zurück zum Zitat Amendola L, Gasbarrini A, Fosco M, Simoes CE, Terzi S, De Iure F, et al. Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases. J Orthop Traumatol. 2011;12(4):193–9. doi:10.1007/s10195-011-0164-9.PubMedCrossRef Amendola L, Gasbarrini A, Fosco M, Simoes CE, Terzi S, De Iure F, et al. Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases. J Orthop Traumatol. 2011;12(4):193–9. doi:10.​1007/​s10195-011-0164-9.PubMedCrossRef
16.
Zurück zum Zitat Blattert TR, Glasmacher S, Riesner HJ, Josten C. Revision characteristics of cement-augmented, cannulated–fenestrated pedicle screws in the osteoporotic vertebral body: a biomechanical in vitro investigation. Technical note. J Neurosurg Spine. 2009;11(1):23–7. doi:10.3171/2009.3.SPINE08625.PubMedCrossRef Blattert TR, Glasmacher S, Riesner HJ, Josten C. Revision characteristics of cement-augmented, cannulated–fenestrated pedicle screws in the osteoporotic vertebral body: a biomechanical in vitro investigation. Technical note. J Neurosurg Spine. 2009;11(1):23–7. doi:10.​3171/​2009.​3.​SPINE08625.PubMedCrossRef
18.
Zurück zum Zitat Bullmann V, Schmoelz W, Richter M, Grathwohl C, Schulte TL. Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers. Spine (Phila Pa 1976). 2010;35(19):E932–9. doi:10.1097/BRS.0b013e3181c6ec60.CrossRef Bullmann V, Schmoelz W, Richter M, Grathwohl C, Schulte TL. Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers. Spine (Phila Pa 1976). 2010;35(19):E932–9. doi:10.​1097/​BRS.​0b013e3181c6ec60​.CrossRef
20.
Zurück zum Zitat Lubansu A, Rynkowski M, Abeloos L, Appelboom G, Dewitte O. Minimally invasive spinal arthrodesis in osteoporotic population using a cannulated and fenestrated augmented screw: technical description and clinical experience. Minim Invasive Surg. 2012;2012:507826. doi:10.1155/2012/507826.PubMed Lubansu A, Rynkowski M, Abeloos L, Appelboom G, Dewitte O. Minimally invasive spinal arthrodesis in osteoporotic population using a cannulated and fenestrated augmented screw: technical description and clinical experience. Minim Invasive Surg. 2012;2012:507826. doi:10.​1155/​2012/​507826.PubMed
21.
Zurück zum Zitat Paré PE, Chappuis JL, Rampersaud R, Agarwala AO, Perra JH, Erkan S, et al. Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines. Spine (Phila Pa 1976). 2011;36(18):E1210–4. doi:10.1097/BRS.0b013e318205e3af.CrossRef Paré PE, Chappuis JL, Rampersaud R, Agarwala AO, Perra JH, Erkan S, et al. Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines. Spine (Phila Pa 1976). 2011;36(18):E1210–4. doi:10.​1097/​BRS.​0b013e318205e3af​.CrossRef
22.
27.
Zurück zum Zitat Röllinghoff M, Siewe J, Eysel P, Delank KS. Pulmonary cement embolism after augmentation of pedicle screws with bone cement. Acta Orthop Belg. 2010;76(2):269–73.PubMed Röllinghoff M, Siewe J, Eysel P, Delank KS. Pulmonary cement embolism after augmentation of pedicle screws with bone cement. Acta Orthop Belg. 2010;76(2):269–73.PubMed
30.
Zurück zum Zitat Temple JD, Ludwig SC, Ross WK, Marshall WK, Larsen L, Gelb DE. Catastrophic fat embolism following augmentation of pedicle screws with bone cement: a case report. J Bone Joint Surg Am. 2002;84-A(4):639–42.PubMed Temple JD, Ludwig SC, Ross WK, Marshall WK, Larsen L, Gelb DE. Catastrophic fat embolism following augmentation of pedicle screws with bone cement: a case report. J Bone Joint Surg Am. 2002;84-A(4):639–42.PubMed
31.
Zurück zum Zitat Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW. Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br. 2003;85(1):83–9.PubMedCrossRef Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW. Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br. 2003;85(1):83–9.PubMedCrossRef
Metadaten
Titel
Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly
verfasst von
A. El Saman
S. Meier
A. Sander
A. Kelm
I. Marzi
H. Laurer
Publikationsdatum
01.10.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 5/2013
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-013-0310-6

Weitere Artikel der Ausgabe 5/2013

European Journal of Trauma and Emergency Surgery 5/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.