Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 2/2011

01.04.2011 | Review Article

3D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screws

verfasst von: J.-S. Jarvers, S. Katscher, A. Franck, S. Glasmacher, C. Schmidt, T. Blattert, C. Josten

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 2/2011

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Navigated procedures in spinal surgery have been established due to an increasing demand for precision. Especially, 3D C-arms connected to navigation systems are being used more often and can be utilised intraoperatively for the planning and controlling of screw positions. This prospective study analyses our experiences with 3D-based navigation in posterior stabilisations in the cervical and thoracic spine.

Methods

A 3D C-Arm (Ziehm Vision Vario 3D®) was connected to a navigation system (VectorVision, Brainlab®) and used for the placement of, in total, 451 screws among 67 patients. Of those, 14 patients had to undergo operations in the cervical and 53 in the thoracic spine. Postoperatively, the positioning was observed with computed tomography (CT).

Results

The application time is approximately 6 min. In total, 354/451 (78.5%) screws could be inserted assisted with navigation, and 272/451 (60.3%) were controlled intraoperatively. Regarding the cervical spine, in 87.1% (61/70) of the screws, the navigation procedure was uneventful. The positioning of 63.2% (43/68) of the screws was checked intraoperatively. In the upper thoracic spine, 77% (293/381) could be placed with navigation and 59.6% (227/381) were controlled intraoperatively. Occasionally, the scanning setup was problematic. Correct placement was seen in 92.7% of screws; for the remaining screws, no revision was needed.

Conclusions

Intraoperative 3D imaging navigation for posterior spinal stabilisations is technically feasible and reliable in clinical use. The image quality depends on the individual bone density. With undisturbed visibility of the vertebral body, the reliability of 3D-based navigation is comparable to that of CT-based procedures. Additionally, it has the advantage of skipping the preoperative acquisition of data as well as the matching process, with reduced radiation doses.
Literatur
1.
Zurück zum Zitat Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Accuracy of pedicle screw placement in lumbar vertebrae. Spine. 1996;21:1320–4. PubMedCrossRef Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Accuracy of pedicle screw placement in lumbar vertebrae. Spine. 1996;21:1320–4. PubMedCrossRef
2.
Zurück zum Zitat Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J. 2000;9:235–40. PubMedCrossRef Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J. 2000;9:235–40. PubMedCrossRef
3.
Zurück zum Zitat Schulze CJ, Munzinger E, Weber U. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine. 1998;23:2215–20. PubMedCrossRef Schulze CJ, Munzinger E, Weber U. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine. 1998;23:2215–20. PubMedCrossRef
4.
Zurück zum Zitat Neo M, Sakamoto T, Fujibayashi S, Nakamura T. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine. 2005;30:2800–5. PubMedCrossRef Neo M, Sakamoto T, Fujibayashi S, Nakamura T. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine. 2005;30:2800–5. PubMedCrossRef
5.
Zurück zum Zitat Jones EL, Heller JG, Silcox DH, Hutton WC. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine. 1997;22:977–82. PubMedCrossRef Jones EL, Heller JG, Silcox DH, Hutton WC. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine. 1997;22:977–82. PubMedCrossRef
6.
Zurück zum Zitat Karaikovic EE, Daubs MD, Madsen RW, Gaines RW Jr. Morphologic characteristics of human cervical pedicles. Spine. 1997;22:493–500. PubMedCrossRef Karaikovic EE, Daubs MD, Madsen RW, Gaines RW Jr. Morphologic characteristics of human cervical pedicles. Spine. 1997;22:493–500. PubMedCrossRef
7.
Zurück zum Zitat Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ. Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine. 2000;25:1655–67. PubMedCrossRef Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ. Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine. 2000;25:1655–67. PubMedCrossRef
8.
Zurück zum Zitat Panjabi MM, Shin EK, Chen NC, Wang JL. Internal morphology of human cervical pedicles. Spine. 2000;25:1197–205. PubMedCrossRef Panjabi MM, Shin EK, Chen NC, Wang JL. Internal morphology of human cervical pedicles. Spine. 2000;25:1197–205. PubMedCrossRef
9.
Zurück zum Zitat Sakamoto T, Neo M, Nakamura T. Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine. 2004;29:2510–5. PubMedCrossRef Sakamoto T, Neo M, Nakamura T. Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine. 2004;29:2510–5. PubMedCrossRef
10.
11.
Zurück zum Zitat Ito H, Neo M, Yoshida M, Fujibayashi S, Yoshitomi H, Nakamura T. Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. Rheumatol Int. 2007;27:567–74. PubMedCrossRef Ito H, Neo M, Yoshida M, Fujibayashi S, Yoshitomi H, Nakamura T. Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. Rheumatol Int. 2007;27:567–74. PubMedCrossRef
12.
Zurück zum Zitat Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K. Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord. 2000;13:218–24. PubMedCrossRef Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K. Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord. 2000;13:218–24. PubMedCrossRef
13.
Zurück zum Zitat Kotani Y, Abumi K, Ito M, Minami A. Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg. 2003;99(3 Suppl):257–63. PubMed Kotani Y, Abumi K, Ito M, Minami A. Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg. 2003;99(3 Suppl):257–63. PubMed
14.
Zurück zum Zitat Laine T, Schlenzka D, Mäkitalo K, Tallroth K, Nolte LP, Visarius H. Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine. 1997;22:1254–8. PubMedCrossRef Laine T, Schlenzka D, Mäkitalo K, Tallroth K, Nolte LP, Visarius H. Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine. 1997;22:1254–8. PubMedCrossRef
15.
Zurück zum Zitat Rampersaud YR, Pik JH, Salonen D, Farooq S. Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine. 2005;30:E183–90. PubMedCrossRef Rampersaud YR, Pik JH, Salonen D, Farooq S. Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine. 2005;30:E183–90. PubMedCrossRef
16.
Zurück zum Zitat Richter M, Cakir B, Schmidt R. Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine. 2005;30:2280–7. PubMedCrossRef Richter M, Cakir B, Schmidt R. Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine. 2005;30:2280–7. PubMedCrossRef
17.
Zurück zum Zitat Takahashi J, Shono Y, Nakamura I, Hirabayashi H, Kamimura M, Ebara S, Kato H. Computer-assisted screw insertion for cervical disorders in rheumatoid arthritis. Eur Spine J. 2007;16:485–94. PubMedCrossRef Takahashi J, Shono Y, Nakamura I, Hirabayashi H, Kamimura M, Ebara S, Kato H. Computer-assisted screw insertion for cervical disorders in rheumatoid arthritis. Eur Spine J. 2007;16:485–94. PubMedCrossRef
18.
Zurück zum Zitat Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, Papadopoulos SM. Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery. 2004;54:1131–7. PubMedCrossRef Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, Papadopoulos SM. Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery. 2004;54:1131–7. PubMedCrossRef
19.
Zurück zum Zitat Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S. Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine. 2010;13:606–11. PubMedCrossRef Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S. Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine. 2010;13:606–11. PubMedCrossRef
20.
Zurück zum Zitat Rajasekaran S, Vidyadhara S, Shetty AP. Iso-C3D fluoroscopy-based navigation in direct pedicle screw fixation of Hangman fracture: a case report. J Spinal Disord Tech. 2007;20:616–9. PubMedCrossRef Rajasekaran S, Vidyadhara S, Shetty AP. Iso-C3D fluoroscopy-based navigation in direct pedicle screw fixation of Hangman fracture: a case report. J Spinal Disord Tech. 2007;20:616–9. PubMedCrossRef
21.
Zurück zum Zitat Stübig T, Kendoff D, Citak M, Geerling J, Khalafi A, Krettek C, Hüfner T. Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care. J Trauma. 2009;66:821–30. PubMedCrossRef Stübig T, Kendoff D, Citak M, Geerling J, Khalafi A, Krettek C, Hüfner T. Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care. J Trauma. 2009;66:821–30. PubMedCrossRef
22.
Zurück zum Zitat Glossop N, Hu R. Assessment of vertebral body motion during spine surgery. Spine. 1997;22:903–9. PubMedCrossRef Glossop N, Hu R. Assessment of vertebral body motion during spine surgery. Spine. 1997;22:903–9. PubMedCrossRef
23.
Zurück zum Zitat Grützner PA, Beutler T, Wendl K, von Recum J, Wentzensen A, Nolte LP. Intraoperative three-dimensional navigation for pedicle screw placement. Chirurg. 2004;75:967–75. PubMedCrossRef Grützner PA, Beutler T, Wendl K, von Recum J, Wentzensen A, Nolte LP. Intraoperative three-dimensional navigation for pedicle screw placement. Chirurg. 2004;75:967–75. PubMedCrossRef
24.
Zurück zum Zitat Dvorak M, MacDonald S, Gurr KR, Bailey SI, Haddad RG. An anatomic, radiographic, and biomechanical assessment of extrapedicular screw fixation in the thoracic spine. Spine. 1993;18(12):1689–94. PubMedCrossRef Dvorak M, MacDonald S, Gurr KR, Bailey SI, Haddad RG. An anatomic, radiographic, and biomechanical assessment of extrapedicular screw fixation in the thoracic spine. Spine. 1993;18(12):1689–94. PubMedCrossRef
25.
Zurück zum Zitat Morgenstern W, Ferguson SJ, Berey S, Orr TE, Nolte LP. Posterior thoracic extrapedicular fixation: a biomechanical study. Spine. 2003;28:1829–35. PubMedCrossRef Morgenstern W, Ferguson SJ, Berey S, Orr TE, Nolte LP. Posterior thoracic extrapedicular fixation: a biomechanical study. Spine. 2003;28:1829–35. PubMedCrossRef
26.
Zurück zum Zitat Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine. 1993;18:2231–8. PubMedCrossRef Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine. 1993;18:2231–8. PubMedCrossRef
27.
Zurück zum Zitat Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine. 2007;32:E111–20. PubMedCrossRef Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine. 2007;32:E111–20. PubMedCrossRef
28.
Zurück zum Zitat Amniot LP, Lang K, Putzier M, Zippel H, Labelle H. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine. 2000;25:606–14. PubMedCrossRef Amniot LP, Lang K, Putzier M, Zippel H, Labelle H. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine. 2000;25:606–14. PubMedCrossRef
29.
Zurück zum Zitat Abumi K, Itoh H, Taneichi H, Kaneda K. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord. 1994;7:19–28. PubMedCrossRef Abumi K, Itoh H, Taneichi H, Kaneda K. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord. 1994;7:19–28. PubMedCrossRef
30.
Zurück zum Zitat Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M. Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine. 2006;31(17):2024–7. PubMedCrossRef Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M. Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine. 2006;31(17):2024–7. PubMedCrossRef
31.
Zurück zum Zitat Gebhard F, Banckwitz R, Kraus M. Intraoperative ionising radiation in 3D-based computer-navigated procedures vs. 2D fluoroscopy. An experimental comparison. Trauma Berufskrankh. 2009;11:162–6. CrossRef Gebhard F, Banckwitz R, Kraus M. Intraoperative ionising radiation in 3D-based computer-navigated procedures vs. 2D fluoroscopy. An experimental comparison. Trauma Berufskrankh. 2009;11:162–6. CrossRef
32.
Zurück zum Zitat van Walsum T, van de Kraats EB, Voormolen MHJ, Verlaan JJ, Mali WP, Niessen WJ. Navigation with three-dimensional rotational radiographic data for transpedicular percutaneous needle introduction: feasibility and comparison with fluoroscopic guidance. J Vasc Interv Radiol. 2006;17:1511–8. PubMedCrossRef van Walsum T, van de Kraats EB, Voormolen MHJ, Verlaan JJ, Mali WP, Niessen WJ. Navigation with three-dimensional rotational radiographic data for transpedicular percutaneous needle introduction: feasibility and comparison with fluoroscopic guidance. J Vasc Interv Radiol. 2006;17:1511–8. PubMedCrossRef
33.
Zurück zum Zitat Stöckle U, Schäffler A, König B, Haas NP. Integrated navigation. Preclinical evaluation and initial clinical experience. Unfallchirurg. 2006;109:925–31. PubMedCrossRef Stöckle U, Schäffler A, König B, Haas NP. Integrated navigation. Preclinical evaluation and initial clinical experience. Unfallchirurg. 2006;109:925–31. PubMedCrossRef
34.
Zurück zum Zitat Hüfner T, Stübig T, Gösling T, Kendoff D, Geerling J, Krettek C. Cost–benefit analysis of intraoperative 3D imaging. Unfallchirurg. 2007;110:14–21. PubMedCrossRef Hüfner T, Stübig T, Gösling T, Kendoff D, Geerling J, Krettek C. Cost–benefit analysis of intraoperative 3D imaging. Unfallchirurg. 2007;110:14–21. PubMedCrossRef
35.
Zurück zum Zitat Ito Y, Sugimoto Y, Tomioka M, Hasegawa Y, Nakago K, Yagata Y. Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. J Neurosurg Spine. 2008;9:450–3. PubMedCrossRef Ito Y, Sugimoto Y, Tomioka M, Hasegawa Y, Nakago K, Yagata Y. Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. J Neurosurg Spine. 2008;9:450–3. PubMedCrossRef
36.
Zurück zum Zitat Nottmeier EW, Crosby TL. Timing of paired points and surface matching registration in three-dimensional (3D) image-guided spinal surgery. J Spinal Disord Tech. 2007;20:268–70. PubMedCrossRef Nottmeier EW, Crosby TL. Timing of paired points and surface matching registration in three-dimensional (3D) image-guided spinal surgery. J Spinal Disord Tech. 2007;20:268–70. PubMedCrossRef
37.
Zurück zum Zitat Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine. 2007;15(32):E56–64. CrossRef Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine. 2007;15(32):E56–64. CrossRef
38.
Zurück zum Zitat Arand M, Kinzl L, Gebhard F. Pitfalls of 2D and 3D navigation in spine surgery. Trauma Berufskrankh. 2005;7:S311–6. CrossRef Arand M, Kinzl L, Gebhard F. Pitfalls of 2D and 3D navigation in spine surgery. Trauma Berufskrankh. 2005;7:S311–6. CrossRef
Metadaten
Titel
3D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screws
verfasst von
J.-S. Jarvers
S. Katscher
A. Franck
S. Glasmacher
C. Schmidt
T. Blattert
C. Josten
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 2/2011
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-011-0098-1

Weitere Artikel der Ausgabe 2/2011

European Journal of Trauma and Emergency Surgery 2/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, DICOM-Daten, Videos und Abbildungen. » Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.