Abstract

Performing surgical procedures often requires a surgeon to develop a skill to create 3-dimensional (3D) mental model on patient’s anatomy. Question remains whether the touching on the 3D printed model can facilitate learning of patient anatomy than viewing the rendered virtual on-screen model. The printed and the virtual 3D model were developed from CT films taken from a 4-year-old girl, who had dysplasia of the hip in the left hip. Eleven subjects were called to report measures on six key anatomical features on the hips. The reporting time and the accuracy were compared between the two models, along with the gaze characteristics of subjects while inspecting the models. The variables were analysed using a 2 × 2 within subject ANOVA to examine the difference between viewing the models (on-screen vs. printed-out) and the side of the hip (right vs. left). Interacting with the printed 3D model required shorter times and yielded more accurate visual judgments than viewing the virtual models on most of the anatomical features. Subjects performed a fewer number of fixations but with a longer mean fixation duration when interacting the printed than inspecting the virtual on-screen 3D model. Results confirmed the value of the printed 3D model on improving the clinical judgement on patient anatomy. Confidence in collecting information from the physical world and the cross-model sensor integration may explain why participants performed better with the printed model compared to the virtual model.
Literatur
1.
Zurück zum Zitat Sidhu RS, Tompa D, Jang R et al (2004) Interpretation of three-dimensional structure from two-dimensional endovascular images: implications for educators in vascular surgery. J Vasc Surg 39(6):1305–1311PubMedCrossRef Sidhu RS, Tompa D, Jang R et al (2004) Interpretation of three-dimensional structure from two-dimensional endovascular images: implications for educators in vascular surgery. J Vasc Surg 39(6):1305–1311PubMedCrossRef
2.
Zurück zum Zitat Zheng YX, Yu DF, Zhao JG, Wu YL, Zheng B (2016) 3D printout models vs. 3D-rendered images: which is better for preoperative planning? J Surg Educ 73(3):518–523PubMedCrossRef Zheng YX, Yu DF, Zhao JG, Wu YL, Zheng B (2016) 3D printout models vs. 3D-rendered images: which is better for preoperative planning? J Surg Educ 73(3):518–523PubMedCrossRef
3.
Zurück zum Zitat Staheli LT (2015) Fundamentals of pediatric orthopedics, 5th edn. Lippincott Williams & Wilkins, Philadelphia Staheli LT (2015) Fundamentals of pediatric orthopedics, 5th edn. Lippincott Williams & Wilkins, Philadelphia
4.
Zurück zum Zitat Peled E, Eidelman M, Katzman A, Bialik V (2008) Neonatal incidence of hip dysplasia: ten years of experience. Clin Orthop Relat Res 466(4):771–775PubMedPubMedCentralCrossRef Peled E, Eidelman M, Katzman A, Bialik V (2008) Neonatal incidence of hip dysplasia: ten years of experience. Clin Orthop Relat Res 466(4):771–775PubMedPubMedCentralCrossRef
5.
Zurück zum Zitat Loder RT, Skopelja EN (2011) The epidemiology and demographics of hip dysplasia. ISRN Orthop 2011:46 Loder RT, Skopelja EN (2011) The epidemiology and demographics of hip dysplasia. ISRN Orthop 2011:46
6.
Zurück zum Zitat Kitoh H, Kawasumi M, Ishiguro N (2009) Predictive factors for unsuccessful treatment of developmental dysplasia of the hip by the Pavlik harness. J Pediatr Orthop 29(6):552–557PubMedCrossRef Kitoh H, Kawasumi M, Ishiguro N (2009) Predictive factors for unsuccessful treatment of developmental dysplasia of the hip by the Pavlik harness. J Pediatr Orthop 29(6):552–557PubMedCrossRef
7.
Zurück zum Zitat Chin MS, Betz BW, Halanski MA (2011) Comparison of hip reduction using magnetic resonance imaging or computed tomography in hip dysplasia. J Pediatr Orthop 31(5):525–529PubMedCrossRef Chin MS, Betz BW, Halanski MA (2011) Comparison of hip reduction using magnetic resonance imaging or computed tomography in hip dysplasia. J Pediatr Orthop 31(5):525–529PubMedCrossRef
8.
9.
Zurück zum Zitat El-Tayeby HM (2009) One-stage hip reconstruction in late neglected developmental dysplasia of the hip presenting in children above 8 years of age. J Child Orthop 3(1):11–20PubMedCrossRef El-Tayeby HM (2009) One-stage hip reconstruction in late neglected developmental dysplasia of the hip presenting in children above 8 years of age. J Child Orthop 3(1):11–20PubMedCrossRef
10.
Zurück zum Zitat Bicanic G, Barbaric K, Bohacek I, Aljinovic A, Delimar D (2014) Current concept in dysplastic hip arthroplasty: techniques for acetabular and femoral reconstruction. World J Orthop 5(4):412–424PubMedPubMedCentralCrossRef Bicanic G, Barbaric K, Bohacek I, Aljinovic A, Delimar D (2014) Current concept in dysplastic hip arthroplasty: techniques for acetabular and femoral reconstruction. World J Orthop 5(4):412–424PubMedPubMedCentralCrossRef
11.
Zurück zum Zitat Shang C, Liu T, Xie H et al (2014) Spatial changes of the peri-acetabular pelvic in developmental dysplasia of the hip—a combined 3-dimentional computed tomography (3D-CT) study in patients and experimental study in rats. Int J Clin Exp Med 7(12):4983–4989PubMedPubMedCentral Shang C, Liu T, Xie H et al (2014) Spatial changes of the peri-acetabular pelvic in developmental dysplasia of the hip—a combined 3-dimentional computed tomography (3D-CT) study in patients and experimental study in rats. Int J Clin Exp Med 7(12):4983–4989PubMedPubMedCentral
12.
Zurück zum Zitat Trajkovski T, Veillette C, Backstein D, Wadey VM, Kraemer B (2012) Resident self-assessment of operative experience in primary total knee and total hip arthroplasty: is it accurate? Can J Surg 55(4):S153–S157PubMedPubMedCentral Trajkovski T, Veillette C, Backstein D, Wadey VM, Kraemer B (2012) Resident self-assessment of operative experience in primary total knee and total hip arthroplasty: is it accurate? Can J Surg 55(4):S153–S157PubMedPubMedCentral
13.
Zurück zum Zitat Karam MD, Westerlind B, Anderson DD, Marsh JL (2013) Development of an orthopaedic surgical skills curriculum for post-graduate year one resident learners—the University of Iowa experience. Iowa Orthop J 33:178–184PubMedPubMedCentral Karam MD, Westerlind B, Anderson DD, Marsh JL (2013) Development of an orthopaedic surgical skills curriculum for post-graduate year one resident learners—the University of Iowa experience. Iowa Orthop J 33:178–184PubMedPubMedCentral
14.
Zurück zum Zitat Sartoris DJ, Resnick D, Bielecki D, Gershuni D, Meyers M (1988) Computed tomography with multiplanar reformation and three-dimensional image reconstruction in the preoperative evaluation of adult hip disease. Int Orthop 12(1):1–8PubMedCrossRef Sartoris DJ, Resnick D, Bielecki D, Gershuni D, Meyers M (1988) Computed tomography with multiplanar reformation and three-dimensional image reconstruction in the preoperative evaluation of adult hip disease. Int Orthop 12(1):1–8PubMedCrossRef
15.
Zurück zum Zitat Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia AM (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aid Surg 10(1):37–43CrossRef Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia AM (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aid Surg 10(1):37–43CrossRef
16.
Zurück zum Zitat Dutoit M, Zambelli PY (1999) Simplified 3D-evaluation of periacetabular osteotomy. Acta Orthop Belg 65(3):288–294PubMed Dutoit M, Zambelli PY (1999) Simplified 3D-evaluation of periacetabular osteotomy. Acta Orthop Belg 65(3):288–294PubMed
17.
Zurück zum Zitat Michalski MH, Ross JS (2014) The shape of things to come: 3D printing in medicine. JAMA 312(21):2213–2214PubMedCrossRef Michalski MH, Ross JS (2014) The shape of things to come: 3D printing in medicine. JAMA 312(21):2213–2214PubMedCrossRef
18.
Zurück zum Zitat Kundel HL, Nodine CF (1983) A visual concept shapes image perception. Radiology 146(2):363–368PubMedCrossRef Kundel HL, Nodine CF (1983) A visual concept shapes image perception. Radiology 146(2):363–368PubMedCrossRef
19.
Zurück zum Zitat Mello-Thoms C, Hardesty L, Sumkin J et al (2005) Effects of lesion conspicuity on visual search in mammogram reading. Acad Radiol 12(7):830–840PubMedCrossRef Mello-Thoms C, Hardesty L, Sumkin J et al (2005) Effects of lesion conspicuity on visual search in mammogram reading. Acad Radiol 12(7):830–840PubMedCrossRef
20.
Zurück zum Zitat Nodine CF, Kundel HL, Lauver SC, Toto LC (1996) Nature of expertise in searching mammograms for breast masses. Acad Radiol 3(12):1000–1006PubMedCrossRef Nodine CF, Kundel HL, Lauver SC, Toto LC (1996) Nature of expertise in searching mammograms for breast masses. Acad Radiol 3(12):1000–1006PubMedCrossRef
21.
Zurück zum Zitat Nodine CF, Mello-Thoms C, Kundel HL, Weinstein SP (2002) Time course of perception and decision making during mammographic interpretation. AJR Am J Roentgenol 179(4):917–923PubMedCrossRef Nodine CF, Mello-Thoms C, Kundel HL, Weinstein SP (2002) Time course of perception and decision making during mammographic interpretation. AJR Am J Roentgenol 179(4):917–923PubMedCrossRef
22.
Zurück zum Zitat Atkins MS, Jiang X, Tien G, Zheng B (2013) What do surgeons see: capturing and synchronizing eye gaze for surgery applications. Surg Innov 20(3):243–250CrossRef Atkins MS, Jiang X, Tien G, Zheng B (2013) What do surgeons see: capturing and synchronizing eye gaze for surgery applications. Surg Innov 20(3):243–250CrossRef
23.
Zurück zum Zitat Atkins MS, Nicolaou M, Yang GZ (2008) Eye monitoring applications in medicine. In: Hammoud RI (ed) Passive eye monitoring: algorithms, applications and experiments. Springer, Berlin, pp 323–346CrossRef Atkins MS, Nicolaou M, Yang GZ (2008) Eye monitoring applications in medicine. In: Hammoud RI (ed) Passive eye monitoring: algorithms, applications and experiments. Springer, Berlin, pp 323–346CrossRef
24.
Zurück zum Zitat Law B, Atkins MS, Kirkpatrick AE, Lomax AJ (2004) Eye gaze patterns differentiate novice and experts in a virtual laparoscopic surgery training environment. In: Proceedings of the 2004 symposium on eye tracking research and applications. ACM, San Antonio, TX, pp 41–48 Law B, Atkins MS, Kirkpatrick AE, Lomax AJ (2004) Eye gaze patterns differentiate novice and experts in a virtual laparoscopic surgery training environment. In: Proceedings of the 2004 symposium on eye tracking research and applications. ACM, San Antonio, TX, pp 41–48
25.
Zurück zum Zitat Pieper P, Halle M, Kikinis R (2004) 3D Slicer. In: IEEE int symp biomed imaging, pp 632–635 Pieper P, Halle M, Kikinis R (2004) 3D Slicer. In: IEEE int symp biomed imaging, pp 632–635
26.
Zurück zum Zitat Helbig HB, Ernst MO (2007) Optimal integration of shape information from vision and touch. Exp Brain Res 179(4):595–606PubMedCrossRef Helbig HB, Ernst MO (2007) Optimal integration of shape information from vision and touch. Exp Brain Res 179(4):595–606PubMedCrossRef
27.
Zurück zum Zitat Wijntjes MW, Volcic R, Pont SC, Koenderink JJ, Kappers AM (2009) Haptic perception disambiguates visual perception of 3D shape. Exp Brain Res 193(4):639–644PubMedCrossRef Wijntjes MW, Volcic R, Pont SC, Koenderink JJ, Kappers AM (2009) Haptic perception disambiguates visual perception of 3D shape. Exp Brain Res 193(4):639–644PubMedCrossRef
28.
Zurück zum Zitat Bordegoni M, Cugini U, Ferrise F, Covarrubias M (2012) Haptic interaction with virtual surfaces. In: ACM CHI. ACM, New York Bordegoni M, Cugini U, Ferrise F, Covarrubias M (2012) Haptic interaction with virtual surfaces. In: ACM CHI. ACM, New York
29.
Zurück zum Zitat Helbig HB, Ernst MO, Ricciardi E et al (2012) The neural mechanisms of reliability weighted integration of shape information from vision and touch. NeuroImage 60(2):1063–1072PubMedCrossRef Helbig HB, Ernst MO, Ricciardi E et al (2012) The neural mechanisms of reliability weighted integration of shape information from vision and touch. NeuroImage 60(2):1063–1072PubMedCrossRef
30.
Zurück zum Zitat Maravita A, Spence C, Driver J (2003) Multisensory integration and the body schema: close to hand and within reach. Curr Biol 13(13):R531-539CrossRef Maravita A, Spence C, Driver J (2003) Multisensory integration and the body schema: close to hand and within reach. Curr Biol 13(13):R531-539CrossRef
Metadaten
Titel
3D-printed model improves clinical assessment of surgeons on anatomy
verfasst von
Bin Zheng
Xiaolin Wang
Yixiong Zheng
Jiexiong Feng
Publikationsdatum
24.04.2018
Verlag
Springer London
Erschienen in
Journal of Robotic Surgery / Ausgabe 1/2019
Print ISSN: 1863-2483
Elektronische ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-018-0809-2

Weitere Artikel der Ausgabe 1/2019

Journal of Robotic Surgery 1/2019 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.