Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 5/2009

01.09.2009 | Technical Note

3D Stereoscopic Visualization of Fenestrated Stent Grafts

verfasst von: Zhonghua Sun, Andrew Squelch, Andrew Bartlett, Kylie Cunningham, Michael Lawrence-Brown

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 5/2009

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall’s W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.
Literatur
1.
Zurück zum Zitat Sun Z, Mwipatayi B, Semmens J, Lawrence-Brown M (2006) Short to mid-term outcomes of fenestrated endovascular grafting of aortic aneurysms: a systematic review. J Endovasc Ther 13:747–753PubMedCrossRef Sun Z, Mwipatayi B, Semmens J, Lawrence-Brown M (2006) Short to mid-term outcomes of fenestrated endovascular grafting of aortic aneurysms: a systematic review. J Endovasc Ther 13:747–753PubMedCrossRef
2.
Zurück zum Zitat Browne TF, Hartley D, Purchas S et al (1999) A fenestrated covered suprarenal aortic stent. Eur J Vasc Endovasc Surg 18:445–449PubMedCrossRef Browne TF, Hartley D, Purchas S et al (1999) A fenestrated covered suprarenal aortic stent. Eur J Vasc Endovasc Surg 18:445–449PubMedCrossRef
3.
Zurück zum Zitat Stanley BM, Semmens JB, Lawrence-Brown MM et al (2001) Fenestration in endovascular grafts for aortic aneurysm repair: new horizons for preserving blood flow in branch vessels. J Endovasc Ther 8:16–24PubMedCrossRef Stanley BM, Semmens JB, Lawrence-Brown MM et al (2001) Fenestration in endovascular grafts for aortic aneurysm repair: new horizons for preserving blood flow in branch vessels. J Endovasc Ther 8:16–24PubMedCrossRef
4.
Zurück zum Zitat Anderson JL, Berce M, Hartley DE (2001) Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration. J Endovasc Ther 8:3–15PubMedCrossRef Anderson JL, Berce M, Hartley DE (2001) Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration. J Endovasc Ther 8:3–15PubMedCrossRef
5.
Zurück zum Zitat McAllister JDF (ed) (1993) Stereo computer graphics and other true 3D technologies. Princeton University Press, Princeton, NJ McAllister JDF (ed) (1993) Stereo computer graphics and other true 3D technologies. Princeton University Press, Princeton, NJ
6.
Zurück zum Zitat Rydmark M, Kling-Peterson T, Pascher R, Philip F (2001) 3D visualization and stereographic techniques for medical research and education. Stud Health Technol Inform 81:434–439PubMed Rydmark M, Kling-Peterson T, Pascher R, Philip F (2001) 3D visualization and stereographic techniques for medical research and education. Stud Health Technol Inform 81:434–439PubMed
7.
Zurück zum Zitat Goodsitt MM, Chan HP, Darner KL, Hadjiiski LM (2002) The effects of stereo shift angle, geometric magnification and display zoon on depth measurements in digital stereo-mammography. Med Phys 29:2725–2734PubMedCrossRef Goodsitt MM, Chan HP, Darner KL, Hadjiiski LM (2002) The effects of stereo shift angle, geometric magnification and display zoon on depth measurements in digital stereo-mammography. Med Phys 29:2725–2734PubMedCrossRef
8.
Zurück zum Zitat Nelson T, Ji EK, Lee JH et al (2008) Stereoscopic evaluation of fetal bony structures. J Ultrasound Med 27:15–24PubMed Nelson T, Ji EK, Lee JH et al (2008) Stereoscopic evaluation of fetal bony structures. J Ultrasound Med 27:15–24PubMed
9.
Zurück zum Zitat Hernandez A, Basset O, Bremond A, Magnin I (1998) Stereoscopic visualization of three-dimensional ultrasonic data applied to breast tumours. Eur J Ultrasound 8:51–65PubMedCrossRef Hernandez A, Basset O, Bremond A, Magnin I (1998) Stereoscopic visualization of three-dimensional ultrasonic data applied to breast tumours. Eur J Ultrasound 8:51–65PubMedCrossRef
10.
Zurück zum Zitat DeAngelis G (2000) Seeing in three dimensions: the neurophysiology of stereopsis. Trends Cogn Sci 4:80–90PubMedCrossRef DeAngelis G (2000) Seeing in three dimensions: the neurophysiology of stereopsis. Trends Cogn Sci 4:80–90PubMedCrossRef
11.
Zurück zum Zitat Zhou L, Wang Y, Goh LC et al (2006) Stereoscopic visualization and editing of automatic abdominal aortic aneurysms (AAA) measurements for stent graft planning. SPIE 6055:1–9 Zhou L, Wang Y, Goh LC et al (2006) Stereoscopic visualization and editing of automatic abdominal aortic aneurysms (AAA) measurements for stent graft planning. SPIE 6055:1–9
12.
Zurück zum Zitat Rydberg J, Kopecky KK, Lalka SG et al (2001) Stent grafting of abdominal aortic aneurysms: pre-and postoperative evaluation with multislice helical CT. J Comput Assist Tomogr 25:580–586PubMedCrossRef Rydberg J, Kopecky KK, Lalka SG et al (2001) Stent grafting of abdominal aortic aneurysms: pre-and postoperative evaluation with multislice helical CT. J Comput Assist Tomogr 25:580–586PubMedCrossRef
13.
Zurück zum Zitat Armerding MD, Rubin GD, Beaulieu CF et al (2000) Aortic aneurysmal disease: assessment of stent-grafted treatment-CT versus conventional angiography. Radiology 215:138–146PubMed Armerding MD, Rubin GD, Beaulieu CF et al (2000) Aortic aneurysmal disease: assessment of stent-grafted treatment-CT versus conventional angiography. Radiology 215:138–146PubMed
14.
Zurück zum Zitat Sun Z, Winder J, Kelly B et al (2004) Diagnostic value of CT virtual intravascular endoscopy in aortic stent grafting. J Endovasc Ther 11:13–25PubMedCrossRef Sun Z, Winder J, Kelly B et al (2004) Diagnostic value of CT virtual intravascular endoscopy in aortic stent grafting. J Endovasc Ther 11:13–25PubMedCrossRef
Metadaten
Titel
3D Stereoscopic Visualization of Fenestrated Stent Grafts
verfasst von
Zhonghua Sun
Andrew Squelch
Andrew Bartlett
Kylie Cunningham
Michael Lawrence-Brown
Publikationsdatum
01.09.2009
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 5/2009
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-008-9494-2

Weitere Artikel der Ausgabe 5/2009

CardioVascular and Interventional Radiology 5/2009 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.