Skip to main content
Erschienen in:

08.08.2023 | Commentary

A better understanding of liver T1

verfasst von: Diego Hernando, Rianne A. van der Heijden, Scott B. Reeder

Erschienen in: European Radiology | Ausgabe 10/2023

Einloggen, um Zugang zu erhalten

Excerpt

The technical development of quantitative imaging methods can be framed as an iterative process to enable unbiased and precise (i.e., repeatable and reproducible) measurements of tissue properties. A central component of this process consists of identifying and addressing the relevant confounding factors, i.e., undesired effects that lead to bias and/or poor precision in the quantification. Once the technical performance is adequate, clinical qualification is needed to evaluate the method’s performance for the screening, diagnosis, staging, prognosis, or treatment monitoring in a specific condition and target population [1]. …
Literatur
1.
Zurück zum Zitat Weingartner S, Desmond KL, Obuchowski NA et al (2022) Development, validation, qualification, and dissemination of quantitative MR methods: overview and recommendations by the ISMRM quantitative MR study group. Magn Reson Med 87(3):1184–1206CrossRefPubMed Weingartner S, Desmond KL, Obuchowski NA et al (2022) Development, validation, qualification, and dissemination of quantitative MR methods: overview and recommendations by the ISMRM quantitative MR study group. Magn Reson Med 87(3):1184–1206CrossRefPubMed
2.
Zurück zum Zitat Banerjee R, Pavlides M, Tunnicliffe EM et al (2014) Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease. J Hepatol 60(1):69–77CrossRefPubMedPubMedCentral Banerjee R, Pavlides M, Tunnicliffe EM et al (2014) Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease. J Hepatol 60(1):69–77CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Mozes FE, Tunnicliffe EM, Moolla A et al (2019) Mapping tissue water T(1) in the liver using the MOLLI T(1) method in the presence of fat, iron and B(0) inhomogeneity. NMR Biomed 32(2):e4030CrossRefPubMed Mozes FE, Tunnicliffe EM, Moolla A et al (2019) Mapping tissue water T(1) in the liver using the MOLLI T(1) method in the presence of fat, iron and B(0) inhomogeneity. NMR Biomed 32(2):e4030CrossRefPubMed
6.
Zurück zum Zitat Wang N, Cao T, Han F et al (2022) Free-breathing multitasking multi-echo MRI for whole-liver water-specific T1, proton density fat fraction, and R2* quantification. Magn Reson Med 87(1):120–137CrossRefPubMed Wang N, Cao T, Han F et al (2022) Free-breathing multitasking multi-echo MRI for whole-liver water-specific T1, proton density fat fraction, and R2* quantification. Magn Reson Med 87(1):120–137CrossRefPubMed
7.
Zurück zum Zitat Fujita S, Sano K, Cruz G et al (2023) MR fingerprinting for liver tissue characterization: a histopathologic correlation study. Radiology 306(1):150–159CrossRefPubMed Fujita S, Sano K, Cruz G et al (2023) MR fingerprinting for liver tissue characterization: a histopathologic correlation study. Radiology 306(1):150–159CrossRefPubMed
8.
Zurück zum Zitat Thompson RB, Chow K, Mager D, Pagano JJ, Grenier J (2021) Simultaneous proton density fat-fraction and R2 * imaging with water-specific T(1) mapping (PROFIT(1) ): application in liver. Magn Reson Med 85(1):223–238CrossRefPubMed Thompson RB, Chow K, Mager D, Pagano JJ, Grenier J (2021) Simultaneous proton density fat-fraction and R2 * imaging with water-specific T(1) mapping (PROFIT(1) ): application in liver. Magn Reson Med 85(1):223–238CrossRefPubMed
Metadaten
Titel
A better understanding of liver T1
verfasst von
Diego Hernando
Rianne A. van der Heijden
Scott B. Reeder
Publikationsdatum
08.08.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 10/2023
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-023-10067-7

Neu im Fachgebiet Radiologie

KI-gestütztes Mammografiescreening überzeugt im Praxistest

Mit dem Einsatz künstlicher Intelligenz lässt sich die Detektionsrate im Mammografiescreening offenbar deutlich steigern. Mehr unnötige Zusatzuntersuchungen sind laut der Studie aus Deutschland nicht zu befürchten.

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.