A biomechanical comparison of three fixation techniques in osteoporotic reverse oblique intertrochanteric femur fracture with fragmented lateral cortex

verfasst von: Gökhan Polat, Turgut Akgül, Mehmet Ekinci, Serkan Bayram

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Background

The treatment of the reverse oblique osteoporotic femur fractures is still problematic and can be complicated especially that are accompanied by a fragmented lateral cortex.

Aim

The aim of this study was to compare three different internal fixation methods in the osteosynthesis of osteoporotic reverse oblique intertrochanteric femur fracture models with a fragmented lateral cortex.

Study design

Biomechanical experiment study.

Methods

A total of 24 osteoporotic femur models were obtained and divided into three groups [Group A: Proximal femoral nail (PFN), Group B: 95° angled blade plate (ABP), and Group C: proximal femoral anatomic locking plate (PFLP)] with each group which include eight bones. A standard fracture configuration was created as a reverse oblique intertrochanteric fracture and fixed with these implants. After fixation, all femur constructs were tested with an Instron 5800R tester (Instron, Canton, MA) in the biomechanics laboratory with axial loading and bending forces to assess axial and rotational stiffness and failure load. Displacement over 10 mm and angulation greater than 10° in the fracture line were considered as failure.

Results

In all tests, ABP had statistically poorer results in comparison to the PFN and PFLP group. PFLP fixation had better biomechanical fixation results in comparison to the PFN group, although the results were not statistically significant.

Conclusion

Orthopaedic surgeons should keep in mind that lateral cortex comminution brings further instability to these reverse oblique intertrochanteric osteoporotic fractures and high rates of failure may be encountered due to this instability. PFLP fixation may be an alternative fixation method biomechanically for these instable fractures.
Literatur
1.
Zurück zum Zitat Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A. Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025. J Bone Miner Res. 2007;22:465–75.CrossRefPubMed Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A. Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025. J Bone Miner Res. 2007;22:465–75.CrossRefPubMed
2.
Zurück zum Zitat Radford PJ, Needoff M, Webb JK. Aprospective randomised comparison of the dynamic hip screw and the gamma locking nail. J Bone Jt Surg Br. 1993;75(5):789–93.CrossRef Radford PJ, Needoff M, Webb JK. Aprospective randomised comparison of the dynamic hip screw and the gamma locking nail. J Bone Jt Surg Br. 1993;75(5):789–93.CrossRef
3.
Zurück zum Zitat Nuber S, Schönweiss T, Rüter A. Stabilisation of unstable trochanteric femoral fractures. Dynamic hip screw (DHS) with trochanteric stabilisation plate vs. proximal femur nail (PFN). Unfallchirurg. 2003;106(1):39–47.CrossRefPubMed Nuber S, Schönweiss T, Rüter A. Stabilisation of unstable trochanteric femoral fractures. Dynamic hip screw (DHS) with trochanteric stabilisation plate vs. proximal femur nail (PFN). Unfallchirurg. 2003;106(1):39–47.CrossRefPubMed
4.
5.
Zurück zum Zitat Zha GC, Chen ZL, Qi XB, Sun JY. Treatment of pertrochanteric fractures with a proximal femur locking compression plate. Injury. 2011;42(11):1294–9.CrossRefPubMed Zha GC, Chen ZL, Qi XB, Sun JY. Treatment of pertrochanteric fractures with a proximal femur locking compression plate. Injury. 2011;42(11):1294–9.CrossRefPubMed
6.
Zurück zum Zitat Kokoroghiannis C, Aktselis I, Deligeorgis A, Fragkomichalos E, Papadimas D, Pappadas I. Evolving concepts of stability and intramedullary fixation of intertrochanteric fractures—a review. Injury. 2012 Jun;43(6):686–93.CrossRefPubMed Kokoroghiannis C, Aktselis I, Deligeorgis A, Fragkomichalos E, Papadimas D, Pappadas I. Evolving concepts of stability and intramedullary fixation of intertrochanteric fractures—a review. Injury. 2012 Jun;43(6):686–93.CrossRefPubMed
7.
Zurück zum Zitat Lamb JN, Panteli M, Pneumaticos SG, Giannoudis PV. Epidemiology of pertrochanteric fractures: our institutional experience. Eur J Trauma Emerg Surg. 2014;40(3):225–32.CrossRefPubMed Lamb JN, Panteli M, Pneumaticos SG, Giannoudis PV. Epidemiology of pertrochanteric fractures: our institutional experience. Eur J Trauma Emerg Surg. 2014;40(3):225–32.CrossRefPubMed
8.
Zurück zum Zitat Yao C, Zhang CQ, Jin DX, Chen YF. Early results of reverse less invasive stabilization system plating in treating elderly intertrochanteric fractures: a prospective study compared to proximal femoral nail. Chin Med J (Engl). 2011;124:2150–7. Yao C, Zhang CQ, Jin DX, Chen YF. Early results of reverse less invasive stabilization system plating in treating elderly intertrochanteric fractures: a prospective study compared to proximal femoral nail. Chin Med J (Engl). 2011;124:2150–7.
9.
Zurück zum Zitat Loizou C, Mcnamara I, Ahmed K, Pryor G, Parker M. Classification of subtrochanteric femoral fractures. Injury. 2010;41:739–45.CrossRefPubMed Loizou C, Mcnamara I, Ahmed K, Pryor G, Parker M. Classification of subtrochanteric femoral fractures. Injury. 2010;41:739–45.CrossRefPubMed
10.
Zurück zum Zitat Palm H, Jacobsen S, Sonne-Holm S, Gebuhr P. Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation. J Bone Jt Surg Am. 2007;89:470–47.CrossRef Palm H, Jacobsen S, Sonne-Holm S, Gebuhr P. Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation. J Bone Jt Surg Am. 2007;89:470–47.CrossRef
11.
Zurück zum Zitat van Meeteren MC, van Rief YE, Roukema JA, et al. Condylar plate fixation of subtrochanteric femoral fractures. Injury. 1996;27:715–7.CrossRefPubMed van Meeteren MC, van Rief YE, Roukema JA, et al. Condylar plate fixation of subtrochanteric femoral fractures. Injury. 1996;27:715–7.CrossRefPubMed
12.
Zurück zum Zitat Yoo MC, Cho YJ, Kim KI, et al. Treatment of unstable peritrochanteric femoral fractures using a 95 degrees angled blade plate. J Orthop Trauma. 2005;19:687–92.CrossRefPubMed Yoo MC, Cho YJ, Kim KI, et al. Treatment of unstable peritrochanteric femoral fractures using a 95 degrees angled blade plate. J Orthop Trauma. 2005;19:687–92.CrossRefPubMed
13.
Zurück zum Zitat Sadowski C, Lübbeke A, Saudan M, Riand N, Stern R, Hoffmeyer P. Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Jt Surg Am. 2002;84-A(3):372–81.CrossRef Sadowski C, Lübbeke A, Saudan M, Riand N, Stern R, Hoffmeyer P. Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Jt Surg Am. 2002;84-A(3):372–81.CrossRef
14.
Zurück zum Zitat Kumar N, Kataria H, Yadav CS, Gadagoli BS, Raj R. Evaluation of proximal femoral locking plate in unstable extracapsular proximal femoral fractures: surgical technique and mid term follow up results. J Clin Orthop Trauma. 2014;5(3):137–45.CrossRefPubMedPubMedCentral Kumar N, Kataria H, Yadav CS, Gadagoli BS, Raj R. Evaluation of proximal femoral locking plate in unstable extracapsular proximal femoral fractures: surgical technique and mid term follow up results. J Clin Orthop Trauma. 2014;5(3):137–45.CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Kraus J, Volf V, Burget F, Jindrová B. PCCP versus standard proximal femoral nail in the treatment of pertrochanteric femoral fractures. Rozhl Chir. 2009;88(8):469–74.PubMed Kraus J, Volf V, Burget F, Jindrová B. PCCP versus standard proximal femoral nail in the treatment of pertrochanteric femoral fractures. Rozhl Chir. 2009;88(8):469–74.PubMed
16.
Zurück zum Zitat Streubel PN, Moustoukas M, Obremskey WT. Locked plating versus cephalomedullary nailing of unstable intertrochanteric femur fractures. Eur J Orthop Surg Traumatol. 2016;26(4):385–90.CrossRefPubMed Streubel PN, Moustoukas M, Obremskey WT. Locked plating versus cephalomedullary nailing of unstable intertrochanteric femur fractures. Eur J Orthop Surg Traumatol. 2016;26(4):385–90.CrossRefPubMed
17.
Zurück zum Zitat Johnson B, Stevenson J, Chamma R, Patel A, Rhee SJ, Lever C, Starks I, Roberts PJ. Short-term follow-up of pertrochanteric fractures treated using the proximal femoral locking plate. J Orthop Trauma. 2014;28(5):283–7.CrossRefPubMed Johnson B, Stevenson J, Chamma R, Patel A, Rhee SJ, Lever C, Starks I, Roberts PJ. Short-term follow-up of pertrochanteric fractures treated using the proximal femoral locking plate. J Orthop Trauma. 2014;28(5):283–7.CrossRefPubMed
18.
Zurück zum Zitat Collinge CA, Hymes R, Archdeacon M, Streubel P, Obremskey W, Weber T, Watson JT, Lowenberg D, Members of the Proximal Femur Working Group of the Southeast Trauma Consortium. Unstable proximal femur fractures treated with proximal femoral locking plates: a retrospective, multicenter study of 111 cases. J Orthop Trauma. 2016;30(9):489–95.CrossRefPubMed Collinge CA, Hymes R, Archdeacon M, Streubel P, Obremskey W, Weber T, Watson JT, Lowenberg D, Members of the Proximal Femur Working Group of the Southeast Trauma Consortium. Unstable proximal femur fractures treated with proximal femoral locking plates: a retrospective, multicenter study of 111 cases. J Orthop Trauma. 2016;30(9):489–95.CrossRefPubMed
19.
Zurück zum Zitat Zderic I, Oh JK, Stoffel K, Sommer C, Helfen T, Camino G, Richards G, Nork SE, Gueorguiev B. Biomechanical analysis of the proximal femoral locking compression plate: do quality of reduction and screw orientation influence construct stability? J Orthop Trauma. 2018;32(2):67–74.CrossRefPubMed Zderic I, Oh JK, Stoffel K, Sommer C, Helfen T, Camino G, Richards G, Nork SE, Gueorguiev B. Biomechanical analysis of the proximal femoral locking compression plate: do quality of reduction and screw orientation influence construct stability? J Orthop Trauma. 2018;32(2):67–74.CrossRefPubMed
20.
Zurück zum Zitat Ma JX, Wang J, Xu WG, Yu JT, Yang Y, Ma XL. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures. Acta Orthop Traumatol Turc. 2015;49(4):426–32.PubMed Ma JX, Wang J, Xu WG, Yu JT, Yang Y, Ma XL. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures. Acta Orthop Traumatol Turc. 2015;49(4):426–32.PubMed
21.
Zurück zum Zitat Singh AK, Narsaria N, Gupta RK. A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures. Injury. 2017;48(10):2050–3.CrossRefPubMed Singh AK, Narsaria N, Gupta RK. A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures. Injury. 2017;48(10):2050–3.CrossRefPubMed
22.
Zurück zum Zitat Ozkan K, Türkmen İ, Sahin A, Yildiz Y, Erturk S, Soylemez MS. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation: a study on synthetic bones. Indian J Orthop. 2015;49(3):347–51.CrossRefPubMedPubMedCentral Ozkan K, Türkmen İ, Sahin A, Yildiz Y, Erturk S, Soylemez MS. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation: a study on synthetic bones. Indian J Orthop. 2015;49(3):347–51.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Floyd MW, France JC, Hubbard DF. Early experience with the proximal femoral locking plate. Orthopedics. 2013;36(12):1488–94.CrossRef Floyd MW, France JC, Hubbard DF. Early experience with the proximal femoral locking plate. Orthopedics. 2013;36(12):1488–94.CrossRef
Metadaten
Titel
A biomechanical comparison of three fixation techniques in osteoporotic reverse oblique intertrochanteric femur fracture with fragmented lateral cortex
verfasst von
Gökhan Polat
Turgut Akgül
Mehmet Ekinci
Serkan Bayram
Publikationsdatum
02.01.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 3/2019
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-018-1061-1

Weitere Artikel der Ausgabe 3/2019

European Journal of Trauma and Emergency Surgery 3/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.