A Critical Evaluation of Fatigue Studies for Restorative Materials in Dentistry

verfasst von: Martin Rosentritt, Michael Behr, Verena Preis

Erschienen in: Current Oral Health Reports | Ausgabe 3/2016

Einloggen, um Zugang zu erhalten

Abstract

Fatigue tests are state of the art in dental materials testing for estimating the lifetime performance of materials or restorations. A number of different loading situations are tested with varying parameters, which are based on statistical methods or clinical experience. Partly, inadequate information is provided for a sufficient description and evaluation of the applied methods and resulting data. Several in vitro studies with limited clinical relevance have been published. This review gives a critical overview of fatigue methods published in dental literature. A clear differentiation should be made between fatigue tests for fundamental materials research and component testing of dental restorations. For structural testing, a correlation between in vitro data and in vitro performance is required. Correlation should be based on detailed evaluation of the clinical situation.
Literatur
1.
Zurück zum Zitat Beuth J. Load controlled fatigue testing—execution and evaluation of cyclic tests at constant load amplitudes on metallic specimens and components. Berlin: Beuth Verlag; 2015. Beuth J. Load controlled fatigue testing—execution and evaluation of cyclic tests at constant load amplitudes on metallic specimens and components. Berlin: Beuth Verlag; 2015.
2.••
Zurück zum Zitat Roesler J, Harders H, Baeker M. Mechanical behaviour of engineering materials: metals, ceramics, polymers. Berlin: Springer-Verlag; 2007. Proving important basic knowledge on the topic. Roesler J, Harders H, Baeker M. Mechanical behaviour of engineering materials: metals, ceramics, polymers. Berlin: Springer-Verlag; 2007. Proving important basic knowledge on the topic.
4.
Zurück zum Zitat Aboushelib MN. Fatigue and fracture resistance of zirconia crowns prepared with different finish line designs. J Prosthodont. 2012;21(1):22–7.CrossRefPubMed Aboushelib MN. Fatigue and fracture resistance of zirconia crowns prepared with different finish line designs. J Prosthodont. 2012;21(1):22–7.CrossRefPubMed
5.
Zurück zum Zitat Amir Rad FA, Succaria FG, Morgano SM. Fracture resistance of porcelain veneered zirconia crowns with exposed lingual zirconia for anterior teeth after thermal cycling: an in vitro study. Saudi Dent J. 2015;27(2):63–9.CrossRefPubMedPubMedCentral Amir Rad FA, Succaria FG, Morgano SM. Fracture resistance of porcelain veneered zirconia crowns with exposed lingual zirconia for anterior teeth after thermal cycling: an in vitro study. Saudi Dent J. 2015;27(2):63–9.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Silva NRFA, Bonfante E, Rafferty BT, Zavanelli RA, Martins LL, Rekow ED, et al. Conventional and modified veneered zirconia vs. metalloceramic: fatigue and finite element analysis. J Prosthodont. 2012;21(6):433–9.CrossRefPubMed Silva NRFA, Bonfante E, Rafferty BT, Zavanelli RA, Martins LL, Rekow ED, et al. Conventional and modified veneered zirconia vs. metalloceramic: fatigue and finite element analysis. J Prosthodont. 2012;21(6):433–9.CrossRefPubMed
7.
Zurück zum Zitat Alqahtani F, Flinton R. Postfatigue fracture resistance of modified prefabricated zirconia implant abutments. J Prosthet Dent. 2014;112(2):299–305.CrossRefPubMed Alqahtani F, Flinton R. Postfatigue fracture resistance of modified prefabricated zirconia implant abutments. J Prosthet Dent. 2014;112(2):299–305.CrossRefPubMed
8.
Zurück zum Zitat Eroğlu Z, Gurbulak AG. Fatigue behavior of zirconia-ceramic, galvano-ceramic, and porcelain-fused-to-metal fixed partial dentures. J Prosthodont. 2013;22(7):516–22.CrossRefPubMed Eroğlu Z, Gurbulak AG. Fatigue behavior of zirconia-ceramic, galvano-ceramic, and porcelain-fused-to-metal fixed partial dentures. J Prosthodont. 2013;22(7):516–22.CrossRefPubMed
9.
Zurück zum Zitat Ghazy MH, Madina MM, Aboushelib MN. Influence of fabrication techniques and artificial aging on the fracture resistance of different cantilever zirconia fixed dental prostheses. J Adhes Dent. 2012;14(2):161–6.PubMed Ghazy MH, Madina MM, Aboushelib MN. Influence of fabrication techniques and artificial aging on the fracture resistance of different cantilever zirconia fixed dental prostheses. J Adhes Dent. 2012;14(2):161–6.PubMed
10.
Zurück zum Zitat Jiang T, Chen C, Lv P. Selective infiltrated etching to surface treat zirconia using a modified glass agent. J Adhes Dent. 2014;16(6):553–7.PubMed Jiang T, Chen C, Lv P. Selective infiltrated etching to surface treat zirconia using a modified glass agent. J Adhes Dent. 2014;16(6):553–7.PubMed
11.
Zurück zum Zitat Perdigão J, Pinto AM, Monteiro RCC, Braz Fernandes FM, Laranjeira P, Veiga JP. Degradation of dental ZrO2-based materials after hydrothermal fatigue. Part I: XRD, XRF, and FESEM analyses. Dent Mater J. 2012;31(2):256–65.CrossRefPubMed Perdigão J, Pinto AM, Monteiro RCC, Braz Fernandes FM, Laranjeira P, Veiga JP. Degradation of dental ZrO2-based materials after hydrothermal fatigue. Part I: XRD, XRF, and FESEM analyses. Dent Mater J. 2012;31(2):256–65.CrossRefPubMed
12.
Zurück zum Zitat Schmitter M, Mueller D, Rues S. Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer. J Dent. 2012;40(2):154–62.CrossRefPubMed Schmitter M, Mueller D, Rues S. Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer. J Dent. 2012;40(2):154–62.CrossRefPubMed
13.
Zurück zum Zitat Seto KB, McLaren EA, Caputo AA, White SN. Fatigue behavior of the resinous cement to zirconia bond. J Prosthodont. 2013;22(7):523–8.CrossRefPubMed Seto KB, McLaren EA, Caputo AA, White SN. Fatigue behavior of the resinous cement to zirconia bond. J Prosthodont. 2013;22(7):523–8.CrossRefPubMed
14.
Zurück zum Zitat Ayatollahi MR, Yahya MY, Karimzadeh A, Nikkhooyifar M, Ayob A. Effects of temperature change and beverage on mechanical and tribological properties of dental restorative composites. Mater Sci Eng C Mater Biol Appl. 2015;54:69–75.CrossRefPubMed Ayatollahi MR, Yahya MY, Karimzadeh A, Nikkhooyifar M, Ayob A. Effects of temperature change and beverage on mechanical and tribological properties of dental restorative composites. Mater Sci Eng C Mater Biol Appl. 2015;54:69–75.CrossRefPubMed
15.
Zurück zum Zitat Bortolotto T, Bahillo J, Richoz O, Hafezi F, Krejci I. Failure analysis of adhesive restorations with SEM and OCT: from marginal gaps to restoration loss. Clin Oral Investig. 2015;19(8):1881–90.CrossRefPubMed Bortolotto T, Bahillo J, Richoz O, Hafezi F, Krejci I. Failure analysis of adhesive restorations with SEM and OCT: from marginal gaps to restoration loss. Clin Oral Investig. 2015;19(8):1881–90.CrossRefPubMed
16.
Zurück zum Zitat Hamano N, Chiang Y, Nyamaa I, Yamaguchi H, Ino S, Hickel R, et al. Repair of silorane-based dental composites: influence of surface treatments. Dent Mater. 2012;28(8):894–902.CrossRefPubMed Hamano N, Chiang Y, Nyamaa I, Yamaguchi H, Ino S, Hickel R, et al. Repair of silorane-based dental composites: influence of surface treatments. Dent Mater. 2012;28(8):894–902.CrossRefPubMed
17.
Zurück zum Zitat Hurley RK, Drummond JL, Viana GC, Galang MT. The effects of environment and cyclic fatigue on the mechanical properties of an indirect composite. J Dent. 2012;40(10):787–92.CrossRefPubMed Hurley RK, Drummond JL, Viana GC, Galang MT. The effects of environment and cyclic fatigue on the mechanical properties of an indirect composite. J Dent. 2012;40(10):787–92.CrossRefPubMed
18.
Zurück zum Zitat Kassem AS, Atta O, El-Mowafy O. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns. J Prosthodont. 2012;21(1):28–32.CrossRefPubMed Kassem AS, Atta O, El-Mowafy O. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns. J Prosthodont. 2012;21(1):28–32.CrossRefPubMed
19.
Zurück zum Zitat Scotti N, Rota R, Scansetti M, Paolino DS, Chiandussi G, Pasqualini D, et al. Influence of adhesive techniques on fracture resistance of endodontically treated premolars with various residual wall thicknesses. J Prosthet Dent. 2013;110(5):376–82.CrossRefPubMed Scotti N, Rota R, Scansetti M, Paolino DS, Chiandussi G, Pasqualini D, et al. Influence of adhesive techniques on fracture resistance of endodontically treated premolars with various residual wall thicknesses. J Prosthet Dent. 2013;110(5):376–82.CrossRefPubMed
20.
Zurück zum Zitat Shibata S, Gondo R, Araújo É, Mello Roesler, Carlos Rodrigo de, Baratieri LN. Influence of surrounding wall thickness on the fatigue resistance of molars restored with ceramic inlay. Braz Oral Res. 2014; 28. Shibata S, Gondo R, Araújo É, Mello Roesler, Carlos Rodrigo de, Baratieri LN. Influence of surrounding wall thickness on the fatigue resistance of molars restored with ceramic inlay. Braz Oral Res. 2014; 28.
21.
Zurück zum Zitat Slavcheva S, Krejci I, Bortolotto T. Luting of ceramic crowns with a self-adhesive cement: effect of contamination on marginal adaptation and fracture strength. Med Oral Patol Oral Cir Bucal. 2013;18(5):e799–803.CrossRefPubMedPubMedCentral Slavcheva S, Krejci I, Bortolotto T. Luting of ceramic crowns with a self-adhesive cement: effect of contamination on marginal adaptation and fracture strength. Med Oral Patol Oral Cir Bucal. 2013;18(5):e799–803.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Alhasanyah A, Vaidyanathan TK, Flinton RJ. Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns. J Prosthodont. 2013;22(5):383–90.CrossRefPubMed Alhasanyah A, Vaidyanathan TK, Flinton RJ. Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns. J Prosthodont. 2013;22(5):383–90.CrossRefPubMed
23.
Zurück zum Zitat Amaral M, Cesar PF, Bottino MA, Lohbauer U, Valandro LF. Fatigue behavior of Y-TZP ceramic after surface treatments. J Mech Behav Biomed Mater. 2015;57:149–56.CrossRefPubMed Amaral M, Cesar PF, Bottino MA, Lohbauer U, Valandro LF. Fatigue behavior of Y-TZP ceramic after surface treatments. J Mech Behav Biomed Mater. 2015;57:149–56.CrossRefPubMed
24.
Zurück zum Zitat Belli R, Petschelt A, Lohbauer U. Thermal-induced residual stresses affect the fractographic patterns of zirconia-veneer dental prostheses. J Mech Behav Biomed Mater. 2013;21:167–77.CrossRefPubMed Belli R, Petschelt A, Lohbauer U. Thermal-induced residual stresses affect the fractographic patterns of zirconia-veneer dental prostheses. J Mech Behav Biomed Mater. 2013;21:167–77.CrossRefPubMed
25.
Zurück zum Zitat Canullo L, Coelho PG, Bonfante EA. Mechanical testing of thin-walled zirconia abutments. J Appl Oral Sci: Rev FOB. 2013;21(1):20–4.CrossRef Canullo L, Coelho PG, Bonfante EA. Mechanical testing of thin-walled zirconia abutments. J Appl Oral Sci: Rev FOB. 2013;21(1):20–4.CrossRef
26.
Zurück zum Zitat Corazza PH, Feitosa SA, Borges ALS, Della Bona A. Influence of convergence angle of tooth preparation on the fracture resistance of Y-TZP-based all-ceramic restorations. Dent Mater. 2013;29(3):339–47.CrossRefPubMed Corazza PH, Feitosa SA, Borges ALS, Della Bona A. Influence of convergence angle of tooth preparation on the fracture resistance of Y-TZP-based all-ceramic restorations. Dent Mater. 2013;29(3):339–47.CrossRefPubMed
27.
Zurück zum Zitat Foong JKW, Judge RB, Palamara JE, Swain MV. Fracture resistance of titanium and zirconia abutments: an in vitro study. J Prosthet Dent. 2013;109(5):304–12.CrossRefPubMed Foong JKW, Judge RB, Palamara JE, Swain MV. Fracture resistance of titanium and zirconia abutments: an in vitro study. J Prosthet Dent. 2013;109(5):304–12.CrossRefPubMed
28.
Zurück zum Zitat Fraga S, Pereira GKR, Freitas M, Kleverlaan CJ, Valandro LF, May LG. Loading frequencies up to 20Hz as an alternative to accelerate fatigue strength tests in a Y-TZP ceramic. J Mech Behav Biomed Mater. 2016;61:79–86.CrossRefPubMed Fraga S, Pereira GKR, Freitas M, Kleverlaan CJ, Valandro LF, May LG. Loading frequencies up to 20Hz as an alternative to accelerate fatigue strength tests in a Y-TZP ceramic. J Mech Behav Biomed Mater. 2016;61:79–86.CrossRefPubMed
29.
Zurück zum Zitat Guess PC, Bonfante EA, Silva, Nelson RFA, Coelho PG, van Thompson P. Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns. Dent Mater. 2013;29(3):307–16.CrossRefPubMed Guess PC, Bonfante EA, Silva, Nelson RFA, Coelho PG, van Thompson P. Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns. Dent Mater. 2013;29(3):307–16.CrossRefPubMed
30.••
Zurück zum Zitat Rosentritt M, Behr M, Gebhard R, Handel G. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater. 2006;22(2):176–82. Proving important basic knowledge on the topic.CrossRefPubMed Rosentritt M, Behr M, Gebhard R, Handel G. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater. 2006;22(2):176–82. Proving important basic knowledge on the topic.CrossRefPubMed
31.
Zurück zum Zitat Behr M, Hindelang U, Rosentritt M, Lang R, Handel G. Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies. Clin Oral Investig. 2000;4(1):25–30.CrossRefPubMed Behr M, Hindelang U, Rosentritt M, Lang R, Handel G. Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies. Clin Oral Investig. 2000;4(1):25–30.CrossRefPubMed
32.
Zurück zum Zitat Harding AB, Norling BK, Teixeira EC. The effect of surface treatment of the interfacial surface on fatigue-related microtensile bond strength of milled zirconia to veneering porcelain. J Prosthodont. 2012;21(5):346–52.CrossRefPubMed Harding AB, Norling BK, Teixeira EC. The effect of surface treatment of the interfacial surface on fatigue-related microtensile bond strength of milled zirconia to veneering porcelain. J Prosthodont. 2012;21(5):346–52.CrossRefPubMed
33.
Zurück zum Zitat Iijima T, Homma S, Sekine H, Sasaki H, Yajima Y, Yoshinari M. Influence of surface treatment of yttria-stabilized tetragonal zirconia polycrystal with hot isostatic pressing on cyclic fatigue strength. Dent Mater J. 2013;32(2):274–80.CrossRefPubMed Iijima T, Homma S, Sekine H, Sasaki H, Yajima Y, Yoshinari M. Influence of surface treatment of yttria-stabilized tetragonal zirconia polycrystal with hot isostatic pressing on cyclic fatigue strength. Dent Mater J. 2013;32(2):274–80.CrossRefPubMed
34.
Zurück zum Zitat Jiménez-Melendo M, Llena-Blasco O, Bruguera A, Llena-Blasco J, Yáñez-Vico R, García-Calderón M, et al. Mechanical behavior of single-layer ceramized zirconia abutments for dental implant prosthetic rehabilitation. J Clin Exp Dent. 2014;6(5):e485–90.CrossRefPubMedPubMedCentral Jiménez-Melendo M, Llena-Blasco O, Bruguera A, Llena-Blasco J, Yáñez-Vico R, García-Calderón M, et al. Mechanical behavior of single-layer ceramized zirconia abutments for dental implant prosthetic rehabilitation. J Clin Exp Dent. 2014;6(5):e485–90.CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat Mitsias ME, van Thompson P, Pines M, Silva, Nelson RFA. Reliability and failure modes of two Y-TZP abutment designs. Int J Prosthodont. 2015;28(1):75–8.CrossRefPubMed Mitsias ME, van Thompson P, Pines M, Silva, Nelson RFA. Reliability and failure modes of two Y-TZP abutment designs. Int J Prosthodont. 2015;28(1):75–8.CrossRefPubMed
36.
Zurück zum Zitat Nicolaisen MH, Bahrami G, Finlay S, Isidor F. Comparison of fatigue resistance and failure modes between metal-ceramic and all-ceramic crowns by cyclic loading in water. J Dent. 2014;42(12):1613–20.CrossRefPubMed Nicolaisen MH, Bahrami G, Finlay S, Isidor F. Comparison of fatigue resistance and failure modes between metal-ceramic and all-ceramic crowns by cyclic loading in water. J Dent. 2014;42(12):1613–20.CrossRefPubMed
37.
Zurück zum Zitat Noqueira LB, Moura CD, Francischone CE, Valente VS, Alencar SM, Moura WL, et al. Fracture strength of implant-supported ceramic crowns with customized zirconia abutments: screw retained vs. cement retained. J Prosthodont. 2016;25(1):49–53. Noqueira LB, Moura CD, Francischone CE, Valente VS, Alencar SM, Moura WL, et al. Fracture strength of implant-supported ceramic crowns with customized zirconia abutments: screw retained vs. cement retained. J Prosthodont. 2016;25(1):49–53.
38.
Zurück zum Zitat Nossair SA, Aboushelib MN, Morsi TS. Fracture and fatigue resistance of cemented versus fused CAD-on veneers over customized zirconia implant abutments. J Prosthodont. 2015. Nossair SA, Aboushelib MN, Morsi TS. Fracture and fatigue resistance of cemented versus fused CAD-on veneers over customized zirconia implant abutments. J Prosthodont. 2015.
39.
Zurück zum Zitat Nothdurft FP, Neumann K, Knauber AW. Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry. Clin Oral Investig. 2014;18(5):1467–72.CrossRefPubMed Nothdurft FP, Neumann K, Knauber AW. Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry. Clin Oral Investig. 2014;18(5):1467–72.CrossRefPubMed
40.
Zurück zum Zitat Oblak C, Verdenik I, Swain MV, Kosmac T. Survival-rate analysis of surface treated dental zirconia (Y-TZP) ceramics. J Mater Sci Mater Med. 2014;25(10):2255–64.CrossRefPubMed Oblak C, Verdenik I, Swain MV, Kosmac T. Survival-rate analysis of surface treated dental zirconia (Y-TZP) ceramics. J Mater Sci Mater Med. 2014;25(10):2255–64.CrossRefPubMed
41.
Zurück zum Zitat Oderich E, Boff LL, Cardoso AC, Magne P. Fatigue resistance and failure mode of adhesively restored custom implant zirconia abutments. Clin Oral Implants Res. 2012;23(12):1360–8.CrossRefPubMed Oderich E, Boff LL, Cardoso AC, Magne P. Fatigue resistance and failure mode of adhesively restored custom implant zirconia abutments. Clin Oral Implants Res. 2012;23(12):1360–8.CrossRefPubMed
42.
Zurück zum Zitat Pereira GKR, Silvestri T, Amaral M, Rippe MP, Kleverlaan CJ, Valandro LF. Fatigue limit of polycrystalline zirconium oxide ceramics: effect of grinding and low-temperature aging. J Mech Behav Biomed Mater. 2016;61:45–54.CrossRefPubMed Pereira GKR, Silvestri T, Amaral M, Rippe MP, Kleverlaan CJ, Valandro LF. Fatigue limit of polycrystalline zirconium oxide ceramics: effect of grinding and low-temperature aging. J Mech Behav Biomed Mater. 2016;61:45–54.CrossRefPubMed
43.
Zurück zum Zitat Rueda AO, Anglada M, Jimenez-Pique E. Contact fatigue of veneer feldspathic porcelain on dental zirconia. Dent Mater. 2015;31(3):217–24.CrossRefPubMed Rueda AO, Anglada M, Jimenez-Pique E. Contact fatigue of veneer feldspathic porcelain on dental zirconia. Dent Mater. 2015;31(3):217–24.CrossRefPubMed
44.
Zurück zum Zitat Tsumita M, Kokubo Y, Kano T, Sasaki K. Effect of fatigue loading on the screw joint stability of zirconium abutment. J Prosthodont Res. 2013;57(3):219–23.CrossRefPubMed Tsumita M, Kokubo Y, Kano T, Sasaki K. Effect of fatigue loading on the screw joint stability of zirconium abutment. J Prosthodont Res. 2013;57(3):219–23.CrossRefPubMed
45.
Zurück zum Zitat Batalha-Silva S, de Andrada MA, Caldeira, Maia HP, Magne P. Fatigue resistance and crack propensity of large MOD composite resin restorations: direct versus CAD/CAM inlays. Dent Mater. 2013;29(3):324–31.CrossRefPubMed Batalha-Silva S, de Andrada MA, Caldeira, Maia HP, Magne P. Fatigue resistance and crack propensity of large MOD composite resin restorations: direct versus CAD/CAM inlays. Dent Mater. 2013;29(3):324–31.CrossRefPubMed
46.•
Zurück zum Zitat Belli R, Petschelt A, Lohbauer U. Are linear elastic material properties relevant predictors of the cyclic fatigue resistance of dental resin composites? Dent Mater. 2014;30(4):381–91. Proving important basic knowledge on the topic.CrossRefPubMed Belli R, Petschelt A, Lohbauer U. Are linear elastic material properties relevant predictors of the cyclic fatigue resistance of dental resin composites? Dent Mater. 2014;30(4):381–91. Proving important basic knowledge on the topic.CrossRefPubMed
47.
Zurück zum Zitat Belli R, Geinzer E, Muschweck A, Petschelt A, Lohbauer U. Mechanical fatigue degradation of ceramics versus resin composites for dental restorations. Dent Mater. 2014;30(4):424–32.CrossRefPubMed Belli R, Geinzer E, Muschweck A, Petschelt A, Lohbauer U. Mechanical fatigue degradation of ceramics versus resin composites for dental restorations. Dent Mater. 2014;30(4):424–32.CrossRefPubMed
48.
Zurück zum Zitat Bijelic-Donova J, Garoushi S, Vallittu PK, Lassila LVJ. Mechanical properties, fracture resistance, and fatigue limits of short fiber reinforced dental composite resin. J Prosthet Dent. 2016;115(1):95–102.CrossRefPubMed Bijelic-Donova J, Garoushi S, Vallittu PK, Lassila LVJ. Mechanical properties, fracture resistance, and fatigue limits of short fiber reinforced dental composite resin. J Prosthet Dent. 2016;115(1):95–102.CrossRefPubMed
49.
Zurück zum Zitat Bonfante EA, Suzuki M, Lorenzoni FC, Sena LA, Hirata R, Bonfante G, et al. Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns. Dent Mater. 2015;31(8):e168–77.CrossRefPubMed Bonfante EA, Suzuki M, Lorenzoni FC, Sena LA, Hirata R, Bonfante G, et al. Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns. Dent Mater. 2015;31(8):e168–77.CrossRefPubMed
50.
Zurück zum Zitat Carvalho AO, Bruzi G, Giannini M, Magne P. Fatigue resistance of CAD/CAM complete crowns with a simplified cementation process. J Prosthet Dent. 2014;111(4):310–7.CrossRefPubMed Carvalho AO, Bruzi G, Giannini M, Magne P. Fatigue resistance of CAD/CAM complete crowns with a simplified cementation process. J Prosthet Dent. 2014;111(4):310–7.CrossRefPubMed
51.
Zurück zum Zitat Agnol D, Cezarotto RJ, Ghiggi PC, Paranhos MPG, Borges GA, Burnett LH, et al. Influence of resin cements on cuspal deflection and fracture load of endodontically-treated teeth restored with composite inlays. Acta Odontol Scand. 2013;71(3-4):664–70.CrossRef Agnol D, Cezarotto RJ, Ghiggi PC, Paranhos MPG, Borges GA, Burnett LH, et al. Influence of resin cements on cuspal deflection and fracture load of endodontically-treated teeth restored with composite inlays. Acta Odontol Scand. 2013;71(3-4):664–70.CrossRef
52.
Zurück zum Zitat Guess PC, Vagkopoulou T, Zhang Y, Wolkewitz M, Strub JR. Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue. J Dent. 2014;42(2):199–209.CrossRefPubMed Guess PC, Vagkopoulou T, Zhang Y, Wolkewitz M, Strub JR. Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue. J Dent. 2014;42(2):199–209.CrossRefPubMed
53.
Zurück zum Zitat Iwasaki N, Takahashi H, Koottathape N, Kanehira M, Finger WJ, Sasaki K. Texture of composite resins exposed to two- and three-body wear in vitro. J Contemp Dent Pract. 2014;15(2):232–41.CrossRefPubMed Iwasaki N, Takahashi H, Koottathape N, Kanehira M, Finger WJ, Sasaki K. Texture of composite resins exposed to two- and three-body wear in vitro. J Contemp Dent Pract. 2014;15(2):232–41.CrossRefPubMed
54.
Zurück zum Zitat Lawson NC, Burgess JO. Wear of nanofilled dental composites at varying filler concentrations. J Biomed Mater Res B Appl Biomater. 2015;103(2):424–9.CrossRefPubMed Lawson NC, Burgess JO. Wear of nanofilled dental composites at varying filler concentrations. J Biomed Mater Res B Appl Biomater. 2015;103(2):424–9.CrossRefPubMed
55.
Zurück zum Zitat Magne P, Boff LL, Oderich E, Cardoso AC. Computer-aided-design/computer-assisted-manufactured adhesive restoration of molars with a compromised cusp: effect of fiber-reinforced immediate dentin sealing and cusp overlap on fatigue strength. J Esthet Restor Dent. 2012;24(2):135–46.CrossRefPubMed Magne P, Boff LL, Oderich E, Cardoso AC. Computer-aided-design/computer-assisted-manufactured adhesive restoration of molars with a compromised cusp: effect of fiber-reinforced immediate dentin sealing and cusp overlap on fatigue strength. J Esthet Restor Dent. 2012;24(2):135–46.CrossRefPubMed
56.
Zurück zum Zitat Majd B, Majd H, Porter JA, Romberg E, Arola D. Degradation in the fatigue strength of dentin by diamond bur preparations: importance of cutting direction. J Biomed Mater Res B Appl Biomater. 2016;104(1):39–49.CrossRefPubMed Majd B, Majd H, Porter JA, Romberg E, Arola D. Degradation in the fatigue strength of dentin by diamond bur preparations: importance of cutting direction. J Biomed Mater Res B Appl Biomater. 2016;104(1):39–49.CrossRefPubMed
57.
Zurück zum Zitat Martins LM, Bonfante EA, Zavanelli RA, Freitas AC, Silva, Nelson RFA, et al. Fatigue reliability of 3 single-unit implant-abutment designs. Implant Dent. 2012;21(1):67–71.CrossRefPubMed Martins LM, Bonfante EA, Zavanelli RA, Freitas AC, Silva, Nelson RFA, et al. Fatigue reliability of 3 single-unit implant-abutment designs. Implant Dent. 2012;21(1):67–71.CrossRefPubMed
58.
Zurück zum Zitat Mühlemann S, Truninger TC, Stawarczyk B, Hämmerle CHF, Sailer I. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging. Clin Oral Implants Res. 2014;25(1):74–81.CrossRefPubMed Mühlemann S, Truninger TC, Stawarczyk B, Hämmerle CHF, Sailer I. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging. Clin Oral Implants Res. 2014;25(1):74–81.CrossRefPubMed
59.
Zurück zum Zitat Mutluay MM, Yahyazadehfar M, Ryou H, Majd H, Do D, Arola D. Fatigue of the resin-dentin interface: a new approach for evaluating the durability of dentin bonds. Dent Mater. 2013;29(4):437–49.CrossRefPubMedPubMedCentral Mutluay MM, Yahyazadehfar M, Ryou H, Majd H, Do D, Arola D. Fatigue of the resin-dentin interface: a new approach for evaluating the durability of dentin bonds. Dent Mater. 2013;29(4):437–49.CrossRefPubMedPubMedCentral
60.
Zurück zum Zitat Mutluay MM, Zhang K, Ryou H, Yahyazadehfar M, Majd H, Xu HHK, et al. On the fatigue behavior of resin-dentin bonds after degradation by biofilm. J Mech Behav Biomed Mater. 2013;18:219–31.CrossRefPubMed Mutluay MM, Zhang K, Ryou H, Yahyazadehfar M, Majd H, Xu HHK, et al. On the fatigue behavior of resin-dentin bonds after degradation by biofilm. J Mech Behav Biomed Mater. 2013;18:219–31.CrossRefPubMed
61.
Zurück zum Zitat Pameijer CH, Garcia-Godoy F, Morrow BR, Jefferies SR. Flexural strength and flexural fatigue properties of resin-modified glass ionomers. J Clin Dent. 2015;26(1):23–7.PubMed Pameijer CH, Garcia-Godoy F, Morrow BR, Jefferies SR. Flexural strength and flexural fatigue properties of resin-modified glass ionomers. J Clin Dent. 2015;26(1):23–7.PubMed
62.
Zurück zum Zitat Pérez MA. Life prediction of different commercial dental implants as influence by uncertainties in their fatigue material properties and loading conditions. Comput Methods Prog Biomed. 2012;108(3):1277–86.CrossRef Pérez MA. Life prediction of different commercial dental implants as influence by uncertainties in their fatigue material properties and loading conditions. Comput Methods Prog Biomed. 2012;108(3):1277–86.CrossRef
63.
Zurück zum Zitat Rack T, Rack T, Zabler S, Rack A, Riesemeier H, Nelson K. An in vitro pilot study of abutment stability during loading in new and fatigue-loaded conical dental implants using synchrotron-based radiography. Int J Oral Maxillofac Implants. 2013;28(1):44–50.CrossRefPubMed Rack T, Rack T, Zabler S, Rack A, Riesemeier H, Nelson K. An in vitro pilot study of abutment stability during loading in new and fatigue-loaded conical dental implants using synchrotron-based radiography. Int J Oral Maxillofac Implants. 2013;28(1):44–50.CrossRefPubMed
64.
Zurück zum Zitat Ramírez-Sebastià A, Bortolotto T, Cattani-Lorente M, Giner L, Roig M, Krejci I. Adhesive restoration of anterior endodontically treated teeth: influence of post length on fracture strength. Clin Oral Investig. 2014;18(2):545–54.CrossRefPubMed Ramírez-Sebastià A, Bortolotto T, Cattani-Lorente M, Giner L, Roig M, Krejci I. Adhesive restoration of anterior endodontically treated teeth: influence of post length on fracture strength. Clin Oral Investig. 2014;18(2):545–54.CrossRefPubMed
65.
Zurück zum Zitat Rocca GT, Gregor L, Sandoval MJ, Krejci I, Dietschi D. In vitro evaluation of marginal and internal adaptation after occlusal stressing of indirect class II composite restorations with different resinous bases and interface treatments. “Post-fatigue adaptation of indirect composite restorations”. Clin Oral Investig. 2012;16(5):1385–93.CrossRefPubMed Rocca GT, Gregor L, Sandoval MJ, Krejci I, Dietschi D. In vitro evaluation of marginal and internal adaptation after occlusal stressing of indirect class II composite restorations with different resinous bases and interface treatments. “Post-fatigue adaptation of indirect composite restorations”. Clin Oral Investig. 2012;16(5):1385–93.CrossRefPubMed
66.
Zurück zum Zitat Salaverry A, Borges GA, Mota EG, Burnett Júnior LH, Spohr AM. Effect of resin cements and aging on cuspal deflection and fracture resistance of teeth restored with composite resin inlays. J Adhes Dent. 2013;15(6):561–8.PubMed Salaverry A, Borges GA, Mota EG, Burnett Júnior LH, Spohr AM. Effect of resin cements and aging on cuspal deflection and fracture resistance of teeth restored with composite resin inlays. J Adhes Dent. 2013;15(6):561–8.PubMed
67.
Zurück zum Zitat Shembish FA, Tong H, Kaizer M, Janal MN, van Thompson P, Opdam NJ et al. Fatigue resistance of CAD/CAM resin composite molar crowns. Dent Mater. 2016. Shembish FA, Tong H, Kaizer M, Janal MN, van Thompson P, Opdam NJ et al. Fatigue resistance of CAD/CAM resin composite molar crowns. Dent Mater. 2016.
68.
Zurück zum Zitat Shemtov-Yona K, Rittel D. On the mechanical integrity of retrieved dental implants. J Mech Behav Biomed Mater. 2015;49:290–9.CrossRefPubMed Shemtov-Yona K, Rittel D. On the mechanical integrity of retrieved dental implants. J Mech Behav Biomed Mater. 2015;49:290–9.CrossRefPubMed
69.
Zurück zum Zitat Shemtov-Yona K, Rittel D, Dorogoy A. Mechanical assessment of grit blasting surface treatments of dental implants. J Mech Behav Biomed Mater. 2014;39:375–90.CrossRefPubMed Shemtov-Yona K, Rittel D, Dorogoy A. Mechanical assessment of grit blasting surface treatments of dental implants. J Mech Behav Biomed Mater. 2014;39:375–90.CrossRefPubMed
70.
Zurück zum Zitat Silva NR, Teixeira HS, Silveira LM, Bonfante EA, Coelho PG, van Thompson P. Reliability and failure modes of a hybrid ceramic abutment prototype. J Prosthodont. 2016. Silva NR, Teixeira HS, Silveira LM, Bonfante EA, Coelho PG, van Thompson P. Reliability and failure modes of a hybrid ceramic abutment prototype. J Prosthodont. 2016.
71.
Zurück zum Zitat Skouridou N, Pollington S, Rosentritt M, Tsitrou E. Fracture strength of minimally prepared all-ceramic CEREC crowns after simulating 5 years of service. Dent Mater. 2013;29(6):e70–7.CrossRefPubMed Skouridou N, Pollington S, Rosentritt M, Tsitrou E. Fracture strength of minimally prepared all-ceramic CEREC crowns after simulating 5 years of service. Dent Mater. 2013;29(6):e70–7.CrossRefPubMed
72.
Zurück zum Zitat Stappert CFJ, Baldassarri M, Zhang Y, Hänssler F, Rekow ED, Van Thompson P. Reliability and fatigue failure modes of implant-supported aluminum-oxide fixed dental prostheses. Clin Oral Implants Res. 2012;23(10):1173–80.CrossRefPubMed Stappert CFJ, Baldassarri M, Zhang Y, Hänssler F, Rekow ED, Van Thompson P. Reliability and fatigue failure modes of implant-supported aluminum-oxide fixed dental prostheses. Clin Oral Implants Res. 2012;23(10):1173–80.CrossRefPubMed
73.
Zurück zum Zitat Stimmelmayr M, Edelhoff D, Güth J, Erdelt K, Happe A, Beuer F. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study. Dent Mater. 2012;28(12):1215–20.CrossRefPubMed Stimmelmayr M, Edelhoff D, Güth J, Erdelt K, Happe A, Beuer F. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study. Dent Mater. 2012;28(12):1215–20.CrossRefPubMed
74.
Zurück zum Zitat Stimmelmayr M, Sagerer S, Erdelt K, Beuer F. In vitro fatigue and fracture strength testing of one-piece zirconia implant abutments and zirconia implant abutments connected to titanium cores. Int J Oral Maxillofac Implants. 2013;28(2):488–93.CrossRefPubMed Stimmelmayr M, Sagerer S, Erdelt K, Beuer F. In vitro fatigue and fracture strength testing of one-piece zirconia implant abutments and zirconia implant abutments connected to titanium cores. Int J Oral Maxillofac Implants. 2013;28(2):488–93.CrossRefPubMed
75.
Zurück zum Zitat Stona D, Burnett LH, Mota EG, Spohr AM. Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments. J Am Dent Assoc (1939). 2015;146(7):501–7.CrossRef Stona D, Burnett LH, Mota EG, Spohr AM. Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments. J Am Dent Assoc (1939). 2015;146(7):501–7.CrossRef
76.
Zurück zum Zitat Takano T, Tasaka A, Yoshinari M, Sakurai K. Fatigue strength of Ce-TZP/Al2O3 nanocomposite with different surfaces. J Dent Res. 2012;91(8):800–4.CrossRefPubMed Takano T, Tasaka A, Yoshinari M, Sakurai K. Fatigue strength of Ce-TZP/Al2O3 nanocomposite with different surfaces. J Dent Res. 2012;91(8):800–4.CrossRefPubMed
77.
Zurück zum Zitat Tiossi R, Gomes ÉA, Faria ACL, Rodrigues RCS, Ribeiro RF. Influence of cyclic fatigue in water on screw torque loss of long-span one-piece implant-supported zirconia frameworks. J Prosthodont. 2015. Tiossi R, Gomes ÉA, Faria ACL, Rodrigues RCS, Ribeiro RF. Influence of cyclic fatigue in water on screw torque loss of long-span one-piece implant-supported zirconia frameworks. J Prosthodont. 2015.
78.
Zurück zum Zitat Wandscher VF, Bergoli CD, de Oliveira AF, Kaizer OB, Souto Borges AL, Limberguer IF, et al. Fatigue surviving, fracture resistance, shear stress and finite element analysis of glass fiber posts with different diameters. J Mech Behav Biomed Mater. 2015;43:69–77.CrossRefPubMed Wandscher VF, Bergoli CD, de Oliveira AF, Kaizer OB, Souto Borges AL, Limberguer IF, et al. Fatigue surviving, fracture resistance, shear stress and finite element analysis of glass fiber posts with different diameters. J Mech Behav Biomed Mater. 2015;43:69–77.CrossRefPubMed
79.
Zurück zum Zitat Wang R, Tao J, Yu B, Dai L. Characterization of multiwalled carbon nanotube-polymethyl methacrylate composite resins as denture base materials. J Prosthet Dent. 2014;111(4):318–26.CrossRefPubMed Wang R, Tao J, Yu B, Dai L. Characterization of multiwalled carbon nanotube-polymethyl methacrylate composite resins as denture base materials. J Prosthet Dent. 2014;111(4):318–26.CrossRefPubMed
80.
Zurück zum Zitat Wong TL, Botelho MG. The fatigue bond strength of fixed-fixed versus cantilever resin-bonded partial fixed dental prostheses. J Prosthet Dent. 2014;111(2):136–41.CrossRefPubMed Wong TL, Botelho MG. The fatigue bond strength of fixed-fixed versus cantilever resin-bonded partial fixed dental prostheses. J Prosthet Dent. 2014;111(2):136–41.CrossRefPubMed
81.
Zurück zum Zitat Xia D, Lin H, Yuan S, Bai W, Zheng G. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values. Bio-Med Mater Eng. 2014;24(6):2143–9. Xia D, Lin H, Yuan S, Bai W, Zheng G. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values. Bio-Med Mater Eng. 2014;24(6):2143–9.
82.
Zurück zum Zitat Yahyazadehfar M, Mutluay MM, Majd H, Ryou H, Arola D. Fatigue of the resin-enamel bonded interface and the mechanisms of failure. J Mech Behav Biomed Mater. 2013;21:121–32.CrossRefPubMed Yahyazadehfar M, Mutluay MM, Majd H, Ryou H, Arola D. Fatigue of the resin-enamel bonded interface and the mechanisms of failure. J Mech Behav Biomed Mater. 2013;21:121–32.CrossRefPubMed
83.
Zurück zum Zitat Yao K, Kao H, Cheng C, Fang H, Huang C, Hsu M. The potential risk of conical implant-abutment connections: the antirotational ability of Cowell implant system. Clin Implant Dent Relat Res. 2015;17(6):1208–16.CrossRefPubMed Yao K, Kao H, Cheng C, Fang H, Huang C, Hsu M. The potential risk of conical implant-abutment connections: the antirotational ability of Cowell implant system. Clin Implant Dent Relat Res. 2015;17(6):1208–16.CrossRefPubMed
84.
Zurück zum Zitat Zamboni SC, Nogueira L, Bottino MA, Sobrinho LC, Valandro LF. The effect of mechanical loading on the cusp defection of premolars restored with direct and indirect techniques. J Contemp Dent Pract. 2014;15(1):75–81.CrossRefPubMed Zamboni SC, Nogueira L, Bottino MA, Sobrinho LC, Valandro LF. The effect of mechanical loading on the cusp defection of premolars restored with direct and indirect techniques. J Contemp Dent Pract. 2014;15(1):75–81.CrossRefPubMed
85.
Zurück zum Zitat Zhao K, Wei Y, Pan Y, Zhang X, Swain MV, Guess PC. Influence of veneer and cyclic loading on failure behavior of lithium disilicate glass-ceramic molar crowns. Dent Mater. 2014;30(2):164–71.CrossRefPubMed Zhao K, Wei Y, Pan Y, Zhang X, Swain MV, Guess PC. Influence of veneer and cyclic loading on failure behavior of lithium disilicate glass-ceramic molar crowns. Dent Mater. 2014;30(2):164–71.CrossRefPubMed
86.
Zurück zum Zitat Zicari F, van Meerbeek B, Scotti R, Naert I. Effect of fibre post length and adhesive strategy on fracture resistance of endodontically treated teeth after fatigue loading. J Dent. 2012;40(4):312–21.CrossRefPubMed Zicari F, van Meerbeek B, Scotti R, Naert I. Effect of fibre post length and adhesive strategy on fracture resistance of endodontically treated teeth after fatigue loading. J Dent. 2012;40(4):312–21.CrossRefPubMed
87.
Zurück zum Zitat Zicari F, van Meerbeek B, Scotti R, Naert I. Effect of ferrule and post placement on fracture resistance of endodontically treated teeth after fatigue loading. J Dent. 2013;41(3):207–15.CrossRefPubMed Zicari F, van Meerbeek B, Scotti R, Naert I. Effect of ferrule and post placement on fracture resistance of endodontically treated teeth after fatigue loading. J Dent. 2013;41(3):207–15.CrossRefPubMed
88.••
Zurück zum Zitat Rosentritt M, Siavikis G, Behr M, Kolbeck C, Handel G. Approach for valuating the significance of laboratory simulation. J Dent. 2008;36(12):1048–53. Proving important basic knowledge on the topic.CrossRefPubMed Rosentritt M, Siavikis G, Behr M, Kolbeck C, Handel G. Approach for valuating the significance of laboratory simulation. J Dent. 2008;36(12):1048–53. Proving important basic knowledge on the topic.CrossRefPubMed
89.••
Zurück zum Zitat Rosentritt M, Behr M, van der Zel, Jef M, Feilzer AJ. Approach for valuating the influence of laboratory simulation. Dent Mater. 2009;25(3):348–52. Proving important basic knowledge on the topic.CrossRefPubMed Rosentritt M, Behr M, van der Zel, Jef M, Feilzer AJ. Approach for valuating the influence of laboratory simulation. Dent Mater. 2009;25(3):348–52. Proving important basic knowledge on the topic.CrossRefPubMed
90.
Zurück zum Zitat Lin J, Sun M, Zheng Z, Shinya A, Han J, Lin H, et al. Effects of rotating fatigue on the mechanical properties of microhybrid and nanofiller-containing composites. Dent Mater J. 2013;32(3):476–83.CrossRefPubMed Lin J, Sun M, Zheng Z, Shinya A, Han J, Lin H, et al. Effects of rotating fatigue on the mechanical properties of microhybrid and nanofiller-containing composites. Dent Mater J. 2013;32(3):476–83.CrossRefPubMed
91.
Zurück zum Zitat Ruben JL, Roeters FJM, Montagner AF, Huysmans MCDNJM. A multifunctional device to simulate oral ageing: the “Rub&Roll”. J Mech Behav Biomed Mater. 2014;30:75–82.CrossRefPubMed Ruben JL, Roeters FJM, Montagner AF, Huysmans MCDNJM. A multifunctional device to simulate oral ageing: the “Rub&Roll”. J Mech Behav Biomed Mater. 2014;30:75–82.CrossRefPubMed
92.
Zurück zum Zitat ISO 14801:2007. Dentistry —implants—dynamic fatigue test for endosseous dental implants. Berlin: Beuth Verlag; 2007. ISO 14801:2007. Dentistry —implants—dynamic fatigue test for endosseous dental implants. Berlin: Beuth Verlag; 2007.
93.•
Zurück zum Zitat Bonfante EA, Coelho PG. A critical perspective on mechanical testing of implants and prostheses. Adv Dent Res. 2016;28(1):18–27. Proving important basic knowledge on the topic.CrossRefPubMed Bonfante EA, Coelho PG. A critical perspective on mechanical testing of implants and prostheses. Adv Dent Res. 2016;28(1):18–27. Proving important basic knowledge on the topic.CrossRefPubMed
94.
Zurück zum Zitat de Gee AJ, Pallav P, Davidson CL. Effect of abrasion medium on wear of stress-bearing composites and amalgam in vitro. J Dent Res. 1986;65(5):654–8. Proving important basic knowledge on the topic.CrossRefPubMed de Gee AJ, Pallav P, Davidson CL. Effect of abrasion medium on wear of stress-bearing composites and amalgam in vitro. J Dent Res. 1986;65(5):654–8. Proving important basic knowledge on the topic.CrossRefPubMed
95.••
Zurück zum Zitat Lohbauer U, Krämer N, Petschelt A, Frankenberger R. Correlation of in vitro fatigue data and in vivo clinical performance of a glass ceramic material. Dent Mater. 2008;24(1):39–44. Proving important basic knowledge on the topic.CrossRefPubMed Lohbauer U, Krämer N, Petschelt A, Frankenberger R. Correlation of in vitro fatigue data and in vivo clinical performance of a glass ceramic material. Dent Mater. 2008;24(1):39–44. Proving important basic knowledge on the topic.CrossRefPubMed
96.
Zurück zum Zitat Belli R, Petschelt A, Hofner B, Hajtó J, Scherrer SS, Lohbauer U. Fracture rates and lifetime estimations of CAD/CAM all-ceramic restorations. J Dent Res. 2016;95(1):67–73.CrossRefPubMed Belli R, Petschelt A, Hofner B, Hajtó J, Scherrer SS, Lohbauer U. Fracture rates and lifetime estimations of CAD/CAM all-ceramic restorations. J Dent Res. 2016;95(1):67–73.CrossRefPubMed
97.••
Zurück zum Zitat Bayne SC. Correlation of clinical performance with ‘in vitro tests’ of restorative dental materials that use polymer-based matrices. Dent Mater. 2012;28(1):52–71. Proving important basic knowledge on the topic.CrossRefPubMed Bayne SC. Correlation of clinical performance with ‘in vitro tests’ of restorative dental materials that use polymer-based matrices. Dent Mater. 2012;28(1):52–71. Proving important basic knowledge on the topic.CrossRefPubMed
98.
Zurück zum Zitat Sundarapandian V. New results on the parametric stability of nonlinear systems. Math Comput Model. 2005;2005(43):9–15. Sundarapandian V. New results on the parametric stability of nonlinear systems. Math Comput Model. 2005;2005(43):9–15.
99.•
Zurück zum Zitat Della Bona A, Wozniak WT, Watts DC. International dental standards—order out of chaos? Dent Mater. 2011;27(7):619–21. Proving important basic knowledge on the topic.CrossRefPubMed Della Bona A, Wozniak WT, Watts DC. International dental standards—order out of chaos? Dent Mater. 2011;27(7):619–21. Proving important basic knowledge on the topic.CrossRefPubMed
100.
Zurück zum Zitat Scherrer SS, Quinn JB, Quinn GD, Wiskott HWA. Fractographic ceramic failure analysis using the replica technique. Dent Mater. 2007;23(11):1397–404.CrossRefPubMedPubMedCentral Scherrer SS, Quinn JB, Quinn GD, Wiskott HWA. Fractographic ceramic failure analysis using the replica technique. Dent Mater. 2007;23(11):1397–404.CrossRefPubMedPubMedCentral
Metadaten
Titel
A Critical Evaluation of Fatigue Studies for Restorative Materials in Dentistry
verfasst von
Martin Rosentritt
Michael Behr
Verena Preis
Publikationsdatum
01.09.2016
Verlag
Springer International Publishing
Erschienen in
Current Oral Health Reports / Ausgabe 3/2016
Elektronische ISSN: 2196-3002
DOI
https://doi.org/10.1007/s40496-016-0097-8

Weitere Artikel der Ausgabe 3/2016

Current Oral Health Reports 3/2016 Zur Ausgabe

Dental Restorative Materials (M Özcan, Section Editor)

Materials and Processes for CAD/CAM Complete Denture Fabrication

Dental Public Health (R Collins, Section Editor)

The “New” Genetics and Its Impact on Oral Care Delivery

Dental Restorative Materials (M Özcan, Section Editor)

Ceramic-Reinforced Polymers: CAD/CAM Hybrid Restorative Materials

Dental Public Health (R Collins, Section Editor)

Geriatric Oral Health Care Delivery in the United States of America

Systemic Diseases (M Bartold, Section Editor)

Modifiable Risk Factors for Periodontitis and Diabetes

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.