Skip to main content
Erschienen in: Diabetology International 4/2019

05.07.2019 | Case Report

A diabetic patient in whom Hb Weesp was incidentally detected when her HbA1c level was measured

verfasst von: Tomomi Hatayama, Fumio Umeda, Teruaki Yamauchi, Hiroshi Ideguchi

Erschienen in: Diabetology International | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

The level of glycated hemoglobin A1c (HbA1c) is widely used to monitor long-term glycemic control in patients with diabetes mellitus. There are more than 30 methods for measuring HbA1c levels. In recent times, high-performance liquid chromatography (HPLC) has become the most commonly used method in Japan. However, HPLC-based HbA1c level measurements do not accurately reflect glycemic control in the presence of Hb variants. We report the case of a patient with type 2 diabetes mellitus, who was incidentally found to having an extremely rare Hb variant. A 69-year-old Japanese female visited our clinic and was diagnosed with diabetes mellitus. Her HbA1c level, which was measured using HPLC at our clinic, could not be determined. DNA sequencing revealed a heterozygous mutation in the α1 globin gene (HBA1: c.301C > T, p.Leu101Phe). Hb Weesp was detected. Many Hb variants have been reported; however, to the best of our knowledge, this is only the second report about Hb Weesp in the world and the first from Japan. Clinicians should consider the possibility of Hb variants in cases in which abnormal elution patterns are detected during the measurement of HbA1c using HPLC.
Literatur
1.
Zurück zum Zitat Inoue K, Nakashima M, Masunaga S, Tanigaki N, Hatoyama Y, Nagashio H, Baba T, Nohara M. A case of HbE-Saskatoon and false-low HbA1c value determined by ion-exchange high-performance liquid chromatography (HPLC). Igakukensa. 2018;67(4):575–9. Inoue K, Nakashima M, Masunaga S, Tanigaki N, Hatoyama Y, Nagashio H, Baba T, Nohara M. A case of HbE-Saskatoon and false-low HbA1c value determined by ion-exchange high-performance liquid chromatography (HPLC). Igakukensa. 2018;67(4):575–9.
2.
Zurück zum Zitat Iizuka K, Mizuno M, Niwa H, Takeda J. A rare case of variant hemoglobin (Hb Yahata) suspected based on inconsistent plasma glucose and HbA1c levels. Intern Med. 2015;54(14):1771–5.CrossRef Iizuka K, Mizuno M, Niwa H, Takeda J. A rare case of variant hemoglobin (Hb Yahata) suspected based on inconsistent plasma glucose and HbA1c levels. Intern Med. 2015;54(14):1771–5.CrossRef
3.
Zurück zum Zitat International Expert Committee. International Expert Committee report on the role of A1C assay in the diagnosis of diabetes. Diabetes Care. 2009;32(7):1327–34.CrossRef International Expert Committee. International Expert Committee report on the role of A1C assay in the diagnosis of diabetes. Diabetes Care. 2009;32(7):1327–34.CrossRef
4.
Zurück zum Zitat Bry L, Chen PC, Sack DB. Effect of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin. Clin Chem. 2001;47:153–63.PubMed Bry L, Chen PC, Sack DB. Effect of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin. Clin Chem. 2001;47:153–63.PubMed
5.
Zurück zum Zitat Van Zweiten R, Veldthuis M, Delzenne B, Berfhuis J, Groen J, Ait Ichou F, Clifford E, Harteveld CL, Stroobants AK. Hemoglobin analyses in the Netherlands reveal more than 80 different variants including six novel ones. Hemoglobin. 2014;38(1):1–7.CrossRef Van Zweiten R, Veldthuis M, Delzenne B, Berfhuis J, Groen J, Ait Ichou F, Clifford E, Harteveld CL, Stroobants AK. Hemoglobin analyses in the Netherlands reveal more than 80 different variants including six novel ones. Hemoglobin. 2014;38(1):1–7.CrossRef
6.
Zurück zum Zitat Bots M, Stroobants AK, Delzenne B, Soeters MR, de Vries JE, Weykamp CW, Norg RJ, Veldthuis M, van Zwieten R. Two novel haemoglobin variants that affect haemoglobin A1c measurement by ion-exchange chromatography. Clin Chem Lab Med. 2015;53(9):1465–71.CrossRef Bots M, Stroobants AK, Delzenne B, Soeters MR, de Vries JE, Weykamp CW, Norg RJ, Veldthuis M, van Zwieten R. Two novel haemoglobin variants that affect haemoglobin A1c measurement by ion-exchange chromatography. Clin Chem Lab Med. 2015;53(9):1465–71.CrossRef
7.
Zurück zum Zitat John WG. Glycated haemoglobin analysis. Ann Clin Biochem. 1997;34(Pt1):17–31.CrossRef John WG. Glycated haemoglobin analysis. Ann Clin Biochem. 1997;34(Pt1):17–31.CrossRef
9.
Zurück zum Zitat Yamashiro Y, Hattori Y. Hemoglobinopathies in Japan: characteristics and comparison with those of other ethnic groups. Rinsho Ketsueki. 2015;56(7):752–9.PubMed Yamashiro Y, Hattori Y. Hemoglobinopathies in Japan: characteristics and comparison with those of other ethnic groups. Rinsho Ketsueki. 2015;56(7):752–9.PubMed
Metadaten
Titel
A diabetic patient in whom Hb Weesp was incidentally detected when her HbA1c level was measured
verfasst von
Tomomi Hatayama
Fumio Umeda
Teruaki Yamauchi
Hiroshi Ideguchi
Publikationsdatum
05.07.2019
Verlag
Springer Japan
Erschienen in
Diabetology International / Ausgabe 4/2019
Print ISSN: 2190-1678
Elektronische ISSN: 2190-1686
DOI
https://doi.org/10.1007/s13340-019-00402-z

Weitere Artikel der Ausgabe 4/2019

Diabetology International 4/2019 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.