Skip to main content
Erschienen in: Surgical Endoscopy 4/2008

01.04.2008

A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine model

verfasst von: C. Schug-Paß, C. Tamme, F. Sommerer, A. Tannapfel, H. Lippert, F. Köckerling

Erschienen in: Surgical Endoscopy | Ausgabe 4/2008

Einloggen, um Zugang zu erhalten

Abstract

Background

A meticulous surgical technique, a mesh of adequate dimensions, and use of a mesh with good biocompatibility properties are decisively important for minimizing the development of recurrences after endoscopic hernia repair surgery. Mesh “shrinkage” is a function of the mesh’s biocompatibility, that is, the properties of the mesh. Large-pore, lightweight polypropylene meshes possess the best biocompatibility, and the newly developed meshes meet these requirements.

Methods

Using a totally extraperitoneal technique in an experimental animal model, 10 domestic pigs were implanted with a lightweight, large-pore polypropylene mesh containing an absorbable component consisting of poliglecaprone (Ultrapro). After a period of 91 days, diagnostic laparoscopy followed by explantation of the specimens for macroscopic, histologic, and immunohistochemical evaluation was performed.

Results

The mean mesh shrinkage was a mere 1.9%. The partial volume of the inflammatory cells was a low 15.8%. The markers of cell turnover, namely Ki67 and the apoptosis index, were, at 5.8 and 2.1, respectively, also very low. The extracellular matrix showed a low value of transforming growth factor-beta (TGF-beta) (50.8). The mean value of collagen 1 was 136.9.

Conclusions

As a result of its good biocompatibility and elastic properties, the lightweight, large-pore Ultrapo mesh showed only a very slight tendency to “shrink.” This renders it extremely well suited for clinical use in hernia repair surgery, and its minimal shrinkage characteristic should help in achieving low complication and recurrence rates.
Literatur
1.
Zurück zum Zitat Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef
2.
Zurück zum Zitat Greca FH, de Paula JB, Biondo-Simmoes ML, da Costa FD, da Silva AP, Times S, Mansur A (2001) The influence of differing pore sizes on biocompatibility of two polypropylene meshes in the repair of abdominal defects: experimental study in dogs. Hernia 5:59–64PubMedCrossRef Greca FH, de Paula JB, Biondo-Simmoes ML, da Costa FD, da Silva AP, Times S, Mansur A (2001) The influence of differing pore sizes on biocompatibility of two polypropylene meshes in the repair of abdominal defects: experimental study in dogs. Hernia 5:59–64PubMedCrossRef
3.
Zurück zum Zitat Junge K, Rosch R, Bialasinski L, Klinge U, Klosterhalfen B, Schumpelick V (2003) Persistent extracellular matrix remodelling at the interface to polymers used for hernia repair. Eur Surg Res 35:497–504PubMedCrossRef Junge K, Rosch R, Bialasinski L, Klinge U, Klosterhalfen B, Schumpelick V (2003) Persistent extracellular matrix remodelling at the interface to polymers used for hernia repair. Eur Surg Res 35:497–504PubMedCrossRef
4.
Zurück zum Zitat Junge K, Rosch R, Krones CJ, Klinge U, Mertens PR, Lynen P, Schumpelick V, Klosterhalfen B (2005) Influence of polyglecaprone 25 (Monocryl) supplementation on biocompatibility of a polypropylene mesh for hernia repair. Hernia 9:212–217 PubMedCrossRef Junge K, Rosch R, Krones CJ, Klinge U, Mertens PR, Lynen P, Schumpelick V, Klosterhalfen B (2005) Influence of polyglecaprone 25 (Monocryl) supplementation on biocompatibility of a polypropylene mesh for hernia repair. Hernia 9:212–217 PubMedCrossRef
5.
Zurück zum Zitat Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef
6.
Zurück zum Zitat Klinge U, Klosterhalfen B, Müller M, Öttinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969PubMedCrossRef Klinge U, Klosterhalfen B, Müller M, Öttinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969PubMedCrossRef
7.
Zurück zum Zitat Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246PubMedCrossRef Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246PubMedCrossRef
8.
Zurück zum Zitat Knook MTT, van Rosmalen AC, Yoder BE, Kleinrensink GJ, Snijders CJ, Looman CWN, van Steensel CJ (2001) Optimal mesh size for endoscopic inguinal hernia repair: a study in a porcine model. Surg Endosc 15:1471–1477PubMedCrossRef Knook MTT, van Rosmalen AC, Yoder BE, Kleinrensink GJ, Snijders CJ, Looman CWN, van Steensel CJ (2001) Optimal mesh size for endoscopic inguinal hernia repair: a study in a porcine model. Surg Endosc 15:1471–1477PubMedCrossRef
9.
Zurück zum Zitat Molea G, Schonauer F, Bifulco G, D’Angelo D (2000) Comparative study on biocompatibility and absorption times of three absorbable monofilament suture materials (polydioxanone, poliglecaprone 25, glycomer 631) Br J Plast Surg 53:137–141PubMedCrossRef Molea G, Schonauer F, Bifulco G, D’Angelo D (2000) Comparative study on biocompatibility and absorption times of three absorbable monofilament suture materials (polydioxanone, poliglecaprone 25, glycomer 631) Br J Plast Surg 53:137–141PubMedCrossRef
10.
Zurück zum Zitat Nary Filho H, Matsumoto MA, Batista AC, Lopes LC, de Goes FC, Consolaro A (2002) Comparative study of tissue response to polyglecaprone 25, polyglactin 910, and polytetrafluorethylene suture materials in rats. Braz Dent J 13:86–91PubMedCrossRef Nary Filho H, Matsumoto MA, Batista AC, Lopes LC, de Goes FC, Consolaro A (2002) Comparative study of tissue response to polyglecaprone 25, polyglactin 910, and polytetrafluorethylene suture materials in rats. Braz Dent J 13:86–91PubMedCrossRef
11.
Zurück zum Zitat Neumayer L (2004) Open mesh versus laparoscopic mesh hernia repair. N Engl J Med 350:1463–1465 (author’s reply). See comment in N Engl J Med 350:1819–1827 Neumayer L (2004) Open mesh versus laparoscopic mesh hernia repair. N Engl J Med 350:1463–1465 (author’s reply). See comment in N Engl J Med 350:1819–1827
12.
Zurück zum Zitat Neumayer L, Giobbie-Hurder A, Jonasson O, Fitzgibbons R Jr, Dunlop D, Gibbs J, Reda D, Henderson W, Veterans Affairs Cooperative Studies Program 456 Investigators (2004) Open mesh versus laparoscopic mesh repair of inguinal hernia. N Engl J Med 350:1819–1827PubMedCrossRef Neumayer L, Giobbie-Hurder A, Jonasson O, Fitzgibbons R Jr, Dunlop D, Gibbs J, Reda D, Henderson W, Veterans Affairs Cooperative Studies Program 456 Investigators (2004) Open mesh versus laparoscopic mesh repair of inguinal hernia. N Engl J Med 350:1819–1827PubMedCrossRef
13.
Zurück zum Zitat O’Dwyer PJ, Kingsnorth AN, Molloy RG, Small PK, Lammers B, Horeyseck G (2005) Randomized clinical trial assessing impact of lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92:166–170PubMedCrossRef O’Dwyer PJ, Kingsnorth AN, Molloy RG, Small PK, Lammers B, Horeyseck G (2005) Randomized clinical trial assessing impact of lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92:166–170PubMedCrossRef
14.
Zurück zum Zitat Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty. Surg Endosc 18:211–220PubMedCrossRef Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty. Surg Endosc 18:211–220PubMedCrossRef
15.
Zurück zum Zitat Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Köckerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. Eur Surg Res 36:313–317PubMedCrossRef Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Köckerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. Eur Surg Res 36:313–317PubMedCrossRef
16.
Zurück zum Zitat Schmedt CG, Daubler P, Leibl BJ, Kraft K, Bittner R (2002) Simultaneous bilateral laparoscopic inguinal hernia repair: an analysis of 1,336 consecutive cases at a single center. Surg Endosc 16:240–244PubMedCrossRef Schmedt CG, Daubler P, Leibl BJ, Kraft K, Bittner R (2002) Simultaneous bilateral laparoscopic inguinal hernia repair: an analysis of 1,336 consecutive cases at a single center. Surg Endosc 16:240–244PubMedCrossRef
17.
Zurück zum Zitat Schumpelick V, Klinge U, Welty G, Klosterhalfen B (2000) Meshes within the abdominal wall. Chirurg 70:876–887 Schumpelick V, Klinge U, Welty G, Klosterhalfen B (2000) Meshes within the abdominal wall. Chirurg 70:876–887
18.
Zurück zum Zitat Tamme C, Garde N, Klingler A, Hampe C, Wunder R, Köckerling F (2005) Totally extraperitoneal inguinal hernioplasty with titanium-coated lightweight polypropylene mesh: early results. Surg Endosc 19:1125–1129PubMedCrossRef Tamme C, Garde N, Klingler A, Hampe C, Wunder R, Köckerling F (2005) Totally extraperitoneal inguinal hernioplasty with titanium-coated lightweight polypropylene mesh: early results. Surg Endosc 19:1125–1129PubMedCrossRef
19.
Zurück zum Zitat Tamme C, Scheidbach H, Hampe C, Schneider C, Köckerling F (2003) Totally extraperitoneal endoscopic inguinal hernia repair (TEP). Surg Endosc 17:190–195PubMedCrossRef Tamme C, Scheidbach H, Hampe C, Schneider C, Köckerling F (2003) Totally extraperitoneal endoscopic inguinal hernia repair (TEP). Surg Endosc 17:190–195PubMedCrossRef
20.
Zurück zum Zitat Welty G, Klinge U, Klosterhalfen B, Kasperk R, Schumpelick V (2001) Functional impairment and complaints following incisional hernia repair with different polypropylene meshes. Hernia 5:142–147PubMedCrossRef Welty G, Klinge U, Klosterhalfen B, Kasperk R, Schumpelick V (2001) Functional impairment and complaints following incisional hernia repair with different polypropylene meshes. Hernia 5:142–147PubMedCrossRef
Metadaten
Titel
A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine model
verfasst von
C. Schug-Paß
C. Tamme
F. Sommerer
A. Tannapfel
H. Lippert
F. Köckerling
Publikationsdatum
01.04.2008
Verlag
Springer-Verlag
Erschienen in
Surgical Endoscopy / Ausgabe 4/2008
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-007-9585-1

Weitere Artikel der Ausgabe 4/2008

Surgical Endoscopy 4/2008 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.