Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2014

01.03.2014 | Knee

A new spacer-guided, PCL balancing technique for cruciate-retaining total knee replacement

verfasst von: P. J. C. Heesterbeek, L. Labey, P. Wong, B. Innocenti, A. B. Wymenga

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 3/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The goal of this study was to investigate whether a new posterior cruciate ligament (PCL) balancing approach with a spacer technique during total knee arthroplasty (TKA) reproduced the correct tibiofemoral contact point (CP) location. It was hypothesized that it should be possible to adequately balance the PCL with this geometrical technique, obtaining correct position and stability of the medial femoral condyle, independent of insert shape.

Methods

Nine fresh-frozen full-leg cadaver specimens were used. After native testing, prototype components of a new PCL-retaining implant were implanted using navigation and a bone-referencing technique. After finishing the bone cuts, the spacer technique was used to ascertain balancing of the PCL and the tibial cut was corrected if necessary. Passive and squat motions were performed before and after TKA using a dynamic knee simulator while tibiofemoral kinematics were recorded using six infrared cameras. CPs (native and implant) were calculated as the projections of the femoral condylar centres on the horizontal plane of the tibia.

Results

The spacer technique resulted in correct PCL balancing in all specimens. The kinematic patterns of native and replaced knees showed no statistically significant differences in passive and squat motions. The medial CP after TKA was at the same position as in the native knee. No paradoxical sliding forward was seen after TKA, supporting our hypothesis.

Conclusions

The spacer technique can be applied by surgeons during PCL-retaining TKA and will lead to good PCL balancing, indicated by a correct CP, no lift-off in flexion and no posterior sag.
Literatur
1.
Zurück zum Zitat Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA (2003) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138PubMedCrossRef Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA (2003) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138PubMedCrossRef
2.
Zurück zum Zitat Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84:50–53PubMedCrossRef Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84:50–53PubMedCrossRef
3.
Zurück zum Zitat Catani F, Innocenti B, Belvedere C, Labey L, Ensini A, Leardini A (2010) The mark coventry award: articular contact estimation in TKA using in vivo kinematics and finite element analysis. Clin Orthop Relat Res 468:19–28PubMedCrossRef Catani F, Innocenti B, Belvedere C, Labey L, Ensini A, Leardini A (2010) The mark coventry award: articular contact estimation in TKA using in vivo kinematics and finite element analysis. Clin Orthop Relat Res 468:19–28PubMedCrossRef
4.
Zurück zum Zitat de Jong RJ, Heesterbeek PJ, Wymenga AB (2010) A new measurement technique for the tibiofemoral contact point in normal knees and knees with TKR. Knee Surg Sports Traumatol Arthrosc 18:388–393PubMedCrossRef de Jong RJ, Heesterbeek PJ, Wymenga AB (2010) A new measurement technique for the tibiofemoral contact point in normal knees and knees with TKR. Knee Surg Sports Traumatol Arthrosc 18:388–393PubMedCrossRef
5.
Zurück zum Zitat Freeman MA, Pinskerova V (2003) The movement of the knee studied by magnetic resonance imaging. Clin Orthop Relat Res 410:35–43PubMedCrossRef Freeman MA, Pinskerova V (2003) The movement of the knee studied by magnetic resonance imaging. Clin Orthop Relat Res 410:35–43PubMedCrossRef
6.
Zurück zum Zitat Gollehon DL, Torzilli PA, Warren RF (1987) The role of the posterolateral and cruciate ligaments in the stability of the human knee. A biomechanical study. J Bone Joint Surg Am 69:233–242PubMed Gollehon DL, Torzilli PA, Warren RF (1987) The role of the posterolateral and cruciate ligaments in the stability of the human knee. A biomechanical study. J Bone Joint Surg Am 69:233–242PubMed
7.
Zurück zum Zitat Heesterbeek P, Keijsers N, Jacobs W, Verdonschot N, Wymenga A (2010) Posterior cruciate ligament recruitment affects antero-posterior translation during flexion gap distraction in total knee replacement. An intraoperative study involving 50 patients. Acta Orthop 81:471–477PubMedCrossRef Heesterbeek P, Keijsers N, Jacobs W, Verdonschot N, Wymenga A (2010) Posterior cruciate ligament recruitment affects antero-posterior translation during flexion gap distraction in total knee replacement. An intraoperative study involving 50 patients. Acta Orthop 81:471–477PubMedCrossRef
8.
Zurück zum Zitat Kim H, Pelker RR, Gibson DH, Irving JF, Lynch JK (1997) Rollback in posterior cruciate ligament-retaining total knee arthroplasty. A radiographic analysis. J Arthroplast 12:553–561CrossRef Kim H, Pelker RR, Gibson DH, Irving JF, Lynch JK (1997) Rollback in posterior cruciate ligament-retaining total knee arthroplasty. A radiographic analysis. J Arthroplast 12:553–561CrossRef
9.
Zurück zum Zitat Kurtz SM, Villarraga ML, Herr MP, Bergstrom JS, Rimnac CM, Edidin AA (2002) Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements. Biomaterials 23:3681–3697PubMedCrossRef Kurtz SM, Villarraga ML, Herr MP, Bergstrom JS, Rimnac CM, Edidin AA (2002) Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements. Biomaterials 23:3681–3697PubMedCrossRef
10.
Zurück zum Zitat Liabaud B, Patrick DA Jr, Geller JA (2013) Is the posterior cruciate ligament destabilized after the tibial cut in a cruciate retaining total knee replacement? An anatomical study. Knee. doi:S0968-0160(13)00022-7 Liabaud B, Patrick DA Jr, Geller JA (2013) Is the posterior cruciate ligament destabilized after the tibial cut in a cruciate retaining total knee replacement? An anatomical study. Knee. doi:S0968-0160(13)00022-7
11.
Zurück zum Zitat Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2012) Intraoperative soft tissue balance reflects minimum 5-year midterm outcomes in cruciate-retaining and posterior-stabilized total knee arthroplasty. J Arthroplast 27:1723–1730CrossRef Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2012) Intraoperative soft tissue balance reflects minimum 5-year midterm outcomes in cruciate-retaining and posterior-stabilized total knee arthroplasty. J Arthroplast 27:1723–1730CrossRef
12.
Zurück zum Zitat Mihalko WM, Krackow KA (1999) Posterior cruciate ligament effects on the flexion space in total knee arthroplasty. Clin Orthop Relat Res 360:243–250PubMedCrossRef Mihalko WM, Krackow KA (1999) Posterior cruciate ligament effects on the flexion space in total knee arthroplasty. Clin Orthop Relat Res 360:243–250PubMedCrossRef
13.
Zurück zum Zitat Most E, Li G, Sultan PG, Park SE, Rubash HE (2005) Kinematic analysis of conventional and high-flexion cruciate-retaining total knee arthroplasties an in vitro investigation. J Arthroplast 20:529–535CrossRef Most E, Li G, Sultan PG, Park SE, Rubash HE (2005) Kinematic analysis of conventional and high-flexion cruciate-retaining total knee arthroplasties an in vitro investigation. J Arthroplast 20:529–535CrossRef
14.
Zurück zum Zitat Nakagawa S, Johal P, Pinskerova V, Komatsu T, Sosna A, Williams A, Freeman MA (2004) The posterior cruciate ligament during flexion of the normal knee. J Bone Joint Surg Br 86:450–456PubMedCrossRef Nakagawa S, Johal P, Pinskerova V, Komatsu T, Sosna A, Williams A, Freeman MA (2004) The posterior cruciate ligament during flexion of the normal knee. J Bone Joint Surg Br 86:450–456PubMedCrossRef
15.
Zurück zum Zitat Pagnano MW, Hanssen AD, Lewallen DG, Stuart MJ (1998) Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clin Orthop Relat Res 356:39–46PubMedCrossRef Pagnano MW, Hanssen AD, Lewallen DG, Stuart MJ (1998) Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clin Orthop Relat Res 356:39–46PubMedCrossRef
16.
Zurück zum Zitat Pianigiani S, Chevalier Y, Labey L, Pascale V, Innocenti B (2012) Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study. J Biomech 45:2315–2323PubMedCrossRef Pianigiani S, Chevalier Y, Labey L, Pascale V, Innocenti B (2012) Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study. J Biomech 45:2315–2323PubMedCrossRef
17.
Zurück zum Zitat Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA (2004) Does the femur roll-back with flexion? J Bone Joint Surg Br 86:925–931PubMedCrossRef Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA (2004) Does the femur roll-back with flexion? J Bone Joint Surg Br 86:925–931PubMedCrossRef
18.
Zurück zum Zitat Pruitt LA (2005) Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene. Biomaterials 26:905–915PubMedCrossRef Pruitt LA (2005) Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene. Biomaterials 26:905–915PubMedCrossRef
19.
Zurück zum Zitat Romero J, Stahelin T, Binkert C, Pfirrmann C, Hodler J, Kessler O (2007) The clinical consequences of flexion gap asymmetry in total knee arthroplasty. J Arthroplast 22:235–240CrossRef Romero J, Stahelin T, Binkert C, Pfirrmann C, Hodler J, Kessler O (2007) The clinical consequences of flexion gap asymmetry in total knee arthroplasty. J Arthroplast 22:235–240CrossRef
20.
Zurück zum Zitat Schuster AJ, von Roll AL, Pfluger D, Wyss T (2011) Anteroposterior stability after posterior cruciate-retaining total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1113–1120PubMedCrossRef Schuster AJ, von Roll AL, Pfluger D, Wyss T (2011) Anteroposterior stability after posterior cruciate-retaining total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1113–1120PubMedCrossRef
21.
Zurück zum Zitat Swany MR, Scott RD (1993) Posterior polyethylene wear in posterior cruciate ligament-retaining total knee arthroplasty. A case study. J Arthroplast 8:439–446CrossRef Swany MR, Scott RD (1993) Posterior polyethylene wear in posterior cruciate ligament-retaining total knee arthroplasty. A case study. J Arthroplast 8:439–446CrossRef
22.
Zurück zum Zitat Victor J, Van GF, Vander SJ, Parizel PM, Somville J, Bellemans J (2009) An experimental model for kinematic analysis of the knee. J Bone Joint Surg Am 91(Suppl 6):150–163PubMedCrossRef Victor J, Van GF, Vander SJ, Parizel PM, Somville J, Bellemans J (2009) An experimental model for kinematic analysis of the knee. J Bone Joint Surg Am 91(Suppl 6):150–163PubMedCrossRef
23.
Zurück zum Zitat Wilson DR, Apreleva MV, Eichler MJ, Harrold FR (2003) Accuracy and repeatability of a pressure measurement system in the patellofemoral joint. J Biomech 36:1909–1915PubMedCrossRef Wilson DR, Apreleva MV, Eichler MJ, Harrold FR (2003) Accuracy and repeatability of a pressure measurement system in the patellofemoral joint. J Biomech 36:1909–1915PubMedCrossRef
24.
Zurück zum Zitat Yoshiya S, Matsui N, Komistek RD, Dennis DA, Mahfouz M, Kurosaka M (2005) In vivo kinematic comparison of posterior cruciate-retaining and posterior stabilized total knee arthroplasties under passive and weight-bearing conditions. J Arthroplast 20:777–783CrossRef Yoshiya S, Matsui N, Komistek RD, Dennis DA, Mahfouz M, Kurosaka M (2005) In vivo kinematic comparison of posterior cruciate-retaining and posterior stabilized total knee arthroplasties under passive and weight-bearing conditions. J Arthroplast 20:777–783CrossRef
Metadaten
Titel
A new spacer-guided, PCL balancing technique for cruciate-retaining total knee replacement
verfasst von
P. J. C. Heesterbeek
L. Labey
P. Wong
B. Innocenti
A. B. Wymenga
Publikationsdatum
01.03.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2014
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2660-3

Weitere Artikel der Ausgabe 3/2014

Knee Surgery, Sports Traumatology, Arthroscopy 3/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.