Abstract

Background

Colorectal stents have a proven role in colorectal cancer as palliative care or a bridge to surgery. However, their efficacy and anchoring to the tissue varies according to stent design with stent migration rates up to 50 %. We present preliminary in vivo results of a new end-luminal anchoring system for stent fixation to the rectal canal. The aim was to assess the efficacy and safety of the stent using the anchoring system while subjecting the device to daily abdominal pressures related to daily activities in a porcine animal model.

Methods

Ex vivo anatomical and physical studies were performed to improve the system’s structure and safety. Four female pigs were followed for the acute and chronic (16 weeks) period. Two animals were euthanized and underwent en-bloc pelvic visceral excision and histopathological examination. Device fixation time, animal behavior, device patency, anoscopic examination and histopathological features were assessed.

Results

Mean anchoring time was 13.83 weeks (standard error ± 1.38 weeks). One of the animals experienced early device expulsion with no complications. No obstruction was noted in any of the animals. Macroscopic examination revealed mild focal submucosal scarring in one animal and a normal examination in the other. Hematoxylin and eosin staining revealed mucosal ulceration and mixed inflammatory cell infiltrate, with no signs of granulomata, foreign body giant cell reaction or microabscess formation.

Conclusions

A novel fixation device designed for long-term intrarectal implantation was well tolerated and maintained anal canal patency without migration. Larger studies are needed before its implementation in humans.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 6/2014

Techniques in Coloproctology 6/2014 Zur Ausgabe
  1. Sie können e.Med Chirurgie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet Chirurgie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Chirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise