Background

Routine implant removal after fracture healing remains controversial. However, it has been suggested that implant removal should be performed in cases of joint impingement, painful scar adhesion, and implant malposition. Entrance selection is relatively critical in patients with poor soft tissue conditions or sloughing coverage. We propose an innovative technique using endoscopy.

Methods

Consecutive surgeries of endoscopic implant removal performed between 2005 and 2016 by a single experienced arthroscopic surgeon were included. Overall, 73 patients were enrolled; 44 were not eligible for inclusion and were excluded from the study.

Results

Twenty-nine patients, including 32 surgical sites, were included. Twenty-four plates and 166 screws were removed using this technique. There were five complications during the follow-up period (range, 0.5 to 104 months; mean, 8.8), including one broken screw, one persistent knee joint contracture, and three wound dehiscence. There were no infections or neurovascular injuries.

Conclusion

Implant removal using endoscopy is a minimally invasive surgery that ensures that the screw axis does not strip, and treats the intra-articular pathology concomitantly. This innovative technique may be considered as an alternative to the traditional open method in cases with good surgical indications.

Background

The evolution of the treatment of patients with fractures is multifactorial. With the progression of biomaterials, biomechanics, fabrication, electronics, surgical facilities, and physician training, the use of fixators to treat patients with fractures has also dramatically progressed. Application of implants to the human body can be challenging in placement and removal. However, the concept of internal fixation dates back to the mid-1800s and remains the mainstay of fracture management. Internal fixators available in modern hospitals include the intramedullary nails, wires, pins, plates, and hybrid systems. The injury pattern, fracture location, and surgeon preference all dictate implant selection. Routine implant removal after fracture healing remains controversial [14]. Neurovascular injury, re-fracture, recurrent deformity, and wound infection are the possible complications of implant removal [57]. However, it has been suggested that implants should be removed in cases of painful scar adhesion, joint impingement with limited range-of-motion, prominent implants with skin tenting, and implant malposition. Because of patient differences, cultural factors also are important considerations in daily practice.
Surgeons generally use previous incisions when retrieving internal fixators, because a uniform entrance yields the same surgical field and better cosmetic outcome by avoiding a second scar. However, it is not always feasible to use the same entrance. Using the same entrance may be disastrous and result in serious complications in complicated soft-tissue problems and sloughing coverage [811]. Furthermore, minimally invasive procedures may be required in certain cases, and arthroscopy or endoscopy usually may be used. However, studies evaluating implant retrieval using endoscopy are limited [1215]. The goal of this study is to propose a novel implant-retrieval technique using endoscopy under various conditions. We suggest that this innovative technique is useful and easy for most surgeons, with excellent patient satisfaction and significant clinical benefit.

Material and methods

Consecutive cases that presented to our hospital (Chang Gung Memorial Hospital, Linkou) between 2005 and 2016 were enrolled in this study. Medical records were reviewed for surgical procedures, types of internal fixators, numbers of wounds needed for removal, wound healing condition, and complications. Patients who underwent knee ligament reconstruction or removal of prominent graft fixators were excluded. All surgeries were performed by a single experienced arthroscopic surgeon. A total of 73 cases were identified and 44 were excluded because they did not meet the criteria for inclusion. This retrospective review of medical records and radiographs was approved by the hospital’s institutional review board.

Operative technique

Patients were positioned in either the supine or decubitus position for adequate surgical exposure while under general anesthesia. The plate contour and screw positions were palpated and marked on the skin with a marking pen. Portals were then designed according to different surgical sites and shapes of the internal fixators, which were facilitated for screw removal. One portal could generally be used to remove one to three screws; 0.5 cm for each portal was sufficient. First, a working space between the plate and scar tissue was made via blunt dissection followed by careful thermal shrinkage. The screw heads were visualized clearly under endoscopy, ensuring a match between the screwdriver and screw head. The screws were then removed sequentially under direct visualization. Gentle skin traction was needed to allow for the passage of the screw heads over the skin; skin extension was not necessary. Working and endoscopy portals were used alternately until all screws were removed. A number 18 needle was used to identify the screw head and the axis in difficult cases where the screws were in several different directions, including inter-fragmental or lag screws, and cases where screws could not be removed via the original portals, and the screw was removed via a new small stab wound. After removing all the screws, the plate was freely mobile under the subcutaneous space, and could be removed. Finally, the wounds were irrigated with normal saline, and closed with non-absorbable nylon sutures.

Results

Twenty-nine patients (32 surgical sites) underwent endoscopic implant removal during the study period, including 15 men and 14 women with a mean age of 39 years (range, 20–72 years) at the time of the surgery. Surgical sites included 13 tibial plateaus, 7 lateral malleoli, 4 distal femurs, 3 clavicles, 2 tibial shafts, 2 distal tibias, and 1 medial malleolus. Twenty-six patients had fracture union, and mean time from index osteosynthesis to implant removal was 25.3 months (range 5–124 months). The other three patients were treated for chronic osteomyelitis-infected unions; they all had poor skin conditions due to the infection and repeated surgeries.
A total of 24 plates and 166 screws were removed using this technique, including 6 traditional L- or T-shaped buttress plates, 6 semi-tubular plates, 5 locking plates, 4 dynamic compression plates, 1 reconstruction plate, 1 dynamic condylar screw, and one 95° L-plate (Figs. 1, 2, 3, 4, and 5). Mean surgical time, from skin incision to closure, was 49.8 min (range 20–133 min). Blood loss was minimal in all surgeries because most were performed using a tourniquet. The mean number of wounds for each case was 2.7 (range, 2 to 8). The average follow-up time was 8.8 months (range 0.5–104 months).
There were five complications, including one broken screw, three wound dehiscence, and one knee joint contracture. The broken screw was in the clavicle due to implant failure, and surgery was shifted to a mini-open method to remove the screw successfully. One wound dehiscence was in the lateral malleolus due to poor wound healing, which was resolved by repeated skin suture. The other two cases of wound dehiscence were chronic osteomyelitis of the tibial shaft, both of which received parenteral antibiotic therapy and wound care in the hospital for 7 and 12 days, respectively, and then were treated as outpatients. The last case was a fracture of the distal femur with knee contracture even after implant removal and arthroscopic release. This patient underwent another arthroscopic contracture release surgery 3 months later followed by regular physical therapy at a clinic.

Discussion

Routine implant removal is usually not necessary after fracture healing [14, 16]. Symptomatic foreign body sensation with impaired limb function is the major indication for implant removal, followed by scar-related adhesion, local prominence, skin erosion, and mechanical. The traditional open approach is safe and familiar for most surgeons. However, additional removal surgery means further soft-tissue damage, which is associated with an increased risk for delayed wound healing and poor soft-tissue coverage of the bone, especially when entering from the previous incisions. With the advancement of arthroscopic techniques, the indication for minimally invasive surgery can be shifted from the intra-articular region to extra-articular sites (i.e., endoscopy). Endoscopic surgery provides all of the benefits of minimally invasive surgery and can be applied to implant removal with less soft-tissue damage and faster recovery [13]. Small stab wounds even meet the cosmetic concern. In our series, 29 patients (including 32 surgical sites) received the elective implant removal surgery, and only 1 case was complicated with surgery-related wound problem (the other 2 cases were related to chronic osteomyelitis). The wound complication rate was 3%, which was comparable to the surgical site infection rate of clean surgery (2%) [17] and much less than orthopedic implant removal surgery ever reported (12.2 to 20%) [9, 11, 18].
The application of endoscopy in implant removal is currently limited. Most cases involve the proximal humerus or shoulder joint region. Removing the proximal humerus plate and screws while concomitantly treating the glenohumeral joint or subacromial pathology via arthroscopy has been previously reported [12, 14, 19, 20]. Intra-articular adhesion arthrolysis, capsular release, and debridement of the subacromial impingement as well as early osteoarthritis and osteochondral lesion treatment can be performed simultaneously using this minimally invasive technique. It has also been shown to have promising results comparable to open procedures [13, 21]. However, implant retrieval from the proximal humerus is associated with an increased risk of axillary nerve injury [15]. Performing scar release with a shaver or electronic dissector before screw and plate removal especially places the axillary nerve at high risk for damage. Although the anatomical position of the motor branch of the axillary nerve is well understood [22], intraoperative fluoroscopy still may be required as a guide [15, 23]. A radiofrequency device with feedback function, rather than a shaver, for dissection also has been suggested.
Applying endoscopy in implant retrieval has several advantages, including minimal soft-tissue trauma and blood loss, as only a few small stab wounds are required [14, 23]. In addition, continuous saline irrigation during surgery lowers the risk of infection at the surgical site [15], while screw direction can be visualized under endoscopy, offering less chance of screw stripping, especially with locking screws. Finally, endoscopy can be shifted to the intra-articular region for arthroscopic examination, if indicated, after completing removal.
In our series, there were three cases of wound dehiscence, one in the lateral malleolus and two in the tibial shaft. The tibial shaft cases were both chronic osteomyelitis with initially poor skin condition. Therefore, there were still wound healing problems even with this minimally invasive technique. The other two complications—implant failure and persistent joint contracture—were not directly related to the surgical procedure. Regardless, the overall complication rate was quite low and acceptable, demonstrating that using endoscopy in implant removal is innovative and safe.
However, surgeons attempting this new technique must be very familiar with scope handling. Unlike routine joint arthroscopy, landmarks are usually deficient. Surgical planes should be created using blunt dissection by the surgeons themselves, and portal placement should be designed before skin incision based on the surgical site and implant type. In addition, the surgical orientation under endoscopy must be practiced several times with routine arthroscopy. Thus, we recommend mastering routine arthroscopy before attempting implant retrieval with endoscopy.
To our knowledge, this is the first article describing the application of endoscopy in implant removal. The indications for this minimally invasive technique include (1) retrieving implants from a relatively thin region, such as the clavicle, tibial plateau, tibial shaft, or lateral malleolus; (2) retrieving implants from a region with poor soft-tissue condition, such as an open fracture wound after skin grafting; (3) simultaneously retrieving implants and performing arthroscopic surgery, such as ankle joint examination after the removal of lateral malleolar implants; and (4) anticipated difficult wound closure by the traditional open method, such as hard scar tissue on the tibial plateau.
Using endoscopy to retrieve implants has never been published, and this is the strength of our study. Small patient numbers as well as lacking of control groups are the limitations. More cases with longer follow-ups are needed, and application of this technique in other surgical sites, such as the distal radius, femoral shaft, and pelvic region, could be studied in the future. With good patient outcomes, this new technique could be an alternative to the traditional open method.

Conclusion

Implant retrieval using endoscopy is an innovative technique with all the advantages of minimally invasive surgery, including less soft-tissue damage, minimal blood loss, and rapid recovery. It is safe with a low complication rate, but surgeons should master arthroscopy before attempting this endoscopic technique. This technique may be an alternative to the traditional open method under good surgical indications.

Acknowledgements

Not applicable

Funding

No funding for this article should be declared.

Availability of data and materials

All data generated or analyzed during this study are included in this published article.
Chang Gung Medical Foundation Institutional Review Board.
IRB No. 201601489B0.
No consent was needed from any patients involved in this retrospectively reviewed case series study.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Kirchhoff C, Braunstein V, Kirchhoff S, Sprecher CM, Ockert B, Fischer F, et al. Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord. 2008;9:138.CrossRefPubMedPubMedCentral Kirchhoff C, Braunstein V, Kirchhoff S, Sprecher CM, Ockert B, Fischer F, et al. Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord. 2008;9:138.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Lutsky KF, Beredjiklian PK, Hioe S, Bilello J, Kim N, Matzon JL. Incidence of hardware removal following volar plate fixation of distal radius fracture. J Hand Surg. 2015;40(12):2410–5.CrossRef Lutsky KF, Beredjiklian PK, Hioe S, Bilello J, Kim N, Matzon JL. Incidence of hardware removal following volar plate fixation of distal radius fracture. J Hand Surg. 2015;40(12):2410–5.CrossRef
4.
Zurück zum Zitat Tan A, Chong A. Reasons for implant removal after distal radius fractures. J Hand Surg Asian Pac Vol. 2016;21(3):321–5.CrossRefPubMed Tan A, Chong A. Reasons for implant removal after distal radius fractures. J Hand Surg Asian Pac Vol. 2016;21(3):321–5.CrossRefPubMed
5.
Zurück zum Zitat Lovald S, Mercer D, Hanson J, Cowgill I, Erdman M, Robinson P, et al. Complications and hardware removal after open reduction and internal fixation of humeral fractures. J Trauma. 2011;70(5):1273–7. discussion 7-8CrossRefPubMed Lovald S, Mercer D, Hanson J, Cowgill I, Erdman M, Robinson P, et al. Complications and hardware removal after open reduction and internal fixation of humeral fractures. J Trauma. 2011;70(5):1273–7. discussion 7-8CrossRefPubMed
6.
Zurück zum Zitat Busam ML, Esther RJ, Obremskey WT. Hardware removal: indications and expectations. J Am Acad Orthop Surg. 2006;14(2):113–20.CrossRefPubMed Busam ML, Esther RJ, Obremskey WT. Hardware removal: indications and expectations. J Am Acad Orthop Surg. 2006;14(2):113–20.CrossRefPubMed
7.
Zurück zum Zitat Ochs BG, Gonser CE, Baron HC, Stockle U, Badke A, Stuby FM. Refracture of long bones after implant removal. An avoidable complication? Unfallchirurg. 2012;115(4):323–9.CrossRefPubMed Ochs BG, Gonser CE, Baron HC, Stockle U, Badke A, Stuby FM. Refracture of long bones after implant removal. An avoidable complication? Unfallchirurg. 2012;115(4):323–9.CrossRefPubMed
8.
Zurück zum Zitat Sanderson PL, Ryan W, Turner PG. Complications of metalwork removal. Injury. 1992;23(1):29–30.CrossRefPubMed Sanderson PL, Ryan W, Turner PG. Complications of metalwork removal. Injury. 1992;23(1):29–30.CrossRefPubMed
9.
Zurück zum Zitat Backes M, Schep NW, Luitse JS, Goslings JC, Schepers T. High rates of postoperative wound infection following elective implant removal. Open Orthop J. 2015;9:418–21.CrossRefPubMedPubMedCentral Backes M, Schep NW, Luitse JS, Goslings JC, Schepers T. High rates of postoperative wound infection following elective implant removal. Open Orthop J. 2015;9:418–21.CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Reith G, Schmitz-Greven V, Hensel KO, Schneider MM, Tinschmann T, Bouillon B, et al. Metal implant removal: benefits and drawbacks—a patient survey. BMC Surg. 2015;15:96.CrossRefPubMedPubMedCentral Reith G, Schmitz-Greven V, Hensel KO, Schneider MM, Tinschmann T, Bouillon B, et al. Metal implant removal: benefits and drawbacks—a patient survey. BMC Surg. 2015;15:96.CrossRefPubMedPubMedCentral
11.
12.
Zurück zum Zitat Lill H, Katthagen C, Voigt C. Technique and value of arthroscopic implant removal in the shoulder. Orthopade. 2011;40(1):79–84.CrossRefPubMed Lill H, Katthagen C, Voigt C. Technique and value of arthroscopic implant removal in the shoulder. Orthopade. 2011;40(1):79–84.CrossRefPubMed
13.
Zurück zum Zitat Katthagen JC, Jensen G, Hennecke D, Lill H, Voigt C. Arthroscopic implant removal after fixed-angle plate osteosynthesis of the proximal humerus. Technique and initial results in comparison to open implant removal. Unfallchirurg. 2012;115(1):47–54.CrossRefPubMed Katthagen JC, Jensen G, Hennecke D, Lill H, Voigt C. Arthroscopic implant removal after fixed-angle plate osteosynthesis of the proximal humerus. Technique and initial results in comparison to open implant removal. Unfallchirurg. 2012;115(1):47–54.CrossRefPubMed
14.
Zurück zum Zitat Voigt C, Geisler A, Lill H. Arthroscopic locking plate removal after proximal humeral fractures. Arch Orthop Trauma Surg. 2010;130(3):391–5.CrossRefPubMed Voigt C, Geisler A, Lill H. Arthroscopic locking plate removal after proximal humeral fractures. Arch Orthop Trauma Surg. 2010;130(3):391–5.CrossRefPubMed
15.
Zurück zum Zitat Dines JS, Hettrich CM, Kelly BT, Savoie FH 3rd, Lorich DG. Arthroscopic removal of proximal humerus locking plates. Knee Surg Sports Traumatol Arthrosc. 2010;18(3):409–11.CrossRefPubMed Dines JS, Hettrich CM, Kelly BT, Savoie FH 3rd, Lorich DG. Arthroscopic removal of proximal humerus locking plates. Knee Surg Sports Traumatol Arthrosc. 2010;18(3):409–11.CrossRefPubMed
16.
Zurück zum Zitat Maroun C, Aliani D, Hass A, Werthel JD, Vidil A, Valenti P. Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years. Eur J Orthop Surg Traumatol. 2017;27(3):317–21.CrossRefPubMed Maroun C, Aliani D, Hass A, Werthel JD, Vidil A, Valenti P. Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years. Eur J Orthop Surg Traumatol. 2017;27(3):317–21.CrossRefPubMed
17.
Zurück zum Zitat Berrios-Torres SI, Umscheid CA, Bratzler DW, Leas B, Stone EC, Kelz RR, et al. Centers for disease control and prevention guideline for the prevention of surgical site infection, 2017. JAMA Surg. 2017;152(8):784–91.CrossRefPubMed Berrios-Torres SI, Umscheid CA, Bratzler DW, Leas B, Stone EC, Kelz RR, et al. Centers for disease control and prevention guideline for the prevention of surgical site infection, 2017. JAMA Surg. 2017;152(8):784–91.CrossRefPubMed
18.
Zurück zum Zitat Backes M, Dingemans SA, Dijkgraaf MGW, van den Berg HR, van Dijkman B, Hoogendoorn JM, et al. Effect of antibiotic prophylaxis on surgical site infections following removal of orthopedic implants used for treatment of foot, ankle, and lower leg fractures: a randomized clinical trial. JAMA. 2017;318(24):2438–45.CrossRefPubMed Backes M, Dingemans SA, Dijkgraaf MGW, van den Berg HR, van Dijkman B, Hoogendoorn JM, et al. Effect of antibiotic prophylaxis on surgical site infections following removal of orthopedic implants used for treatment of foot, ankle, and lower leg fractures: a randomized clinical trial. JAMA. 2017;318(24):2438–45.CrossRefPubMed
19.
Zurück zum Zitat Maqdes A, Levy B, Klouche S, Hardy P. The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures. Knee Surg Sports Traumatol Arthrosc. 2014;22(2):456–61.CrossRefPubMed Maqdes A, Levy B, Klouche S, Hardy P. The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures. Knee Surg Sports Traumatol Arthrosc. 2014;22(2):456–61.CrossRefPubMed
20.
Zurück zum Zitat Kim KC, Rhee KJ, Shin HD, Kim YM. Arthroscopic removal of an intramedullary nail in the humerus. Knee Surg Sports Traumatol Arthrosc. 2007;15(7):922–6.CrossRefPubMed Kim KC, Rhee KJ, Shin HD, Kim YM. Arthroscopic removal of an intramedullary nail in the humerus. Knee Surg Sports Traumatol Arthrosc. 2007;15(7):922–6.CrossRefPubMed
21.
Zurück zum Zitat Katthagen JC, Hennecke D, Jensen G, Ellwein A, Voigt C, Lill H. Arthroscopy after locked plating of proximal humeral fractures: implant removal, capsular release, and intra-articular findings. Arthroscopy. 2014;30(9):1061–7.CrossRefPubMed Katthagen JC, Hennecke D, Jensen G, Ellwein A, Voigt C, Lill H. Arthroscopy after locked plating of proximal humeral fractures: implant removal, capsular release, and intra-articular findings. Arthroscopy. 2014;30(9):1061–7.CrossRefPubMed
22.
Zurück zum Zitat Gardner MJ, Griffith MH, Dines JS, Briggs SM, Weiland AJ, Lorich DG. The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin Orthop Relat Res. 2005;434:123–9.CrossRef Gardner MJ, Griffith MH, Dines JS, Briggs SM, Weiland AJ, Lorich DG. The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin Orthop Relat Res. 2005;434:123–9.CrossRef
23.
Zurück zum Zitat Voleti PB, Camp CL, Sinatro AL, Dines JS. Arthroscopic removal of symptomatic proximal humerus locking plates with bone-void filler augmentation. Arthrosc Tech. 2016;5(2):e343–6.CrossRefPubMedPubMedCentral Voleti PB, Camp CL, Sinatro AL, Dines JS. Arthroscopic removal of symptomatic proximal humerus locking plates with bone-void filler augmentation. Arthrosc Tech. 2016;5(2):e343–6.CrossRefPubMedPubMedCentral
Metadaten
Titel
A novel implant removal technique by endoscopy
verfasst von
Chang Heng Liu
Wen Lin Yeh
Ping Jui Tsai
Kuo Feng Fan
Hung Wei Cheng
Jian Ming Chen
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
Journal of Orthopaedic Surgery and Research / Ausgabe 1/2018
Elektronische ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-018-0783-4

Weitere Artikel der Ausgabe 1/2018

Journal of Orthopaedic Surgery and Research 1/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.