A novel read methodology to evaluate the optimal dose of 68Ga-satoreotide trizoxetan as a PET imaging agent in patients with gastroenteropancreatic neuroendocrine tumours: a phase II clinical trial

verfasst von: Colin G. Miller, Henning Grønbæk, Irene Virgolini, Andreas Kjaer, Pierre Terve, Shadfar Bahri, Peter Iversen, Hanna Svirydenka, Thomas Rohban, Sandy McEwan

Erschienen in: EJNMMI Research | Ausgabe 1/2021

Abstract

Background

68Ga-satoreotide trizoxetan is a novel somatostatin receptor antagonist exhibiting higher tumour-to-background ratios and sensitivity compared to 68Ga-DOTATOC. This randomised, 2 × 3 factorial, phase II study aimed to confirm the optimal peptide mass and radioactivity ranges for 68Ga-satoreotide trizoxetan, using binary visual reading. To that end, 24 patients with metastatic gastroenteropancreatic neuroendocrine tumours received 5–20 µg of 68Ga-satoreotide trizoxetan on day 1 of the study and 30–45 µg on day 16–22, with one of three gallium-68  radioactivity ranges (40–80, 100–140, or 160–200 MBq) per visit. Two 68Ga-satoreotide trizoxetan PET/CT scans were acquired from each patient post-injection, and were scored by experienced independent blinded readers using a binary system (0 for non-optimal image quality and 1 for optimal image quality). For each patient pair of 68Ga-satoreotide trizoxetan scans, one or both images could score 1.

Results

Total image quality score for 68Ga-satoreotide trizoxetan PET scans was lower in the 40–80 MBq radioactivity range (56.3%) compared to 100–140 MBq (90.6%) and 160–200 MBq (81.3%). Both qualitative and semi-quantitative analysis showed that peptide mass (5–20 or 30–45 µg) did not influence 68Ga-satoreotide trizoxetan imaging. There was only one reading where readers diverged on scoring; one reader preferred one image because of higher lesion conspicuity, and the other reader preferred the alternative image because of the ability to identify more lesions.

Conclusions

Binary visual reading, which was associated with a low inter-reader variability, has further supported that the optimal administered radioactivity of 68Ga-satoreotide trizoxetan was 100–200 MBq with a peptide mass up to 50 µg.
Trial registration ClinicalTrials.gov, NCT03220217. Registered 18 July 2017, https://​clinicaltrials.​gov/​ct2/​show/​NCT03220217
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
CT
computed tomography
CTN
clinical trials network
GCP
good clinical practice
GEP
gastroenteropancreatic
IQS
image quality score
NET
neuroendocrine tumour
PET
positron emission tomography
SNMMI
society of nuclear medicine and molecular imaging
SSTR
somatostatin receptor
SUV
standardised uptake value
SUVmax
maximum standardised uptake value

Background

The use of 68Ga-radiolabelled somatostatin receptor (SSTR) agonists, such as 68Ga-DOTATATE and 68Ga-DOTATOC, for the positron emission tomography/computed tomography (PET/CT) imaging of neuroendocrine tumours (NETs) is well-established in clinical practice, not only for the localisation and staging of NETs, but also as a theranostic tool or biomarker for assessing the potential response to peptide receptor radionuclide therapy [1]. In the evaluation of new imaging techniques and novel tracers, image quality is usually assessed using a 5-point Likert scale: the exact methodology of which is unique to each clinical trial, but standardly “1” is poor quality and “5” is high quality [29]. Despite its widespread use, the Likert scale in biomedical imaging assessment is limited by inter-reader variability, fixed upper and lower limits, and a lack of mathematical and statistical validity [1012].
To the authors’ knowledge, the binary evaluation of image quality in nuclear medicine (wherein an individual reader sees two images simultaneously and designates them as having either optimal or non-optimal image quality) has not been previously described, although binary reading of PET images has been used in the evaluation of the presence or absence of amyloid in Alzheimer's disease [13, 14]. Unlike the Likert assessment, an important advantage of binary visual reading is its simplicity and convenience, as it removes the need for images to be reviewed at different times, particularly in studies with a small number of images. These features suggest that binary contemporaneous visual reading might be used to optimise clinical development of PET/CT imaging agents.
The use of radiolabelled SSTR antagonists rather than agonists has the potential to improve the PET/CT imaging of NETs, because SSTR antagonists bind to significantly more receptor sites than SSTR agonists [15]. 68Ga-satoreotide trizoxetan (also known as 68Ga-IPN01070, 68Ga-NODAGA-JR11, or 68Ga-OPS202) is a novel SSTR antagonist recently evaluated in a prospective phase I/II imaging study conducted in 12 patients with well-differentiated gastroenteropancreatic (GEP) NETs. The authors showed that compared with 68Ga-DOTATOC, 68Ga-satoreotide trizoxetan exhibits substantially higher tumour-to-background ratios and sensitivity for detecting liver metastases [16, 17]. Subsequently, a phase II study was conducted to confirm the optimal administered peptide mass and radioactivity of 68Ga-satoreotide trizoxetan in patients with GEP-NETs [18].
The primary results of this phase II study [18] showed that the ratio of the number of lesions detected by 68Ga-satoreotide trizoxetan imaging to the number of lesions detected by contrast-enhanced CT was overall consistent across different peptide mass and radioactivity range combinations (5–20 or 30–45 µg with one of three gallium-68 radioactivity ranges: 40–80, 100–140, or 160–200 MBq). However, a trend towards a lower ratio in the liver was noted for the radioactivity range of 40–80 MBq compared to higher radioactivity ranges. There were no safety concerns associated with 68Ga-satoreotide trizoxetan.
When comparing different peptide mass and radioactivity combinations of an imaging agent, a key aspect is the evaluation of image quality. We hypothesised that a binary visual reading technique comparing the images contemporaneously (rather than a multi-scoring technique in multiple review sessions) could reduce the readers’ workload and inter-reader variability, and thus improve the key endpoint assessment. Accordingly, here, we report the binary visual reading results in the aforementioned phase II study aimed to determine the optimal peptide mass and radioactivity ranges for 68Ga-satoreotide trizoxetan in patients with GEP-NETs.

Methods

Study design and patient population

This prospective, multinational, multicentre, dose-confirmation phase II study (ClinicalTrials.gov identifier: NCT03220217; EudraCT No.: 2016-004928-39) was conducted between September 2017 and August 2019, using an open-label, reader-blinded, 2 × 3 factorial design. The methodology and primary results have been reported elsewhere [18]. In summary, a total of 24 adult patients with well-differentiated, metastatic, grade 1/2, SSTR-positive GEP-NETs were randomised (1:1:1) to one of three arms (8 patients per arm) with six peptide mass/radioactivity range combinations of 68Ga-satoreotide trizoxetan. Essentially, all patients received two different doses of 68Ga-satoreotide trizoxetan in one of the three arms on two consecutive visits separated by a 2–3-week interval, thereby providing a pair of PET/CT images for each patient (Fig. 1). The administered peptide mass range for all three arms was 5–20 µg on visit 1 (day 1 of the study) and 30–45 µg on visit 2 (day 16–22). The radioactivity range was for:
  • Arm A: 40–80 MBq (visit 1) and 100–140 MBq (visit 2)
  • Arm B: 100–140 MBq (visit 1) and 160–200 MBq (visit 2)
  • Arm C: 160–200 MBq (visit 1) and 40–80 MBq (visit 2)
All patients had a SSTR agonist PET/CT scan acquired within the previous six months of study enrolment. The main exclusion criteria were the presence of < 5 lesions in total and > 25 lesions per organ detected by the screening SSTR PET/CT scan in either the liver, lymph nodes, bones, or lungs; treatment with a somatostatin analogue within 28 days before 68Ga-satoreotide trizoxetan administration; and any condition that might preclude the proper performance of a PET and/or CT scan (e.g., patient body weight > 110 kg; inability to raise arms for prolonged imaging purposes or to lie still for the entire imaging time).
The study was performed in four investigational sites in Austria, Denmark and the USA, and was conducted in accordance with the Declaration of Helsinki as well as the Good Clinical Practice (GCP) guidelines. Ethics committee approval was obtained at each participating site, and all patients provided written informed consent.

PET/CT imaging protocol

An image core laboratory (Rad-MD, New York City, New York, USA) provided a comprehensive, manufacturer-specific image acquisition manual, which detailed the requirements for the investigator site personnel to ensure inter-site consistency of image acquisition protocols across scanners and sites.
On both day 1 and day 16–22 study visits, whole-body PET/CT imaging (from skull base to mid-thigh) was performed for all patients 50–70 min after the intravenous injection of 68Ga-satoreotide trizoxetan, using either Siemens Biograph dedicated PET/CT scanners or GE Discovery 690 PET/CT scanners at each of the four study centres. Three-dimensional PET scans were acquired in list mode, with a 4 min per bed position and a 5-slice overlap. CT scan was performed using intravenous iodinated contrast media, with a maximum slice thickness of 3 mm.
The effective administered activity of 68Ga-satoreotide trizoxetan (defined as the activity in the syringe before injection minus the residual activity in the empty syringe after injection) was used for PET image reconstruction. PET/CT data were volume rendered with maximum intensity projection for PET and direct volume rendering for CT. No fasting or dietary restrictions were imposed on study participants prior to PET/CT imaging.
All trial sites qualified their PET scanners using the Clinical Trials Network (CTN) of the Society of Nuclear Medicine and Molecular Imaging (SNMMI) Scanner Validation Program to ensure baseline common quality control metrics for PET scanners used across the sites [19]. Before imaging patients at each study site, the PET/CT scanner was cross-calibrated to a well counter calibrated for gallium-68using a homogeneously filled phantom; the phantom was used to ensure that PET/CT scanner images were comparable and reproducible across the study sites for image noise and texture. PET imaging data were collected and confirmed by the SNMMI CTN, to ensure the standardised uptake values (SUV) used in the trial were reliable.
In addition, quality control by the imaging core laboratory was performed on all acquired 68Ga-satoreotide trizoxetan PET/CT scans. In case of detection of patient movement-related artifacts, a scan repeat would be requested, or a patient would be replaced.

Qualitative imaging analysis

Following anonymisation, 68Ga-satoreotide trizoxetan PET/CT scans were all sent to an imaging core laboratory (Keosys, Nantes, France), and evaluated centrally. A total of 48 PET/CT images were read: two for each of the 24 patients acquired at the two study visits, with 8 images in each peptide mass/radioactivity range combination. Prior to initiating the PET/CT image reads, a formal study training day, including a “calibration” agreement session, was conducted in New York, with all readers present. 68Ga-satoreotide trizoxetan images acquired in the Nicolas et al. (2018) phase I/II study of 12 patients with well-differentiated GEP-NETs [16, 17] were used for training, in a blinded manner by all readers to evaluate inter-reader consistency and to reach consensus on areas of interpretative difference.
The read design schema is shown in Fig. 2, with a total of six read sessions. All readers were blinded to all patient identification, clinical data, and to any information related to the study site, visit, and administered peptide mass and radioactivity. To maintain consistency, the patients’ PET/CT scans were read in batches of approximately six patients. The 68Ga-satoreotide trizoxetan PET images were read either alone (read 1A and 1B) or as a fused PET/CT scan (read 2A and 2B) by two different pairs of nuclear medicine physicians. In parallel, the contrast-enhanced CT scans, which were used for statistical comparisons, were independently read by two radiologists (read 3). The 68Ga-satoreotide trizoxetan PET and PET/CT images were randomised in presentation sequence (visit 1 or visit 2) so as to blind the readers from the timepoint and administered dose, with a minimum interval of 14 days between the two reads in an attempt to decrease reader image memory and possible recall bias. The purpose of the read 1A, read 2A, and read 3 sessions was to count the number of lesions per organ on each patient scan, with the use of an adjudication paradigm during read session 4 in case of a > 10% discrepancy between the two independent readers in the lesion count.
Reads 1B and 2B were separate image quality read sessions where the two 68Ga-satoreotide trizoxetan scans acquired from the same patient were presented to the two experienced nuclear medicine physicians for visual assessment, using a split screen technique. Both physicians read the images independently without reference to the other. Each reader directly compared the paired patient images contemporaneously, recording which of the pair provided optimal image quality. Both readers had the ability to use window/level manipulation on each reviewed image. 68Ga-satoreotide trizoxetan PET and PET/CT scans were scored in two different sessions using a binary system (0 for non-optimal image quality and 1 for optimal image quality). For each patient pair of 68Ga-satoreotide trizoxetan scans, one or both images could score 1. Both primary readers’ scores were subsequently combined providing a maximum total image quality score (IQS) of 16 per peptide mass/radioactivity range combination (8 images × 2 readers). No adjudications were held for the image quality reads (reads 1B and 2B).

Quantitative analysis

During a subsequent reading session (read 5), another independent, qualified reader, not involved in the 68Ga-satoreotide trizoxetan or contrast-enhanced CT image reads, reviewed all 48 PET/CT scans, in order to perform the semi-quantitative measurements of maximum standardised uptake values (SUVmax) to support the qualitative imaging analysis. Spherical regions of interest were manually drawn by the reader in up to the five most avid lesions detected in the primary tumour site, liver, lymph nodes, bones, and lungs. As a reference tissue, the SUVmean of non-tumoural liver parenchyma was measured in a 3-cm region of interest in all 68Ga-satoreotide trizoxetan PET/CT scans while avoiding large vessels. The tumour-to-liver ratio was calculated as lesion SUVmax/non-tumoural liver parenchyma SUVmean for each pre-defined anatomic region, and was determined across the different peptide mass and radioactivity ranges.

Statistical analysis

This was a descriptive analysis. As prespecified in the Statistical Analysis Plan, 24 patients were to be included in the per-protocol population (the first eight patients in each arm) to ensure balanced arms and paired reading of images for comparability across doses. Categorical variables were expressed as counts and percentages, and continuous variables as mean ± standard deviation or median (range), depending on the distribution of values. All imaging endpoints were also evaluated based on the administered radioactivity (MBq) per patient’s baseline body weight (kg) in four distinct subgroups: 0.69–0.97, 0.97–1.55, 1.55–2.09, and 2.09–3.72 MBq/kg.
Statistical analyses were performed using SAS version 9.4 (SAS Institute Inc, Cary, NC). Missing values were not replaced.

Results

Patients

The baseline demographic characteristics of the study population are presented in Table 1. Overall, 21/24 (87.5%) patients had intestinal NETs, and 3 (12.5%) pancreatic NETs. The liver (in 22/24 patients; 91.7%) and lymph nodes (19/24; 79.2%) were the most frequent locations of metastases.
Table 1
Baseline demographic characteristics in the per-protocol population
Parameter
Arm A (N = 8)
Arm B (N = 8)
Arm C (N = 8)
Overall (N = 24)
Age, years
71.5 (54–84)
65.5 (60–72)
60.5 (48–76)
62.5 (48–84)
Sex
    
 Male
6 (75.0)
3 (37.5)
7 (87.5)
16 (66.7)
 Female
2 (25.0)
5 (62.5)
1 (12.5)
8 (33.3)
Body weight, kg
81.0 (77–98)
87.5 (52–109)
87.5 (60–105)
85.0 (52–109)
Height, cm
175.5 (162–189)
171.0 (159–185)
177.5 (171–189)
176.0 (159–189)
BMI, kg/m2
26.4 (24–35)
28.8 (21–34)
26.6 (19–31)
26.7 (19–35)
ECOG performance status
 0 (normal activity)
7 (87.5)
7 (87.5)
7 (87.5)
21 (87.5)
 1 (restricted activity)
1 (12.5)
1 (12.5)
1 (12.5)
3 (12.5)
Data are presented as n (%) or median (range). Percentages are calculated as n/N
BMI body mass index, ECOG Eastern Cooperative Oncology Group
All 24 patients had a prior SSTR scan acquired within a median of 1.6 months (range, 0.1–6.0 months) from screening: 14 (58.3%) with 68Ga-DOTATOC, 9 (37.5%) with 64Cu-DOTATATE, and 1 (4.2%) with 68Ga-DOTATATE. The total number of SSTR-positive lesions, expressed as median (range), detected by prior SSTR agonist scans was 14.5 (6.0–94.0), with 1.0 lesions (0–1.0) in the primary tumour site, 9.5 (0–37.0) in the liver, 5.0 (0–36.0) in the lymph nodes, and 0.5 (0–38.0) in the bones. Three patients were enrolled with over 30 lesions identified in the liver or in the lymph nodes.

Image quality

The IQSs are presented in Table 2 for both the 68Ga-satoreotide trizoxetan PET/CT and PET only reads. The IQSs were overall similar across the three radioactivity ranges for the PET/CT reads. However, for the PET only reads, the total IQS was lower in the 40–80 MBq radioactivity range (56.3%) compared to the 100–140 MBq (90.6%) and 160–200 MBq (81.3%) ranges. With regard to the evaluated peptide mass ranges, the total IQSs were 60.4% in the 5–20 µg peptide mass range and 83.3% in the 30–45 µg peptide mass range for the PET/CT readings. For the PET only readings, the total IQSs were 70.8% and 81.3% in the 5–20 and 30–45 µg ranges, respectively.
Table 2
Image quality scores for 68Ga-satoreotide trizoxetan PET/CT and PET, by peptide mass and radioactivity range
Peptide mass range
Radioactivity range
40–80 MBq
100–140 MBq
160–200 MBq
Total
PET/CT readings
 
 5–20 µg
9/16 (56.3)
10/16 (62.5)
10/16 (62.5)
29/48 (60.4)
 30–45 µg
13/16 (81.2)
14/16 (87.5)
13/16 (81.3)
40/48 (83.3)
 Total
22/32 (68.8)
24/32 (75.0)
23/32 (71.9)
PET readings
 
 5–20 µg
7/16 (43.8)
14/16 (87.5)
13/16 (81.3)
34/48 (70.8)
 30–45 µg
11/16 (68.8)
15/16 (93.8)
13/16 (81.3)
39/48 (81.3)
 Total
18/32 (56.3)
29/32 (90.6)
26/32 (81.3)
During the image quality readings, each image was assigned a “1” (for optimal image quality) or a “0” (for non-optimal image quality). For each pair of patient images of 68Ga-satoreotide trizoxetan obtained on day 1 and day 16–22 of the study, one or both images could score “1”. The numerator of the image quality score is the sum of both readers’ scores, and the denominator is the total number of PET/CT and PET scans that were read and scored
Data are presented as n/N (%)
CT computed tomography, PET positron emission tomography
IQSs based on the administered radioactivity per patient’s body weight are presented in Table 3. While the overall results were similar for the evaluated quartiles of body mass, the IQSs in the 5–20 µg range were in general lower than that in the 30–45 µg peptide mass range, particularly for the 68Ga-satoreotide trizoxetan PET/CT readings.
Table 3
Image quality scores for 68Ga-satoreotide trizoxetan PET/CT and PET, by radioactivity per patient’s body weight
 
0.69–0.97 MBq/kg
0.97–1.55 MBq/kg
1.55–2.09 MBq/kg
2.09–3.72 MBq/kg
Total
PET/CT readings
 
 5–20 µg
9/16 (56.3)
6/10 (60.0)
7/12 (58.3)
7/10 (70.0)
29/48 (60.4)
 30–45 µg
9/12 (75.0)
9/10 (90.0)
11/14 (78.6)
11/12 (91.7)
40/48 (83.3)
 Total
18/28 (64.3)
15/20 (75.0)
18/26 (69.2)
18/22 (81.8)
PET readings
 
 5–20 µg
7/16 (43.8)
9/10 (90.0)
9/12 (75.0)
9/10 (90.0)
34/48 (70.8)
 30–45 µg
8/12 (66.7)
8/10 (80.0)
12/14 (85.7)
11/12 (91.7)
39/48 (81.3)
 Total
15/28 (53.6)
17/20 (85.0)
21/26 (80.8)
20/22 (90.9)
During the image quality readings, each image was assigned a “1” (for optimal image quality) or a “0” (for non-optimal image quality). The numerator of the image quality score is the sum of both readers’ scores, and the denominator is the total number of PET/CT and PET scans that were read and scored
Data are presented as n/N (%)
CT computed tomography, PET positron emission tomography
During the image quality read sessions, there was only one reading where the readers diverged on scoring; one reader preferred one image because of higher lesion conspicuity, and the other reader preferred the alternative image because of the ability to identify more lesions. All other reads were congruent in that the readers agreed on at least one of the images having an IQS of 1. Compared to 68Ga-satoreotide trizoxetan PET/CT readings, both primary readers reported that it was overall more difficult to localise hepatic and pulmonary lesions in PET only readings.
A pair of 68Ga-satoreotide trizoxetan PET/CT fused images acquired from the same patient at the two study timepoints is illustrated in Fig. 3.

Semi-quantitative assessment

SUVmax and the tumour-to-liver ratio (SUVmax/SUVmean) were evaluated on all 68Ga-satoreotide trizoxetan scans, and the results were compared across the peptide mass and radioactivity range combinations, with no consistent pattern in the median values identified (Table 4). Similarly, when assessing tumour-to-liver ratio by peptide mass range and radioactivity range (Table 5), no notable differences in the mean and median ratios were observed. There was also no apparent relationship between the radioactivity range per patient’s body weight and SUVmax of the liver and lymph nodes (Table 6).
Table 4
SUVmax and tumour-to-liver ratio for the liver and lymph nodes, by combination
 
Arm A (N = 8)
Arm B (N = 8)
Arm C (N = 8)
Organ
Statistic
5–20 µg
40–80 MBq
30–45 µg
100–140 MBq
5–20 µg
100–140 MBq
30–45 µg
160–200 MBq
5–20 µg
160–200 MBq
30–45 µg
40–80 MBq
SUVmax
 Liver
n
5
5
5
5
8
8
Median (range)
24.2 (18.25–49.16)
22.9 (18.01–59.83)
9.5 (6.74–63.68)
16.0 (9.56–78.43)
12.4 (6.95–30.07)
17.7 (10.62–30.28)
 Lymph nodes
n
3
3
6
6
5
5
Median (range)
24.7 (19.52–40.74)
35.7 (16.69–41.11)
28.5 (9.03–83.06)
27.7 (5.25–53.79)
13.8 (6.08–21.73)
12.7 (6.15–21.33)
Tumour-to-liver ratio (SUVmax/SUVmean)
 Liver
n
5
5
5
5
8
8
Median (range)
9.9 (8.51–37.00)
8.4 (7.27–28.31)
6.0 (4.85–40.14)
7.0 (5.08–48.79)
7.2 (3.28–17.98)
9.3 (5.60–32.37)
 Lymph nodes
n
3
3
6
6
5
5
Median (range)
18.6 (6.17–27.43)
16.9 (4.83–21.50)
9.9 (4.42–26.46)
13.6 (2.26–25.14)
9.8 (5.30–20.45)
8.2 (5.56–28.98)
n corresponds to the number of patients with lesions in either the liver or the lymph nodes
The number of patients with lesions in the bones, lungs, and the primary tumour site was too small (≤ 3 in each category) to allow a meaningful interpretation of PET/CT scans for these organs
CT computed tomography, PET positron emission tomography, SUV standardised uptake value
Table 5
Tumour-to-liver (SUVmax/SUVmean), by peptide mass and radioactivity range
 
Peptide mass range
Radioactivity range
Organ
Statistic
5–20 µg (N = 24)
30–45 µg (N = 24)
40–80 MBq (N = 16)
100–140 MBq (N = 16)
160–200 MBq (N = 16)
Primary tumour site
n
6
5
3
5
3
Mean ± SD
32.1 ± 39.22
29.2 ± 28.01
41.4 ± 53.08
30.1 ± 27.67
21.3 ± 27.78
Median (range)
12.6 (4.94–102.40)
16.5 (5.57–64.98)
16.2 (5.67–102.40)
16.5 (5.31–64.98)
5.6 (4.94–53.36)
Liver
n
18
18
13
10
13
Mean ± SD
11.5 ± 10.51
13.6 ± 11.72
12.9 ± 9.94
13.0 ± 11.87
11.8 ± 12.20
Median (range)
8.6 (3.28–40.14)
8.4 (5.08–48.79)
9.9 (5.60–37.00)
7.7 (4.85–40.14)
7.0 (3.28–48.79)
Lymph nodes
n
14
14
8
9
11
Mean ± SD
13.2 ± 8.52
13.1 ± 8.98
13.8 ± 9.78
13.7 ± 8.93
12.3 ± 8.18
Median (range)
10.1 (4.42–27.43)
8.6 (2.26–28.98)
8.6 (5.56–28.98)
10.8 (4.42–26.46)
9.8 (2.26–25.14)
n corresponds to the number of patients with lesions in either the primary tumour site, liver, or the lymph nodes
The number of patients with lesions in the bones and lungs was too small (≤ 1 in each category) to allow a meaningful interpretation of PET/CT scans for these organs
CT computed tomography, PET positron emission tomography, SD standard deviation, SUV standardised uptake value
Table 6
SUVmax of the liver and lymph nodes, by radioactivity per patient’s body weight
Organ
Statistic
0.69–0.97 MBq/kg
0.97–1.55 MBq/kg
1.55–2.09 MBq/kg
2.09–3.72 MBq/kg
Liver
N
11
6
9
8
Mean ± SD
24.4 ± 9.46
13.8 ± 5.49
16.1 ± 7.25
23.3 ± 17.77
Median (range)
23.8 (15.0–49.0)
12.6 (8.0–22.0)
14.8 (7.0–26.0)
14.1 (10.0–60.0)
Lymph nodes
N
5
6
7
8
Mean ± SD
25.5 ± 8.72
34.3 ± 26.46
29.2 ± 15.75
17.9 ± 11.81
Median (range)
21.3 (20.0–41.0)
28.5 (12.0–83.0)
21.7 (13.0–54.0)
13.0 (5.0–36.0)
n corresponds to the number of patients with lesions in either the liver or the lymph nodes
The number of patients with lesions in the primary tumour site and bones was too small (≤ 3 in each category) to allow a meaningful interpretation of PET/CT scans for these organs
CT computed tomography, PET positron emission tomography, SD standard deviation, SUVmax maximum standardised uptake value

Discussion

In this study, we evaluated a binary visual reading methodology to reduce the readers’ workload and inter-reader variability, and improve study endpoints’ assessment following administration of a 68Ga-labelled radiopharmaceutical. The main finding was that a binary scoring system evaluating image quality in a contemporaneous manner was indeed useful in appraising image quality in a reader-centric manner with a low inter-reader variability, and can consequently be recommended for future evaluation of imaging studies.
The evaluation of image quality in product development and clinical trials is most commonly assessed by using the 5-point Likert scale as a qualitative index [2022] requiring multiple reader sessions. A Likert scoring methodology, while providing the appearance of a robust evaluation, has several practical and methodological challenges. Most importantly, it requires user (reader) calibration to define the exact metric to each unit of score. Without careful definition and calibration, there will be mismatch errors among the readers which might lead to significant statistical noise, as there is potentially more discrepancy in the interpretation of the score values than within the images themselves. Furthermore, the use of a Likert scale requires a relatively large sample size. By comparison, the methodology presented here relies on a small pre-determined balanced approach requiring far fewer patients to be enrolled and a forced direct image comparison creating an IQS. The approach of comparing two doses of 68Ga-satoreotide trizoxetan using a split screen technique simplified the readers’ work and provided more robust responses to the challenge of selecting one of two images. The binary visual reading technique, while described elsewhere, does not, surprisingly, appear to have been widely adopted in the imaging field and in the nuclear medicine arena. The obvious advantage of a reduced number of patients being involved makes a compelling argument for future consideration of binary contemporaneous visual reading for image evaluation. As noted, there was only one discrepant reading between the two primary readers in our study, supporting the hypothesis that a binary scoring system would lead to low inter-reader variability and evaluate image quality in a reader-centric manner.
Besides the adoption of a binary contemporaneous visual reading scoring system, a blinded independent central review, which has been reported to increase the reproducibility of study results [20, 23], was performed to optimise qualitative image evaluation of 68Ga-satoreotide trizoxetan PET/CT scans in this study. In addition, by omitting clinical and dosing data as well as information on the study site and timepoints, the blinded reads provided pure imaging data results. Reading/interpretation bias was further reduced by the adoption of a multiple randomisation scheme. Of note, when evaluating novel radiopharmaceuticals, it is important that the read methodology is carefully described to meet the needs of regulatory agencies such as the United States Food and Drug Administration [2427].
A key contributing factor to ensuring successful image quality assessment is carefully designed acquisition protocols, with strict quality control. This was accomplished with the support of the imaging core labs (Rad-MD, Keosys, and SNMMI CTN) and the investigator sites ensuring that patients were imaged according to the study protocol and GCP guidelines. Another key aspect is the reader training/calibration, which was conducted face to face, and included the use of images acquired in the aforementioned Nicolas et al. (2018) phase I/II study [16, 17] to accustom the readers to evaluating 68Ga-satoreotide trizoxetan PET/CT and to provide initial inter-reader variability information.
In terms of radioactivity ranges, the IQSs for the 68Ga-satoreotide trizoxetan PET/CT and PET only scans were lower for the 40–80 MBq range, especially with the PET only images. These results, along with the other published data from the study [18], confirmed that this radioactivity range of 68Ga-satoreotide trizoxetan cannot be recommended for phase III development, particularly given that it has never been evaluated in prior studies with other 68Ga-labelled agents. The combination of 40–80 MBq and 5–20 µg appears to have the poorest quality of reads, as illustrated by the IQSs for 68Ga-satoreotide trizoxetan PET/CT and PET only scans when compared to other peptide mass and radioactivity range combinations, suggesting a potential peptide mass dose effect. However, once the combination of 40–80 MBq and 5–20 µg is ignored, the differences in IQSs across the evaluated peptide mass and radioactivity range combinations are reduced, particularly for the PET only reads. Moreover, the semi-quantitative analysis showed no notable differences in the mean and median values of SUVmax and SUVmax/SUVmean for the liver and lymph nodes across the evaluated peptide mass and radioactivity range combinations. Therefore, the overall results lead to the conclusion that peptide mass does not influence 68Ga-satoreotide trizoxetan imaging. This is in line with the Nicolas et al. (2018) phase I/II imaging study [16, 17] in which two peptide masses (15 and 50 µg) of 68Ga-satoreotide trizoxetan were injected in 12 patients with GEP-NETs. There were no significant differences between the two peptide masses in the numbers of malignant liver or lymph node lesions detected per patient and in tumour uptake [16, 17].
Data regarding the optimal peptide mass range of radiolabelled SSTR antagonists used for functional NET imaging are scarce [28, 29]. Currently, a peptide mass up to 50 µg is used for imaging, as per current administration guidelines for 68Ga-labelled radiopharmaceuticals [30], to avoid the risk of receptor saturation and to allow accurate quantification of the receptor density [28, 29]. However, this recommended peptide mass range is more reflective of common practice than of evidence from controlled studies [28]. Nevertheless, the results of the present study support an optimal peptide mass of 68Ga-satoreotide trizoxetan up to 50 µg for the diagnostic imaging of GEP-NETs.
This present study also supports the administration of a radioactivity range of 68Ga-satoreotide trizoxetan between 100 and 200 MBq, which is in line with the Oncology Committee of the European Association of Nuclear Medicine’s procedural guidelines for PET/CT tumour imaging with 68Ga-conjugated peptides [30]. To ensure a high diagnostic quality of 68Ga-satoreotide trizoxetan PET/CT examination and to avoid negative impacts on image quality or lesion detectability [5], it is not recommended to reduce the administrated radioactivity below 100 MBq. Of note, in a prospective study among 24 patients with SSTR-positive NETs who received a single intravenous injection of 68Ga-DOTATOC administered at a mean dose of 120 MBq, both 68Ga-DOTATOC PET/CT and PET/magnetic resonance imaging were associated with good image quality and detectability of focal PET lesions on both a patient basis and organ system basis [31]. In the present study, the total IQS for 68Ga-satoreotide trizoxetan PET scans was higher in the 100–140 MBq radioactivity range (90.6%) compared to the 160–200 MBq (81.3%) range, suggesting a possibility of narrowing the radioactivity window of 68Ga-satoreotide trizoxetan from 100–200 to 100–140 MBq. However, adopting the wider, guideline-recommended radioactivity range of 100–200 MBq offers increased flexibility and feasibility in routine clinical practice, while maintaining similarity in dosing to other gallium-68-labelled products [30]. The absence of a clear radioactive dose–response relationship in the present study might be related to factors such as heterogeneity in receptor density, hypoxia, interstitial pressure, necrosis, and tumour heterogeneity [32].
This study was mainly limited by a small sample size, the use of a descriptive statistical analysis only, the lack of a direct comparison between binary contemporaneous visual reading and the Likert scale system, and the absence of a comparator arm to evaluate the repeatability of the imaging results. In addition, inter- and intra-reader variabilities were not quantified. However, to minimise inter-reader variability, a full reader training which included the binary visual reading of 68Ga-satoreotide trizoxetan PET/CT scans acquired in the Nicolas et al. (2018) phase I/II study [16, 17] was undertaken prior to the start of the study. Analyses of tumour SUV were also restricted to measurement of SUVmax. Although semi-quantitative assessments using SUVmax may allow a more uniform evaluation of the diagnostic value of 68Ga-satoreotide trizoxetan [33], the number of patients in the present study with lesions in the bones, lungs, and the primary tumour site was too small to draw conclusions for these organs on the differences in the mean and median values of SUVmax and SUVmax/SUVmean across the administered peptide mass and radioactivity ranges. This study nevertheless had several strengths, particularly a robust research design allowing inter- and intra-individual comparisons of different peptide mass and radioactivity range combinations, the adoption of a novel read methodology providing direct image comparisons and consequently removing the subjectivity of inter-timepoint variations, the utilisation of a blinded independent central review, the inclusion of both quantitative and qualitative imaging measures, and a uniform PET/CT imaging protocol across all study sites. Based on the results of the present study, 68Ga-satoreotide trizoxetan administered at 100–200 MBq with a peptide mass up to 50 μg will be further evaluated in larger prospective clinical studies.

Conclusions

This study provided the opportunity to develop a simple and precise image quality scoring system, associated with a low inter-reader variability. This binary contemporaneous scoring system can consequently be recommended for future evaluation of imaging studies. The read quality results in the present study, along with the results reported elsewhere [18], confirm an optimal administered radioactivity of 68Ga-satoreotide trizoxetan of 100–200 MBq with a peptide mass up to 50 μg for future clinical development.

Acknowledgements

The authors would like to thank: all patients involved in the study, their caregivers, care team, investigators and research staff in the participating institutions; Partner 4 Health (Paris, France) for providing medical writing support (sponsored by Ipsen, Boulogne, France) in accordance with Good Publication Practice (GPP3) guidelines; the independent readers—Dr. Daniele Marin, Dr. Giuseppe Esposito, Dr. Gregg Miller, Dr. Gregory Sicca, Dr. Narainder Gupta, Dr. Rendon Nelson, and Dr. Gabriel Soudry; Rad-MD for their support and management of the readers and Keosys for the images and read platform.

Declarations

The study was performed in four investigational sites in Austria, Denmark and the United States, and was conducted in accordance with the Declaration of Helsinki as well as the Good Clinical Practice guidelines. Ethics committee approval was obtained at each participating site, and all patients provided written informed consent.
Not applicable.

Competing interests

CGM has acted as a consultant for Ipsen, CytoSite Bio and Alacrita, and is a managing partner at the Bracken Group. HG serves on the advisory board of Ipsen. IV has acted as a consultant for Ipsen and Advanced Accelerator Applications. AK has served on the advisory board of Ipsen. PT is an employee at Keosys. TR is a managing partner at Partner 4 Health, and has acted as a consultant for Ipsen. SM is an employee at Ipsen Bioscience (Cambridge, MA, USA). No other potential conflict of interest relevant to this article was reported.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Tirosh A, Kebebew E. The utility of 68Ga-DOTATATE positron-emission tomography/computed tomography in the diagnosis, management, follow-up and prognosis of neuroendocrine tumors. Future Oncol. 2018;14:111–22.CrossRef Tirosh A, Kebebew E. The utility of 68Ga-DOTATATE positron-emission tomography/computed tomography in the diagnosis, management, follow-up and prognosis of neuroendocrine tumors. Future Oncol. 2018;14:111–22.CrossRef
2.
Zurück zum Zitat Partovi S, Kohan A, Gaeta C, Rubbert C, Vercher-Conejero JL, Jones RS, et al. Image quality assessment of automatic three-segment MR attenuation correction vs. CT attenuation correction. Am J Nucl Med Mol Imaging. 2013;3:291–9.PubMedPubMedCentral Partovi S, Kohan A, Gaeta C, Rubbert C, Vercher-Conejero JL, Jones RS, et al. Image quality assessment of automatic three-segment MR attenuation correction vs. CT attenuation correction. Am J Nucl Med Mol Imaging. 2013;3:291–9.PubMedPubMedCentral
3.
Zurück zum Zitat Messerli M, Stolzmann P, Egger-Sigg M, Trinckauf J, D’Aguanno S, Burger IA, et al. Impact of a Bayesian penalized likelihood reconstruction algorithm on image quality in novel digital PET/CT: clinical implications for the assessment of lung tumors. EJNMMI Phys. 2018;5:27.CrossRef Messerli M, Stolzmann P, Egger-Sigg M, Trinckauf J, D’Aguanno S, Burger IA, et al. Impact of a Bayesian penalized likelihood reconstruction algorithm on image quality in novel digital PET/CT: clinical implications for the assessment of lung tumors. EJNMMI Phys. 2018;5:27.CrossRef
4.
Zurück zum Zitat Sonni I, Baratto L, Park S, Hatami N, Srinivas S, Davidzon G, et al. Initial experience with a SiPM-based PET/CT scanner: influence of acquisition time on image quality. EJNMMI Phys. 2018;5:9.CrossRef Sonni I, Baratto L, Park S, Hatami N, Srinivas S, Davidzon G, et al. Initial experience with a SiPM-based PET/CT scanner: influence of acquisition time on image quality. EJNMMI Phys. 2018;5:9.CrossRef
5.
Zurück zum Zitat Rauscher I, Fendler WP, Hope TA, Quon A, Nekolla SG, Calais J, et al. Can the injected dose be reduced in 68Ga-PSMA-11 PET/CT while maintaining high image quality for lesion detection? J Nucl Med. 2020;61:189–93.CrossRef Rauscher I, Fendler WP, Hope TA, Quon A, Nekolla SG, Calais J, et al. Can the injected dose be reduced in 68Ga-PSMA-11 PET/CT while maintaining high image quality for lesion detection? J Nucl Med. 2020;61:189–93.CrossRef
6.
Zurück zum Zitat Murthy V, Smith RL, Tao DH, Lawhn-Heath CA, Korenchan DE, Larson PEZ, et al. 68Ga-PSMA-11 PET/MRI: determining ideal acquisition times to reduce noise and increase image quality. EJNMMI Phys. 2020;7:54.CrossRef Murthy V, Smith RL, Tao DH, Lawhn-Heath CA, Korenchan DE, Larson PEZ, et al. 68Ga-PSMA-11 PET/MRI: determining ideal acquisition times to reduce noise and increase image quality. EJNMMI Phys. 2020;7:54.CrossRef
7.
Zurück zum Zitat van Sluis J, Boellaard R, Somasundaram A, van Snick PH, Borra RJH, Dierckx RAJO, et al. Image quality and semiquantitative measurements on the biograph vision PET/CT system: initial experiences and comparison with the biograph mCT. J Nucl Med. 2020;61:129–35.CrossRef van Sluis J, Boellaard R, Somasundaram A, van Snick PH, Borra RJH, Dierckx RAJO, et al. Image quality and semiquantitative measurements on the biograph vision PET/CT system: initial experiences and comparison with the biograph mCT. J Nucl Med. 2020;61:129–35.CrossRef
8.
Zurück zum Zitat Seith F, Schmidt H, Kunz J, Küstner T, Gatidis S, Nikolaou K, et al. Simulation of tracer dose reduction in 18F-FDG PET/MRI: effects on oncologic reading, image quality, and artifacts. J Nucl Med. 2017;58:1699–705.CrossRef Seith F, Schmidt H, Kunz J, Küstner T, Gatidis S, Nikolaou K, et al. Simulation of tracer dose reduction in 18F-FDG PET/MRI: effects on oncologic reading, image quality, and artifacts. J Nucl Med. 2017;58:1699–705.CrossRef
9.
Zurück zum Zitat Linsen PV, Coenen A, Lubbers MM, Dijkshoorn ML, Ouhlous M, Nieman K. Computed tomography angiography with a 192-slice dual-source computed tomography system: improvements in image quality and radiation dose. J Clin Imaging Sci. 2016;6:44.CrossRef Linsen PV, Coenen A, Lubbers MM, Dijkshoorn ML, Ouhlous M, Nieman K. Computed tomography angiography with a 192-slice dual-source computed tomography system: improvements in image quality and radiation dose. J Clin Imaging Sci. 2016;6:44.CrossRef
10.
Zurück zum Zitat Båth M, Månsson LG. Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation. Br J Radiol. 2007;80:169–76.CrossRef Båth M, Månsson LG. Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation. Br J Radiol. 2007;80:169–76.CrossRef
11.
Zurück zum Zitat Phelps AS, Naeger DM, Courtier JL, Lambert JW, Marcovici PA, Villanueva-Meyer JE, et al. Pairwise comparison versus Likert scale for biomedical image assessment. AJR Am J Roentgenol. 2015;204:8–14.CrossRef Phelps AS, Naeger DM, Courtier JL, Lambert JW, Marcovici PA, Villanueva-Meyer JE, et al. Pairwise comparison versus Likert scale for biomedical image assessment. AJR Am J Roentgenol. 2015;204:8–14.CrossRef
12.
Zurück zum Zitat Fincham FD, Rogge R. Understanding relationship quality: theoretical challenges and new tools for assessment. J Fam Theory Rev. 2010;2:227–42.CrossRef Fincham FD, Rogge R. Understanding relationship quality: theoretical challenges and new tools for assessment. J Fam Theory Rev. 2010;2:227–42.CrossRef
13.
Zurück zum Zitat Vandenberghe R, Nelissen N, Salmon E, Ivanoiu A, Hasselbalch S, Andersen A, et al. Binary classification of 18F-flutemetamol PET using machine learning: comparison with visual reads and structural MRI. Neuroimage. 2013;64:517–25.CrossRef Vandenberghe R, Nelissen N, Salmon E, Ivanoiu A, Hasselbalch S, Andersen A, et al. Binary classification of 18F-flutemetamol PET using machine learning: comparison with visual reads and structural MRI. Neuroimage. 2013;64:517–25.CrossRef
14.
Zurück zum Zitat Sevigny J, Suhy J, Chiao P, Chen T, Klein G, Purcell D, et al. Amyloid PET screening for enrichment of early-stage Alzheimer disease clinical trials: experience in a phase 1b clinical trial. Alzheimer Dis Assoc Disord. 2016;30:1–7.CrossRef Sevigny J, Suhy J, Chiao P, Chen T, Klein G, Purcell D, et al. Amyloid PET screening for enrichment of early-stage Alzheimer disease clinical trials: experience in a phase 1b clinical trial. Alzheimer Dis Assoc Disord. 2016;30:1–7.CrossRef
15.
Zurück zum Zitat Ginj M, Zhang H, Waser B, Cescato R, Wild D, Wang X, et al. Radiolabeled somatostatin receptor antagonists are preferable to agonists for in vivo peptide receptor targeting of tumors. Proc Natl Acad Sci USA. 2006;103:16436–41.CrossRef Ginj M, Zhang H, Waser B, Cescato R, Wild D, Wang X, et al. Radiolabeled somatostatin receptor antagonists are preferable to agonists for in vivo peptide receptor targeting of tumors. Proc Natl Acad Sci USA. 2006;103:16436–41.CrossRef
16.
Zurück zum Zitat Nicolas GP, Beykan S, Bouterfa H, Kaufmann J, Bauman A, Lassmann M, et al. Safety, biodistribution, and radiation dosimetry of 68Ga-OPS202 in patients with gastroenteropancreatic neuroendocrine tumors: a prospective phase I imaging study. J Nucl Med. 2018;59:909–14.CrossRef Nicolas GP, Beykan S, Bouterfa H, Kaufmann J, Bauman A, Lassmann M, et al. Safety, biodistribution, and radiation dosimetry of 68Ga-OPS202 in patients with gastroenteropancreatic neuroendocrine tumors: a prospective phase I imaging study. J Nucl Med. 2018;59:909–14.CrossRef
17.
Zurück zum Zitat Nicolas GP, Schreiter N, Kaul F, Uiters J, Bouterfa H, Kaufmann J, et al. Sensitivity comparison of 68Ga-OPS202 and 68Ga-DOTATOC PET/CT in patients with gastroenteropancreatic neuroendocrine tumors: a prospective phase II imaging study. J Nucl Med. 2018;59:915–21.CrossRef Nicolas GP, Schreiter N, Kaul F, Uiters J, Bouterfa H, Kaufmann J, et al. Sensitivity comparison of 68Ga-OPS202 and 68Ga-DOTATOC PET/CT in patients with gastroenteropancreatic neuroendocrine tumors: a prospective phase II imaging study. J Nucl Med. 2018;59:915–21.CrossRef
18.
20.
Zurück zum Zitat Chauvie S, Bergesio F. The strategies to homogenize PET/CT metrics: the case of onco-haematological clinical trials. Biomedicines. 2016;4:26.CrossRef Chauvie S, Bergesio F. The strategies to homogenize PET/CT metrics: the case of onco-haematological clinical trials. Biomedicines. 2016;4:26.CrossRef
21.
Zurück zum Zitat Tugwell J, Everton C, Kingma A, Oomkens DM, Pereira GA, Pimentinha DB, et al. Increasing source to image distance for AP pelvis imaging: impact on radiation dose and image quality. Radiography. 2014;20:351–5.CrossRef Tugwell J, Everton C, Kingma A, Oomkens DM, Pereira GA, Pimentinha DB, et al. Increasing source to image distance for AP pelvis imaging: impact on radiation dose and image quality. Radiography. 2014;20:351–5.CrossRef
22.
Zurück zum Zitat Rosenkrantz AB, Kim S, Lim RP, Hindman N, Deng FM, Babb JS, et al. Prostate cancer localization using multiparametric MR imaging: comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert scales. Radiology. 2013;269:482–92.CrossRef Rosenkrantz AB, Kim S, Lim RP, Hindman N, Deng FM, Babb JS, et al. Prostate cancer localization using multiparametric MR imaging: comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert scales. Radiology. 2013;269:482–92.CrossRef
23.
Zurück zum Zitat Shamsi K, Patt RH. Onsite image evaluations and independent image blinded reads: close cousins or distant relatives? J Clin Oncol. 2009;27:2103–5.CrossRef Shamsi K, Patt RH. Onsite image evaluations and independent image blinded reads: close cousins or distant relatives? J Clin Oncol. 2009;27:2103–5.CrossRef
28.
Zurück zum Zitat Nicolas GP, Mansi R, McDougall L, Kaufmann J, Bouterfa H, Wild D, et al. Biodistribution, pharmacokinetics, and dosimetry of 177Lu-, 90Y-, and 111In-labeled somatostatin receptor antagonist OPS201 in comparison to the agonist 177Lu-DOTATATE: the mass effect. J Nucl Med. 2017;58:1435–41.CrossRef Nicolas GP, Mansi R, McDougall L, Kaufmann J, Bouterfa H, Wild D, et al. Biodistribution, pharmacokinetics, and dosimetry of 177Lu-, 90Y-, and 111In-labeled somatostatin receptor antagonist OPS201 in comparison to the agonist 177Lu-DOTATATE: the mass effect. J Nucl Med. 2017;58:1435–41.CrossRef
29.
Zurück zum Zitat Velikyan I, Sundin A, Eriksson B, Lundqvist H, Sörensen J, Bergström M, et al. In vivo binding of [68Ga]-DOTATOC to somatostatin receptors in neuroendocrine tumours–impact of peptide mass. Nucl Med Biol. 2010;37:265–75.CrossRef Velikyan I, Sundin A, Eriksson B, Lundqvist H, Sörensen J, Bergström M, et al. In vivo binding of [68Ga]-DOTATOC to somatostatin receptors in neuroendocrine tumours–impact of peptide mass. Nucl Med Biol. 2010;37:265–75.CrossRef
30.
Zurück zum Zitat Bozkurt MF, Virgolini I, Balogova S, Beheshti M, Rubello D, Decristoforo C, et al. Guideline for PET/CT imaging of neuroendocrine neoplasms with 68Ga-DOTA-conjugated somatostatin receptor targeting peptides and 18F-DOPA. Eur J Nucl Med Mol Imaging. 2017;44:1588–601.CrossRef Bozkurt MF, Virgolini I, Balogova S, Beheshti M, Rubello D, Decristoforo C, et al. Guideline for PET/CT imaging of neuroendocrine neoplasms with 68Ga-DOTA-conjugated somatostatin receptor targeting peptides and 18F-DOPA. Eur J Nucl Med Mol Imaging. 2017;44:1588–601.CrossRef
31.
Zurück zum Zitat Gaertner FC, Beer AJ, Souvatzoglou M, Eiber M, Fürst S, Ziegler SI, et al. Evaluation of feasibility and image quality of 68Ga-DOTATOC positron emission tomography/magnetic resonance in comparison with positron emission tomography/computed tomography in patients with neuroendocrine tumors. Invest Radiol. 2013;48:263–72.CrossRef Gaertner FC, Beer AJ, Souvatzoglou M, Eiber M, Fürst S, Ziegler SI, et al. Evaluation of feasibility and image quality of 68Ga-DOTATOC positron emission tomography/magnetic resonance in comparison with positron emission tomography/computed tomography in patients with neuroendocrine tumors. Invest Radiol. 2013;48:263–72.CrossRef
32.
Zurück zum Zitat Ilan E, Sandström M, Wassberg C, Sundin A, Garske-Román U, Eriksson B, et al. Dose response of pancreatic neuroendocrine tumors treated with peptide receptor radionuclide therapy using 177Lu-DOTATATE. J Nucl Med. 2015;56:177–82.CrossRef Ilan E, Sandström M, Wassberg C, Sundin A, Garske-Román U, Eriksson B, et al. Dose response of pancreatic neuroendocrine tumors treated with peptide receptor radionuclide therapy using 177Lu-DOTATATE. J Nucl Med. 2015;56:177–82.CrossRef
33.
Zurück zum Zitat Juweid ME, Stroobants S, Hoekstra OS, Mottaghy FM, Dietlein M, Guermazi A, et al. Use of positron emission tomography for response assessment of lymphoma: consensus of the Imaging Subcommittee of International Harmonization Project in Lymphoma. J Clin Oncol. 2007;25:571–8.CrossRef Juweid ME, Stroobants S, Hoekstra OS, Mottaghy FM, Dietlein M, Guermazi A, et al. Use of positron emission tomography for response assessment of lymphoma: consensus of the Imaging Subcommittee of International Harmonization Project in Lymphoma. J Clin Oncol. 2007;25:571–8.CrossRef
Metadaten
Titel
A novel read methodology to evaluate the optimal dose of 68Ga-satoreotide trizoxetan as a PET imaging agent in patients with gastroenteropancreatic neuroendocrine tumours: a phase II clinical trial
verfasst von
Colin G. Miller
Henning Grønbæk
Irene Virgolini
Andreas Kjaer
Pierre Terve
Shadfar Bahri
Peter Iversen
Hanna Svirydenka
Thomas Rohban
Sandy McEwan
Publikationsdatum
01.12.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
EJNMMI Research / Ausgabe 1/2021
Elektronische ISSN: 2191-219X
DOI
https://doi.org/10.1186/s13550-021-00819-1

Weitere Artikel der Ausgabe 1/2021

EJNMMI Research 1/2021 Zur Ausgabe