Skip to main content
Erschienen in: BMC Surgery 1/2018

Open Access 01.12.2018 | Study protocol

A post-market, prospective, multi-center, single-arm clinical investigation of Phasix™ mesh for VHWG grade 3 midline incisional hernia repair: a research protocol

verfasst von: M. M. J. van Rooijen, A. P. Jairam, T. Tollens, L. N. Jørgensen, T. S. de Vries Reilingh, G. Piessen, F. Köckerling, M. Miserez, A. C. J. Windsor, F. Berrevoet, R. H. Fortelny, B. Dousset, G. Woeste, H. L. van Westreenen, F. Gossetti, J. F. Lange, G. W. M. Tetteroo, A. Koch, L. F. Kroese, J. Jeekel

Erschienen in: BMC Surgery | Ausgabe 1/2018

Abstract

Background

Incisional heia is a frequent complication of midline laparotomy. The use of mesh in hernia repair has been reported to lead to fewer recurrences compared to primary repair. However, in Ventral Hernia Working Group (VHWG) Grade 3 hernia patients, whose hernia is potentially contaminated, synthetic mesh is prone to infection. There is a strong preference for resorbable biological mesh in contaminated fields, since it is more able to resist infection, and because it is fully resorbed, the chance of a foreign body reaction is reduced. However, when not crosslinked, biological resorbable mesh products tend to degrade too quickly to facilitate native cellular ingrowth. Phasix™ Mesh is a biosynthetic mesh with both the biocompatibility and resorbability of a biological mesh and the mechanical strength of a synthetic mesh. This multi-center single-arm study aims to collect data on safety and performance of Phasix™ Mesh in Grade 3 hernia patients.

Methods

A total of 85 VHWG Grade 3 hernia patients will be treated with Phasix™ Mesh in 15 sites across Europe. The primary outcome is Surgical Site Occurrence (SSO) including hematoma, seroma, infection, dehiscence and fistula formation (requiring intervention) through 3 months. Secondary outcomes include recurrence, infection and quality of life related outcomes after 24 months. Follow-up visits will be at drain removal (if drains were not placed, then on discharge or staple removal instead) and in the 1st, 3rd, 6th, 12th, 18th and 24th month after surgery.

Conclusion

Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients.

Trial registration

The trial was registered on March 25, 2016 on clinicaltrials.gov: NCT02720042.
Hinweise
M. M. J. van Rooijen and A. P. Jairam contributed equally to this work.
Abkürzungen
ADE
Adverse Device Effect
AE
Adverse Event
BMI
Body Mass Index
CCS
Carolina Comfort Scale
CST
Component Separation Technique
CT
Computed Tomography Scan
EQ-5D
EuroQol-5D
HIV
Human Immunodeficiency Virus
IH
Incisional Hernia
LOS
Length of hospital Stay
mITT
Modified Intention-to-treat
MRI
Magnetic Resonance Imaging
PP
Per Protocol
SAE
Serious Adverse Event
SSI
Surgical Site Infection
SSO
Surgical Site Occurence
Trademark
VAS
Visual Analogue Scale
VHWG
Ventral Hernia Working Group

Background

Incisional hernia (IH) is one of the most frequent complications after midline laparotomy, with incidences varying from 10 to 20%, and even higher percentages occur in high-risk groups [1, 2]. IH can lead to a high morbidity and reduces quality of life [3, 4]. Due to the high IH incidence rates, hernia repair surgery is one of the most frequently performed surgical procedures [5]. The aim of hernia surgery is to relieve symptoms, to prevent complications or to resolve acute complications.
There are several options for hernia repair, including primary simple suture repair, synthetic or biologic material placement, repair with relaxing incisions, component separation and use of musculofascial flaps, utilizing both open and laparoscopic approaches [68]. Synthetic mesh repair procedures, either open or laparoscopic, lead to fewer recurrences compared to primary repair; recurrences after mesh are 7.7% compared to 23.8% after primary closure [1, 3, 9, 10]. Improved outcomes are believed to be related to reduced tension on the fascial edges and sutures when mesh is used in hernia repair procedures. Despite reducing hernia recurrence rates, the use of synthetic mesh has been associated with complications in approximately 17% of patients. These complications include infection, pain, adhesions, fistulae and foreign body reactions including increased inflammation and/or connective tissue deposition [3, 11]. Especially complex and large abdominal wall defects continue to pose a challenge to surgeons, which are associated with recurrence rates of up to nearly 40% [12].
It can be stated that synthetic mesh is more prone to infection than primary closure, and this poses a problem in potentially contaminated hernias like Ventral Hernia Working Group (VHWG) Grade 3 hernias [13] (Fig. 1). The success of the mesh repair is jeopardized by potential contamination due to complicating factors like previous wound infection, the presence of a stoma or violation of the gastro-intestinal tract.
The use of a biological tissue matrix has been advocated in (potentially) contaminated hernias, because of their ability to resist infection, milder inflammatory response and more orderly collagen deposition than non-resorbable, synthetic meshes [1416]. Most often, biological meshes are derived from human, porcine or bovine dermis, and these materials have been processed to acellular sheets of collagen and elastin. The development of resorbable mesh products has faced challenges related to the rate of absorption with complications arising when the mesh product is resorbed too quickly. Rapid resorption does not support sufficient healing if structural reinforcement is diminished during the tissue repair period.
Therefore, some meshes contain chemicals to induce additional crosslinking in the graft. This slows down the degradation process, causing the mesh to retain its strength for a longer period of time [17]. However, crosslinking in the mesh reduces its biocompatibility; causing delayed cellular infiltration and neovascularization [1719]. Ideally, a resorbable mesh should have a high ability to resist infections and retain its functional strength for a sufficient period of time to allow native cellular ingrowth tissue remodeling, maturation of collagen and gradual shift of mechanical load.
Phasix™ Mesh is a commercially available biosynthetic mesh. It is a slowly resorbable mesh prepared from poly-4-hydroxybutrate which has been studied for use as a biomaterial for different medical applications due its strength and flexibility, biocompatibility and desirable degradation times [2022]. Phasix™ Mesh is comparable in performance to traditional polypropylene mesh when using standard measures of mechanical strength (suture pullout, tear and ball burst strength) [23, 24]. Preclinical implantation studies indicate that Phasix™ Mesh retains approximately 70% of its original strength at 12 weeks [23]. Absorption of the mesh material will be essentially complete in 12–18 months [24]. Given the long-term strength retention observed in preclinical studies, it is anticipated that Phasix™ Mesh may result in low recurrence and complication rates with minimal pain and discomfort when used for hernia repair.

Rationale

From a general perspective, the current literature still is rather void of evidence-based guidelines regarding optimal choice of mesh. Simple, uncontaminated hernias are usually treated with synthetic mesh; biologic meshes are mostly used in potentially contaminated hernias, since post-operative mesh infection is anticipated.
Until now, the use of Phasix™ Mesh was studied primarily in patients up to VHWG Grade 2 [25].
Phasix™ Mesh has been studied prospectively until now in patients with a clean hernia site (CDC class I [26]) and up to VHWG Grade 2 [25, 27, 28]. A small retrospective study has also been conducted, showing positive results, but not elaborating on the exact contamination or size of the hernias [29]. Based on the data that will be gained from this clinical study, additional evidence may be provided with a view to optimal selection of hernia repair material in a population of higher risk. Since there is only limited knowledge on the treatment of VHWG Grade 3 patients, additional information is needed on safety and performance of the Phasix™ Mesh. Based on the combination of the features of the Phasix™ Mesh proven in previous clinical and non-clinical investigations, and based on evidence from the clinical study as described in this protocol, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients.

Methods

Objectives

The objective of this study is to collect additional data on safety and performance of Phasix™ Mesh in subjects requiring VHWG Grade 3 midline incisional hernia repair. Among others, Surgical Site Occurrence (SSO), hernia recurrence, pain, infection, reoperation and adverse events will be collected for subjects with a VHWG Grade 3 hernia meeting the study inclusion and exclusion criteria.

Design

The study has been designed as a post-market, prospective, single arm, multi-center, open-label study to collect data on performance and safety of Phasix™ Mesh in subjects with a VHWG Grade 3 midline hernia. This study will be conducted in 15 hospitals across Europe, which will each be allowed to include a maximum of 15 patients.

Participants

Subjects with a VHWG Grade 3 incisional hernia scheduled for hernia repair are eligible for this study and will be asked for informed consent at the outpatient clinic. VHWG Grade 3 included, among others, previous wound infection after previous laparotomy (verified in the patient’s medical record), small bowel resection with anastomosis, take down of ileostomy with ileocolonic anastomosis, creation of a stoma, stoma present, jejunostomy, gastrectomy, and cholecystectomy. Patients with active infections, infected mesh, abscesses or active fistulas were not considered among patients with VHWG Grade 3. Patients solely at risk for an incidental enterotomy were not included in the population of which subjects could be drawn from.

Inclusion criteria

All subjects who meet the following criteria listed below can be enrolled in the study:
  • Age 18 years or older
  • Diagnosis of an incisional midline hernia
  • VHWG Grade 3 hernia
  • Size of hernia > 10 cm2, as measured intraoperatively
  • Elective retro-rectus hernia repair
  • Signed informed consent

Exclusion criteria

All subjects who meet the following criteria must be excluded from study enrolment:
Regarding the subject:
  • Body Mass Index (BMI) > 35 kg/m2
  • Peritonitis
  • Use or suspected future use of chemotherapeutic medication during any part of the study
  • Known human immunodeficiency virus (HIV) infection
  • Cirrhosis of the liver and/or ascites
  • Pregnancy, plans to become pregnant during the study period or current breastfeeding
  • Alcohol/substance abuse problem or a relapse within 12 months of the screening visit
  • Involvement in another interventional clinical study in the last 30 days prior to informed consent signature
  • Life expectancy of less than 2 years at the time of enrollment
  • Known sensitivity to Phasix™ Mesh or component materials (subjects with known allergies to tetracycline hydrochloride or kanamycin sulfate)
  • Any condition that, in the opinion of the investigator, would preclude the use of the study device or preclude the subject from completing the follow-up requirements
Regarding ventral hernia:
  • More than 4 previous repairs of the hernia under observation
  • The hernia repair requires more than a single piece of mesh
  • Intact permanent mesh adjacent to the current hernia to be repaired
Regarding surgery:
  • American Society of Anesthesiology class 4 or 5
  • Surgical technique requires surgical bridge repair
  • Complete removal of existing mesh from a prior hernia repair (in the same affected area) is not possible
  • The hernia repair requires intraabdominal mesh placement

Study procedures

Screening

Subjects with a diagnosis of incisional midline hernia requiring surgical repair to close the defect who are presenting at the study site will be considered potential subjects for inclusion in this clinical study and should be pre-screened for study eligibility. If inclusion criteria are potentially met and no exclusion criteria are anticipated to be present at the time of pre-screening, the Investigator will invite the subject to participate in the study.
Subjects will be asked to sign a written informed consent form. A copy of the informed consent will be provided to the subject.

Eligibility

Final eligibility will be determined intraoperatively. Subjects who fail to meet eligibility criteria should be considered screen failures and will be treated per hospital standard of care. Reason for screen failure will be documented. Screen failures are not considered drop-outs, and hospitals will continue to include patients until the required sample size has received surgery.

Intervention

All subjects will undergo an open ventral repair of the hernia. All intraoperative inclusion and exclusion criteria will be verified.
Subjects will be administered perioperative antibiotics according to hospital protocol. Subjects will be prepared to undergo hernia repair with Phasix™ Mesh. The general instructions for the use of Phasix™ Mesh are supplied by the manufacturer.

Surgical technique

The surgical technique will require retro-rectus placement (onlay is allowed as an exception when retro-rectus placement cannot be achieved), using slowly resorbable sutures, with or without Component Separation Technique (CST). The peritoneum should remain posterior to the mesh upon completion of mesh placement. The mesh may be cut to shape or size desired for each specific application. The mesh is to be positioned so its edges extend beyond the margins of the defect by at least 5 cm. It is recommended that the mesh is fixated at approximately 5–6 cm intervals (6–12 absorbable sutures) around the periphery of the mesh. Defect closure must be confirmed. All skin incisions will be closed with staples/sutures and wounds will be dressed with sterile occlusive dressings.

Outcome parameters

Primary outcome

Primary outcome will be Surgical Site Occurrence (SSO) up to and including, the 3-month follow-up assessment. SSOs will be assessed by physical examination at each study visit through 3 months. SSO is defined as hematoma, seroma, surgical site infection, wound dehiscence, skin necrosis and fistula, all of which require intervention.

Secondary outcome

Secondary outcomes will be:
  • Surgical Site Occurrence (SSO) after the 3-month follow-up assessment
  • Surgical Site Infection (SSI) [26], is included in SSOs, but will also be analysed separately
  • Hernia Recurrence rate (via physical exam, if uncertain via ultrasonography, CT or MRI)
  • Pain at every follow-up point, measured with the Visual Analogue Scale (VAS)
  • Device related adverse event incidence
  • Rate of reoperation due to the index hernia repair
  • Quality of Life assessments (Carolinas Comfort Scale™ [30]1 and EuroQol-5D (EQ-5D) [31])
  • Surgical procedure time as measured from incision to closure (skin to skin)
  • Return to work
  • Length of hospital stay (day of index surgery until day of discharge, LOS)
To measure these outcomes, the following data will be gathered at different points in time, and saved in an electronic case report form:

Pre-operative data

  • Demographic data (age, sex, race, ethnicity) and medical history
  • Information regarding the inclusion and exclusion criteria
  • Height and weight (calculated to a BMI)
  • Length and width of hernia
  • Wound assessment
    ○ signs of infection
    ○ status and location of potential previous mesh
    ○ signs of necrosis
  • Pain medication usage
  • Pain (measured with VAS), discomfort (measured with Carolinas Comfort Scale™) and quality of life (measured with EQ-5D)

Peri-operative data

  • Information regarding the inclusion and exclusion criteria
  • Intra-operative evaluation of wound and abdomen
  • Intra-operative assessment and description of hernia
  • Intra-operative assessment of complications, e.g. enterotomy
  • Surgical procedure
  • Mesh details
  • Fixation details
  • Wound closure

Post-operative data

The following data will be collected at fixed follow-up visits, namely at drain removal (if applicable, otherwise at discharge or at staple removal), 1 month, 3 months, 6 months, 12 months, 18 months and 24 months (Table 1):
  • Wound assessment
    ○ signs of infection
    ○ status and location of potential previous mesh
    ○ signs of necrosis
  • Hernia recurrence (diagnosed with physical exam, if uncertain via ultrasonography, or via CT/MRI)
  • Adverse events
  • Device failure/malfunction/defects
  • Pain (measured with VAS)
  • Discomfort (measured with Carolinas Comfort Scale™)
  • Quality of life (measured with EQ-5D)
Table 1
Summary of procedures performed per visit
Study procedure
Screening and baseline
Index surgery
Drain removal/discharge
1, 3, 6 and 18 Month Visit
12 and 24 Month Visit
Early term
Describe study to potential subject
X
     
Obtain informed consent
X
     
Collect demographics and medical history
X
     
Verify eligibility criteria
X
X
    
Physical examination
X
 
X
X
X
X
Placement of device
 
X
    
Pain Scale (VAS)
X
 
X
X
X
X
Carolinas Comfort Scale™
X
  
X
X
X
EQ-5D
X
  
X
X
X
Collect Adverse Events
 
X
X
X
X
X
Collect pain medications
X
   
X
 
In addition, pain medication usage will be collected at 12 and 24 months follow-up.

Withdrawal/early termination

A subject is considered an Early Termination if discontinuation occurs after study treatment and before 24 months follow-up. The site will attempt to bring the subject back to the hospital to complete all Early Termination visit study procedures: Physical examination, Pain measured with VAS, Carolinas Comfort Scale™, EQ-5D and collect adverse events. Reason for subject discontinuation will be documented when possible.

Sample size consideration

The expected rate of SSO at 3 months is 37% based on historical data (ranging from 21 to 53%) [3235]. With 75 subjects, the accuracy of the estimated SSO will be ±11% (i.e. half of the width of the 95% confidence interval of the estimated rate of SSO is 11%). The study plans to enroll 85 subjects for follow-up. Anticipating on an attrition rate of about 10% after surgery, 75 subjects will be evaluable to assess the primary endpoint of Surgical Site Occurrence (SSO) at 3 months.

Statistical analysis

There will be a modified intention-to-treat population (mITT), which consists of the subjects in whom Phasix™ Mesh has been implanted. The screen failures were not implanted, and therefore not used in the analysis. A per-protocol (PP) population may be created if there are subjects who have any major protocol deviations. However, all analyses will be primarily based on the mITT population.
Demographics and baseline characteristics will be summarized using the mITT population. Summary statistics for categorical variables will include frequency counts and percentages, and for continuous variables mean, standard deviation, minimum, median and maximum.
The primary endpoint is the SSO rate up to (including) 3 months (± 14 days) post device placement based on the mITT population. A 95% confidence interval will be reported for the SSO rate.
The SSO rate after 3 months, the hernia recurrence rates and surgical site infection rates until 1, 3, 6, 12, 18 and 24 months post device placement will be reported per visit along with their 95% confidence intervals based on the mITT population as secondary endpoints. Additionally, Kaplan-Meier analyses for the time from surgery to hernia recurrence and for the time from surgery to surgical site infection may be performed.
The secondary endpoints of VAS pain scale, Carolinas Comfort Scale™ and EQ-5D will be summarized based on the mITT population with mean, standard deviation, minimum, median and maximum presented by visit.
Device related adverse events will be tabulated by system organ class and preferred term. The number of subjects with a post procedure reoperation due to the index hernia repair will be presented by time intervals (until 1, 3, 6, 12, 18 and 24 months post device placement), surgical procedure duration of the index procedure (calculated as time of skin closure complete minus time of first incision) and length of hospital stay will be summarized descriptively. The time to return to work will be tabulated using summary statistics as well.
Safety parameters, such as adverse events, device deficiencies (mechanical failure, malfunction or defects), physical examination and pain medication, will be summarized using the mITT population.
Subgroup analyses will be performed by sex, sites (sites with few treated subjects can be combined) and other factors of interest.
No missing value imputation methods will be applied in any of the aforementioned analyses.

Safety

In this study, Adverse Events (AE) are defined as any undesirable clinical event occurring in the abdominal wall or the abdominal space, as well as any other undesirable clinical events judged to be related to the study device or surgical procedure regardless of anatomical region, from time of implantation to end of study participation. Abnormal laboratory results are also to be considered as AEs if the results are accompanied by clinical signs or symptoms. The investigator will assess the relationship of an AE to the study device or procedure and categorize them as ‘definitely’, ‘possibly’ or ‘not related’.
An adverse device effect (ADE) is an AE related to the use of the mesh product implanted (e.g. insufficient or inadequate implantation, installation, operation or malfunction of the Phasix™ Mesh).
Serious adverse events (SAE) are the events that meet the definition of serious in the ISO 14155:2011.
All events will be followed to satisfactory resolution or stabilization.
The investigator is responsible for the detection and documentation of events meeting the criteria and definition of AE, ADE or SAE. All SAEs and investigator-judged device related AEs that occur, must be reported to the sponsor within 24 h of becoming aware of the event.
An independent safety monitoring committee will reassess safety of the study protocol and decide about potential adaptations if one of the following criteria are met:
  • More than 4 device related SAEs within 3 months of Phasix™ Mesh implantation
  • More than 1 device related recurrence within 3 months of Phasix™ Mesh implantation
The enrolment and treatment of new subjects are suspended until the impact of the study parameters (e.g. surgical technique, hernia size, mesh size, AE time-course) on the results is assessed. The follow-up for the subjects already treated continues.
Monitoring for accuracy and timely submission of data forms and compliance with the study protocol, meeting enrolment commitments and applicable regulations will take place by monitoring personnel.

Ethics

This study will be conducted in accordance with the principles of the Declaration of Helsinki and Good Clinical Practice guidelines. The Medical Ethical Committee of the Erasmus Medical Center and the Institutional Review Board of every participating hospital have approved the protocol. Written informed consent will be obtained from all subjects. All study data will be recorded in electronic Case Report Forms provided to the investigational site. Site and subject numbers will be used to track subject information throughout the study.
The sponsor of the study has taken out an insurance policy for all participants of the study, in the case of any negative consequences experienced due to the study or the medical device.
The results of the study will be published, regardless of the outcome, either favourable or unfavourable, in a peer-reviewed journal and on clinicaltrials.​gov, which is accessible for the public.

Discussion

A major challenge in all hernia studies is the formulation of a clear definition on the severity or grade of the hernia. The difference between grade 3 and 4 hernias is not always clear, since the classification is more gradual than it seems. The definition for Grade 3 hernias used in this study is the same as the one of the Ventral Hernia Working Group in 2010, which excludes presence of infected mesh [13].
A discussion topic in this study is the absence of a control group. No standard treatment is registered for VHWG Grade 3 hernias. The standard treatment per hospital as a control group would not suffice, because 15 hospitals in Europe participate; this would have led to very heterogeneously treated control group with very heterogeneous results, insufficiently valid to compare to the performance of Phasix™ Mesh. Suture closure was considered as a control group, but this would have been disadvantageous for the patient because this has been proven to lead to more recurrences [1]. Also non-absorbable synthetic mesh was considered as a control group, because synthetic mesh placement reduces recurrences compared to suture closure or closure with the aid of biological mesh [36, 37]. However, synthetic mesh has been hypothesized to lead to a high infection rate due to the potential contamination present in VHWG Grade 3 hernia patients [38, 39]. Thirdly, the comparison with biological mesh is also hypothesized to be contra-indicated. Biological mesh has a high salvage rate when infected [40, 41], but has a higher recurrence rate than repair with synthetic mesh [37].
Because no standard treatment is recorded for VHWG Grade 3 hernias, comparing Phasix™ Mesh with synthetic mesh has been considered to be unethical, since the potential contamination of the hernia could cause complications when using a synthetic mesh. Comparing Phasix™ Mesh with just sutures (primary closure) would not be ethical either, due to the high recurrence rates associated with primary closure.
It was considered to compare Phasix™ Mesh with the treating surgeon’s standard of care for VHWG Grade 3 hernias in each participating hospital. However, due to the lack of consensus on what standard of care for VHWG Grade 3 hernias is, this would lead to a very heterogenous control group. This justifies the single-arm design of the study. Therefore, no randomization or blinding has been applied, leading to a possible higher risk of bias. If this study yields positive results, a large randomized controlled trial would be the next step in the exploration of Phasix™ Mesh augmentation in VHWG Grade 3 patients.
Due to the extensive inclusion- and exclusion criteria used in this study, and the specific goal of assessing safety and performance, the expected generalizability will be limited. VHWG Grade 3 patients are very specific patients with a high risk of developing an SSO. However, a study has shown that patients with only a history of infection after previous laparotomy without the other factors determining VHWG Grade 3, have a lower risk of developing an SSO. Therefore, it suggests a modified VHWG Grade 3 scale. It would be useful to analyse the results of the study described in this protocol between patients with only a previous infection after a previous laparotomy, and patients with one or more of the other factors determining VHWG Grade 3. Stratification for other confounders or effect modifiers, such as the presence of a stoma or the CDC wound classification could be of interest as well.
Surgeon skill is known to be an important predictor in surgical outcomes. Even though 15 different hospitals with 16 different surgeons participated, all surgeons have more than 10 years of experience in hernia surgery.

Conclusion

This multicenter trial will collect additional data on safety and performance of Phasix™ Mesh in subjects with a VHWG Grade 3 midline hernia requiring surgical repair. Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients.

Acknowledgements

Not applicable.

Funding

C. R. Bard (the sponsor) has designed and financially supported this trial, and will as well conduct interim analyses on the collected data.

Availability of data and materials

This is a protocol, therefore no collected patient data was used. Not applicable.
This study will be conducted in accordance with the principles of the Declaration of Helsinki and Good Clinical Practice guidelines. The Medical Ethical Committee of the Erasmus Medical Center and the Institutional Review Board of every participating hospital have approved the protocol. Written informed consent will be obtained from all subjects. A model consent form will be available upon reasonable request. All study data will be recorded in electronic Case Report Forms provided to the investigational site. Site and subject numbers will be used to track subject information throughout the study.
Not applicable.

Competing interests

The study was funded and reviewed by C. R. Bard. (the sponsor).

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Fußnoten
1
The CAROLINAS COMFORT SCALE™ questionnaire was created by and is licensed from the Division of Gastrointestinal and Minimally Invasive Surgery of Carolinas Medical Center, North Carolina
 
Literatur
1.
Zurück zum Zitat Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, JN IJ, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC, et al. A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med. 2000;343(6):392–8.CrossRef Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, JN IJ, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC, et al. A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med. 2000;343(6):392–8.CrossRef
2.
Zurück zum Zitat Hoer J, Lawong G, Klinge U, Schumpelick V. Factors influencing the development of incisional hernia. A retrospective study of 2,983 laparotomy patients over a period of 10 years. Chirurg. 2002;73(5):474–80.CrossRef Hoer J, Lawong G, Klinge U, Schumpelick V. Factors influencing the development of incisional hernia. A retrospective study of 2,983 laparotomy patients over a period of 10 years. Chirurg. 2002;73(5):474–80.CrossRef
3.
Zurück zum Zitat Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J. Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg. 2004;240(4):578–83 discussion 583-575.PubMedPubMedCentral Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J. Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg. 2004;240(4):578–83 discussion 583-575.PubMedPubMedCentral
4.
Zurück zum Zitat van Ramshorst GH, Eker HH, Hop WC, Jeekel J, Lange JF. Impact of incisional hernia on health-related quality of life and body image: a prospective cohort study. Am J Surg. 2012;204(2):144–50.CrossRef van Ramshorst GH, Eker HH, Hop WC, Jeekel J, Lange JF. Impact of incisional hernia on health-related quality of life and body image: a prospective cohort study. Am J Surg. 2012;204(2):144–50.CrossRef
5.
Zurück zum Zitat Sauerland S, Walgenbach M, Habermalz B, Seiler CM, Miserez M: Laparoscopic versus open surgical techniques for ventral or incisional hernia repair. In: Cochrane Database of Systematic Reviews. John Wiley & Sons, Ltd; 2011. Sauerland S, Walgenbach M, Habermalz B, Seiler CM, Miserez M: Laparoscopic versus open surgical techniques for ventral or incisional hernia repair. In: Cochrane Database of Systematic Reviews. John Wiley & Sons, Ltd; 2011.
6.
Zurück zum Zitat van Geffen HJ, Simmermacher RK, van Vroonhoven TJ, van der Werken C. Surgical treatment of large contaminated abdominal wall defects. J Am Coll Surg. 2005;201(2):206–12.CrossRef van Geffen HJ, Simmermacher RK, van Vroonhoven TJ, van der Werken C. Surgical treatment of large contaminated abdominal wall defects. J Am Coll Surg. 2005;201(2):206–12.CrossRef
7.
Zurück zum Zitat Ramirez OM, Ruas E, Dellon AL. "components separation" method for closure of abdominal-wall defects: an anatomic and clinical study. Plast Reconstr Surg. 1990;86(3):519–26.CrossRef Ramirez OM, Ruas E, Dellon AL. "components separation" method for closure of abdominal-wall defects: an anatomic and clinical study. Plast Reconstr Surg. 1990;86(3):519–26.CrossRef
8.
Zurück zum Zitat DiBello JN, Jr., Moore JH, Jr.: Sliding myofascial flap of the rectus abdominus muscles for the closure of recurrent ventral hernias. Plast Reconstr Surg 1996, 98(3):464–469.CrossRef DiBello JN, Jr., Moore JH, Jr.: Sliding myofascial flap of the rectus abdominus muscles for the closure of recurrent ventral hernias. Plast Reconstr Surg 1996, 98(3):464–469.CrossRef
9.
Zurück zum Zitat Mathes T, Walgenbach M, Siegel R. Suture versus mesh repair in primary and incisional ventral hernias: a systematic review and meta-analysis. World J Surg. 2016;40(4):826–35.CrossRef Mathes T, Walgenbach M, Siegel R. Suture versus mesh repair in primary and incisional ventral hernias: a systematic review and meta-analysis. World J Surg. 2016;40(4):826–35.CrossRef
10.
Zurück zum Zitat Cobb WS, Kercher KW, Heniford BT. Laparoscopic repair of incisional hernias. Surg Clin North Am. 2005;85(1):91–103 ix.CrossRef Cobb WS, Kercher KW, Heniford BT. Laparoscopic repair of incisional hernias. Surg Clin North Am. 2005;85(1):91–103 ix.CrossRef
11.
Zurück zum Zitat Markar SR, Karthikesalingam A, Alam F, Tang TY, Walsh SR, Sadat U. Partially or completely absorbable versus nonabsorbable mesh repair for inguinal hernia: a systematic review and meta-analysis. Surg Laparosc Endosc Percutan Tech. 2010;20(4):213–9.CrossRef Markar SR, Karthikesalingam A, Alam F, Tang TY, Walsh SR, Sadat U. Partially or completely absorbable versus nonabsorbable mesh repair for inguinal hernia: a systematic review and meta-analysis. Surg Laparosc Endosc Percutan Tech. 2010;20(4):213–9.CrossRef
12.
Zurück zum Zitat Slater NJ, van Goor H, Bleichrodt RP. Large and complex ventral hernia repair using "components separation technique" without mesh results in a high recurrence rate. Am J Surg. 2015;209(1):170–9.CrossRef Slater NJ, van Goor H, Bleichrodt RP. Large and complex ventral hernia repair using "components separation technique" without mesh results in a high recurrence rate. Am J Surg. 2015;209(1):170–9.CrossRef
13.
Zurück zum Zitat Ventral Hernia Working Group, Breuing K, Butler CE, Ferzoco S, Franz M, Hultman CS, Kilbridge JF, Rosen M, Silverman RP, Vargo D. Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair. Surgery. 2010;148(3):544–58.CrossRef Ventral Hernia Working Group, Breuing K, Butler CE, Ferzoco S, Franz M, Hultman CS, Kilbridge JF, Rosen M, Silverman RP, Vargo D. Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair. Surgery. 2010;148(3):544–58.CrossRef
14.
Zurück zum Zitat Zheng F, Lin Y, Verbeken E, Claerhout F, Fastrez M, De Ridder D, Deprest J. Host response after reconstruction of abdominal wall defects with porcine dermal collagen in a rat model. Am J Obstet Gynecol. 2004;191(6):1961–70.CrossRef Zheng F, Lin Y, Verbeken E, Claerhout F, Fastrez M, De Ridder D, Deprest J. Host response after reconstruction of abdominal wall defects with porcine dermal collagen in a rat model. Am J Obstet Gynecol. 2004;191(6):1961–70.CrossRef
15.
Zurück zum Zitat Kissane NA, Itani KM. A decade of ventral incisional hernia repairs with biologic acellular dermal matrix: what have we learned? Plast Reconstr Surg. 2012;130(5 Suppl 2):194S–202S.CrossRef Kissane NA, Itani KM. A decade of ventral incisional hernia repairs with biologic acellular dermal matrix: what have we learned? Plast Reconstr Surg. 2012;130(5 Suppl 2):194S–202S.CrossRef
16.
Zurück zum Zitat Itani KM, Rosen M, Vargo D, Awad SS, Denoto G 3rd, Butler CE, Group RS. Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH study. Surgery. 2012;152(3):498–505.CrossRef Itani KM, Rosen M, Vargo D, Awad SS, Denoto G 3rd, Butler CE, Group RS. Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH study. Surgery. 2012;152(3):498–505.CrossRef
17.
Zurück zum Zitat Liang HC, Chang Y, Hsu CK, Lee MH, Sung HW. Effects of crosslinking degree of an acellular biological tissue on its tissue regeneration pattern. Biomaterials. 2004;25(17):3541–52.CrossRef Liang HC, Chang Y, Hsu CK, Lee MH, Sung HW. Effects of crosslinking degree of an acellular biological tissue on its tissue regeneration pattern. Biomaterials. 2004;25(17):3541–52.CrossRef
18.
Zurück zum Zitat Melman L, Jenkins ED, Hamilton NA, Bender LC, Brodt MD, Deeken CR, Greco SC, Frisella MM, Matthews BD. Early biocompatibility of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral hernia repair. Hernia. 2011;15(2):157–64.CrossRef Melman L, Jenkins ED, Hamilton NA, Bender LC, Brodt MD, Deeken CR, Greco SC, Frisella MM, Matthews BD. Early biocompatibility of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral hernia repair. Hernia. 2011;15(2):157–64.CrossRef
19.
Zurück zum Zitat Deeken CR, Melman L, Jenkins ED, Greco SC, Frisella MM, Matthews BD. Histologic and biomechanical evaluation of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral incisional hernia repair. J Am Coll Surg. 2011;212(5):880–8.CrossRef Deeken CR, Melman L, Jenkins ED, Greco SC, Frisella MM, Matthews BD. Histologic and biomechanical evaluation of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral incisional hernia repair. J Am Coll Surg. 2011;212(5):880–8.CrossRef
20.
Zurück zum Zitat Wu Q, Wang Y, Chen G-Q. Medical application of microbial biopolyesters Polyhydroxyalkanoates. Artif Cells Blood Substit Immobil Biotechnol. 2009;37(1):1–12.CrossRef Wu Q, Wang Y, Chen G-Q. Medical application of microbial biopolyesters Polyhydroxyalkanoates. Artif Cells Blood Substit Immobil Biotechnol. 2009;37(1):1–12.CrossRef
21.
Zurück zum Zitat Martin DP, Williams SF. Medical applications of poly-4-hydroxybutyrate: a strong flexible absorbable biomaterial. Biochem Eng J. 2003;16(2):97–105.CrossRef Martin DP, Williams SF. Medical applications of poly-4-hydroxybutyrate: a strong flexible absorbable biomaterial. Biochem Eng J. 2003;16(2):97–105.CrossRef
22.
Zurück zum Zitat Chen G-Q, Wu Q. The application of polyhydroxyalkanoates as tissue engineering materials. Biomaterials. 2005;26(33):6565–78.CrossRef Chen G-Q, Wu Q. The application of polyhydroxyalkanoates as tissue engineering materials. Biomaterials. 2005;26(33):6565–78.CrossRef
23.
Zurück zum Zitat Martin DP, Badhwar A, Shah DV, Rizk S, Eldridge SN, Gagne DH, Ganatra A, Darois RE, Williams SF, Tai HC, et al. Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications. J Surg Res. 2013;184(2):766–73.CrossRef Martin DP, Badhwar A, Shah DV, Rizk S, Eldridge SN, Gagne DH, Ganatra A, Darois RE, Williams SF, Tai HC, et al. Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications. J Surg Res. 2013;184(2):766–73.CrossRef
24.
Zurück zum Zitat Deeken CR, Matthews BD. Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (Poly-4-hydroxybutyrate-PHASIX mesh) in a porcine model of hernia repair. ISRN Surg. 2013;2013:238067.CrossRef Deeken CR, Matthews BD. Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (Poly-4-hydroxybutyrate-PHASIX mesh) in a porcine model of hernia repair. ISRN Surg. 2013;2013:238067.CrossRef
27.
Zurück zum Zitat Roth JS, Anthone GJ, Selzer DJ, Poulose BK, Bittner JG, Hope WW, Dunn RM, Martindale RG, Goldblatt MI, Earle DB, et al. Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up. Surg Endosc. 2018;32(4):1929–36.CrossRef Roth JS, Anthone GJ, Selzer DJ, Poulose BK, Bittner JG, Hope WW, Dunn RM, Martindale RG, Goldblatt MI, Earle DB, et al. Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up. Surg Endosc. 2018;32(4):1929–36.CrossRef
28.
Zurück zum Zitat Plymale MA, Davenport DL, Dugan A, Zachem A, Roth JS. Ventral hernia repair with poly-4-hydroxybutyrate mesh. Surg Endosc. 2018;32(4):1689–94.CrossRef Plymale MA, Davenport DL, Dugan A, Zachem A, Roth JS. Ventral hernia repair with poly-4-hydroxybutyrate mesh. Surg Endosc. 2018;32(4):1689–94.CrossRef
29.
Zurück zum Zitat Buell JF, Sigmon D, Ducoin C, Shapiro M, Teja N, Wynter E, Hanisee MK, Parker G, Kandil E, Darden M. Initial experience with biologic polymer scaffold (Poly-4-hydroxybuturate) in complex Abdominal Wall reconstruction. Ann Surg. 2017;266(1):185–8.CrossRef Buell JF, Sigmon D, Ducoin C, Shapiro M, Teja N, Wynter E, Hanisee MK, Parker G, Kandil E, Darden M. Initial experience with biologic polymer scaffold (Poly-4-hydroxybuturate) in complex Abdominal Wall reconstruction. Ann Surg. 2017;266(1):185–8.CrossRef
30.
Zurück zum Zitat Heniford BT, Walters AL, Lincourt AE, Novitsky YW, Hope WW, Kercher KW. Comparison of generic versus specific quality-of-life scales for mesh hernia repairs. J Am Coll Surg. 2008;206(4):638–44.CrossRef Heniford BT, Walters AL, Lincourt AE, Novitsky YW, Hope WW, Kercher KW. Comparison of generic versus specific quality-of-life scales for mesh hernia repairs. J Am Coll Surg. 2008;206(4):638–44.CrossRef
31.
Zurück zum Zitat EuroQol Group. EuroQol--a new facility for the measurement of health-related quality of life. Health Policy. 1990;16(3):199–208.CrossRef EuroQol Group. EuroQol--a new facility for the measurement of health-related quality of life. Health Policy. 1990;16(3):199–208.CrossRef
32.
Zurück zum Zitat Won EJ, Lehman EB, Geletzke AK, Tangel MR, Matsushima K, Brunke-Reese D, Pichardo-Lowden AR, Pauli EM, Soybel DI. Association of postoperative hyperglycemia with outcomes among patients with complex ventral hernia repair. JAMA Surg. 2015;150(5):433–40.CrossRef Won EJ, Lehman EB, Geletzke AK, Tangel MR, Matsushima K, Brunke-Reese D, Pichardo-Lowden AR, Pauli EM, Soybel DI. Association of postoperative hyperglycemia with outcomes among patients with complex ventral hernia repair. JAMA Surg. 2015;150(5):433–40.CrossRef
33.
Zurück zum Zitat Rodriguez-Unda N, Soares KC, Azoury SC, Baltodano PA, Hicks CW, Burce KK, Cornell P, Cooney CM, Eckhauser FE. Negative-pressure wound therapy in the Management of High-Grade Ventral Hernia Repairs. J Gastrointest Surg. 2015;19(11):2054–61.CrossRef Rodriguez-Unda N, Soares KC, Azoury SC, Baltodano PA, Hicks CW, Burce KK, Cornell P, Cooney CM, Eckhauser FE. Negative-pressure wound therapy in the Management of High-Grade Ventral Hernia Repairs. J Gastrointest Surg. 2015;19(11):2054–61.CrossRef
34.
Zurück zum Zitat Kugler NW, Bobbs M, Webb T, Carver TW, Milia D, Paul JS. A dual-stage approach to contaminated, high-risk ventral hernia repairs. J Surg Res. 2016;204(1):200–4.CrossRef Kugler NW, Bobbs M, Webb T, Carver TW, Milia D, Paul JS. A dual-stage approach to contaminated, high-risk ventral hernia repairs. J Surg Res. 2016;204(1):200–4.CrossRef
35.
Zurück zum Zitat Kanters AE, Krpata DM, Blatnik JA, Novitsky YM, Rosen MJ. Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs. J Am Coll Surg. 2012;215(6):787–93.CrossRef Kanters AE, Krpata DM, Blatnik JA, Novitsky YM, Rosen MJ. Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs. J Am Coll Surg. 2012;215(6):787–93.CrossRef
36.
Zurück zum Zitat Bondre IL, Holihan JL, Askenasy EP, Greenberg JA, Keith JN, Martindale RG, Roth JS, Liang MK, Ventral Hernia Outcomes C. Suture, synthetic, or biologic in contaminated ventral hernia repair. J Surg Res. 2016;200(2):488–94.CrossRef Bondre IL, Holihan JL, Askenasy EP, Greenberg JA, Keith JN, Martindale RG, Roth JS, Liang MK, Ventral Hernia Outcomes C. Suture, synthetic, or biologic in contaminated ventral hernia repair. J Surg Res. 2016;200(2):488–94.CrossRef
37.
Zurück zum Zitat Fischer JP, Basta MN, Mirzabeigi MN, Kovach SJ 3rd. A comparison of outcomes and cost in VHWG grade II hernias between rives-Stoppa synthetic mesh hernia repair versus underlay biologic mesh repair. Hernia. 2014;18(6):781–9.CrossRef Fischer JP, Basta MN, Mirzabeigi MN, Kovach SJ 3rd. A comparison of outcomes and cost in VHWG grade II hernias between rives-Stoppa synthetic mesh hernia repair versus underlay biologic mesh repair. Hernia. 2014;18(6):781–9.CrossRef
38.
Zurück zum Zitat Jones JW, Jurkovich GJ. Polypropylene mesh closure of infected abdominal wounds. Am Surg. 1989;55(1):73–6.PubMed Jones JW, Jurkovich GJ. Polypropylene mesh closure of infected abdominal wounds. Am Surg. 1989;55(1):73–6.PubMed
40.
Zurück zum Zitat Kim H, Bruen K, Vargo D. Acellular dermal matrix in the management of high-risk abdominal wall defects. Am J Surg. 2006;192(6):705–9.CrossRef Kim H, Bruen K, Vargo D. Acellular dermal matrix in the management of high-risk abdominal wall defects. Am J Surg. 2006;192(6):705–9.CrossRef
41.
Zurück zum Zitat Slater NJ, van der Kolk M, Hendriks T, van Goor H, Bleichrodt RP. Biologic grafts for ventral hernia repair: a systematic review. Am J Surg. 2013;205(2):220–30.CrossRef Slater NJ, van der Kolk M, Hendriks T, van Goor H, Bleichrodt RP. Biologic grafts for ventral hernia repair: a systematic review. Am J Surg. 2013;205(2):220–30.CrossRef
Metadaten
Titel
A post-market, prospective, multi-center, single-arm clinical investigation of Phasix™ mesh for VHWG grade 3 midline incisional hernia repair: a research protocol
verfasst von
M. M. J. van Rooijen
A. P. Jairam
T. Tollens
L. N. Jørgensen
T. S. de Vries Reilingh
G. Piessen
F. Köckerling
M. Miserez
A. C. J. Windsor
F. Berrevoet
R. H. Fortelny
B. Dousset
G. Woeste
H. L. van Westreenen
F. Gossetti
J. F. Lange
G. W. M. Tetteroo
A. Koch
L. F. Kroese
J. Jeekel
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
BMC Surgery / Ausgabe 1/2018
Elektronische ISSN: 1471-2482
DOI
https://doi.org/10.1186/s12893-018-0439-7

Weitere Artikel der Ausgabe 1/2018

BMC Surgery 1/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.