Skip to main content
Erschienen in: Neurocritical Care 1/2020

03.10.2019 | Viewpoint

A Proposal for a New Protocol for Sonographic Assessment of the Optic Nerve Sheath Diameter: The CLOSED Protocol

verfasst von: Raffaele Aspide, Giacomo Bertolini, Luca Albini Riccioli, Diego Mazzatenta, Giorgio Palandri, Daniele Guerino Biasucci

Erschienen in: Neurocritical Care | Ausgabe 1/2020

Einloggen, um Zugang zu erhalten

Abstract

Measuring and monitoring of intracranial pressure is considered standard of care in patients with suspected intracranial hypertension. Sonographic assessment of the optic nerve sheath diameter (ONSD) has been promising and potentially useful for noninvasive intracranial hypertension screening. ONSD measurements are easy to perform, repeatable at bedside, fast, low cost, and radiation-free. However, they are still burdened by inter-rater variability, lack of ultrasound (US) setting standardization (e.g., US frequency, focus depth, etc.), and possible artifacts. To overcome this problem, we propose the CLOSED protocol associated with equipment specifications, as a guide to minimize the occurrence of such artifacts enabling a more reliable and accurate measurement. We suggest that color Doppler could be used as a new standard evaluation for the ONSD.
Literatur
1.
Zurück zum Zitat Rossi S, Buzzi F, Paparella A, Mainini P, Stocchetti N. Complications and safety associated with ICP monitoring: a study of 542 patients. In: Marmarou A, et al., editors. Intracranial pressure and neuromonitoring in brain injury., Acta neurochirurgica supplementsVienna: Springer; 1998. Rossi S, Buzzi F, Paparella A, Mainini P, Stocchetti N. Complications and safety associated with ICP monitoring: a study of 542 patients. In: Marmarou A, et al., editors. Intracranial pressure and neuromonitoring in brain injury., Acta neurochirurgica supplementsVienna: Springer; 1998.
2.
Zurück zum Zitat Rebuck JA, Murry KR, Rhoney DH, Michael DB, Coplin WM. Infection related to intracranial pressure monitors in adults: analysis of risk factors and antibiotic prophylaxis. J Neurol Neurosurg Psychiatry. 2000;69:381–4.CrossRefPubMedPubMedCentral Rebuck JA, Murry KR, Rhoney DH, Michael DB, Coplin WM. Infection related to intracranial pressure monitors in adults: analysis of risk factors and antibiotic prophylaxis. J Neurol Neurosurg Psychiatry. 2000;69:381–4.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Ma R, Rowland D, Judge A, Calisto A, Jayamohan J, Johnson D, et al. Complications following intracranial pressure monitoring in children: a 6-year single-center experience. J Neurosurg Pediatr. 2018;21:278–83.CrossRefPubMed Ma R, Rowland D, Judge A, Calisto A, Jayamohan J, Johnson D, et al. Complications following intracranial pressure monitoring in children: a 6-year single-center experience. J Neurosurg Pediatr. 2018;21:278–83.CrossRefPubMed
4.
Zurück zum Zitat Robba C, Cardim D, Tajsic T, Pietersen J, Bulman M, Donnelly J, et al. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study. PLoS Med. 2017;14:e1002356.CrossRefPubMedPubMedCentral Robba C, Cardim D, Tajsic T, Pietersen J, Bulman M, Donnelly J, et al. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study. PLoS Med. 2017;14:e1002356.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Robba C, Santori G, Czosnyka M, Corradi F, Bragazzi N, Padayachy L, et al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018;44:1284–94.CrossRefPubMed Robba C, Santori G, Czosnyka M, Corradi F, Bragazzi N, Padayachy L, et al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018;44:1284–94.CrossRefPubMed
6.
Zurück zum Zitat Moretti R, Pizzi B, Cassini F, Vivaldi N. Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care. 2009;11:406.CrossRefPubMed Moretti R, Pizzi B, Cassini F, Vivaldi N. Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care. 2009;11:406.CrossRefPubMed
7.
Zurück zum Zitat Lochner P, Coppo L, Cantello R, Nardone R, Naldi A, Leone MA, et al. Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults. J Ultrasound. 2016;11:406. Lochner P, Coppo L, Cantello R, Nardone R, Naldi A, Leone MA, et al. Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults. J Ultrasound. 2016;11:406.
8.
Zurück zum Zitat Popovic D, Khoo M, Lee S. Noninvasive monitoring of intracranial pressure. Recent Patents Biomed Eng. 2009;2:165–79.CrossRef Popovic D, Khoo M, Lee S. Noninvasive monitoring of intracranial pressure. Recent Patents Biomed Eng. 2009;2:165–79.CrossRef
9.
Zurück zum Zitat Zeiler FA, Ziesmann MT, Goeres P, Unger B, Park J, Karakitsos D, et al. A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement. Crit Ultrasound J. 2016;8:9.CrossRefPubMedPubMedCentral Zeiler FA, Ziesmann MT, Goeres P, Unger B, Park J, Karakitsos D, et al. A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement. Crit Ultrasound J. 2016;8:9.CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Helmke K, Hansen HC. Fundamentals of transorbital sonographic: evaluation of optic nerve sheath expansion under intracranial hypertension. II. Patient study. Pediatr Radiol. 1996;26:701–10.CrossRefPubMed Helmke K, Hansen HC. Fundamentals of transorbital sonographic: evaluation of optic nerve sheath expansion under intracranial hypertension. II. Patient study. Pediatr Radiol. 1996;26:701–10.CrossRefPubMed
11.
Zurück zum Zitat Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study. Pediatr Radiol. 1996;26:701–5.CrossRefPubMed Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study. Pediatr Radiol. 1996;26:701–5.CrossRefPubMed
12.
Zurück zum Zitat Hansen H-C, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg. 1997;87:34–40.CrossRefPubMed Hansen H-C, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg. 1997;87:34–40.CrossRefPubMed
13.
Zurück zum Zitat Tsutsumi S, Rhoton AL. Microsurgical anatomy of the central retinal artery. Neurosurgery. 2006;59:870–9.CrossRefPubMed Tsutsumi S, Rhoton AL. Microsurgical anatomy of the central retinal artery. Neurosurgery. 2006;59:870–9.CrossRefPubMed
14.
Zurück zum Zitat Ertl M, Barinka F, Torka E, Altmann M, Pfister K, Helbig H, et al. Ocular color-coded sonography—a promising tool for neurologists and intensive care physicians. Ultraschall Med. 2014;35:422–31.CrossRefPubMed Ertl M, Barinka F, Torka E, Altmann M, Pfister K, Helbig H, et al. Ocular color-coded sonography—a promising tool for neurologists and intensive care physicians. Ultraschall Med. 2014;35:422–31.CrossRefPubMed
15.
Zurück zum Zitat Pribojszki M, Komáromi K, Csomor A, Vörös ES. Tortuous optic nerve-ECR 2017/C-2914. 2017. Pribojszki M, Komáromi K, Csomor A, Vörös ES. Tortuous optic nerve-ECR 2017/C-2914. 2017.
16.
Zurück zum Zitat Feldman MK, Katyal S, Blackwood MS. US artifacts. RadioGraphics. 2009;24:1179–89.CrossRef Feldman MK, Katyal S, Blackwood MS. US artifacts. RadioGraphics. 2009;24:1179–89.CrossRef
17.
Zurück zum Zitat Baad M, Lu ZF, Reiser I, Paushter D. Clinical significance of US artifacts. RadioGraphics. 2017;37:1408–23.CrossRefPubMed Baad M, Lu ZF, Reiser I, Paushter D. Clinical significance of US artifacts. RadioGraphics. 2017;37:1408–23.CrossRefPubMed
19.
Zurück zum Zitat Hewick SA, Fairhead AC, Culy JC, Atta HR. A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit. Br J Ophthalmol. 2004;88:551–5.CrossRefPubMedPubMedCentral Hewick SA, Fairhead AC, Culy JC, Atta HR. A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit. Br J Ophthalmol. 2004;88:551–5.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Coleman DJ, Silverman RH, Chabi A, Rondeau MJ, Shung KK, Cannata J, et al. High-resolution ultrasonic imaging of the posterior segment. Ophthalmology. 2004;111:1344–51.CrossRefPubMed Coleman DJ, Silverman RH, Chabi A, Rondeau MJ, Shung KK, Cannata J, et al. High-resolution ultrasonic imaging of the posterior segment. Ophthalmology. 2004;111:1344–51.CrossRefPubMed
21.
Zurück zum Zitat Toms DA. The mechanical index, ultrasound practices, and the ALARA principle. J Ultrasound Med. 2006;25:560–1.CrossRefPubMed Toms DA. The mechanical index, ultrasound practices, and the ALARA principle. J Ultrasound Med. 2006;25:560–1.CrossRefPubMed
22.
Zurück zum Zitat Shah S, Kimberly H, Marill K, Noble V. Ultrasound techniques to measure the optic nerve sheath: is a specialized probe necessary? Med Sci Monit. 2009;15:63–8. Shah S, Kimberly H, Marill K, Noble V. Ultrasound techniques to measure the optic nerve sheath: is a specialized probe necessary? Med Sci Monit. 2009;15:63–8.
23.
Zurück zum Zitat Nelson TR, Fowlkes JB, Abramowicz JS, Church CC. Ultrasound biosafety considerations for the practicing sonographer and sonologist. J Ultrasound Med. 2009;28:139–50.CrossRefPubMed Nelson TR, Fowlkes JB, Abramowicz JS, Church CC. Ultrasound biosafety considerations for the practicing sonographer and sonologist. J Ultrasound Med. 2009;28:139–50.CrossRefPubMed
24.
Zurück zum Zitat Safety Group of the British Medical Ultrasound Society. Guidelines for the safe use of diagnostic ultrasound equipment. Ultrasound. 2010;18:52–9.CrossRef Safety Group of the British Medical Ultrasound Society. Guidelines for the safe use of diagnostic ultrasound equipment. Ultrasound. 2010;18:52–9.CrossRef
25.
Zurück zum Zitat Romagnuolo L, Tayal V, Tomaszewski C, Saunders T, Norton HJ. Optic nerve sheath diameter does not change with patient position. Am J Emerg Med. 2005;23:686–8.CrossRefPubMed Romagnuolo L, Tayal V, Tomaszewski C, Saunders T, Norton HJ. Optic nerve sheath diameter does not change with patient position. Am J Emerg Med. 2005;23:686–8.CrossRefPubMed
26.
Zurück zum Zitat Roque PJ, Hatch N, Barr L, Wu TS. Bedside ocular ultrasound. Crit Care Clin. 2014;30:227–41.CrossRefPubMed Roque PJ, Hatch N, Barr L, Wu TS. Bedside ocular ultrasound. Crit Care Clin. 2014;30:227–41.CrossRefPubMed
27.
Zurück zum Zitat Rubens DJ, Bhatt S, Nedelka S, Cullinan J. Doppler artifacts and pitfalls. Radiol Clin N Am. 2006;44:805–35.CrossRefPubMed Rubens DJ, Bhatt S, Nedelka S, Cullinan J. Doppler artifacts and pitfalls. Radiol Clin N Am. 2006;44:805–35.CrossRefPubMed
28.
Zurück zum Zitat Shankar H, Pagel PS. Potential adverse ultrasound-related biological effects: a critical review. Anesthesiology. 2011;115:1109–24.CrossRefPubMed Shankar H, Pagel PS. Potential adverse ultrasound-related biological effects: a critical review. Anesthesiology. 2011;115:1109–24.CrossRefPubMed
29.
Zurück zum Zitat Ertl M, Gamulescu M-A, Schlachetzki F. Application of orbital sonography in neurology. In: Thoirs K, editor. sonography. Rijeka: InTech; 2012. Ertl M, Gamulescu M-A, Schlachetzki F. Application of orbital sonography in neurology. In: Thoirs K, editor. sonography. Rijeka: InTech; 2012.
30.
Zurück zum Zitat Rasulo FBR. Transcranial Doppler and optic nerve sonography. J Cardiothorac Vasc Anesth. 2019;33:S38–52.CrossRefPubMed Rasulo FBR. Transcranial Doppler and optic nerve sonography. J Cardiothorac Vasc Anesth. 2019;33:S38–52.CrossRefPubMed
Metadaten
Titel
A Proposal for a New Protocol for Sonographic Assessment of the Optic Nerve Sheath Diameter: The CLOSED Protocol
verfasst von
Raffaele Aspide
Giacomo Bertolini
Luca Albini Riccioli
Diego Mazzatenta
Giorgio Palandri
Daniele Guerino Biasucci
Publikationsdatum
03.10.2019
Verlag
Springer US
Erschienen in
Neurocritical Care / Ausgabe 1/2020
Print ISSN: 1541-6933
Elektronische ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-019-00853-x

Weitere Artikel der Ausgabe 1/2020

Neurocritical Care 1/2020 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.