Abstract

Catheter stability, an important factor in ablation success, is affected by ventilation. Optimal ventilation strategies for pediatric catheter ablation are not known. We hypothesized that small tidal volume and positive end-expiratory pressure are associated with reduced ablation catheter movement at annular positions. Subjects aged 5–25 years undergoing ablation for supraventricular tachycardia (SVT) or WPW at two centers from March 2015 to September 2016 were prospectively enrolled and randomized to receive mechanical ventilation with either positive end-expiratory pressure of 5 cm H2O (PEEP) or 0 cm H2O (ZEEP). Movement of the ablation catheter tip at standard annular positions was measured using 3D electroanatomic mapping systems under two conditions: small tidal volume (STV) (3–5 mL/kg) or large TV (LTV) (6–8 mL/kg). 58 subjects (mean age 13.8 years) were enrolled for a total of 266 separate observations of catheter movement. STV ventilation was associated with significantly reduced catheter movement, compared to LTV at all positions (right posteroseptal: 2.5 ± 1.4 vs. 5.2 ± 3.1 mm, p < 0.0001; right lateral: 2.7 ± 1.6 vs. 6.3 ± 3.5 mm, p < 0.0001; left lateral: 1.8 ± 1.0 vs. 4.3 ± 1.9 mm, p < 0.0001). The presence or absence of PEEP had no effect on catheter movement. In multivariable analysis, STV was associated with a 3.1-mm reduction in movement (95% CI 2.6–3.5, p < 0.0001), adjusting for end-expiratory pressure, annular location, and patient size. We conclude that STV ventilation is associated with reduced ablation catheter movement compared to a LTV strategy, independent of PEEP and annular position.
Literatur
1.
Zurück zum Zitat Van Hare GF, Javitz H, Carmelli D, Saul JP, Tanel RE, Fischbach PS, Kanter RJ, Schaffer M, Dunnigan A, Colan S, Serwer G (2004) Prospective assessment after pediatric cardiac ablation: recurrence at 1 year after initially successful ablation of supraventricular tachycardia. Heart Rhythm 1(2):188–196CrossRefPubMedPubMedCentral Van Hare GF, Javitz H, Carmelli D, Saul JP, Tanel RE, Fischbach PS, Kanter RJ, Schaffer M, Dunnigan A, Colan S, Serwer G (2004) Prospective assessment after pediatric cardiac ablation: recurrence at 1 year after initially successful ablation of supraventricular tachycardia. Heart Rhythm 1(2):188–196CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Van Hare GF, Javitz H, Carmelli D, Saul JP, Tanel RE, Fischbach PS, Kanter RJ, Schaffer M, Dunnigan A, Colan S, Serwer G (2004) Prospective assessment after pediatric cardiac ablation: demographics, medical profiles, and initial outcomes. J Cardiovasc Electrophysiol 15(7):759–770CrossRefPubMed Van Hare GF, Javitz H, Carmelli D, Saul JP, Tanel RE, Fischbach PS, Kanter RJ, Schaffer M, Dunnigan A, Colan S, Serwer G (2004) Prospective assessment after pediatric cardiac ablation: demographics, medical profiles, and initial outcomes. J Cardiovasc Electrophysiol 15(7):759–770CrossRefPubMed
3.
Zurück zum Zitat Ceresnak SR, Kahana M, Zucker HA, Mann G, Nappo L, Pass RH (2014) Effects of ventilation and catheter position on catheter movement on the tricuspid annulus during ablation in children. Pacing Clin Electrophysiol 37(8):1051–1057CrossRefPubMed Ceresnak SR, Kahana M, Zucker HA, Mann G, Nappo L, Pass RH (2014) Effects of ventilation and catheter position on catheter movement on the tricuspid annulus during ablation in children. Pacing Clin Electrophysiol 37(8):1051–1057CrossRefPubMed
4.
Zurück zum Zitat Noseworthy PA, Malchano ZJ, Ahmed J, Holmvang G, Ruskin JN, Reddy VY (2005) The impact of respiration on left atrial and pulmonary venous anatomy: implications for image-guided intervention. Heart Rhythm 2(11):1173–1178CrossRefPubMed Noseworthy PA, Malchano ZJ, Ahmed J, Holmvang G, Ruskin JN, Reddy VY (2005) The impact of respiration on left atrial and pulmonary venous anatomy: implications for image-guided intervention. Heart Rhythm 2(11):1173–1178CrossRefPubMed
5.
Zurück zum Zitat Kumar S, Morton JB, Halloran K, Spence SJ, Lee G, Wong MC, Kistler PM, Kalman JM (2012) Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmias. Heart Rhythm 9(7):1041–1047 e1041CrossRefPubMed Kumar S, Morton JB, Halloran K, Spence SJ, Lee G, Wong MC, Kistler PM, Kalman JM (2012) Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmias. Heart Rhythm 9(7):1041–1047 e1041CrossRefPubMed
6.
Zurück zum Zitat Goode JS Jr, Taylor RL, Buffington CW, Klain MM, Schwartzman D (2006) High-frequency jet ventilation: utility in posterior left atrial catheter ablation. Heart Rhythm 3(1):13–19CrossRefPubMed Goode JS Jr, Taylor RL, Buffington CW, Klain MM, Schwartzman D (2006) High-frequency jet ventilation: utility in posterior left atrial catheter ablation. Heart Rhythm 3(1):13–19CrossRefPubMed
7.
Zurück zum Zitat Pecht B, Maginot KR, Boramanand NK, Perry JC (2002) Techniques to avoid atrioventricular block during radiofrequency catheter ablation of septal tachycardia substrates in young patients. J Interv Card Electrophysiol 7(1):83–88CrossRefPubMed Pecht B, Maginot KR, Boramanand NK, Perry JC (2002) Techniques to avoid atrioventricular block during radiofrequency catheter ablation of septal tachycardia substrates in young patients. J Interv Card Electrophysiol 7(1):83–88CrossRefPubMed
8.
Zurück zum Zitat Friedman PA (2012) Hitting a moving target: catheter ablation and respiration. Heart Rhythm 9(7):1048–1049CrossRefPubMed Friedman PA (2012) Hitting a moving target: catheter ablation and respiration. Heart Rhythm 9(7):1048–1049CrossRefPubMed
9.
Zurück zum Zitat Hutchinson MD, Garcia FC, Mandel JE, Elkassabany N, Zado ES, Riley MP, Cooper JM, Bala R, Frankel DS, Lin D, Supple GE, Dixit S, Gerstenfeld EP, Callans DJ, Marchlinski FE (2013) Efforts to enhance catheter stability improve atrial fibrillation ablation outcome. Heart Rhythm 10(3):347–353CrossRefPubMed Hutchinson MD, Garcia FC, Mandel JE, Elkassabany N, Zado ES, Riley MP, Cooper JM, Bala R, Frankel DS, Lin D, Supple GE, Dixit S, Gerstenfeld EP, Callans DJ, Marchlinski FE (2013) Efforts to enhance catheter stability improve atrial fibrillation ablation outcome. Heart Rhythm 10(3):347–353CrossRefPubMed
10.
Zurück zum Zitat Goldberg CS, Caplan MJ, Heidelberger KP, Dick M (1999) The dimensions of the triangle of Koch in children. Am J Cardiol 83(1):117–120CrossRefPubMed Goldberg CS, Caplan MJ, Heidelberger KP, Dick M (1999) The dimensions of the triangle of Koch in children. Am J Cardiol 83(1):117–120CrossRefPubMed
11.
Zurück zum Zitat Vazir-Marino F, Young ML, Kohli V, Barron M, Wolff GS (1999) Controlled ventilation enhances catheter stability during radiofrequency ablation. Pacing Clin Electrophysiol 22(1):86–90CrossRefPubMed Vazir-Marino F, Young ML, Kohli V, Barron M, Wolff GS (1999) Controlled ventilation enhances catheter stability during radiofrequency ablation. Pacing Clin Electrophysiol 22(1):86–90CrossRefPubMed
12.
Zurück zum Zitat Packer D (2005) Three-dimensional mapping in interventional electrophysiology: techniques and technology. J Cardiovasc Electrophysiol 16:1110–1116CrossRefPubMed Packer D (2005) Three-dimensional mapping in interventional electrophysiology: techniques and technology. J Cardiovasc Electrophysiol 16:1110–1116CrossRefPubMed
13.
Zurück zum Zitat Beinart R, Kabra R, Heist KE, Blendea D, Barrett CD, Danik SB, Collins R, Ruskin JN, Mansour M (2011) Respiratory compensation improves the accuracy of electroanatomic mapping of the left atrium and pulmonary veins during atrial fibrillation ablation. J Interv Card Electrophysiol 32(2):105–110CrossRefPubMed Beinart R, Kabra R, Heist KE, Blendea D, Barrett CD, Danik SB, Collins R, Ruskin JN, Mansour M (2011) Respiratory compensation improves the accuracy of electroanatomic mapping of the left atrium and pulmonary veins during atrial fibrillation ablation. J Interv Card Electrophysiol 32(2):105–110CrossRefPubMed
14.
Zurück zum Zitat Szeplaki G, Geller L, Ozcan EE, Tahin T, Kovacs OM, Parazs N, Karady J, Maurovich-Horvat P, Szilagyi S, Osztheimer I, Toth A, Merkely B (2016) Respiratory gating algorithm helps to reconstruct more accurate electroanatomical maps during atrial fibrillation ablation performed under spontaneous respiration. J Interv Card Electrophysiol 46(2):153–159CrossRefPubMed Szeplaki G, Geller L, Ozcan EE, Tahin T, Kovacs OM, Parazs N, Karady J, Maurovich-Horvat P, Szilagyi S, Osztheimer I, Toth A, Merkely B (2016) Respiratory gating algorithm helps to reconstruct more accurate electroanatomical maps during atrial fibrillation ablation performed under spontaneous respiration. J Interv Card Electrophysiol 46(2):153–159CrossRefPubMed
15.
Zurück zum Zitat Eitel C, Hindricks G, Dagres N, Sommer P, Piorkowski C (2010) EnSite velocity cardiac mapping system: a new platform for 3D mapping of cardiac arrhythmias. Expert Rev Med Devices 7(2):185–192CrossRefPubMed Eitel C, Hindricks G, Dagres N, Sommer P, Piorkowski C (2010) EnSite velocity cardiac mapping system: a new platform for 3D mapping of cardiac arrhythmias. Expert Rev Med Devices 7(2):185–192CrossRefPubMed
16.
Zurück zum Zitat Saul PJ, Kanter RJ (2016) PACES/HRS expert consensus statement on the use of catheter ablation in children and patients with congenital heart disease: Developed in partnership with the Pediatric and Congenital Electrophysiology Society (PACES) and the Heart Rhythm Society (HRS). Endorsed by the governing bodies of PACES, HRS, the American Academy of Pediatrics (AAP), the American Heart Association (AHA), and the Association for European Pediatric and Congenital Cardiology (AEPC). Heart Rhythm 13(6):e251–e289CrossRef Saul PJ, Kanter RJ (2016) PACES/HRS expert consensus statement on the use of catheter ablation in children and patients with congenital heart disease: Developed in partnership with the Pediatric and Congenital Electrophysiology Society (PACES) and the Heart Rhythm Society (HRS). Endorsed by the governing bodies of PACES, HRS, the American Academy of Pediatrics (AAP), the American Heart Association (AHA), and the Association for European Pediatric and Congenital Cardiology (AEPC). Heart Rhythm 13(6):e251–e289CrossRef
17.
Zurück zum Zitat Di Biase L, Conti S, Mohanty P, Bai R, Sanchez J, Walton D, John A, Santangeli P, Elayi CS, Beheiry S, Gallinghouse GJ, Mohanty S, Horton R, Bailey S, Burkhardt JD, Natale A (2011) General anesthesia reduces the prevalence of pulmonary vein reconnection during repeat ablation when compared with conscious sedation: results from a randomized study. Heart Rhythm 8(3):368–372CrossRefPubMed Di Biase L, Conti S, Mohanty P, Bai R, Sanchez J, Walton D, John A, Santangeli P, Elayi CS, Beheiry S, Gallinghouse GJ, Mohanty S, Horton R, Bailey S, Burkhardt JD, Natale A (2011) General anesthesia reduces the prevalence of pulmonary vein reconnection during repeat ablation when compared with conscious sedation: results from a randomized study. Heart Rhythm 8(3):368–372CrossRefPubMed
Metadaten
Titel
A Prospective Assessment of Optimal Mechanical Ventilation Parameters for Pediatric Catheter Ablation
verfasst von
Christopher M. Janson
Scott R. Ceresnak
Jaeun M. Choi
Anne M. Dubin
Kara S. Motonaga
Glenn E. Mann
Madelyn Kahana
Ingrid Fitz-James
Lisa Wise-Faberowski
Komal Kamra
Lynn Nappo
Anthony Trela
Robert H. Pass
Publikationsdatum
03.09.2018
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 1/2019
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-018-1968-7

Weitere Artikel der Ausgabe 1/2019

Pediatric Cardiology 1/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.