Skip to main content
Erschienen in: International Urogynecology Journal 11/2017

24.04.2017 | Original Article

A rat hysteropexy model for evaluating adhesion formation and comparison of two different structured meshes

verfasst von: Ayse Filiz Gokmen-Karasu, Serdar Aydin, Fatma Cavide Sonmez, Ilknur Adanir, Gulsah Ilhan, Seda Ates

Erschienen in: International Urogynecology Journal | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Introduction and hypothesis

Peritonization of mesh during sacrohysteropexy is generally advocated to prevent adhesions to the viscera; however, randomized clinical trials are lacking, and peritonization may not be completely possible in a laparoscopic hysteropexy procedure. Our main objective was to describe a basic experimental rat sacrohysteropexy model. We hypothesized that even when peritoneal closure was omitted, using composite mesh would result in less adhesions to the viscera.

Methods

Twenty in-bred female virgin Wistar Hannover rats were used in this study. Standardized hysteropexy procedure and adhesion model is described step by step with two different mesh materials: polypropylene and a composite polyester. Mesh was anchored between the posterior cervix and anterior longitudinal ligament of the lumbar vertebrae. Macroscopic adhesion scores and histopathological tissue reaction was investigated.

Results

Macroscopically, the surface area involved in adhesions was similar between groups. However, adhesions in the polypropylene group were more dense, required sharp dissection for lysis, and yielded higher total macroscopic adhesion scores (p < 0.001). Histologically, a more pronounced host inflammatory response was encountered in the polyester group (p < 0.001).

Conclusions

We describe a rat hysteropexy model and a previously established uterine adhesion model. Adhesion scores in the composite mesh group were lower, and bowel involvement was not seen. Our findings are promising, and further research investigating antiadhesive composite mesh use for hysterosacropexy would be appropriate, especially when peritoneal closure is omitted.
Literatur
3.
Zurück zum Zitat Sergent F, Resch B, Loisel C, Bisson V, Scha-al JP, Marpeau L. Mid-term outcome of laparoscopic sacrocolpopexy with anterior and posterior polyester mesh for treatment of genito-urinary prolapse. Eur J Obstet Gynecol Reprod Biol. 2011;156:217–22. doi:10.1016/j.ejogrb.2011.01.022.CrossRefPubMed Sergent F, Resch B, Loisel C, Bisson V, Scha-al JP, Marpeau L. Mid-term outcome of laparoscopic sacrocolpopexy with anterior and posterior polyester mesh for treatment of genito-urinary prolapse. Eur J Obstet Gynecol Reprod Biol. 2011;156:217–22. doi:10.​1016/​j.​ejogrb.​2011.​01.​022.CrossRefPubMed
4.
Zurück zum Zitat Deffieux X, Letouzey V, Savary D, Sentilhes L, Agostini A, Mares P, Pierre F. Prevention of complications related to the use of prosthetic meshes in prolapse surgery: guidelines for clinical practice. Eur J Obstet Gynecol Reprod Biol. 2012;165:170–80. doi:10.1016/j.ejogrb.2012.09.001.CrossRefPubMed Deffieux X, Letouzey V, Savary D, Sentilhes L, Agostini A, Mares P, Pierre F. Prevention of complications related to the use of prosthetic meshes in prolapse surgery: guidelines for clinical practice. Eur J Obstet Gynecol Reprod Biol. 2012;165:170–80. doi:10.​1016/​j.​ejogrb.​2012.​09.​001.CrossRefPubMed
7.
Zurück zum Zitat Moore R, Moriarty C, Chinthakanan O, Miklos J. Laparoscopic sacrocolpopexy: operative times and efficiency in a high-volume female pelvic medicine and laparoscopic surgery practice. Int Urogynecol J. 2016; doi:10.1007/s00192-016-3179-1. Moore R, Moriarty C, Chinthakanan O, Miklos J. Laparoscopic sacrocolpopexy: operative times and efficiency in a high-volume female pelvic medicine and laparoscopic surgery practice. Int Urogynecol J. 2016; doi:10.​1007/​s00192-016-3179-1.
9.
Zurück zum Zitat Konstantinovic ML, Pille E, Malinowska M, Verbeken E, De Ridder D, Deprest J. Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model. Int Urogynecol J. 2007;18:619–26. doi:10.1007/s00192-006-0202-y.CrossRef Konstantinovic ML, Pille E, Malinowska M, Verbeken E, De Ridder D, Deprest J. Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model. Int Urogynecol J. 2007;18:619–26. doi:10.​1007/​s00192-006-0202-y.CrossRef
10.
Zurück zum Zitat Bellón JM, Rodríguez M, García-Honduvilla N, Pascual G, Gómez Gil V, Buján J. Peritoneal effects of prosthetic meshes used to repair abdominal wall defects: monitoring adhesions by sequential laparoscopy. J Laparoendosc Adv Surg Tech. 2007;17:160–6. doi:10.1089/lap.2006.0028.CrossRef Bellón JM, Rodríguez M, García-Honduvilla N, Pascual G, Gómez Gil V, Buján J. Peritoneal effects of prosthetic meshes used to repair abdominal wall defects: monitoring adhesions by sequential laparoscopy. J Laparoendosc Adv Surg Tech. 2007;17:160–6. doi:10.​1089/​lap.​2006.​0028.CrossRef
11.
Zurück zum Zitat Badylak S, Kokini K, Tullius B, Simmons-Byrd A, Morff R. Morphologic study of small intestinal submucosa as a body wall repair device. J Surg Res. 2002;103:190–202.CrossRefPubMed Badylak S, Kokini K, Tullius B, Simmons-Byrd A, Morff R. Morphologic study of small intestinal submucosa as a body wall repair device. J Surg Res. 2002;103:190–202.CrossRefPubMed
12.
Zurück zum Zitat Falconer C, Söderberg M, Blomgren B, Ulmsten U. Influence of different sling materials on connective tissue metabolism in stress urinary incontinent women. Int Urogynecol J. 2001;12:S19–23.CrossRef Falconer C, Söderberg M, Blomgren B, Ulmsten U. Influence of different sling materials on connective tissue metabolism in stress urinary incontinent women. Int Urogynecol J. 2001;12:S19–23.CrossRef
18.
Zurück zum Zitat Cundiff GW, Harris RL, Coates K, Low VH, Bump RC, Addison WA. Abdominal sacral colpoperineopexy: a new approach for correction of posterior compartment defects and perineal descent associated with vaginal vault prolapse. Am J Obstet Gynecol. 1997;177:1345–55. doi:10.1016/S0002-9378(97)70074-7.CrossRefPubMed Cundiff GW, Harris RL, Coates K, Low VH, Bump RC, Addison WA. Abdominal sacral colpoperineopexy: a new approach for correction of posterior compartment defects and perineal descent associated with vaginal vault prolapse. Am J Obstet Gynecol. 1997;177:1345–55. doi:10.​1016/​S0002-9378(97)70074-7.CrossRefPubMed
19.
Zurück zum Zitat Leonardo C, Gentili G, Leonardo F. Abdominal sacral colpopexy with Mersilene mesh. Urol Int. 2002;68:6–9.CrossRefPubMed Leonardo C, Gentili G, Leonardo F. Abdominal sacral colpopexy with Mersilene mesh. Urol Int. 2002;68:6–9.CrossRefPubMed
20.
Zurück zum Zitat Menefee SA, Miller KF, Wall LL. Results of abdominal sacral Colpopexy using polyester mesh in the treatment of Posthysterectomy vaginal vault prolapse and Enterocele. Female Pelvic Med Reconstruct Surg. 1999;5:136–42. Menefee SA, Miller KF, Wall LL. Results of abdominal sacral Colpopexy using polyester mesh in the treatment of Posthysterectomy vaginal vault prolapse and Enterocele. Female Pelvic Med Reconstruct Surg. 1999;5:136–42.
21.
Zurück zum Zitat Kohli N, Walsh PM, Roat TW, Karram MM. Mesh erosion after abdominal sacrocolpopexy. Obstet Gynecol. 1998;92:999–1004.PubMed Kohli N, Walsh PM, Roat TW, Karram MM. Mesh erosion after abdominal sacrocolpopexy. Obstet Gynecol. 1998;92:999–1004.PubMed
Metadaten
Titel
A rat hysteropexy model for evaluating adhesion formation and comparison of two different structured meshes
verfasst von
Ayse Filiz Gokmen-Karasu
Serdar Aydin
Fatma Cavide Sonmez
Ilknur Adanir
Gulsah Ilhan
Seda Ates
Publikationsdatum
24.04.2017
Verlag
Springer London
Erschienen in
International Urogynecology Journal / Ausgabe 11/2017
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-017-3328-1

Weitere Artikel der Ausgabe 11/2017

International Urogynecology Journal 11/2017 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.