Purpose

To describe a sample predictive model for intraocular pressure (IOP) following laser in situ keratomileusis (LASIK) for myopia and an IOP constant.

Methods

The records of patients that underwent LASIK for myopia and myopic astigmatism via WaveLight Allegretto Wave Eye-Q 400 Hz excimer laser and Hansatome XP microkeratome were retrospectively reviewed. Patients with no systemic or ocular disease other than myopia or myopic astigmatism were included in the study. Preoperative and postoperative month 1 data and intraoperative data were used to build the predictive model for IOP after LASIK. The IOP constant was calculated by subtracting the predicted IOP from preoperative IOP. The paired samples t test, Pearson’s correlation analysis, curve estimation analysis, and linear regression analysis were used to evaluate the study data.

Results

The study included 425 eyes in 214 patients with a mean age of 32 ± 7.8 years. Mean spherical equivalent of the attempted correction (SE-ac) was −3.7 ± 1.7 diopters. Mean post-LASIK decrease in IOP was 4.6 ± 2.3 mmHg. The difference between preoperative and postoperative IOP was statistically significant (P < 0.001). SE-ac, preoperative IOP, and central corneal thickness had highly significant effects on postoperative IOP, based on linear regression analysis (P < 0.001 and R 2 = 0.043, P < 0.001 and R 2 = 0.370, and P < 0.001 and R 2 = 0.132, respectively). Regression model was created (F = 127.733, P < 0.001), and the adjusted R 2 value was 0.548.

Conclusions

Evaluation of IOP after LASIK is important in myopic patients. The present study described a practical formula for predicting the true IOP with the aid of an IOP constant value in myopic eyes following LASIK.
Literatur
2.
Zurück zum Zitat Kohlhaas M, Spoerl E, Boehm AG, Pollack K (2006) A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg 22:263–267PubMed Kohlhaas M, Spoerl E, Boehm AG, Pollack K (2006) A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg 22:263–267PubMed
3.
Zurück zum Zitat Yang CC, Wang IJ, Chang YC, Lin LL, Chen TH (2006) A predictive model for postoperative intraocular pressure among patients undergoing laser in situ keratomileusis (LASIK). Am J Ophthalmol 141:530–536CrossRefPubMed Yang CC, Wang IJ, Chang YC, Lin LL, Chen TH (2006) A predictive model for postoperative intraocular pressure among patients undergoing laser in situ keratomileusis (LASIK). Am J Ophthalmol 141:530–536CrossRefPubMed
4.
Zurück zum Zitat Kucuksumer Y, Sivrikaya H, Bayraktar S, Yilmaz OF (2001) Effects of ocular parameters on intraocular pressure changes after laser in situ keratomileusis. Turk J Ophthalmol 31:139–145 Kucuksumer Y, Sivrikaya H, Bayraktar S, Yilmaz OF (2001) Effects of ocular parameters on intraocular pressure changes after laser in situ keratomileusis. Turk J Ophthalmol 31:139–145
5.
Zurück zum Zitat Sentut S, Yilmaz S, Maden A (2008) Comparison of intraocular pressure measurements from peripheral and central cornea after LASIK procedure. J Glaucoma Cataract 3:186–189 Sentut S, Yilmaz S, Maden A (2008) Comparison of intraocular pressure measurements from peripheral and central cornea after LASIK procedure. J Glaucoma Cataract 3:186–189
7.
Zurück zum Zitat Cheng AC, Fan D, Tang E, Lam DS (2006) Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery. Cornea 25:26–28CrossRefPubMed Cheng AC, Fan D, Tang E, Lam DS (2006) Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery. Cornea 25:26–28CrossRefPubMed
8.
Zurück zum Zitat Chang DH, Stulting RD (2005) Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap. Ophthalmology 112:1009–1016CrossRefPubMed Chang DH, Stulting RD (2005) Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap. Ophthalmology 112:1009–1016CrossRefPubMed
9.
Zurück zum Zitat Diggle PJ, Liang KY, Zeger SL (1994) Analysis of longitudinal data. Oxford University Press, New York Diggle PJ, Liang KY, Zeger SL (1994) Analysis of longitudinal data. Oxford University Press, New York
10.
Zurück zum Zitat Mitchell P, Hourihan F, Sandbach J, Wang JJ (1999) The relationship between glaucoma and myopia: the Blue Mountains Eye Study. Ophthalmology 106:2010–2015CrossRefPubMed Mitchell P, Hourihan F, Sandbach J, Wang JJ (1999) The relationship between glaucoma and myopia: the Blue Mountains Eye Study. Ophthalmology 106:2010–2015CrossRefPubMed
11.
Zurück zum Zitat Emara B, Probst LE, Tingey DP, Kennedy DW, Willms LJ, Machat J (1998) Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg 24:1320–1325CrossRefPubMed Emara B, Probst LE, Tingey DP, Kennedy DW, Willms LJ, Machat J (1998) Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg 24:1320–1325CrossRefPubMed
12.
Zurück zum Zitat Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT (1997) Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol 123:767–772CrossRefPubMed Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT (1997) Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol 123:767–772CrossRefPubMed
13.
14.
Zurück zum Zitat Sakalar YB, Keklikci U, Balsak S, Dogan E, Unlu K (2010) Comparison of different methods for measurement of intraocular pressure and evaluation of effect of central corneal thickness on measurement results. Turk J Ophthalmol 40:156–159CrossRef Sakalar YB, Keklikci U, Balsak S, Dogan E, Unlu K (2010) Comparison of different methods for measurement of intraocular pressure and evaluation of effect of central corneal thickness on measurement results. Turk J Ophthalmol 40:156–159CrossRef
15.
Zurück zum Zitat Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD (1997) The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology 104:945–948CrossRefPubMed Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD (1997) The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology 104:945–948CrossRefPubMed
16.
Zurück zum Zitat Gimeno JA, Munoz LA, Valenzuela LA, Molto FJ, Rahhal MS (2000) Influence of refraction on tonometric readings after photorefractive keratectomy and laser assisted in situ keratomileusis. Cornea 19:512–516CrossRefPubMed Gimeno JA, Munoz LA, Valenzuela LA, Molto FJ, Rahhal MS (2000) Influence of refraction on tonometric readings after photorefractive keratectomy and laser assisted in situ keratomileusis. Cornea 19:512–516CrossRefPubMed
17.
Zurück zum Zitat Park HJ, Uhm KB, Hong C (2001) Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg 27:303–309CrossRefPubMed Park HJ, Uhm KB, Hong C (2001) Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg 27:303–309CrossRefPubMed
18.
Zurück zum Zitat El Danasoury MA, El Maghraby A, Coorpender SJ (2001) Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis. J Refract Surg 17:97–104PubMed El Danasoury MA, El Maghraby A, Coorpender SJ (2001) Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis. J Refract Surg 17:97–104PubMed
19.
Zurück zum Zitat Duch S, Serra A, Castanera J, Abos R, Quintana M (2001) Tonometry after laser in situ keratomileusis treatment. J Glaucoma 10:261–265CrossRefPubMed Duch S, Serra A, Castanera J, Abos R, Quintana M (2001) Tonometry after laser in situ keratomileusis treatment. J Glaucoma 10:261–265CrossRefPubMed
20.
Zurück zum Zitat Chihara E, Takahashi H, Okazaki K, Park M, Tanito M (2005) The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia. Br J Ophthalmol 89:160–164CrossRefPubMedPubMedCentral Chihara E, Takahashi H, Okazaki K, Park M, Tanito M (2005) The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia. Br J Ophthalmol 89:160–164CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Recep OF, Cagil N, Hasiripi H (2000) Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis. J Cataract Refract Surg 26:1480–1483CrossRefPubMed Recep OF, Cagil N, Hasiripi H (2000) Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis. J Cataract Refract Surg 26:1480–1483CrossRefPubMed
22.
Zurück zum Zitat De Moraes CGV, Prata TS, Liebmann J, Ritch R (2008) Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J Optom 1:43–49CrossRefPubMedCentral De Moraes CGV, Prata TS, Liebmann J, Ritch R (2008) Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J Optom 1:43–49CrossRefPubMedCentral
25.
Metadaten
Titel
A sample predictive model for intraocular pressure following laser in situ keratomileusis for myopia and an “intraocular pressure constant”
verfasst von
Ayse Ebru Bahadir Kilavuzoglu
Tahir Kansu Bozkurt
Cemile Banu Cosar
Asım Bozkurt Sener
Publikationsdatum
24.06.2017
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 4/2018
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0617-0

Weitere Artikel der Ausgabe 4/2018

International Ophthalmology 4/2018 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.