Skip to main content
Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases 8/2022

16.07.2022 | Original Article

A side-by-side comparison of the performance and time-and-motion data of VITEK MS

verfasst von: Marta Bardelli, Michela Padovani, Simona Fiorentini, Arnaldo Caruso, Deborah Yamamura, Mark Gaskin, Ali Jissam, Juan José González-López, M. Nieves Larrosa, Tomàs Pumarola, Anna Lassus, Barbara Louis, Nicolas Capron

Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases | Ausgabe 8/2022

Einloggen, um Zugang zu erhalten

Abstract

Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry systems are designed for rapid and reliable microbial identification. VITEK MS PRIME is the bioMérieux’s new generation instrument equipped with a continuous load-and-go sample loading system, urgent slide prioritization for critical patient samples and new internal components for faster identification. The aim of this study was to assess the performance of VITEK MS PRIME and to compare it to that of the VITEK MS system. In addition, at two sites, we performed a time-and-motion study to evaluate the efficiency of sample analysis from colony picking to slide removal from the instrument. We analyzed by VITEK MS and VITEK MS PRIME a total of 1413 isolates (1320 bacterial and 76 yeast) deriving from routine diagnostic samples that came into four laboratories in Canada, France, Italy, and Spain. VITEK MS PRIME and VITEK MS were concordant to the species and genus level for 1354/1413 (95.8%) and to the species level for 1341/1413 (94.9%). The identification and concordance rates in individual centers were largely homogenous. Overall, VITEK MS PRIME identified 1370/1413 (97.0%) of isolates compared to 1367/1413 (96.7%) identified by VITEK MS. Identification rates were consistently high for all microorganism categories. A time-and-motion study showed that the use of VITEK MS PRIME was associated with significant time saving. VITEK MS PRIME performs as well as VITEK MS and reduces the time necessary for pathogen identification. To fully optimize the laboratory process and obtain maximum efficiency, VITEK MS PRIME must be integrated into the laboratory workflow.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Maurer FP, Christner M, Hentschke M, Rohde H (2017) Advances in rapid identification and susceptibility testing of bacteria in the clinical microbiology laboratory: implications for patient care and antimicrobial stewardship programs. Infect Dis Rep 9(1):6839CrossRef Maurer FP, Christner M, Hentschke M, Rohde H (2017) Advances in rapid identification and susceptibility testing of bacteria in the clinical microbiology laboratory: implications for patient care and antimicrobial stewardship programs. Infect Dis Rep 9(1):6839CrossRef
2.
Zurück zum Zitat Franco-Duarte R, Cernakova L, Kadam S, Kaushik KS, Salehi B, Bevilacqua A, Corbo MR, Antolak H, Dybka-Stepien K, Leszczewicz M, RelisonTintino S, Alexandrino de Souza VC, Sharifi-Rad J, Coutinho HDM, Martins N, Rodrigues CF (2019) Advances in chemical and biological methods to identify microorganisms-from past to present. Microorganisms 7(5):130CrossRef Franco-Duarte R, Cernakova L, Kadam S, Kaushik KS, Salehi B, Bevilacqua A, Corbo MR, Antolak H, Dybka-Stepien K, Leszczewicz M, RelisonTintino S, Alexandrino de Souza VC, Sharifi-Rad J, Coutinho HDM, Martins N, Rodrigues CF (2019) Advances in chemical and biological methods to identify microorganisms-from past to present. Microorganisms 7(5):130CrossRef
3.
Zurück zum Zitat Shin DJ, Andini N, Hsieh K, Yang S, Wang TH (2019) Emerging analytical techniques for rapid pathogen identification and susceptibility testing. Annu Rev Anal Chem (Palo Alto Calif) 12(1):41–67CrossRef Shin DJ, Andini N, Hsieh K, Yang S, Wang TH (2019) Emerging analytical techniques for rapid pathogen identification and susceptibility testing. Annu Rev Anal Chem (Palo Alto Calif) 12(1):41–67CrossRef
4.
Zurück zum Zitat Angeletti S (2017) Matrix assisted laser desorption time of flight mass spectrometry (MALDI-TOF MS) in clinical microbiology. J Microbiol Methods 138:20–29CrossRef Angeletti S (2017) Matrix assisted laser desorption time of flight mass spectrometry (MALDI-TOF MS) in clinical microbiology. J Microbiol Methods 138:20–29CrossRef
5.
Zurück zum Zitat Kostrzewa M, Nagy E, Schrottner P, Pranada AB (2019) How MALDI-TOF mass spectrometry can aid the diagnosis of hard-to-identify pathogenic bacteria - the rare and the unknown. Expert Rev Mol Diagn 19(8):667–682CrossRef Kostrzewa M, Nagy E, Schrottner P, Pranada AB (2019) How MALDI-TOF mass spectrometry can aid the diagnosis of hard-to-identify pathogenic bacteria - the rare and the unknown. Expert Rev Mol Diagn 19(8):667–682CrossRef
6.
Zurück zum Zitat Byun JH, Yu AR, Kim MS, Lee K (2018) Performance of microflex LT biotyper and VITEK MS for routine identification of yeasts. Ann Lab Med 38(5):487–489CrossRef Byun JH, Yu AR, Kim MS, Lee K (2018) Performance of microflex LT biotyper and VITEK MS for routine identification of yeasts. Ann Lab Med 38(5):487–489CrossRef
7.
Zurück zum Zitat Fan WT, Qin TT, Bi RR, Kang HQ, Ma P, Gu B (2017) Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review. Eur J Clin Microbiol Infect Dis 36(6):1005–1012CrossRef Fan WT, Qin TT, Bi RR, Kang HQ, Ma P, Gu B (2017) Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review. Eur J Clin Microbiol Infect Dis 36(6):1005–1012CrossRef
8.
Zurück zum Zitat Garner O, Mochon A, Branda J, Burnham CA, Bythrow M, Ferraro M, Ginocchio C, Jennemann R, Manji R, Procop GW, Richter S, Rychert J, Sercia L, Westblade L, Lewinski M (2014) Multi-center evaluation of mass spectrometric identification of anaerobic bacteria using the VITEK(R) MS system. Clin Microbiol Infect 20(4):335–339CrossRef Garner O, Mochon A, Branda J, Burnham CA, Bythrow M, Ferraro M, Ginocchio C, Jennemann R, Manji R, Procop GW, Richter S, Rychert J, Sercia L, Westblade L, Lewinski M (2014) Multi-center evaluation of mass spectrometric identification of anaerobic bacteria using the VITEK(R) MS system. Clin Microbiol Infect 20(4):335–339CrossRef
9.
Zurück zum Zitat Lee W, Kim M, Yong D, Jeong SH, Lee K, Chong Y (2015) Evaluation of VITEK mass spectrometry (MS), a matrix-assisted laser desorption ionization time-of-flight MS system for identification of anaerobic bacteria. Ann Lab Med 35(1):69–75CrossRef Lee W, Kim M, Yong D, Jeong SH, Lee K, Chong Y (2015) Evaluation of VITEK mass spectrometry (MS), a matrix-assisted laser desorption ionization time-of-flight MS system for identification of anaerobic bacteria. Ann Lab Med 35(1):69–75CrossRef
10.
Zurück zum Zitat Plongla R, Panagea T, Pincus DH, Jones MC, Gilligan PH (2016) Identification of Burkholderia and uncommon glucose-nonfermenting gram-negative Bacilli isolated from patients with cystic fibrosis by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). J Clin Microbiol 54(12):3071–3072CrossRef Plongla R, Panagea T, Pincus DH, Jones MC, Gilligan PH (2016) Identification of Burkholderia and uncommon glucose-nonfermenting gram-negative Bacilli isolated from patients with cystic fibrosis by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). J Clin Microbiol 54(12):3071–3072CrossRef
11.
Zurück zum Zitat Porte L, Garcia P, Braun S, Ulloa MT, Lafourcade M, Montana A, Miranda C, Acosta-Jamett G, Weitzel T (2017) Head-to-head comparison of Microflex LT and Vitek MS systems for routine identification of microorganisms by MALDI-TOF mass spectrometry in Chile. PLoS ONE 12(5):e0177929CrossRef Porte L, Garcia P, Braun S, Ulloa MT, Lafourcade M, Montana A, Miranda C, Acosta-Jamett G, Weitzel T (2017) Head-to-head comparison of Microflex LT and Vitek MS systems for routine identification of microorganisms by MALDI-TOF mass spectrometry in Chile. PLoS ONE 12(5):e0177929CrossRef
12.
Zurück zum Zitat Ulger Toprak N, Alida CMV, Urban E, Wybo I, Justesen US, Jean-Pierre H, Morris T, Akgul O, Kulekci G, Soyletir G, Nagy E, Infections ESGfA, (2018) Performance of mass spectrometric identification of clinical Prevotella species using the VITEK MS system: a prospective multi-center study. Anaerobe 54:205–209CrossRef Ulger Toprak N, Alida CMV, Urban E, Wybo I, Justesen US, Jean-Pierre H, Morris T, Akgul O, Kulekci G, Soyletir G, Nagy E, Infections ESGfA, (2018) Performance of mass spectrometric identification of clinical Prevotella species using the VITEK MS system: a prospective multi-center study. Anaerobe 54:205–209CrossRef
13.
Zurück zum Zitat Wattal C, Oberoi JK, Goel N, Raveendran R, Khanna S (2017) Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) for rapid identification of microorganisms in the routine clinical microbiology laboratory. Eur J Clin Microbiol Infect Dis 36(5):807–812CrossRef Wattal C, Oberoi JK, Goel N, Raveendran R, Khanna S (2017) Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) for rapid identification of microorganisms in the routine clinical microbiology laboratory. Eur J Clin Microbiol Infect Dis 36(5):807–812CrossRef
14.
Zurück zum Zitat Hou TY, Chiang-Ni C, Teng SH (2019) Current status of MALDI-TOF mass spectrometry in clinical microbiology. J Food Drug Anal 27(2):404–414CrossRef Hou TY, Chiang-Ni C, Teng SH (2019) Current status of MALDI-TOF mass spectrometry in clinical microbiology. J Food Drug Anal 27(2):404–414CrossRef
15.
Zurück zum Zitat Dixon P, Davies P, Hollingworth W, Stoddart M, MacGowan A (2015) A systematic review of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry compared to routine microbiological methods for the time taken to identify microbial organisms from positive blood cultures. Eur J Clin Microbiol Infect Dis 34(5):863–876CrossRef Dixon P, Davies P, Hollingworth W, Stoddart M, MacGowan A (2015) A systematic review of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry compared to routine microbiological methods for the time taken to identify microbial organisms from positive blood cultures. Eur J Clin Microbiol Infect Dis 34(5):863–876CrossRef
16.
Zurück zum Zitat Deak E, Charlton CL, Bobenchik AM, Miller SA, Pollett S, McHardy IH, Wu MT, Garner OB (2015) Comparison of the Vitek MS and Bruker Microflex LT MALDI-TOF MS platforms for routine identification of commonly isolated bacteria and yeast in the clinical microbiology laboratory. Diagn Microbiol Infect Dis 81(1):27–33CrossRef Deak E, Charlton CL, Bobenchik AM, Miller SA, Pollett S, McHardy IH, Wu MT, Garner OB (2015) Comparison of the Vitek MS and Bruker Microflex LT MALDI-TOF MS platforms for routine identification of commonly isolated bacteria and yeast in the clinical microbiology laboratory. Diagn Microbiol Infect Dis 81(1):27–33CrossRef
Metadaten
Titel
A side-by-side comparison of the performance and time-and-motion data of VITEK MS
verfasst von
Marta Bardelli
Michela Padovani
Simona Fiorentini
Arnaldo Caruso
Deborah Yamamura
Mark Gaskin
Ali Jissam
Juan José González-López
M. Nieves Larrosa
Tomàs Pumarola
Anna Lassus
Barbara Louis
Nicolas Capron
Publikationsdatum
16.07.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Clinical Microbiology & Infectious Diseases / Ausgabe 8/2022
Print ISSN: 0934-9723
Elektronische ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-022-04472-x

Weitere Artikel der Ausgabe 8/2022

European Journal of Clinical Microbiology & Infectious Diseases 8/2022 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.