Skip to main content
Erschienen in: International Urology and Nephrology 9/2017

22.06.2017 | Urology - Original Paper

A urologic stethoscope? Urologist performed sonography using a pocket-size ultrasound device in the point-of-care setting

verfasst von: Arnon Lavi, Sharon Tzemah, Anan Hussein, Ibrahim Bishara, Nikolay Shcherbakov, Genady Zelichenko, Alon Mashiah, Michael Gross, Leonid Cherbinski, Ziv Neeman, Michael Cohen

Erschienen in: International Urology and Nephrology | Ausgabe 9/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Ultrasound is commonly used in urology. Technical advances with reduced size and cost led to diffusion of small ultrasound devices to many clinical settings. Even so, most ultrasound studies are performed by non-urologists. We aimed to evaluate the utility of a pocket-size ultrasound device (Vscan™ GE Healthcare) and the quality of urologist performed study.

Methods

Three consecutive studies were performed: (1) a urologist using the pocket ultrasound, (2) a sonographist using the pocket ultrasound, and (3) a sonographist using a standard ultrasound device. Thirty-six patients were evaluated with a basic urologic ultrasound study. An excepted deviation between studies was preset for numeric parameters and t test performed. Ordinal parameters were analyzed using Cohen’s kappa coefficient.

Results

Kidney length, renal pelvis length, renal cyst diameter, post-void residual and prostate volume (transabdominal) differences were found to be insignificant when comparing a urologist pocket ultrasound study to a sonographist standard ultrasound study (P = 0.15; P = 0.21; P = 0.81; P = 0.32; P = 0.07, respectively). Hydronpehrosis evaluation (none, mild, moderate and severe) and the presence of ureteral jet signs conferred a high inter-observer agreement when comparing the above studies using the Cohen’s kappa coefficient (K = 0.63; K = 0.62, respectively).

Conclusions

Urologist performed pocket ultrasound study is valid in evaluating the upper and lower urinary tract and is practical in many clinical scenarios. The urologic stethoscope is now becoming a reality within reach.
Literatur
1.
Zurück zum Zitat Donald I, Macvicar J, Brown TG (1958) Investigation of abdominal masses by pulsed ultrasound. Lancet (London, England) 1(7032):1188–1195CrossRef Donald I, Macvicar J, Brown TG (1958) Investigation of abdominal masses by pulsed ultrasound. Lancet (London, England) 1(7032):1188–1195CrossRef
2.
Zurück zum Zitat Suda I (1966) Ultrasonic diagnosis in gynecology and obstetrics. Nihon Sanka Fujinka Gakkai Zasshi 18(10):1197–1206PubMed Suda I (1966) Ultrasonic diagnosis in gynecology and obstetrics. Nihon Sanka Fujinka Gakkai Zasshi 18(10):1197–1206PubMed
3.
Zurück zum Zitat Mollenkopf M, Tait N (2013) Is it time to include point-of-care ultrasound in general surgery training? A review to stimulate discussion. ANZ J Surg 83(12):908–911CrossRefPubMed Mollenkopf M, Tait N (2013) Is it time to include point-of-care ultrasound in general surgery training? A review to stimulate discussion. ANZ J Surg 83(12):908–911CrossRefPubMed
4.
Zurück zum Zitat Kotagal M, Quiroga E, Ruffatto BJ, Adedipe AA, Backlund BH, Nathan R et al (2015) Impact of point-of-care ultrasound training on surgical residents’ confidence. J Surg Educ 72(4):e82–e87CrossRefPubMedPubMedCentral Kotagal M, Quiroga E, Ruffatto BJ, Adedipe AA, Backlund BH, Nathan R et al (2015) Impact of point-of-care ultrasound training on surgical residents’ confidence. J Surg Educ 72(4):e82–e87CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Leonard SA, Thomas R (1987) Diagnostic ultrasound in the urologist’s office. Urology 29(6):666–668CrossRefPubMed Leonard SA, Thomas R (1987) Diagnostic ultrasound in the urologist’s office. Urology 29(6):666–668CrossRefPubMed
6.
Zurück zum Zitat Reisman EM, Kennedy TJ, Roehrborn CG, McConnell JD (1991) A prospective study of urologist-performed sonographic evaluation of the urinary tract in patients with prostatism. J Urol 145(6):1186–1189CrossRefPubMed Reisman EM, Kennedy TJ, Roehrborn CG, McConnell JD (1991) A prospective study of urologist-performed sonographic evaluation of the urinary tract in patients with prostatism. J Urol 145(6):1186–1189CrossRefPubMed
7.
Zurück zum Zitat Bodner DR, Witcher M, Resnick MI (1990) Application of office ultrasound in the management of the spinal cord injury patient. J Urol 143(5):969–972CrossRefPubMed Bodner DR, Witcher M, Resnick MI (1990) Application of office ultrasound in the management of the spinal cord injury patient. J Urol 143(5):969–972CrossRefPubMed
8.
Zurück zum Zitat Acino S, Resnick MI (1988) Office urologic ultrasound. Urol Clin North Am 15(4):577–588PubMed Acino S, Resnick MI (1988) Office urologic ultrasound. Urol Clin North Am 15(4):577–588PubMed
9.
Zurück zum Zitat Surange RS, Jeygopal NS, Chowdhury SD, Sharma NK (2001) Bedside ultrasound: a useful tool for the on-call urologist? Int Urol Nephrol 32(4):591–596CrossRefPubMed Surange RS, Jeygopal NS, Chowdhury SD, Sharma NK (2001) Bedside ultrasound: a useful tool for the on-call urologist? Int Urol Nephrol 32(4):591–596CrossRefPubMed
10.
11.
Zurück zum Zitat Ruddox V, Stokke TM, Edvardsen T, Hjelmesæth J, Aune E, Bækkevar M et al (2013) The diagnostic accuracy of pocket-size cardiac ultrasound performed by unselected residents with minimal training. Int J Cardiovasc Imaging 29(8):1749–1757CrossRefPubMed Ruddox V, Stokke TM, Edvardsen T, Hjelmesæth J, Aune E, Bækkevar M et al (2013) The diagnostic accuracy of pocket-size cardiac ultrasound performed by unselected residents with minimal training. Int J Cardiovasc Imaging 29(8):1749–1757CrossRefPubMed
12.
Zurück zum Zitat Troyano Luque JM, Ferrer-Roca O, Barco-Marcellán MJ, Sabatel López R, Pérez-Medina T, Pérez-Lopez FR (2013) Modification of the hand-held Vscan ultrasound and verification of its performance for transvaginal applications. Ultrasonics 53(1):17–22CrossRefPubMed Troyano Luque JM, Ferrer-Roca O, Barco-Marcellán MJ, Sabatel López R, Pérez-Medina T, Pérez-Lopez FR (2013) Modification of the hand-held Vscan ultrasound and verification of its performance for transvaginal applications. Ultrasonics 53(1):17–22CrossRefPubMed
13.
Zurück zum Zitat Coşkun F, Akıncı E, Ceyhan MA, Sahin Kavaklı H (2011) Our new stethoscope in the emergency department: handheld ultrasound. Ulus Travma Acil Cerrahi Derg 17(6):488–492CrossRefPubMed Coşkun F, Akıncı E, Ceyhan MA, Sahin Kavaklı H (2011) Our new stethoscope in the emergency department: handheld ultrasound. Ulus Travma Acil Cerrahi Derg 17(6):488–492CrossRefPubMed
14.
Zurück zum Zitat Dijos M, Pucheux Y, Lafitte M, Réant P, Prevot A, Mignot A et al (2012) Fast track echo of abdominal aortic aneurysm using a real pocket-ultrasound device at bedside. Echocardiography 29(3):285–290CrossRefPubMed Dijos M, Pucheux Y, Lafitte M, Réant P, Prevot A, Mignot A et al (2012) Fast track echo of abdominal aortic aneurysm using a real pocket-ultrasound device at bedside. Echocardiography 29(3):285–290CrossRefPubMed
15.
Zurück zum Zitat Wang Y, Lu Z, Hu J, Wang X, Lu J, Hao Y et al (2013) Renal access by sonographer versus urologist during percutaneous nephrolithotomy. Urol J 10(4):1035–1039 Wang Y, Lu Z, Hu J, Wang X, Lu J, Hao Y et al (2013) Renal access by sonographer versus urologist during percutaneous nephrolithotomy. Urol J 10(4):1035–1039
16.
Zurück zum Zitat Barreiros AP, Cui XW, Ignee A, De Molo C, Pirri C, Dietrich CF (2014) EchoScopy in scanning abdominal diseases: initial clinical experience. Z Gastroenterol 52(3):269–275CrossRefPubMed Barreiros AP, Cui XW, Ignee A, De Molo C, Pirri C, Dietrich CF (2014) EchoScopy in scanning abdominal diseases: initial clinical experience. Z Gastroenterol 52(3):269–275CrossRefPubMed
17.
Zurück zum Zitat Stock KF, Klein B, Steubl D, Lersch C, Heemann U, Wagenpfeil S et al (2015) Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination. Abdom Imaging 40(7):2861–2866CrossRefPubMed Stock KF, Klein B, Steubl D, Lersch C, Heemann U, Wagenpfeil S et al (2015) Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination. Abdom Imaging 40(7):2861–2866CrossRefPubMed
18.
Zurück zum Zitat Daurat A, Choquet O, Bringuier S, Charbit J, Egan M, Capdevila X (2015) Diagnosis of postoperative urinary retention using a simplified ultrasound bladder measurement. Anesth Analg 120(5):1033–1038CrossRefPubMed Daurat A, Choquet O, Bringuier S, Charbit J, Egan M, Capdevila X (2015) Diagnosis of postoperative urinary retention using a simplified ultrasound bladder measurement. Anesth Analg 120(5):1033–1038CrossRefPubMed
Metadaten
Titel
A urologic stethoscope? Urologist performed sonography using a pocket-size ultrasound device in the point-of-care setting
verfasst von
Arnon Lavi
Sharon Tzemah
Anan Hussein
Ibrahim Bishara
Nikolay Shcherbakov
Genady Zelichenko
Alon Mashiah
Michael Gross
Leonid Cherbinski
Ziv Neeman
Michael Cohen
Publikationsdatum
22.06.2017
Verlag
Springer Netherlands
Erschienen in
International Urology and Nephrology / Ausgabe 9/2017
Print ISSN: 0301-1623
Elektronische ISSN: 1573-2584
DOI
https://doi.org/10.1007/s11255-017-1641-8

Weitere Artikel der Ausgabe 9/2017

International Urology and Nephrology 9/2017 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.