Aberrant right coronary artery in a grown up congenital cardiac patient, successfully treated 46 years earlier with a double Starr-Edwards silastic ball valve replacement: a case report

verfasst von: Andrea Ponsiglione, Gianrico Spagnuolo, Gabriella Spagnuolo, Arnaldo Stanzione, Carmela Nappi, Serena Dell’Aversana, Antonio Spagnuolo, Alberto Cuocolo, Massimo Imbriaco

Erschienen in: BMC Cardiovascular Disorders | Ausgabe 1/2020

Abstract

Background

The Starr-Edwards ball valve prosthesis was successfully introduced in 1961–62 and largely used for aortic and mitral valve replacement. Even if Starr-Edwards valves have been widely replaced in clinical practice by other mechanical valves, they define a standard concerning long-term durability.

Case presentation

We describe the case of a 55-year-old man referred to our Department to perform a cardiac computed tomography (CCT), to better evaluate a severe dilation of ascending aorta discovered at echocardiography. The patient had been surgically treated 46 years earlier to correct a supra-cristal type ventricular septal defect. Both mitral and aortic valves were replaced, respectively due to bacterial mitral endocarditis and a fibrous sub-valvular aortic stenosis. In addition, the right coronary artery (RCA) was found to arise from the left coronary sinus.

Conclusion

We report the longest lasting durability (46 years) of aortic and mitral Starr-Edwards valves successfully implanted in a patient simultaneously carrying a malignant anomalous origin of RCA.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
AAA
Ascending aortic aneurysm
CCT
Cardiac computed tomography
RCA
Right coronary artery

Background

The Starr-Edwards silastic ball valve prosthesis has been widely used for aortic and mitral valve replacement since its introduction in the 1960s [1, 2]. Since then, more than 200,000 Starr-Edwards silastic ball valves have been implanted worldwide [3, 4]. McGoon et al. reported that these prostheses implants were durable over a prolonged follow-up period, while thromboembolism remained a persistent problem [5]. Different kind of complications have been reported including haemolytic anaemia, valve dysfunction caused by granulomatous hyperplasia, degeneration or lipid infiltration of the silicon ball and wearing out of the cloth cover [6, 7].
We hereby describe the longest lasting durability (46 years) of aortic and mitral Starr-Edwards valves successfully implanted in a patient simultaneously carrying a malignant anomalous origin of RCA, incidentally discovered at surgery. This unique association has never been reported in the literature.

Case presentation

The patient is a 55-year-old man who underwent a previous surgery to correct a supra-cristal type ventricular septal defect 46 years earlier. During the surgical procedure, mitral valve resulted to be markedly involved in a destructive process, with ruptured chordae, as consequence of a bacterial endocarditis. Therefore, a size 2 silastic Starr-Edwards valve was implanted. Moreover, a localized fibrous subvalvular aortic stenosis, due to a ring was identified. The ring was excised, and a size 8 Starr-Edwards valve was implanted. In addition, RCA was found to arise from the left coronary sinus at the commissural attachment of the cusp. The patient was subsequently discharged with anticoagulant therapy with phenprocoumon, considering a target International Normalized Ratio of 4.0, without need of any surgical correction of the anomalously originating RCA from left coronary sinus.
Clinical follow-up was unremarkable, until the age of 55, when the patient underwent an echocardiography showing a severe dilation of ascending aorta. No trans-valvular leakage in the aortic position or mitral valvular regurgitation was identified; in addition, no thrombotic material was detectable at the prostheses site. Thus, the patient was scheduled for a cardiac computed tomography (CCT) for further diagnostic evaluation. CCT was performed using a 64 slices scanner (Aquilion, Toshiba) and allowed to appreciate both mitral and aortic silastic Starr-Edwards valve in correct position, confirming a significant dilation of the ascending aorta with a maximum transverse diameter of 6.2 cm (Fig. 1a-b). The anomalous origin of RCA from left coronary sinus, 1 cm above the origin of the left coronary artery and its course between the aortic root and main pulmonary artery were clearly identified (malignant variant) (Fig. 1a-b). A thrombus in the left atrial appendage was also detected (Fig. 1a-b). This patient has been living for 46 years with the Starr-Edwards mitral and aortic valves, in association with a rare coronary abnormality. Furthermore, the patient never showed any sign of prosthetic dysfunction, embolism, infection, periprosthetic leaks or hemolysis. Of note, the patient did not show any cardiac symptoms neither related to the right coronary abnormality nor to the ascending aortic aneurysm (AAA). Although medical treatments can slow the enlargement of AAA, the mainstay of prevention of aortic dissection is surgical repair when the aortic diameter expands to 5.5 cm or more [8]. In our case, the patient is still asymptomatic and refuses surgical correction of the AAA and is strictly monitored with CCT every 6 months; the patient is under medical treatment with anticoagulation therapy and anti-hypertensive drugs for mild hypertension.

Discussion and conclusions

The Starr-Edwards ball valve prosthesis was successfully introduced in 1961–62 and largely used for aortic and mitral valve replacement [4, 5]. It is one of the artificial valves with very long-term results [9]. Godje et al. reported a 30-year survival rate respectively of 19.9% in patients with aortic valve replacement and 22.6% in patients with mitral valve replacement [3]. Thromboembolism is a major factor contributing to the overall mortality and morbidity of patients who underwent valve replacement. In this setting, the necessity of long-term anticoagulation is controversial. Godje et al. found, in their patient’s population, that only 65.7% of patients with Starr-Edwards aortic valves received anticoagulation therapy, whereas patients with mitral valve replacement were treated with anticoagulant therapy in 90.7% of cases [3]. McGoon et al. found in a cohort of 336 patients that an adequate status of anticoagulation significantly reduced the risk of systemic embolism only in patients with a mitral valve prosthesis, suggesting a difference in the pathogenesis of emboli originating from mitral and aortic valve prostheses [5]. Nowadays, all surviving patients are treated with oral anticoagulation. Even if Starr-Edwards valves have been widely replaced in clinical practice by other mechanical valves, they define a standard concerning long-term durability. Abad et al. reported a case of a patient who lived almost 50 years after aortic valve replacement with a Starr-Edwards Caged-Ball Valve [10]. Yalcinkaya et al. described a still functioning Starr-Edwards mitral valve implanted 41 years before [11]. Starr et al. described that their longest-lived survivor had an original ball-valve prosthesis in the aortic position for 51.7 years, whereas the longest-functioning mitral valve lasted for 44.4 years [12]. Our patient has been living for 46 years with both Starr-Edwards mitral and aortic valves, without showing any sign of prosthetic dysfunction, embolism, infection, periprosthetic leaks or hemolysis.
The case presented is unique since our patient also shows a RCA anomalously originating from the left coronary sinus and coursing between the aortic root and the main pulmonary artery (malignant variant). Congenital anomalies of the coronary arteries are relatively uncommon, occurring in 0.2 to 1.2% of the population. These anatomic variants could be asymptomatic, but sometimes could represent an important cause of chest pain, determining hemodynamically significant abnormalities, until in worst cases sudden cardiac death. The anomalous right coronary origin may have inter-arterial (the most common one), retro-aortic, prepulmonic or septal (subpulmonic) course. The incidence of this variant is unknown. In particular, Yamanaka et al. reported an incidence of 0.1% in their population, who underwent coronary angiography [13]. Erol et al. reported a prevalence rate for RCA branching from the left coronary sinus of 0.43% in patients undergoing CCT [14]. The incidence of clinical events related to RCA abnormal origin, such as angina pectoris, myocardial infarction, or sudden cardiac death, is not known either and it is generally estimated from necropsy patients [15, 16]. Several explanations have been proposed for the association of this anatomic variant and clinical events including acute angulation at the origin, compression of the vessel between the aorta and pulmonary artery, slit like ostium and intramural proximal intussusception of the ectopic artery at the aortic root [17]. Nevertheless, the choice between surgical treatment or a conservative strategy is controversial [1820]. Proposed treatment options include revascularization, translocation of the RCA to the aorta, ostioplasty and bypass grafting [21]. Since our patient did not show any cardiac symptoms a conservative strategy was adopted.
In conclusion, we reported the longest lasting durability (46 years) described in the English literature of a double mitral-aortic Starr-Edwards silastic ball valve in association with an anomalous malignant origin of the RCA, coursing between the aortic root and the main pulmonary artery.

Acknowledgements

This paper also aims to make a tribute to an outstanding, pioneer and revolutionary cardiac surgeon, Dr. Donald Ross, who performed this surgery and to his brilliant and successful carrier.
Not applicable.
The patient gave written informed consent to publish this manuscript.

Competing interests

Not applicable.
We confirm that we have read BioMed Central’s guidance on competing interests and declare that none of the authors have any competing interests in the manuscript.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Starr A, Edwards ML. Mitral replacement: clinical experience with a ball-valve prosthesis. Ann Surg. 1961;154:726–40.CrossRef Starr A, Edwards ML. Mitral replacement: clinical experience with a ball-valve prosthesis. Ann Surg. 1961;154:726–40.CrossRef
2.
Zurück zum Zitat Starr A, Edwards ML, McCord CW. Aortic replacement: clinical experience with a semi-rigid ball valve prosthesis. Circulation. 1963;27:779–83.CrossRef Starr A, Edwards ML, McCord CW. Aortic replacement: clinical experience with a semi-rigid ball valve prosthesis. Circulation. 1963;27:779–83.CrossRef
3.
Zurück zum Zitat Godje OL, Fischlein T, Adelhard K, Nollert G, Klinner W, Reichart B. Thirty-year results of Starr-Edwards prostheses in the aortic and mitral position. Ann Thorac Surg. 1997;63:613–9.CrossRef Godje OL, Fischlein T, Adelhard K, Nollert G, Klinner W, Reichart B. Thirty-year results of Starr-Edwards prostheses in the aortic and mitral position. Ann Thorac Surg. 1997;63:613–9.CrossRef
5.
Zurück zum Zitat McGoon MD, Fuster V, McGoon DC, Pumphrey CW, Pluth JR, Elveback LR. Aortic and mitral valve incompetence: long-term follow up (10 to 19 years) of patients treated with the Starr-Edwards prosthesis. J Am Coll Cardiol. 1984;3:930–8.CrossRef McGoon MD, Fuster V, McGoon DC, Pumphrey CW, Pluth JR, Elveback LR. Aortic and mitral valve incompetence: long-term follow up (10 to 19 years) of patients treated with the Starr-Edwards prosthesis. J Am Coll Cardiol. 1984;3:930–8.CrossRef
6.
Zurück zum Zitat Grunkemeier GL, Starr A. Late ball variance with the model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management. J Thorac Cardiovasc Surg. 1986;91:918–23.CrossRef Grunkemeier GL, Starr A. Late ball variance with the model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management. J Thorac Cardiovasc Surg. 1986;91:918–23.CrossRef
7.
Zurück zum Zitat Koyano T, Ishilawa S, Ootaki A, Sakata K, Ootani Y, Takahashi T, et al. Reoperation for Starr-Edwards ball valve insufficiency 21 years after replacement. Jpn J Cardiovasc Surg. 1995;24:190–2.CrossRef Koyano T, Ishilawa S, Ootaki A, Sakata K, Ootani Y, Takahashi T, et al. Reoperation for Starr-Edwards ball valve insufficiency 21 years after replacement. Jpn J Cardiovasc Surg. 1995;24:190–2.CrossRef
8.
Zurück zum Zitat Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE Jr, et al. 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anaesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. Circulation. 2010;121:e266–369.PubMed Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE Jr, et al. 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anaesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. Circulation. 2010;121:e266–369.PubMed
9.
Zurück zum Zitat Tayama K, Akashi H, Tayama E, Fukunaga S, Kawara T, Kosuga K, et al. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation. Circ J. 2004 May;68:507–8.CrossRef Tayama K, Akashi H, Tayama E, Fukunaga S, Kawara T, Kosuga K, et al. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation. Circ J. 2004 May;68:507–8.CrossRef
10.
Zurück zum Zitat Abad C, Hernández-Ramírez JM, Caballero E. Patient lives almost 50 years after aortic valve replacement with a Starr-Edwards caged-ball valve. Tex Heart Inst J. 2016;43:562.CrossRef Abad C, Hernández-Ramírez JM, Caballero E. Patient lives almost 50 years after aortic valve replacement with a Starr-Edwards caged-ball valve. Tex Heart Inst J. 2016;43:562.CrossRef
11.
Zurück zum Zitat Yalcinkaya A, Diken AI, Dogan T, Memic K, Yilmaz S, Cagli K. Starr-Edwards caged-ball mitral valve: still working after 41 years. Tex Heart Inst J. 2016;43:96–7.CrossRef Yalcinkaya A, Diken AI, Dogan T, Memic K, Yilmaz S, Cagli K. Starr-Edwards caged-ball mitral valve: still working after 41 years. Tex Heart Inst J. 2016;43:96–7.CrossRef
12.
Zurück zum Zitat Starr A, Grunkemeier GL. Durability of the Starr-Edwards heart valve: early decisions led to successful results. Tex Heart Inst J. 2016;43:2–3.CrossRef Starr A, Grunkemeier GL. Durability of the Starr-Edwards heart valve: early decisions led to successful results. Tex Heart Inst J. 2016;43:2–3.CrossRef
13.
Zurück zum Zitat Yamanaka O, Hobbs RE. Coronary artery anomalies in 126,595 patients undergoing coronary angiography. Catheter Cardiovasc Diagn. 1990;21:28–40.CrossRef Yamanaka O, Hobbs RE. Coronary artery anomalies in 126,595 patients undergoing coronary angiography. Catheter Cardiovasc Diagn. 1990;21:28–40.CrossRef
14.
Zurück zum Zitat Erol C, Seker M. Coronary artery anomalies: the prevalence of origination, course, and termination anomalies of coronary arteries detected by 64-detector computed tomography coronary angiography. J Comput Assist Tomogr. 2011;35:618–24.CrossRef Erol C, Seker M. Coronary artery anomalies: the prevalence of origination, course, and termination anomalies of coronary arteries detected by 64-detector computed tomography coronary angiography. J Comput Assist Tomogr. 2011;35:618–24.CrossRef
15.
Zurück zum Zitat Frescura C, Basso C, Thiene G. Anomalous origin of coronary arteries and risk of sudden death: a study based on the autopsy population of congenital heart disease. Hum Pathol. 1998;29:689–95.CrossRef Frescura C, Basso C, Thiene G. Anomalous origin of coronary arteries and risk of sudden death: a study based on the autopsy population of congenital heart disease. Hum Pathol. 1998;29:689–95.CrossRef
16.
Zurück zum Zitat Roberts WC, Siegel RJ, Zipes DP. Origin of the right coronary artery from the left sinus of valsalva and its functional consequences: analysis of 10 necropsy patients. Am J Cardiol. 1982;49:863–8.CrossRef Roberts WC, Siegel RJ, Zipes DP. Origin of the right coronary artery from the left sinus of valsalva and its functional consequences: analysis of 10 necropsy patients. Am J Cardiol. 1982;49:863–8.CrossRef
17.
Zurück zum Zitat Angelini P, Velasco JA, Ott D, Khoshnevis GR. Anomalous coronary artery arising from the opposite sinus: descriptive features and pathophysiologic mechanisms, as documented by intravascular ultrasonography. J Invasive Cardiol. 2003;15:507–14.PubMed Angelini P, Velasco JA, Ott D, Khoshnevis GR. Anomalous coronary artery arising from the opposite sinus: descriptive features and pathophysiologic mechanisms, as documented by intravascular ultrasonography. J Invasive Cardiol. 2003;15:507–14.PubMed
18.
Zurück zum Zitat Satija B, Sanyal K, Katyayni K. Malignant anomalous right coronary artery detected by multidetector row computed tomography coronary angiography. J Cardiovasc Dis Res. 2012;3:40–2.CrossRef Satija B, Sanyal K, Katyayni K. Malignant anomalous right coronary artery detected by multidetector row computed tomography coronary angiography. J Cardiovasc Dis Res. 2012;3:40–2.CrossRef
19.
Zurück zum Zitat Yildirim E, Yuksel UC, Bugan B, Celik M, Gokoglan Y, Bozlar U. Malignant right coronary artery originating from left coronary sinus. Int J Cardiovasc Acad. 2016;2:49–51.CrossRef Yildirim E, Yuksel UC, Bugan B, Celik M, Gokoglan Y, Bozlar U. Malignant right coronary artery originating from left coronary sinus. Int J Cardiovasc Acad. 2016;2:49–51.CrossRef
20.
Zurück zum Zitat Lee BY. Anomalous right coronary artery from the left coronary sinus with an interarterial course: is it really dangerous? Korean Circ J. 2009;39:175–9.CrossRef Lee BY. Anomalous right coronary artery from the left coronary sinus with an interarterial course: is it really dangerous? Korean Circ J. 2009;39:175–9.CrossRef
21.
Zurück zum Zitat Ho JS, Strickman NE. Anomalous origin of the right coronary artery from the left coronary sinus: case report and literature review. Tex Heart Inst J. 2002;29:37–9.PubMedPubMedCentral Ho JS, Strickman NE. Anomalous origin of the right coronary artery from the left coronary sinus: case report and literature review. Tex Heart Inst J. 2002;29:37–9.PubMedPubMedCentral
Metadaten
Titel
Aberrant right coronary artery in a grown up congenital cardiac patient, successfully treated 46 years earlier with a double Starr-Edwards silastic ball valve replacement: a case report
verfasst von
Andrea Ponsiglione
Gianrico Spagnuolo
Gabriella Spagnuolo
Arnaldo Stanzione
Carmela Nappi
Serena Dell’Aversana
Antonio Spagnuolo
Alberto Cuocolo
Massimo Imbriaco
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
BMC Cardiovascular Disorders / Ausgabe 1/2020
Elektronische ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-020-01351-1

Weitere Artikel der Ausgabe 1/2020

BMC Cardiovascular Disorders 1/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.