Skip to main content
Erschienen in: Reproductive Biology and Endocrinology 1/2015

Open Access 01.12.2015 | Research

Absolute position versus relative position in embryo transfer: a randomized controlled trial

verfasst von: Hwang Kwon, Dong-Hee Choi, Eun-Kyung Kim

Erschienen in: Reproductive Biology and Endocrinology | Ausgabe 1/2015

Abstract

Background

Meta-analysis revealed that embryo placement 20 mm from the fundal endometrial surface resulted in higher pregnancy rate, ongoing pregnancy rate, and live birth rate compared with placement 10 mm from the fundal endometrial surface. Pregnancy and implantation rates according to relative position were higher when the catheter tip was positioned close to the middle of the endometrial cavity. The aim of the current study is to evaluate differences in implantation and pregnancy rates if the site of embryo transfer is 2 cm distance from the fundal endometrium (DFE) compared to the midpoint of the endometrial cavity length (ECL).

Methods

Patients were randomized to one of two groups: in group A (n = 98, 98 IVF-ET cycles), the embryo transfer catheter tip was positioned 2 cm DFE, while that in group B (n = 97, 97 IVF-ET cycles) was positioned at the midpoint of the ECL. We compared pregnancy outcomes of implantation rate, chemical pregnancy rate, clinical pregnancy rate, ongoing pregnancy rate, ectopic pregnancy rate, and miscarriage rate in the two groups.

Results

Analysis of implantation rate (19.5 ± 27.7 vs. 21.7 ± 32.6; p = 0.6), chemical pregnancy rate (51 % vs. 50.5 %; p = 0.94), clinical pregnancy rate (35.7 % vs. 38.1 %; p = 0.73), ongoing pregnancy rate (31.6 % vs. 30.9 %; p = 0.92), ectopic pregnancy rate (8.6 % vs. 2.7 %; p = 0.35), and miscarriage rate (11.4 % vs. 16.2 %; 0.74) revealed comparable results for both groups.

Conclusions

Implantation and pregnancy rates were not influenced by the site of the ET catheter tip being 2 cm DFE compared to at the midpoint of the ECL.

Trial Registration

Hinweise

Completing interest

The authors declare that they have no competing interests.

Authors’ contribution

HK designed the study and wrote the manuscript. EK analyzed the data and performed statistics analysis. DC conceived of the study and helped to draft the manuscript. All authors read and approved the final manuscript.

Background

Embryo transfer is one of the most important factors affecting the rate of successful pregnancy in IVF-ET. Variables in ET such as removal of cervical mucus [1, 2], sonoguidance [36], catheter type [713], catheter loading technique [1416], presence of blood on the catheter tip [17], bacterial contamination [18, 19], and site of embryo deposition [2022] are all determinants of a successful pregnancy.
There has been debate regarding which area within the endometrial cavity is ideal for embryo placement in order to obtain the highest pregnancy rate. Various studies regarding the relationship between embryo transfer site and pregnancy outcome have been divided analysis into two categories: absolute position according to distance from the fundal endometrium (DFE) and relative position according to endometrial cavity length (ECL). It is not easy to determine whether the embryo deposition site should be chosen based on absolute position from the fundal endometrium or by relative position according to endometrial cavity length. In a previous randomized controlled trial (RCT) on absolute position, pregnancy rate was significantly higher when the embryo was deposited 20 mm caudal to the fundus compared to when it was deposited 10 mm caudal to the fundus (60 % vs. 39.3 %) [20]. A meta-analysis found that embryo placement 20 mm from the fundal endometrial surface resulted in higher pregnancy rate, ongoing pregnancy rate, and live birth rate compared with placement 10 mm from the fundal endometrial surface [23]. One research group reported that pregnancy and implantation rates did not vary according to the distance between the catheter tip and fundal endometrium (group 1: 10–15 mm, group 2: 16–20 mm, and group 3: ≥21 mm), but that pregnancy and implantation rates according to the relative position of the catheter tip in endometrial cavity were higher when the catheter tip was positioned close to the middle of the endometrial cavity (group 1: upper 40 % ECL, group 2: upper 40 % to midpoint ECL, group 3: from the midpoint to lower 40 % ECL, and group 4: lower 40 % ECL) [22].
Although discrepancies exist regarding pregnancy rates according to the absolute or relative position of the catheter tip, a 2-cm DFE was considered the reference point for absolute position because that point was associated with a higher pregnancy rate in a meta-analysis [23]. As observed pregnancy and implantation rates were higher in the midpoint ECL in a RCT evaluating relative position, midpoint ECL was considered the reference point for relative position. The aim of this current prospective RCT is to compare the differences in implantation and pregnancy rates at an absolute position 2 cm from the fundal endometrium and a relative position at the midpoint of the endometrial cavity.

Methods

This randomized controlled trial was approved by the Institutional Review Board at our hospital. A total of 197 patients were enrolled in the IVF-ET (ICSI) program at the CHA Fertility Center (CHA University, Seongnam, Korea) between July 2012 and December 2014. All patients provided written informed consent. The study was registered under ISRCTN registry number (ISRCTN 15972342).

Sample size and randomization

The null hypothesis is that the rates for groups A and B are equal. The sample size was calculated to prevent type II errors. In previous articles, pregnancy rates at 2 cm distance from fundal endometrium [20] and the central area of the endometrial cavity [22] were 60 % and 36.7 %, respectively. Based on these differences, 84 cases in each group would be needed with a two-sided alpha level of 0.05 and a beta level of 0.20 (80 % power). This sample size calculation was done so that the null hypothesis was not accepted with a probability of 80 %. Thus, the target number of subjects for each group was 100 (a total of 200) to allow dropouts. Randomization was performed using a computer-generated random number list in blocks of four. An allocation list was sealed in an envelope and the physician transferring embryos opened the envelope just before ET.

Study design

197 patients were randomized to one of two groups: group A or group B. In group A (n = 100), the embryo transfer catheter tip was positioned 2 cm from the fundal endometrium. In group B (n = 97), the embryo transfer catheter tip was positioned at the midpoint of the endometrial cavity length, between the internal os of the uterine cervix and the fundal endometrium. The current study included only fresh embryo transfer cycles. Two patients were excluded from group A, including one patient in which all embryos were frozen for prevention of OHSS and the other patient in which embryos were not transferred by the same physician due to the absence of a physician (Fig. 1).

Stimulation protocol and oocyte retrieval

All patients were pretreated with GnRH agonist (Lorelin®; Dongkook, Korea) 0.5 mg/day from 10 days prior to the start of menstruation until day 2 of the next menstrual cycle for suppression of the pituitary gland. The patients’ ovaries were stimulated with a combination of recombinant follicle-stimulating hormone (FSH, subcutaneous) and human menopausal gonadotropin (hMG, intramuscular) from day 3 of the menstrual cycle until one day before hCG administration. hCG (Ovidrel®; Merck-Serono, Italy) was administered when at least two follicles with an average diameter ≥18 mm were observed on ultrasonography. Oocytes were retrieved 35 hours after hCG injection and were subsequently fertilized by IVF or ICSI. On day 2 or 3, all embryos were evaluated for cell number and morphology. Each embryo transferred was evaluated for blastomere size and fragmentation. Embryos were graded as follows. Those with equal blastomere size and no fragmentation were considered Grade 1; those with blastomeres of equal size with slight fragmentation (<20 %) were Grade 2; those with blastomeres of unequal size but no fragmentation were Grade 3; those with blastomeres of equal or unequal size and moderate fragmentation (20 %–50 %) were Grade 4; and those with unrecognizable blastomeres and severe fragmentation (>50 %) were Grade 5 [24]. The embryos were transferred on postretrieval day 2 or 3.

Embryo transfer

After bladder filling, patients were placed in the lithotomy position, and the cervix was visualized using a speculum. The vagina and exocervix were cleaned with sterile gauze, and endocervical mucus was removed with a cotton swab. We measured the distance between the internal os of the cervix and the fundal endometrium using 5 MHz transabdominal ultrasonography (Aloka SSD-4000; Hitachi Aloka Medical Ltd., Japan) in both groups of patients. This distance was measured only once and was considered the endometrial cavity length (ECL). The ECL and the midpoint of the ECL were recorded. A Sydney-Cook catheter external guide was inserted into the endometrial cavity through the endocervical canal. We measured the distance from the tip of the external guide to the fundal endometrium only once and estimated the position of the internal catheter tip loaded with the embryos. After the internal catheter tip passed through the external guide and was positioned 2 cm from the fundal endometrium (DFE) in group A and at the midpoint of the ECL in group B, the embryos were expelled. The catheter was immediately removed and examined under a stereomicroscope to determine whether the embryos remained in the catheter tip. It was recommended that patients remain supine in bed for 2 hours after emptying their bladder [25]. All embryo transfers were performed by the same physician.
Micronized progesterone (Utrogestan® 200 mg Vaginal Capsule; Capsugel, France) was inserted into the vagina three times per day beginning on the day of oocyte retrieval for luteal support. Pregnancy was determined by serum β hCG level 13 days after embryo transfer.

Outcome measures

To determine the difference in general characteristics of patients, the following factors were compared in groups A and B: age, etiology of infertility, body mass index (BMI), AMH, antral follicle count (AFC), and duration of infertility. Also, for comparison of ovarian stimulation, oocyte retrieval, and IVF outcome in groups A and B, the following factors were recorded: E2 and endometrial thickness on the day of hCG administration, number of oocytes retrieved, number of oocytes in metaphase II, fertilization rate, fertilization method, number of embryos transferred, good quality embryos (%, Grade 1 or 2 embryos according to the embryo grading system described above) [24], and endometrial cavity length. We analyzed pregnancy outcomes including implantation rate, chemical pregnancy rate, clinical pregnancy rate, ongoing pregnancy rate, ectopic pregnancy rate, and miscarriage rate. The implantation rate was defined as the number of gestational sacs divided by the number of embryos transferred. Clinical pregnancy was defined as the presence of a gestational sac with fetal heart activity. Ongoing pregnancy was defined as the presence of at least one fetal heart pulsation on ultrasound beyond 12 weeks.

Statistics

SPSS version 22 was used for statistical analysis. Data are expressed as mean ± SD or percentage, as appropriate. Student’s t-test, χ 2 test, and Fisher’s exact test were used to determine statistical significance. A p-value <0.05 was considered statistically significant.

Results

The groups were not significantly different with respect to age, etiology of infertility, BMI, AMH, or AFC. However, there was a significant difference in duration of infertility (p = 0.025): 3.9 ± 2.1 years in group A compared with 4.8 ± 3.1 years in group B (Table 1). There were no significant differences between groups A and B with regard to E2 and endometrial thickness on the day of hCG administration, number of oocytes retrieved, number of oocytes in metaphase II, fertilization rate, fertilization method, number of embryos transferred, or percentage of good quality embryos. The two groups were also not significantly different with regard to endometrial cavity length (4.8 ± 0.7 vs. 4.8 ± 0.8; p = 0.94) or the difference between midpoint and 2-cm DFE (0.4 ± 0.3 vs. 0.4 ± 0.4; p = 0.98) (Table 2). Mean DFE was 2 cm in group A and 2.38 ± 0.4 in group B. Analysis of implantation rate (19.5 ± 27.7 vs. 21.7 ± 32.6; p = 0.6), chemical pregnancy rate (51 % vs. 50.5 %; p = 0.94), clinical pregnancy rate (35.7 % vs. 38.1 %; p = 0.73), ongoing pregnancy rate (31.6 % vs. 30.9 %; p = 0.92), ectopic pregnancy rate (8.6 % vs. 2.7 %; p = 0.35), and miscarriage rate (11.4 % vs. 16.2 %; 0.74) revealed comparable results for both groups (Table 3).
Table 1
General characteristics of all patients studied
 
Group A:DFE 2 cm
Group B: midpoint of ECL
p value
Patients (n)
98
97
 
cycles (n)
98
97
 
Age (years) (±SD)
34.1 ± 3.8
34.1 ± 3.4
0.87
Etiology
  
0.55
Tubal factor
19
21
 
Male factor
8
12
 
POR
7
4
 
Hypo-Hypo
1
0
 
POR + tubal
0
1
 
uterine
0
1
 
Unexplained
63
58
 
BMI (Kg/m2) (±SD)
21 ± 2.4
21.4 ± 3.2
0.33
AMH (ng/ml) (±SD)
3.5 ± 2.9
3.6 ± 3.2
0.67
AFC (±SD)
20.6 ± 8.6
21.5 ± 8.0
0.44
Duration of infertility (yrs,) (±SD)
3.9 ± 2.1
4.8 ± 3.1
0.025
DFE = distance from fundal endometrium, ECL = endometrial cavity length
POR = poor ovarian response, Hypo-Hypo = Hypogonadotropic hypogonadism
AFC = antral follicle count
Table 2
Ovarian stimulation, oocyte retrieval, and IVF outcome of all patients studied
 
Group A: DFE 2 cm
Group B: midpoint of ECL
p value
E2 on hCG day (pg/mL) (±SD)
2740.9 ± 1413.3
2787.7 ± 1544.4
0.83
Endometrial thickness on hCG day (mm) (±SD)
10.4 ± 2.2
10.1 ± 2.2
0.3
No. of oocyte retrieval (±SD)
12.5 ± 6.5
13.4 ± 6.8
0.32
No. of oocytes in metaphase II (±SD)
7.3 ± 4.9
7.9 ± 5.0
0.41
Fertilization rate (%) (±SD)
68.6 ± 18.7
68.3 ± 17.4
0.92
Fertilization method
  
0.61
Conventional IVF
9
8
 
ICSI
51
44
 
Split IVF-ICSI
38
44
 
No. of embyos transferred (±SD)
2.8 ± 0.8
2.8 ± 0.7
0.78
Good quality embyos (%) (±SD)
70.7 ± 34.8
76.7 ± 29.7
0.19
ECL (cm) (±SD)
4.8 ± 0.7
4.8 ± 0.8
0.94
Difference between midpoint and DFE2cm (±SD)
0.4 ± 0.3
0.4 ± 0.4
0.98
DFE = distance from fundal endometrium, ECL = endometrial cavity length
Table 3
Implantation rates, pregnancy rates, and outcome at gestation of all patients studied
 
Group A: DFE2cm
Group B: midpoint of ECL
p value
Implantation rates (%)
19.5 ± 27.7
21.7 ± 32.6
0.6
Chemical pregnancy rates
51.0 %(50/98)
50.5 %(49/97)
0.94
Clinical pregnancy rate
35.7 %(35/98)
38.1 %(37/97)
0.73
Ongoing pregnancy rates
31.6 %(31/98)
30.9 %(30/97)
0.92
Ectopic pregnancy
8.6 %(3/35)
2.7 %(1/37)
0.35
Miscarriage rate
11.4 %(4/35)
16.2 %(6/37)
0.74
Mole
0 %
2.8 %(1/37)
1
DFE = distance from fundal endometrium, ECL = endometrial cavity length

Discussion

This randomized controlled study demonstrated that implantation and pregnancy rates of patients in whom the embryo transfer catheter tip was positioned 2 cm from the fundal endometrium were comparable to those of patients in whom the embryo transfer catheter tip was positioned at the midpoint of the endometrial cavity.
One study group observed position of 3 ~ 6 mm early gestational sac (G sac) in the endometrial cavity after spontaneous pregnancy using three-dimensional ultrasound. When the uterine cavity was divided into three portions (upper, middle, and lower), most G sacs were found in the upper region (89.1 %) [26]. In another study, the location of the G sac was determined via three-dimensional ultrasound after embryo transfer in IVF-ET and 84.4 % of the G sacs were found in the fundal area where embryos were initially transferred. These results emphasize the importance of embryo transfer [27].
Endometrial blood flow is especially rich around the uterotubal junction outside of the fundal areas. When the G sac is observed daily, it develops near the uterotubal junction and fundus, gradually moving towards the central portion of uterine body [28]. Embryos are apt to implant at a site where endometrial blood flow is rich. Although little research has been done on factors related pregnancy and implantation rates according to deposition of embryos during transfer, the difference in blood flow in the endometrial cavity may play a role.
Many initial reports stated that a site near the fundus is optimal for embryo transfer [29, 30]. However, subsequent studies reported that fundal irritation due to high replacement cause fundal contraction and adversely affect pregnancy rates [3133].
One retrospective study suggested that, for every additional millimeter the embryos are deposited away from the fundus, the odds of clinical pregnancy increase by 11 % [34]. Another retrospective study reported a higher pregnancy rate with embryo deposition >10 mm to <20 mm from the fundus [35]. In a previous RCT, higher pregnancy and implantation rates were achieved when the tip was placed between 5 and 15 mm DFE compared with >15 mm DFE [36]. Another RCT reported that an embryo transfer catheter tip positioned between 10 and 15 mm from the fundus achieved higher clinical pregnancy rate than an embryo catheter tip positioned ≤10 mm from the fundus [37]. When patients were classified into three groups including DFE of 10 mm, 15 mm, and 20 mm in an earlier RCT, DFE of 20 mm showed a significantly higher clinical pregnancy rate than DFE of 10 mm (60 % vs. 39.3 %) [20].
Consistent results were not observed in the above RCT studies with respect to absolute position from the fundal endometrium. However, a meta-analysis of three articles [20, 21, 38] using the Mantel − Haenszel method and utilizing the fixed-effects model revealed that clinical pregnancy rate, ongoing pregnancy rate, and live birth rate were significantly higher for a 20 mm versus 10 mm distance from the fundal endometrium [23]. Based on this meta-analysis, a 2-cm DFE was considered the optimal site of absolute position in the current study.
One prospective cohort study divided patients into two groups: a fundal group (embryos were deposited within 0.5-1.0 cm of the uterine fundus) and a lower-to-middle group (embryos were deposited at the central portion of the ECL to the lower third of the ECL). Comparison of these two groups revealed that clinical pregnancy rate, implantation rate, and birth rate were significantly higher in the lower-to-middle segment ET group compared with the fundal ET group [39]. Another RCT showed that placing embryos in the upper half of the uterine cavity did not improve pregnancy rate compared with that of embryos placed in the lower half [21]. These research group randomized patients into three groups according to the distance between the fundal endometrial surface and the catheter tip (group 1: 10–15 mm, group 2: 16–20 mm, group 3: ≥21 mm) and compared the pregnancy and implantation rates between groups. They also randomly assigned patients to four groups according to the relative position in the endometrial cavity (group 1: <40 %, group 2: 41-50 %, group 3: 51-60 %, group 4: ≥61 %) and compared the pregnancy and implantation rates between groups. Pregnancy and implantation rates according to absolute position were not significantly different, but pregnancy and implantation rates according to relative position were higher when the catheter tip was positioned close to the middle of the endometrial cavity [22]. When we analyzed these three studies with respect to relative position of embryo transfer, the optimal site for relative positioning of the embryo transfer was the midpoint of the ECL.
The current study was designed to compare absolute position (2 cm DFE) with relative position (midpoint of the ECL) of embryo transfer. In comparing general characteristics of all patients studied, the duration of infertility in group B (midpoint of the ECL) was significantly higher than that of group A (2 cm DFE). However, this difference in duration of infertility did not seem to correlate with dissimilarity in general characteristics, since there were no differences between groups in age, BMI, etiology of infertility, or ovarian reserve indicators (AMH, AFC). There were also no differences in implantation, clinical pregnancy, or ongoing pregnancy rates between the two groups. The mean difference between the midpoint (group A) and 2-cm DFE (group B) was only 4 mm. In most other reports, embryo transfer depth was classified in 5-mm increments from the fundal endometrium [22, 35, 37]. Thus, a difference of less than 5 mm is not considered to affect pregnancy outcomes. Overall, the minimal difference in DFE between groups A and B resulted in no differences in implantation, clinical pregnancy, or ongoing pregnancy rate.
Therefore, patients with a greater than 0.5 cm difference between the midpoint of the ECL and 2 cm DFE (in other words, an ECL ≥5 cm or ≤3 cm) were classified separately. However, there were no patients with an ECL ≤ 3 cm. A total of 37 women in group A and 34 women in group B had an ECL ≥5 cm. The mean ECL of patients with an ECL ≥5 cm was 5.5 ± 0.5 cm in group A and 5.6 ± 0.6 cm in group B (p = 0.41). The ongoing pregnancy rate for group A (DFE 2 cm) was significantly higher than that of group B (midpoint of ECL) (43.2 % vs. 20.6 %; p = 0.002) in women with an ECL ≥5 cm. In cases in which the ECL was longer than 5 cm, our data suggest that positioning the embryo transfer catheter tip more than 2.5 cm from the fundal endometrium compared with 2 cm from the fundal endometrium worsens pregnancy outcome.
Although embryo deposition at a relative 50 % ECL may be the best approach in most patients, optimal pregnancy rates in patients with an ECL ≥5 cm are obtained when embryos are placed at a 2-cm DFE.

Conclusions

In conclusion, implantation and pregnancy rates were not influenced by the site of the ET catheter tip being 2 cm DFE compared to at the midpoint of the ECL. Since the midpoint ECL in most patients of the relative position group is near the 2-cm DFE, there was no difference in pregnancy outcomes between groups. However, if the ECL is longer than 5 cm, positioning at the midpoint of the ECL was not advantageous. Although the number of patients with an ECL ≥5 cm was small, placing the embryo catheter tip more than 2.5 cm from the fundal endometrium decreased pregnancy rates in patients with an ECL ≥5 cm. Further large-scale studies are needed in patients with an ECL ≥5 cm.

Acknowledgements

We thank Ji-Sook Ha for helping obtain IRB approval and help in performing the study. This manuscript was edited by editors at eworldediting.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​4.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Completing interest

The authors declare that they have no competing interests.

Authors’ contribution

HK designed the study and wrote the manuscript. EK analyzed the data and performed statistics analysis. DC conceived of the study and helped to draft the manuscript. All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Eskandar MA, Abou-Setta AM, El-Amin M, Almushait MA, Sobande AA. Removal of cervical mucus prior to embryo transfer improves pregnancy rates in women undergoing assisted reproduction. Reprod Biomed Online. 2007;14:308–13.PubMedCrossRef Eskandar MA, Abou-Setta AM, El-Amin M, Almushait MA, Sobande AA. Removal of cervical mucus prior to embryo transfer improves pregnancy rates in women undergoing assisted reproduction. Reprod Biomed Online. 2007;14:308–13.PubMedCrossRef
2.
Zurück zum Zitat Visschers BA, Bots RS, Peeters MF, Mol BW, van Dessel HJ. Removal of cervical mucus: effect on pregnancy rates in IVF/ICSI. Reprod Biomed Online. 2007;15:310–5.PubMedCrossRef Visschers BA, Bots RS, Peeters MF, Mol BW, van Dessel HJ. Removal of cervical mucus: effect on pregnancy rates in IVF/ICSI. Reprod Biomed Online. 2007;15:310–5.PubMedCrossRef
3.
Zurück zum Zitat Strickler RC, Christianson C, Crane JP, Curato A, Knight AB, Yang V. Ultrasound guidance for human embryo transfer. Fertil Steril. 1985;43:54–61.PubMed Strickler RC, Christianson C, Crane JP, Curato A, Knight AB, Yang V. Ultrasound guidance for human embryo transfer. Fertil Steril. 1985;43:54–61.PubMed
4.
Zurück zum Zitat García-Velasco JA, Isaza V, Martinez-Salazar J, Landazábal A, Requena A, Remohí J, et al. Transabdominal ultrasound-guided embryo transfer does not increase pregnancy rates in oocyte recipients. Fertil Steril. 2002;78:534–9.PubMedCrossRef García-Velasco JA, Isaza V, Martinez-Salazar J, Landazábal A, Requena A, Remohí J, et al. Transabdominal ultrasound-guided embryo transfer does not increase pregnancy rates in oocyte recipients. Fertil Steril. 2002;78:534–9.PubMedCrossRef
5.
Zurück zum Zitat Buckett WM. A meta-analysis of ultrasound-guided versus clinical touch embryo transfer. Fertil Steril. 2003;80:1037–41.PubMedCrossRef Buckett WM. A meta-analysis of ultrasound-guided versus clinical touch embryo transfer. Fertil Steril. 2003;80:1037–41.PubMedCrossRef
6.
Zurück zum Zitat Abou-Setta AM, Mansour RT, Al-Inany HG, Aboulghar MM, Aboulghar MA, Serour GI. Among women undergoing embryo transfer, is the probability of pregnancy and live birth improved with ultrasound guidance over clinical touch alone? A systemic review and meta-analysis of prospective randomized trials. Fertil Steril. 2007;88:333–41.PubMedCrossRef Abou-Setta AM, Mansour RT, Al-Inany HG, Aboulghar MM, Aboulghar MA, Serour GI. Among women undergoing embryo transfer, is the probability of pregnancy and live birth improved with ultrasound guidance over clinical touch alone? A systemic review and meta-analysis of prospective randomized trials. Fertil Steril. 2007;88:333–41.PubMedCrossRef
7.
Zurück zum Zitat Abou-Setta AM, Al-Inany HG, Mansour RT, Serour GI, Aboulghar MA. Soft versus firm embryo transfer catheters for assisted reproduction: a systematic review and meta-analysis. Hum Reprod. 2005;20:3114–21.PubMedCrossRef Abou-Setta AM, Al-Inany HG, Mansour RT, Serour GI, Aboulghar MA. Soft versus firm embryo transfer catheters for assisted reproduction: a systematic review and meta-analysis. Hum Reprod. 2005;20:3114–21.PubMedCrossRef
8.
Zurück zum Zitat Buckett WM. A review and meta-analysis of prospective trials comparing different catheters used for embryo transfer. Fertil Steril. 2006;85:728–34.PubMedCrossRef Buckett WM. A review and meta-analysis of prospective trials comparing different catheters used for embryo transfer. Fertil Steril. 2006;85:728–34.PubMedCrossRef
9.
Zurück zum Zitat al-Shawaf T, Dave R, Harper J, Linehan D, Riley P, Craft I. Transfer of embryos into the uterus: how much do technical factors affect pregnancy rates? J Assist Reprod Genet. 1993;10:31–6.PubMedCrossRef al-Shawaf T, Dave R, Harper J, Linehan D, Riley P, Craft I. Transfer of embryos into the uterus: how much do technical factors affect pregnancy rates? J Assist Reprod Genet. 1993;10:31–6.PubMedCrossRef
10.
Zurück zum Zitat Ghazzawi IM, Al-Hasani S, Karaki R, Souso S. Transfer technique and catheter choice influence the incidence of transcervical embryo expulsion and the outcome of IVF. Hum Reprod. 1999;14:677–82.PubMedCrossRef Ghazzawi IM, Al-Hasani S, Karaki R, Souso S. Transfer technique and catheter choice influence the incidence of transcervical embryo expulsion and the outcome of IVF. Hum Reprod. 1999;14:677–82.PubMedCrossRef
11.
Zurück zum Zitat Urman B, Aksoy S, Alatas C, Mercan R, Nuhoglu A, Isiklar A, et al. Comparing two embryo transfer catheters. Use of a trial transfer to determine the catheter applied. J Reprod Med. 2000;45:135–8.PubMed Urman B, Aksoy S, Alatas C, Mercan R, Nuhoglu A, Isiklar A, et al. Comparing two embryo transfer catheters. Use of a trial transfer to determine the catheter applied. J Reprod Med. 2000;45:135–8.PubMed
12.
Zurück zum Zitat Burke LM, Davenport AT, Russell GB, Deaton JL. Predictors of success after embryo transfer: experience from a single provider. Am J Obstet Gynecol. 2000;182:1001–4.PubMedCrossRef Burke LM, Davenport AT, Russell GB, Deaton JL. Predictors of success after embryo transfer: experience from a single provider. Am J Obstet Gynecol. 2000;182:1001–4.PubMedCrossRef
13.
Zurück zum Zitat Saldeen P, Abou-Setta AM, Bergh T, Sundström P, Holte J. A prospective randomized controlled trial comparing two embryo transfer catheters in an ART program. Fertil Steril. 2008;90:599–603.PubMedCrossRef Saldeen P, Abou-Setta AM, Bergh T, Sundström P, Holte J. A prospective randomized controlled trial comparing two embryo transfer catheters in an ART program. Fertil Steril. 2008;90:599–603.PubMedCrossRef
14.
Zurück zum Zitat Matorras R, Mendoza R, Expósito A, Rodriguez-Escudero FJ. Influence of the time interval between embryo catheter loading and discharging on the success of IVF. Hum Reprod. 2004;19:2027–30.PubMedCrossRef Matorras R, Mendoza R, Expósito A, Rodriguez-Escudero FJ. Influence of the time interval between embryo catheter loading and discharging on the success of IVF. Hum Reprod. 2004;19:2027–30.PubMedCrossRef
15.
Zurück zum Zitat Lesny P, Killick SR, Robinson J, Raven G, Maguiness SD. Junctional zone contractions and embryo transfer: is it safe to use a tenaculum? Hum Reprod. 1999;14:2367–70.PubMedCrossRef Lesny P, Killick SR, Robinson J, Raven G, Maguiness SD. Junctional zone contractions and embryo transfer: is it safe to use a tenaculum? Hum Reprod. 1999;14:2367–70.PubMedCrossRef
16.
Zurück zum Zitat Martínez F, Coroleu B, Parriego M, Carreras O, Belil I, Parera N, et al. Ultrasound-guided embryo transfer: immediate withdrawal of the catheter versus a 30 second wait. Hum Reprod. 2001;16:871–4.PubMedCrossRef Martínez F, Coroleu B, Parriego M, Carreras O, Belil I, Parera N, et al. Ultrasound-guided embryo transfer: immediate withdrawal of the catheter versus a 30 second wait. Hum Reprod. 2001;16:871–4.PubMedCrossRef
17.
Zurück zum Zitat Goudas VT, Hammitt DG, Damario MA, Session DR, Singh AP, Dumesic DA. Blood on the embryo transfer catheter is associated with decreased rates of embryo implantation and clinical pregnancy with the use of in vitro fertilization-embryo transfer. Fertil Steril. 1998;70:878–82.PubMedCrossRef Goudas VT, Hammitt DG, Damario MA, Session DR, Singh AP, Dumesic DA. Blood on the embryo transfer catheter is associated with decreased rates of embryo implantation and clinical pregnancy with the use of in vitro fertilization-embryo transfer. Fertil Steril. 1998;70:878–82.PubMedCrossRef
18.
Zurück zum Zitat Egbase PE, al-Sharhan M, al-Othman S, al-Mutawa M, Udo EE, Grudzinskas JG. Incidence of microbial growth from the tip of the embryo transfer catheter after embryo transfer in relation to clinical pregnancy rate following in-vitro fertilization and embryo transfer. Hum Reprod. 1996;11:1687–9.PubMedCrossRef Egbase PE, al-Sharhan M, al-Othman S, al-Mutawa M, Udo EE, Grudzinskas JG. Incidence of microbial growth from the tip of the embryo transfer catheter after embryo transfer in relation to clinical pregnancy rate following in-vitro fertilization and embryo transfer. Hum Reprod. 1996;11:1687–9.PubMedCrossRef
19.
Zurück zum Zitat Moore DE, Soules MR, Klein NA, Fujimoto VY, Agnew KJ, Eschenbach DA. Bacteria in the transfer catheter tip influence the live-birth rate after in vitro fertilization. Fertil Steril. 2000;74:1118–24.PubMedCrossRef Moore DE, Soules MR, Klein NA, Fujimoto VY, Agnew KJ, Eschenbach DA. Bacteria in the transfer catheter tip influence the live-birth rate after in vitro fertilization. Fertil Steril. 2000;74:1118–24.PubMedCrossRef
20.
Zurück zum Zitat Coroleu B, Barri PN, Carreras O, Martínez F, Parriego M, Hereter L, et al. The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study. Hum Reprod. 2002;17:341–6.PubMedCrossRef Coroleu B, Barri PN, Carreras O, Martínez F, Parriego M, Hereter L, et al. The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study. Hum Reprod. 2002;17:341–6.PubMedCrossRef
21.
Zurück zum Zitat Franco Jr JG, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Best site for embryo transfer: the upper or lower half of endometrial cavity? Hum Reprod. 2004;19:1785–90.PubMedCrossRef Franco Jr JG, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Best site for embryo transfer: the upper or lower half of endometrial cavity? Hum Reprod. 2004;19:1785–90.PubMedCrossRef
22.
Zurück zum Zitat Oliveira JB, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Increased implantation and pregnancy rates obtained by placing the tip of the transfer catheter in the central area of the endometrial cavity. Reprod Biomed Online. 2004;9:435–41.PubMedCrossRef Oliveira JB, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Increased implantation and pregnancy rates obtained by placing the tip of the transfer catheter in the central area of the endometrial cavity. Reprod Biomed Online. 2004;9:435–41.PubMedCrossRef
23.
Zurück zum Zitat Abou-Setta AM. What is the best site for embryo deposition? A systematic review and meta-analysis using direct and adjusted indirect comparisons. Reprod Biomed Online. 2007;14:611–9.PubMedCrossRef Abou-Setta AM. What is the best site for embryo deposition? A systematic review and meta-analysis using direct and adjusted indirect comparisons. Reprod Biomed Online. 2007;14:611–9.PubMedCrossRef
24.
Zurück zum Zitat Veeck LL. Atlas of the Human Oocyte and Early Conceptus. Baltimore, MD: Williams and Wilkins; 1991. Veeck LL. Atlas of the Human Oocyte and Early Conceptus. Baltimore, MD: Williams and Wilkins; 1991.
25.
Zurück zum Zitat Lewin A, Schenker JG, Avrech O, Shapira S, Safran A, Friedler S. The role of uterine straightening by passive bladder distension before embryo transfer in IVF cycles. J Assist Reprod Genet. 1997;14:32–4.PubMedCentralPubMedCrossRef Lewin A, Schenker JG, Avrech O, Shapira S, Safran A, Friedler S. The role of uterine straightening by passive bladder distension before embryo transfer in IVF cycles. J Assist Reprod Genet. 1997;14:32–4.PubMedCentralPubMedCrossRef
26.
Zurück zum Zitat Minami S, Ishihara K, Araki T. Determination of blastocyst implantation site in spontaneous pregnancies using three-dimensional transvaginal ultrasound. J Nippon Med Sch. 2003;70:250–4.PubMedCrossRef Minami S, Ishihara K, Araki T. Determination of blastocyst implantation site in spontaneous pregnancies using three-dimensional transvaginal ultrasound. J Nippon Med Sch. 2003;70:250–4.PubMedCrossRef
27.
Zurück zum Zitat Baba K, Ishihara O, Hayashi N, Saitoh M, Taya J, Kinoshita K. Where does the embryo implant after embryo transfer in humans? Fertil Steril. 2000;73:123–5.PubMedCrossRef Baba K, Ishihara O, Hayashi N, Saitoh M, Taya J, Kinoshita K. Where does the embryo implant after embryo transfer in humans? Fertil Steril. 2000;73:123–5.PubMedCrossRef
28.
Zurück zum Zitat Kinoshita K. Clinical significance of detection time and site of early gestational sac by ultrasonography. Nihon Sanka Fujinka Gakkai Zasshi. 1994;46:102–8.PubMed Kinoshita K. Clinical significance of detection time and site of early gestational sac by ultrasonography. Nihon Sanka Fujinka Gakkai Zasshi. 1994;46:102–8.PubMed
29.
Zurück zum Zitat Kerin JF, Jeffrey R, Warnes GM, Cox LW, Broom TJ. A simple technique for human embryo transfer into the uterus. Lancet. 1981;2:726–7.PubMedCrossRef Kerin JF, Jeffrey R, Warnes GM, Cox LW, Broom TJ. A simple technique for human embryo transfer into the uterus. Lancet. 1981;2:726–7.PubMedCrossRef
30.
Zurück zum Zitat Leeton J, Trounson A, Jessup D, Wood C. The technique for human embryo transfer. Fertil Steril. 1982;38:156–61.PubMed Leeton J, Trounson A, Jessup D, Wood C. The technique for human embryo transfer. Fertil Steril. 1982;38:156–61.PubMed
31.
Zurück zum Zitat Fanchin R, Righini C, Olivennes F, Taylor S, de Ziegler D, Frydman R. Uterine contractions at the time of embryo transfer alter pregnancy rates after in-vitro fertilization. Hum Reprod. 1998;13:1968–74.PubMedCrossRef Fanchin R, Righini C, Olivennes F, Taylor S, de Ziegler D, Frydman R. Uterine contractions at the time of embryo transfer alter pregnancy rates after in-vitro fertilization. Hum Reprod. 1998;13:1968–74.PubMedCrossRef
32.
Zurück zum Zitat Lesny P, Killick SR, Tetlow RL, Robinson J, Maguiness SD. Embryo transfer—can we learn anything new from the observation of junctional zone contractions? Hum Reprod. 1998;13:1540–6.PubMedCrossRef Lesny P, Killick SR, Tetlow RL, Robinson J, Maguiness SD. Embryo transfer—can we learn anything new from the observation of junctional zone contractions? Hum Reprod. 1998;13:1540–6.PubMedCrossRef
33.
Zurück zum Zitat Woolcott R, Stanger J. Potentially important variables identified by transvaginal ultrasound-guided embryo transfer. Hum Reprod. 1997;12:963–6.PubMedCrossRef Woolcott R, Stanger J. Potentially important variables identified by transvaginal ultrasound-guided embryo transfer. Hum Reprod. 1997;12:963–6.PubMedCrossRef
34.
Zurück zum Zitat Pope CS, Cook EK, Arny M, Novak A, Grow DR. Influence of embryo transfer depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2004;81:51–8.PubMedCrossRef Pope CS, Cook EK, Arny M, Novak A, Grow DR. Influence of embryo transfer depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2004;81:51–8.PubMedCrossRef
35.
Zurück zum Zitat Tiras B, Polat M, Korucuoglu U, Zeyneloglu HB, Yarali H. Impact of embryo replacement depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2010;94:1341–5.PubMedCrossRef Tiras B, Polat M, Korucuoglu U, Zeyneloglu HB, Yarali H. Impact of embryo replacement depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2010;94:1341–5.PubMedCrossRef
36.
Zurück zum Zitat Rovei V, Dalmasso P, Gennarelli G, Lantieri T, Basso G, Benedetto C, Revelli A. IVF outcome is optimized when embryos are replaced between 5 and 15 mm from the fundal endometrial surface: a prospective analysis on 1184 IVF cycles. Reprod Biol Endocrinol. 2013;11. doi: 10.1186/1477-7827-11-114. Rovei V, Dalmasso P, Gennarelli G, Lantieri T, Basso G, Benedetto C, Revelli A. IVF outcome is optimized when embryos are replaced between 5 and 15 mm from the fundal endometrial surface: a prospective analysis on 1184 IVF cycles. Reprod Biol Endocrinol. 2013;11. doi: 10.​1186/​1477-7827-11-114.
37.
Zurück zum Zitat Pacchiarotti A, Mohamed MA, Micara G, Tranquilli D, Linari A, Espinola SM, et al. The impact of the depth of embryo replacement on IVF outcome. J Assist Reprod Genet. 2007;24:189–93.PubMedCentralPubMedCrossRef Pacchiarotti A, Mohamed MA, Micara G, Tranquilli D, Linari A, Espinola SM, et al. The impact of the depth of embryo replacement on IVF outcome. J Assist Reprod Genet. 2007;24:189–93.PubMedCentralPubMedCrossRef
38.
Zurück zum Zitat Nazari A, Askari HA, Check JH, O'Shaughnessy A. Embryo transfer technique as a cause of ectopic pregnancy in in vitro fertilization. Fertil Steril. 1993;60:919–21.PubMed Nazari A, Askari HA, Check JH, O'Shaughnessy A. Embryo transfer technique as a cause of ectopic pregnancy in in vitro fertilization. Fertil Steril. 1993;60:919–21.PubMed
39.
Zurück zum Zitat Frankfurter D, Trimarchi JB, Silva CP, Keefe DL. Middle to lower uterine segment embryo transfer improves implantation and pregnancy rates compared with fundal embryo transfer. Fertil Steril. 2004;81:1273–7.PubMedCrossRef Frankfurter D, Trimarchi JB, Silva CP, Keefe DL. Middle to lower uterine segment embryo transfer improves implantation and pregnancy rates compared with fundal embryo transfer. Fertil Steril. 2004;81:1273–7.PubMedCrossRef
Metadaten
Titel
Absolute position versus relative position in embryo transfer: a randomized controlled trial
verfasst von
Hwang Kwon
Dong-Hee Choi
Eun-Kyung Kim
Publikationsdatum
01.12.2015
Verlag
BioMed Central
Erschienen in
Reproductive Biology and Endocrinology / Ausgabe 1/2015
Elektronische ISSN: 1477-7827
DOI
https://doi.org/10.1186/s12958-015-0072-6

Weitere Artikel der Ausgabe 1/2015

Reproductive Biology and Endocrinology 1/2015 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.