Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis

verfasst von: Koichi Suehiro, Alexandre Joosten, Linda Suk-Ling Murphy, Olivier Desebbe, Brenton Alexander, Sang-Hyun Kim, Maxime Cannesson

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Several minimally-invasive technologies are available for cardiac output (CO) measurement in children, but the accuracy and precision of these devices have not yet been evaluated in a systematic review and meta-analysis. We conducted a comprehensive search of the medical literature in PubMed, Cochrane Library of Clinical Trials, Scopus, and Web of Science from its inception to June 2014 assessing the accuracy and precision of all minimally-invasive CO monitoring systems used in children when compared with CO monitoring reference methods. Pooled mean bias, standard deviation, and mean percentage error of included studies were calculated using a random-effects model. The inter-study heterogeneity was also assessed using an I2 statistic. A total of 20 studies (624 patients) were included. The overall random-effects pooled bias, and mean percentage error were 0.13 ± 0.44 l min−1 and 29.1 %, respectively. Significant inter-study heterogeneity was detected (P < 0.0001, I2 = 98.3 %). In the sub-analysis regarding the device, electrical cardiometry showed the smallest bias (−0.03 l min−1) and lowest percentage error (23.6 %). Significant residual heterogeneity remained after conducting sensitivity and subgroup analyses based on the various study characteristics. By meta-regression analysis, we found no independent effects of study characteristics on weighted mean difference between reference and tested methods. Although the pooled bias was small, the mean pooled percentage error was in the gray zone of clinical applicability. In the sub-group analysis, electrical cardiometry was the device that provided the most accurate measurement. However, a high heterogeneity between studies was found, likely due to a wide range of study characteristics.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Donati A, Loggi S, Preiser JC, et al. Goal-directed intraoperative therapy reduces morbidity and length of hospital stay in high-risk surgical patients. Chest. 2007;132:1817–24.CrossRefPubMed Donati A, Loggi S, Preiser JC, et al. Goal-directed intraoperative therapy reduces morbidity and length of hospital stay in high-risk surgical patients. Chest. 2007;132:1817–24.CrossRefPubMed
2.
Zurück zum Zitat Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97:820–6.CrossRefPubMed Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97:820–6.CrossRefPubMed
3.
Zurück zum Zitat Suehiro K, Tanaka K, Matsuura T, et al. The Vigileo-FloTrac system: arterial waveform analysis for measuring cardiac output and predicting fluid responsiveness: a clinical review. J Cardiothorac Vasc Anesth. 2014;28:1361–74.CrossRefPubMed Suehiro K, Tanaka K, Matsuura T, et al. The Vigileo-FloTrac system: arterial waveform analysis for measuring cardiac output and predicting fluid responsiveness: a clinical review. J Cardiothorac Vasc Anesth. 2014;28:1361–74.CrossRefPubMed
4.
Zurück zum Zitat Linton RA, Jonas MM, Tibby SM, et al. Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit. Intensive Care Med. 2000;26:1507–11.CrossRefPubMed Linton RA, Jonas MM, Tibby SM, et al. Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit. Intensive Care Med. 2000;26:1507–11.CrossRefPubMed
5.
Zurück zum Zitat Botte A, Leclerc F, Riou Y, et al. Evaluation of a noninvasive cardiac output monitor in mechanically ventilated children. Pediatr Crit Care Med. 2006;7:231–6.CrossRefPubMed Botte A, Leclerc F, Riou Y, et al. Evaluation of a noninvasive cardiac output monitor in mechanically ventilated children. Pediatr Crit Care Med. 2006;7:231–6.CrossRefPubMed
6.
Zurück zum Zitat Calamandrei M, Mirabile L, Muschetta S, Gensini GF, De Simone L, Romano SM. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography. Pediatr Crit Care Med. 2008;9:310–2.CrossRefPubMed Calamandrei M, Mirabile L, Muschetta S, Gensini GF, De Simone L, Romano SM. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography. Pediatr Crit Care Med. 2008;9:310–2.CrossRefPubMed
7.
Zurück zum Zitat Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed
8.
Zurück zum Zitat Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62:e1–34.CrossRefPubMed Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62:e1–34.CrossRefPubMed
9.
Zurück zum Zitat Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed
10.
Zurück zum Zitat Kim SH, Lilot M, Sidhu KS, et al. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology. 2014;120:1080–97.CrossRefPubMed Kim SH, Lilot M, Sidhu KS, et al. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology. 2014;120:1080–97.CrossRefPubMed
11.
Zurück zum Zitat Kim SH, Lilot M, Murphy LS, et al. Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis. Anesth Analg. 2014;119:332–46.CrossRefPubMed Kim SH, Lilot M, Murphy LS, et al. Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis. Anesth Analg. 2014;119:332–46.CrossRefPubMed
12.
Zurück zum Zitat Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155:529–36.CrossRefPubMed Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155:529–36.CrossRefPubMed
13.
Zurück zum Zitat Williamson PR, Lancaster GA, Craig JV, Smyth RL. Meta-analysis of method comparison studies. Stat Med. 2002;21:2013–25.CrossRefPubMed Williamson PR, Lancaster GA, Craig JV, Smyth RL. Meta-analysis of method comparison studies. Stat Med. 2002;21:2013–25.CrossRefPubMed
14.
Zurück zum Zitat DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials. 1986;7:177–88.CrossRefPubMed DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials. 1986;7:177–88.CrossRefPubMed
17.
Zurück zum Zitat Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W Jr. Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr. 1982;101:46–50.CrossRefPubMed Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W Jr. Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr. 1982;101:46–50.CrossRefPubMed
18.
Zurück zum Zitat Braden DS, Leatherbury L, Treiber FA, Strong WB. Noninvasive assessment of cardiac output in children using impedance cardiography. Am Heart J. 1990;120:1166–72.CrossRefPubMed Braden DS, Leatherbury L, Treiber FA, Strong WB. Noninvasive assessment of cardiac output in children using impedance cardiography. Am Heart J. 1990;120:1166–72.CrossRefPubMed
19.
Zurück zum Zitat Fakler U, Pauli C, Balling G, et al. Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery. J Thorac Cardiovasc Surg. 2007;133:224–8.CrossRefPubMed Fakler U, Pauli C, Balling G, et al. Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery. J Thorac Cardiovasc Surg. 2007;133:224–8.CrossRefPubMed
20.
Zurück zum Zitat Ficial B, Finnemore AE, Cox DJ, et al. Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants. J Am Soc Echocardiogr. 2013;26:1365–71.CrossRefPubMedPubMedCentral Ficial B, Finnemore AE, Cox DJ, et al. Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants. J Am Soc Echocardiogr. 2013;26:1365–71.CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Garisto C, Favia I, Ricci Z, et al. Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery. Paediatr Anaesth. 2015;25:143–9.CrossRefPubMed Garisto C, Favia I, Ricci Z, et al. Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery. Paediatr Anaesth. 2015;25:143–9.CrossRefPubMed
22.
Zurück zum Zitat Gentles TL, Neutze JM, Caulder AL, Greene ER. Cardiac output measurements in congenital heart disease—validation of a simple, portable Doppler method. J Ultrasound Med. 2001;20:365–70.PubMed Gentles TL, Neutze JM, Caulder AL, Greene ER. Cardiac output measurements in congenital heart disease—validation of a simple, portable Doppler method. J Ultrasound Med. 2001;20:365–70.PubMed
23.
Zurück zum Zitat Gergely M, Ablonczy L, Kramer S, et al. Comparison of transpulmonary thermodilution, transthoracic echocardiography and conventional hemodynamic monitoring in neonates and infants after open heart surgery: a preliminary study. Minerva Anestesiol. 2012;78:1101–8.PubMed Gergely M, Ablonczy L, Kramer S, et al. Comparison of transpulmonary thermodilution, transthoracic echocardiography and conventional hemodynamic monitoring in neonates and infants after open heart surgery: a preliminary study. Minerva Anestesiol. 2012;78:1101–8.PubMed
24.
Zurück zum Zitat Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E. Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med. 2012;38:1032–9.CrossRefPubMed Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E. Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med. 2012;38:1032–9.CrossRefPubMed
25.
Zurück zum Zitat Grollmuss O, Gonzalez P. Non-invasive cardiac output measurement in low and very low birth weight infants: a method comparison. Front Pediatr. 2014;2:16.CrossRefPubMedPubMedCentral Grollmuss O, Gonzalez P. Non-invasive cardiac output measurement in low and very low birth weight infants: a method comparison. Front Pediatr. 2014;2:16.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Introna RP, Pruett JK, Crumrine RC, Cuadrado AR. Use of transthoracic bioimpedance to determine cardiac output in pediatric patients. Crit Care Med. 1988;16:1101–5.CrossRefPubMed Introna RP, Pruett JK, Crumrine RC, Cuadrado AR. Use of transthoracic bioimpedance to determine cardiac output in pediatric patients. Crit Care Med. 1988;16:1101–5.CrossRefPubMed
27.
Zurück zum Zitat Jain S, Allins A, Salim A, Vafa A, Wilson MT, Margulies DR. Noninvasive Doppler ultrasonography for assessing cardiac function: can it replace the Swan–Ganz catheter? Am J Surg. 2008;196:961–7.CrossRefPubMed Jain S, Allins A, Salim A, Vafa A, Wilson MT, Margulies DR. Noninvasive Doppler ultrasonography for assessing cardiac function: can it replace the Swan–Ganz catheter? Am J Surg. 2008;196:961–7.CrossRefPubMed
28.
Zurück zum Zitat Kim JJ, Dreyer WJ, Chang AC, Breinholt JP 3rd, Grifka RG. Arterial pulse wave analysis: an accurate means of determining cardiac output in children. Pediatr Crit Care Med. 2006;7:532–5.CrossRefPubMed Kim JJ, Dreyer WJ, Chang AC, Breinholt JP 3rd, Grifka RG. Arterial pulse wave analysis: an accurate means of determining cardiac output in children. Pediatr Crit Care Med. 2006;7:532–5.CrossRefPubMed
29.
Zurück zum Zitat Levy RJ, Chiavacci RM, Nicolson SC, et al. An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children. Anesth Analg. 2004;99:1642–7.CrossRefPubMed Levy RJ, Chiavacci RM, Nicolson SC, et al. An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children. Anesth Analg. 2004;99:1642–7.CrossRefPubMed
30.
Zurück zum Zitat McLuckie A, Murdoch IA, Marsh MJ, Anderson D. A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients. Acta Paediatr. 1996;85:336–8.CrossRefPubMed McLuckie A, Murdoch IA, Marsh MJ, Anderson D. A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients. Acta Paediatr. 1996;85:336–8.CrossRefPubMed
31.
Zurück zum Zitat Mellander M, Sabel KG, Caidahl K, Solymar L, Eriksson B. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol. 1987;8:241–6.CrossRefPubMed Mellander M, Sabel KG, Caidahl K, Solymar L, Eriksson B. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol. 1987;8:241–6.CrossRefPubMed
32.
Zurück zum Zitat Morrow WR, Murphy DJ Jr, Fisher DJ, Huhta JC, Jefferson LS, Smith EO. Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support. Pediatr Cardiol. 1988;9:131–6.CrossRefPubMed Morrow WR, Murphy DJ Jr, Fisher DJ, Huhta JC, Jefferson LS, Smith EO. Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support. Pediatr Cardiol. 1988;9:131–6.CrossRefPubMed
33.
Zurück zum Zitat Murdoch IA, Marsh MJ, Tibby SM, McLuckie A. Continuous haemodynamic monitoring in children: use of transoesophageal Doppler. Acta Paediatr. 1995;84:761–4.CrossRefPubMed Murdoch IA, Marsh MJ, Tibby SM, McLuckie A. Continuous haemodynamic monitoring in children: use of transoesophageal Doppler. Acta Paediatr. 1995;84:761–4.CrossRefPubMed
34.
Zurück zum Zitat Nguyen HB, Banta DP, Stewart G, et al. Cardiac index measurements by transcutaneous Doppler ultrasound and transthoracic echocardiography in adult and pediatric emergency patients. J Clin Monit Comput. 2010;24:237–47.CrossRefPubMed Nguyen HB, Banta DP, Stewart G, et al. Cardiac index measurements by transcutaneous Doppler ultrasound and transthoracic echocardiography in adult and pediatric emergency patients. J Clin Monit Comput. 2010;24:237–47.CrossRefPubMed
35.
Zurück zum Zitat Notterman DA, Castello FV, Steinberg C, Greenwald BM, O’Loughlin JE, Gold JP. A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill children. J Pediatr. 1989;115:554–60.CrossRefPubMed Notterman DA, Castello FV, Steinberg C, Greenwald BM, O’Loughlin JE, Gold JP. A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill children. J Pediatr. 1989;115:554–60.CrossRefPubMed
36.
Zurück zum Zitat Patel N, Dodsworth M, Mills JF. Cardiac output measurement in newborn infants using the ultrasonic cardiac output monitor: an assessment of agreement with conventional echocardiography, repeatability and new user experience. Arch Dis Child Fetal Neonatal Ed. 2011;96:F206–11.CrossRefPubMed Patel N, Dodsworth M, Mills JF. Cardiac output measurement in newborn infants using the ultrasonic cardiac output monitor: an assessment of agreement with conventional echocardiography, repeatability and new user experience. Arch Dis Child Fetal Neonatal Ed. 2011;96:F206–11.CrossRefPubMed
37.
Zurück zum Zitat Pauli C, Fakler U, Genz T, Hennig M, Lorenz HP, Hess J. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle. Intensive Care Med. 2002;28:947–52.CrossRefPubMed Pauli C, Fakler U, Genz T, Hennig M, Lorenz HP, Hess J. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle. Intensive Care Med. 2002;28:947–52.CrossRefPubMed
38.
Zurück zum Zitat Pianosi P, Garros D. Comparison of impedance cardiography with indirect Fick (CO2) method of measuring cardiac output in healthy children during exercise. Am J Cardiol. 1996;77:745–9.CrossRefPubMed Pianosi P, Garros D. Comparison of impedance cardiography with indirect Fick (CO2) method of measuring cardiac output in healthy children during exercise. Am J Cardiol. 1996;77:745–9.CrossRefPubMed
39.
Zurück zum Zitat Rein AJ, Hsieh KS, Elixson M, et al. Cardiac output estimates in the pediatric intensive care unit using a continuous-wave Doppler computer: validation and limitations of the technique. Am Heart J. 1986;112:97–103.CrossRefPubMed Rein AJ, Hsieh KS, Elixson M, et al. Cardiac output estimates in the pediatric intensive care unit using a continuous-wave Doppler computer: validation and limitations of the technique. Am Heart J. 1986;112:97–103.CrossRefPubMed
40.
Zurück zum Zitat Saxena R, Durward A, Puppala NK, Murdoch IA, Tibby SM. Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study. Br J Anaesth. 2013;110:425–31.CrossRefPubMed Saxena R, Durward A, Puppala NK, Murdoch IA, Tibby SM. Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study. Br J Anaesth. 2013;110:425–31.CrossRefPubMed
41.
Zurück zum Zitat Song R, Rich W, Kim JH, Finer NN, Katheria AC. The use of electrical cardiometry for continuous cardiac output monitoring in preterm neonates: a validation study. Am J Perinatol. 2014;31:1105–10.CrossRefPubMed Song R, Rich W, Kim JH, Finer NN, Katheria AC. The use of electrical cardiometry for continuous cardiac output monitoring in preterm neonates: a validation study. Am J Perinatol. 2014;31:1105–10.CrossRefPubMed
42.
Zurück zum Zitat Taylor K, La Rotta G, McCrindle BW, Manlhiot C, Redington A, Holtby H. A comparison of cardiac output by thoracic impedance and direct fick in children with congenital heart disease undergoing diagnostic cardiac catheterization. J Cardiothorac Vasc Anesth. 2011;25:776–9.CrossRefPubMed Taylor K, La Rotta G, McCrindle BW, Manlhiot C, Redington A, Holtby H. A comparison of cardiac output by thoracic impedance and direct fick in children with congenital heart disease undergoing diagnostic cardiac catheterization. J Cardiothorac Vasc Anesth. 2011;25:776–9.CrossRefPubMed
43.
Zurück zum Zitat Taylor K, Manlhiot C, McCrindle B, Grosse-Wortmann L, Holtby H. Poor accuracy of noninvasive cardiac output monitoring using bioimpedance cardiography [PhysioFlow(R)] compared to magnetic resonance imaging in pediatric patients. Anesth Analg. 2012;114:771–5.CrossRefPubMed Taylor K, Manlhiot C, McCrindle B, Grosse-Wortmann L, Holtby H. Poor accuracy of noninvasive cardiac output monitoring using bioimpedance cardiography [PhysioFlow(R)] compared to magnetic resonance imaging in pediatric patients. Anesth Analg. 2012;114:771–5.CrossRefPubMed
44.
Zurück zum Zitat Tibballs J. A comparative study of cardiac output in neonates supported by mechanical ventilation: measurement with thoracic electrical bioimpedance and pulsed Doppler ultrasound. J Pediatr. 1989;114:632–5.CrossRefPubMed Tibballs J. A comparative study of cardiac output in neonates supported by mechanical ventilation: measurement with thoracic electrical bioimpedance and pulsed Doppler ultrasound. J Pediatr. 1989;114:632–5.CrossRefPubMed
45.
Zurück zum Zitat Tibby SM, Hatherill M, Marsh MJ, Morrison G, Anderson D, Murdoch IA. Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants. Intensive Care Med. 1997;23:987–91.CrossRefPubMed Tibby SM, Hatherill M, Marsh MJ, Morrison G, Anderson D, Murdoch IA. Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants. Intensive Care Med. 1997;23:987–91.CrossRefPubMed
46.
Zurück zum Zitat Wippermann CF, Huth RG, Schmidt FX, Thul J, Betancor M, Schranz D. Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method. Intensive Care Med. 1996;22:467–71.CrossRefPubMed Wippermann CF, Huth RG, Schmidt FX, Thul J, Betancor M, Schranz D. Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method. Intensive Care Med. 1996;22:467–71.CrossRefPubMed
47.
Zurück zum Zitat Wippermann CF, Schranz D, Huth R, Zepp F, Oelert H, Jungst BK. Determination of cardiac output by an angle and diameter independent dual beam Doppler technique in critically ill infants. Br Heart J. 1992;67:180–4.CrossRefPubMedPubMedCentral Wippermann CF, Schranz D, Huth R, Zepp F, Oelert H, Jungst BK. Determination of cardiac output by an angle and diameter independent dual beam Doppler technique in critically ill infants. Br Heart J. 1992;67:180–4.CrossRefPubMedPubMedCentral
48.
Zurück zum Zitat Knirsch W, Kretschmar O, Tomaske M, et al. Comparison of cardiac output measurement using the CardioQP oesophageal Doppler with cardiac output measurement using thermodilution technique in children during heart catheterisation. Anaesthesia. 2008;63:851–5.CrossRefPubMed Knirsch W, Kretschmar O, Tomaske M, et al. Comparison of cardiac output measurement using the CardioQP oesophageal Doppler with cardiac output measurement using thermodilution technique in children during heart catheterisation. Anaesthesia. 2008;63:851–5.CrossRefPubMed
49.
Zurück zum Zitat Knirsch W, Kretschmar O, Tomaske M, et al. Cardiac output measurement in children: comparison of the ultrasound cardiac output monitor with thermodilution cardiac output measurement. Intensive Care Med. 2008;34:1060–4.CrossRefPubMed Knirsch W, Kretschmar O, Tomaske M, et al. Cardiac output measurement in children: comparison of the ultrasound cardiac output monitor with thermodilution cardiac output measurement. Intensive Care Med. 2008;34:1060–4.CrossRefPubMed
50.
Zurück zum Zitat Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth. 2008;100:88–94.CrossRefPubMed Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth. 2008;100:88–94.CrossRefPubMed
51.
Zurück zum Zitat Schubert S, Schmitz T, Weiss M, et al. Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry. J Clin Monit Comput. 2008;22:299–307.CrossRefPubMed Schubert S, Schmitz T, Weiss M, et al. Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry. J Clin Monit Comput. 2008;22:299–307.CrossRefPubMed
52.
Zurück zum Zitat Tomaske M, Knirsch W, Kretschmar O, et al. Cardiac output measurement in children: comparison of Aesculon cardiac output monitor and thermodilution. Br J Anaesth. 2008;100:517–20.CrossRefPubMed Tomaske M, Knirsch W, Kretschmar O, et al. Cardiac output measurement in children: comparison of Aesculon cardiac output monitor and thermodilution. Br J Anaesth. 2008;100:517–20.CrossRefPubMed
53.
Zurück zum Zitat Teng S, Kaufman J, Pan ZX, Czaja A, Shockley H, da Cruz E. Continuous arterial pressure waveform monitoring in pediatric cardiac transplant, cardiomyopathy and pulmonary hypertension patients. Intensive Care Med. 2011;37:1297–301.CrossRefPubMed Teng S, Kaufman J, Pan ZX, Czaja A, Shockley H, da Cruz E. Continuous arterial pressure waveform monitoring in pediatric cardiac transplant, cardiomyopathy and pulmonary hypertension patients. Intensive Care Med. 2011;37:1297–301.CrossRefPubMed
54.
Zurück zum Zitat Crittendon I 3rd, Dreyer WJ, Decker JA, Kim JJ. Ultrasound dilution: an accurate means of determining cardiac output in children. Pediatr Crit Care Med. 2012;13:42–6.CrossRefPubMedPubMedCentral Crittendon I 3rd, Dreyer WJ, Decker JA, Kim JJ. Ultrasound dilution: an accurate means of determining cardiac output in children. Pediatr Crit Care Med. 2012;13:42–6.CrossRefPubMedPubMedCentral
55.
Zurück zum Zitat Noori S, Drabu B, Soleymani S, Seri I. Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography. Arch Dis Child Fetal Neonatal Ed. 2012;97:F340–3.CrossRefPubMed Noori S, Drabu B, Soleymani S, Seri I. Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography. Arch Dis Child Fetal Neonatal Ed. 2012;97:F340–3.CrossRefPubMed
56.
Zurück zum Zitat Weisz DE, Jain A, McNamara PJ, El-khuffash A. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology. 2012;102:61–7.CrossRefPubMed Weisz DE, Jain A, McNamara PJ, El-khuffash A. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology. 2012;102:61–7.CrossRefPubMed
57.
Zurück zum Zitat Floh AA, La Rotta G, Wermelt JZ, Bastero-Minon P, Sivarajan VB, Humpl T. Validation of a new method based on ultrasound velocity dilution to measure cardiac output in paediatric patients. Intensive Care Med. 2013;39:926–33.CrossRefPubMed Floh AA, La Rotta G, Wermelt JZ, Bastero-Minon P, Sivarajan VB, Humpl T. Validation of a new method based on ultrasound velocity dilution to measure cardiac output in paediatric patients. Intensive Care Med. 2013;39:926–33.CrossRefPubMed
58.
Zurück zum Zitat Rauch R, Welisch E, Lansdell N, et al. Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography. J Clin Monit Comput. 2013;27:187–93.CrossRefPubMed Rauch R, Welisch E, Lansdell N, et al. Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography. J Clin Monit Comput. 2013;27:187–93.CrossRefPubMed
59.
Zurück zum Zitat Boehne M, Baustert M, Paetzel V, et al. Determination of cardiac output by ultrasound dilution technique in infants and children: a validation study against direct Fick principle. Br J Anaesth. 2014;112:469–76.CrossRefPubMed Boehne M, Baustert M, Paetzel V, et al. Determination of cardiac output by ultrasound dilution technique in infants and children: a validation study against direct Fick principle. Br J Anaesth. 2014;112:469–76.CrossRefPubMed
60.
Zurück zum Zitat Lindberg L, Johansson S, Perez-de-Sa V. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children. Pediatr Crit Care Med. 2014;15:139–47.CrossRefPubMed Lindberg L, Johansson S, Perez-de-Sa V. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children. Pediatr Crit Care Med. 2014;15:139–47.CrossRefPubMed
61.
Zurück zum Zitat Sun Y, Wu C, Wu JZ, et al. Noninvasive cardiac output monitoring using bioreactance-based technique in pediatric patients with or without ventricular septal defect during anesthesia: in comparison with echocardiography. Paediatr Anaesth. 2015;25:167–73.CrossRefPubMed Sun Y, Wu C, Wu JZ, et al. Noninvasive cardiac output monitoring using bioreactance-based technique in pediatric patients with or without ventricular septal defect during anesthesia: in comparison with echocardiography. Paediatr Anaesth. 2015;25:167–73.CrossRefPubMed
62.
Zurück zum Zitat Terada T, Maemura Y, Yoshida A, Muto R, Ochiai R. Evaluation of the estimated continuous cardiac output monitoring system in adults and children undergoing kidney transplant surgery: a pilot study. J Clin Monit Comput. 2014;28:95–9.CrossRefPubMed Terada T, Maemura Y, Yoshida A, Muto R, Ochiai R. Evaluation of the estimated continuous cardiac output monitoring system in adults and children undergoing kidney transplant surgery: a pilot study. J Clin Monit Comput. 2014;28:95–9.CrossRefPubMed
63.
Zurück zum Zitat Vergnaud E, Vidal C, Montmayeur Verchere J, et al. Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients. Paediatr Anaesth. 2015;25:160–6.CrossRefPubMed Vergnaud E, Vidal C, Montmayeur Verchere J, et al. Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients. Paediatr Anaesth. 2015;25:160–6.CrossRefPubMed
64.
Zurück zum Zitat Wongsirimetheekul T, Khositseth A, Lertbunrian R. Non-invasive cardiac output assessment in critically ill paediatric patients. Acta Cardiol. 2014;69:167–73.PubMed Wongsirimetheekul T, Khositseth A, Lertbunrian R. Non-invasive cardiac output assessment in critically ill paediatric patients. Acta Cardiol. 2014;69:167–73.PubMed
65.
Zurück zum Zitat Skowno JJ, Broadhead M. Cardiac output measurement in pediatric anesthesia. Paediatr Anaesth. 2008;18:1019–28.CrossRefPubMed Skowno JJ, Broadhead M. Cardiac output measurement in pediatric anesthesia. Paediatr Anaesth. 2008;18:1019–28.CrossRefPubMed
66.
Zurück zum Zitat Ceneviva G, Paschall JA, Maffei F, Carcillo JA. Hemodynamic support in fluid-refractory pediatric septic shock. Pediatrics. 1998;102:e19.CrossRefPubMed Ceneviva G, Paschall JA, Maffei F, Carcillo JA. Hemodynamic support in fluid-refractory pediatric septic shock. Pediatrics. 1998;102:e19.CrossRefPubMed
67.
Zurück zum Zitat Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth. 2013;27:121–34.CrossRefPubMed Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth. 2013;27:121–34.CrossRefPubMed
68.
Zurück zum Zitat Egan JR, Festa M, Cole AD, Nunn GR, Gillis J, Winlaw DS. Clinical assessment of cardiac performance in infants and children following cardiac surgery. Intensive Care Med. 2005;31:568–73.CrossRefPubMed Egan JR, Festa M, Cole AD, Nunn GR, Gillis J, Winlaw DS. Clinical assessment of cardiac performance in infants and children following cardiac surgery. Intensive Care Med. 2005;31:568–73.CrossRefPubMed
69.
Zurück zum Zitat Slagt C, Malagon I, Groeneveld AB. Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation. Br J Anaesth. 2014;112:626–37.CrossRefPubMed Slagt C, Malagon I, Groeneveld AB. Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation. Br J Anaesth. 2014;112:626–37.CrossRefPubMed
70.
Zurück zum Zitat Marque S, Cariou A, Chiche JD, Squara P. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care. 2009;13:R73.CrossRefPubMedPubMedCentral Marque S, Cariou A, Chiche JD, Squara P. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care. 2009;13:R73.CrossRefPubMedPubMedCentral
71.
Zurück zum Zitat Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med. 2007;33:1191–4.CrossRefPubMed Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med. 2007;33:1191–4.CrossRefPubMed
72.
Zurück zum Zitat Waldron NH, Miller TE, Thacker JK, et al. A prospective comparison of a noninvasive cardiac output monitor versus esophageal doppler monitor for goal-directed fluid therapy in colorectal surgery patients. Anesth Analg. 2014;118:966–75.CrossRefPubMed Waldron NH, Miller TE, Thacker JK, et al. A prospective comparison of a noninvasive cardiac output monitor versus esophageal doppler monitor for goal-directed fluid therapy in colorectal surgery patients. Anesth Analg. 2014;118:966–75.CrossRefPubMed
73.
Zurück zum Zitat Cheng HM, Lang D, Tufanaru C, Pearson A. Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: a systematic review and meta-analysis. Int J Cardiol. 2013;167:1867–76.CrossRefPubMed Cheng HM, Lang D, Tufanaru C, Pearson A. Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: a systematic review and meta-analysis. Int J Cardiol. 2013;167:1867–76.CrossRefPubMed
74.
Zurück zum Zitat Craig JV, Lancaster GA, Williamson PR, Smyth RL. Temperature measured at the axilla compared with rectum in children and young people: systematic review. BMJ. 2000;320:1174–8.CrossRefPubMedPubMedCentral Craig JV, Lancaster GA, Williamson PR, Smyth RL. Temperature measured at the axilla compared with rectum in children and young people: systematic review. BMJ. 2000;320:1174–8.CrossRefPubMedPubMedCentral
75.
Zurück zum Zitat Wippermann CF, Huth RG, Schmidt FX, Thul J, Betancor M, Schranz D. Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method. Intensive Care Med. 1996;22:467–71.CrossRefPubMed Wippermann CF, Huth RG, Schmidt FX, Thul J, Betancor M, Schranz D. Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method. Intensive Care Med. 1996;22:467–71.CrossRefPubMed
76.
Zurück zum Zitat Chew MS, Poelaert J. Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature. Intensive Care Med. 2003;29:1889–94.CrossRefPubMed Chew MS, Poelaert J. Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature. Intensive Care Med. 2003;29:1889–94.CrossRefPubMed
77.
Zurück zum Zitat Arulkumaran N, Corredor C, Hamilton MA, et al. Cardiac complications associated with goal-directed therapy in high-risk surgical patients: a meta-analysis. Br J Anaesth. 2014;112:648–59.CrossRefPubMed Arulkumaran N, Corredor C, Hamilton MA, et al. Cardiac complications associated with goal-directed therapy in high-risk surgical patients: a meta-analysis. Br J Anaesth. 2014;112:648–59.CrossRefPubMed
78.
Zurück zum Zitat Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg. 2011;112:1392–402.CrossRefPubMed Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg. 2011;112:1392–402.CrossRefPubMed
Metadaten
Titel
Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis
verfasst von
Koichi Suehiro
Alexandre Joosten
Linda Suk-Ling Murphy
Olivier Desebbe
Brenton Alexander
Sang-Hyun Kim
Maxime Cannesson
Publikationsdatum
29.08.2015
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 5/2016
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9757-9

Weitere Artikel der Ausgabe 5/2016

Journal of Clinical Monitoring and Computing 5/2016 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.