Skip to main content
Erschienen in: Intensive Care Medicine 11/2003

01.11.2003 | Review

Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature

verfasst von: Michelle S. Chew, Jan Poelaert

Erschienen in: Intensive Care Medicine | Ausgabe 11/2003

Einloggen, um Zugang zu erhalten

Abstract

Objective

Review of the accuracy and repeatability of Doppler cardiac output (CO) measurements in children.

Design

Publications in the scientific literature retrieved using a computerized Medline search from 1982–2002 and a manual review of article bibliographies. Studies comparing Doppler flow measurements with thermodilution, Fick, or dye dilution methods in the pediatric critical care setting were identified to assess the bias, precision, and intra- and interobserver repeatability of Doppler CO measurement. Where results were not suitable for comparison and the original measurements available, data were re-analyzed using appropriate statistical methods and presented in comparative tables.

Results

The precision of pediatric Doppler CO measurements compared to thermodilution, dye dilution, or Fick methods is around 30% and repeatability varies from less than 1% to 22%. Bias is generally less than 10% but varies considerably.

Conclusions

The bias, precision, and repeatability from study to study indicate that Doppler CO measurements are acceptably reproducible in children, with best results when used to track changes rather than absolute values, and using the transesophageal approach.
Literatur
1.
Zurück zum Zitat Tibby SM, Hatherill M, Marsh MJ, Murdoch IA (1997) Clinicians' abilities to estimate cardiac index in ventilated children and infants. Arch Dis Child 77:516–518PubMed Tibby SM, Hatherill M, Marsh MJ, Murdoch IA (1997) Clinicians' abilities to estimate cardiac index in ventilated children and infants. Arch Dis Child 77:516–518PubMed
2.
Zurück zum Zitat Richardson JR, Ferguson J, Hiscox J, Rawles J (1998) Non-invasive assessment of cardiac output in children. J Accid Emerg Med 15:304–307PubMed Richardson JR, Ferguson J, Hiscox J, Rawles J (1998) Non-invasive assessment of cardiac output in children. J Accid Emerg Med 15:304–307PubMed
3.
Zurück zum Zitat Boyd O, Grounds RM, Bennett ED (1993) A randomised clinical trial of the effect if deliberate increase of oxygen delivery on mortality in high-risk surgical patients. JAMA 270:2699–2707PubMed Boyd O, Grounds RM, Bennett ED (1993) A randomised clinical trial of the effect if deliberate increase of oxygen delivery on mortality in high-risk surgical patients. JAMA 270:2699–2707PubMed
4.
Zurück zum Zitat Shoemaker WC, Kram HB, Appel PL, Fleming AW (1990) The efficacy of central venous and pulmonary artery catheters and therapy based upon them in reducing mortality and morbidity. Arch Surg 125:1332–1338PubMed Shoemaker WC, Kram HB, Appel PL, Fleming AW (1990) The efficacy of central venous and pulmonary artery catheters and therapy based upon them in reducing mortality and morbidity. Arch Surg 125:1332–1338PubMed
5.
Zurück zum Zitat Bishop MH, Shoemaker WC, Appel PL, Meade P, Ordog GJ, Wasserberger J, Wo CJ, Rimle DA, Kram HB, Umali R (1995) Prospective, randomised trial of survivor values of cardiac index, oxygen delivery and oxygen consumption as resuscitation endpoints in severe trauma. J Trauma 38:780–787PubMed Bishop MH, Shoemaker WC, Appel PL, Meade P, Ordog GJ, Wasserberger J, Wo CJ, Rimle DA, Kram HB, Umali R (1995) Prospective, randomised trial of survivor values of cardiac index, oxygen delivery and oxygen consumption as resuscitation endpoints in severe trauma. J Trauma 38:780–787PubMed
6.
Zurück zum Zitat Hayes MA, Timmins AC, Yau EHS, Palazzo M, Hinds CJ, Watson D (1994) Elevation of systemic oxygen delivery in the treatment of critically ill patients. N Engl J Med 330:1717–1722PubMed Hayes MA, Timmins AC, Yau EHS, Palazzo M, Hinds CJ, Watson D (1994) Elevation of systemic oxygen delivery in the treatment of critically ill patients. N Engl J Med 330:1717–1722PubMed
7.
Zurück zum Zitat Gattitoni L, Brazzi L, Pelosi P, Latini R, Tognoni G, Pesenti A, Fumagalli R (1995) A trial of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med 333:1025–1032PubMed Gattitoni L, Brazzi L, Pelosi P, Latini R, Tognoni G, Pesenti A, Fumagalli R (1995) A trial of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med 333:1025–1032PubMed
8.
Zurück zum Zitat Thompson AE (1997) Pulmonary artery catheterizaton in children. New Horiz 5:244–250PubMed Thompson AE (1997) Pulmonary artery catheterizaton in children. New Horiz 5:244–250PubMed
9.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8476:307–310 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8476:307–310
10.
Zurück zum Zitat Wodey E, Gai V, Carre F, Ecoffey C (2001) Accuracy and limitations of continuous oesophageal aortic blood flow measurement during general anaesthesia for children: comparison with transcutaneous echography-Doppler. Paediatr Anaesth 11:309–317PubMed Wodey E, Gai V, Carre F, Ecoffey C (2001) Accuracy and limitations of continuous oesophageal aortic blood flow measurement during general anaesthesia for children: comparison with transcutaneous echography-Doppler. Paediatr Anaesth 11:309–317PubMed
11.
Zurück zum Zitat Tibby SM, Hatherill M, Murdoch IA (2000) Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output. Crit Care Med 28:2045–2050 Tibby SM, Hatherill M, Murdoch IA (2000) Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output. Crit Care Med 28:2045–2050
12.
Zurück zum Zitat Murdoch IA, Marsh MJ, Tibby SM, McLuckie A (1995) Continuous haemodynamic monitoring in children: use of transoesophageal Doppler. Acta Paediatr 84:761–764PubMed Murdoch IA, Marsh MJ, Tibby SM, McLuckie A (1995) Continuous haemodynamic monitoring in children: use of transoesophageal Doppler. Acta Paediatr 84:761–764PubMed
13.
Zurück zum Zitat Mohan UR, Britto J, Habibi P, deMunter C, Nadel S (2002) Noninvasive measurement of cardiac output in critically ill children. Pediatr Cardiol 23:58–61PubMed Mohan UR, Britto J, Habibi P, deMunter C, Nadel S (2002) Noninvasive measurement of cardiac output in critically ill children. Pediatr Cardiol 23:58–61PubMed
14.
Zurück zum Zitat Critchley LAH and Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85–91CrossRefPubMed Critchley LAH and Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85–91CrossRefPubMed
15.
Zurück zum Zitat Mellander M, Sabel K, Caidahl K, Solymar L, Eriksson B (1987) Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol 8:241–246PubMed Mellander M, Sabel K, Caidahl K, Solymar L, Eriksson B (1987) Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol 8:241–246PubMed
16.
Zurück zum Zitat Sholler GF, Whight CM, Celermajer JM (1986) Pulsed Doppler echocardiographic assessment, including use of aortic leaflet separation, of cardiac output in children with structural heart disease. Am J Cardiol 57:1195–1197PubMed Sholler GF, Whight CM, Celermajer JM (1986) Pulsed Doppler echocardiographic assessment, including use of aortic leaflet separation, of cardiac output in children with structural heart disease. Am J Cardiol 57:1195–1197PubMed
17.
Zurück zum Zitat Notterman DA, Castello FV, Steinberg C, Greenwald BM, O'Loughlin JE, Gold JP (1988) A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill children. J Pediatr 115:554–560 Notterman DA, Castello FV, Steinberg C, Greenwald BM, O'Loughlin JE, Gold JP (1988) A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill children. J Pediatr 115:554–560
18.
Zurück zum Zitat Morrow WR, Murphy DJ, Fisher DJ, Huhta JC, Jefferson LS, O'Brian Smith E (1988) Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support. Pediatr Cardiol 9:131–136PubMed Morrow WR, Murphy DJ, Fisher DJ, Huhta JC, Jefferson LS, O'Brian Smith E (1988) Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support. Pediatr Cardiol 9:131–136PubMed
19.
Zurück zum Zitat Tibballs J, Osborne A, Hockmann M (1988) A comparative study of cardiac output measurement by dye dilution and pulsed Doppler ultrasound. Anaesth Intensive Care 16:272–277PubMed Tibballs J, Osborne A, Hockmann M (1988) A comparative study of cardiac output measurement by dye dilution and pulsed Doppler ultrasound. Anaesth Intensive Care 16:272–277PubMed
20.
Zurück zum Zitat Wipperman CF, Schranz D, Huth R, Zepp F, Oelert H, Jungst B (1992) Determination of cardiac output by an angle and diameter independent dual beam Doppler in critically ill infants. Br Heart J 67:180–184PubMed Wipperman CF, Schranz D, Huth R, Zepp F, Oelert H, Jungst B (1992) Determination of cardiac output by an angle and diameter independent dual beam Doppler in critically ill infants. Br Heart J 67:180–184PubMed
21.
Zurück zum Zitat Rein A, Hsieh K, Elixaon M, Colan S, Lang P, Sanders S, Casteneda A (1986) Cardiac output estimates in the pediatric intensive care unit using a continuous wave Doppler computer: validation and limitations of the technique. Am Heart J 112:97–102PubMed Rein A, Hsieh K, Elixaon M, Colan S, Lang P, Sanders S, Casteneda A (1986) Cardiac output estimates in the pediatric intensive care unit using a continuous wave Doppler computer: validation and limitations of the technique. Am Heart J 112:97–102PubMed
22.
Zurück zum Zitat Darmon PL, Hillel Z, Mogtader A, Mindich B, Thys D (1994) Cardiac outout by transesophageal echocardiography using continuous wave Doppler across the aortic valve. Anesthesiology 80:796–805PubMed Darmon PL, Hillel Z, Mogtader A, Mindich B, Thys D (1994) Cardiac outout by transesophageal echocardiography using continuous wave Doppler across the aortic valve. Anesthesiology 80:796–805PubMed
23.
Zurück zum Zitat Hudson I, Hudson A, Aitchison T, Holland B, Turner T (1990) Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound. Arch Dis Child 65:15–19PubMed Hudson I, Hudson A, Aitchison T, Holland B, Turner T (1990) Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound. Arch Dis Child 65:15–19PubMed
24.
Zurück zum Zitat Claflin KS, Alverson DC, Pathak D, Angelus P, Backstrom C, Werner S (1988) Cardiac output determination in the newborn: reproducibility of the pulsed Doppler velocity measurement. J Ultrasound Med 7:311–315PubMed Claflin KS, Alverson DC, Pathak D, Angelus P, Backstrom C, Werner S (1988) Cardiac output determination in the newborn: reproducibility of the pulsed Doppler velocity measurement. J Ultrasound Med 7:311–315PubMed
25.
Zurück zum Zitat Hanseus K, Björkhem G, Lundström NR (1994) Cardiac function in healthy infants and children: Doppler echocardiographic evaluation. Pediatr Cardiol 15:211–218PubMed Hanseus K, Björkhem G, Lundström NR (1994) Cardiac function in healthy infants and children: Doppler echocardiographic evaluation. Pediatr Cardiol 15:211–218PubMed
26.
Zurück zum Zitat Childs C, Goldring S, Tann W, Hillier VF (1998) Suprasternal Doppler ultrasound for assessment of stroke distance. Arch Dis Child 79:251–255PubMed Childs C, Goldring S, Tann W, Hillier VF (1998) Suprasternal Doppler ultrasound for assessment of stroke distance. Arch Dis Child 79:251–255PubMed
27.
Zurück zum Zitat Hirsimaki K, Kerp P, Seppala T, Holstrom K (1993) Mean or maximum velocity using pulsed Doppler ultrasound in determination of Doppler derived cardiac output in the newborn infant. Med Biol Eng Comput 31:58–56PubMed Hirsimaki K, Kerp P, Seppala T, Holstrom K (1993) Mean or maximum velocity using pulsed Doppler ultrasound in determination of Doppler derived cardiac output in the newborn infant. Med Biol Eng Comput 31:58–56PubMed
28.
Zurück zum Zitat Chew MS, Brandberg J, Bjarum S, Baek Jensen K, Sloth E, Ask P, Hasenkam JM, Janerot Sjöberg B (2000) Pediatric cardiac output measurement using surface integration of velocity vectors: an in vivo validation study. Crit Care Med 28:3664–73661PubMed Chew MS, Brandberg J, Bjarum S, Baek Jensen K, Sloth E, Ask P, Hasenkam JM, Janerot Sjöberg B (2000) Pediatric cardiac output measurement using surface integration of velocity vectors: an in vivo validation study. Crit Care Med 28:3664–73661PubMed
29.
Zurück zum Zitat Welch E, Duara S, Suguihara C, Bandstra E, Bancalari E (1994) Validation of cardiac output measurements with noninvasive Doppler echocardiography by thermodilution and Fick methods in newborn piglets. Biol Neonate 66:137–145PubMed Welch E, Duara S, Suguihara C, Bandstra E, Bancalari E (1994) Validation of cardiac output measurements with noninvasive Doppler echocardiography by thermodilution and Fick methods in newborn piglets. Biol Neonate 66:137–145PubMed
30.
Zurück zum Zitat Stevenson J (1999) Incidence of complications in pediatric transesophageal echocardiography: experience in 1650 cases. J Am Soc Echocardiogr 12:527–532PubMed Stevenson J (1999) Incidence of complications in pediatric transesophageal echocardiography: experience in 1650 cases. J Am Soc Echocardiogr 12:527–532PubMed
31.
Zurück zum Zitat Wallace AW, Salahieh A, Lawrence A, Spector K, Owens C, Alonso D (2000) Endotracheal cardiac output monitor Anesthesiology 92:178–189 Wallace AW, Salahieh A, Lawrence A, Spector K, Owens C, Alonso D (2000) Endotracheal cardiac output monitor Anesthesiology 92:178–189
32.
Zurück zum Zitat Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W (1982) Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr 101:46–50PubMed Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W (1982) Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr 101:46–50PubMed
Metadaten
Titel
Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature
verfasst von
Michelle S. Chew
Jan Poelaert
Publikationsdatum
01.11.2003
Verlag
Springer-Verlag
Erschienen in
Intensive Care Medicine / Ausgabe 11/2003
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-003-1967-9

Weitere Artikel der Ausgabe 11/2003

Intensive Care Medicine 11/2003 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.