Accuracy of CO2 monitoring via nasal cannulas and oral bite blocks during sedation for esophagogastroduodenoscopy

verfasst von: Kuo-Chen Chang, Joe Orr, Wei-Chih Hsu, Lu Yu, Mei-Yung Tsou, Dwayne R. Westenskow, Chien-Kun Ting

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Esophagogastroduodenoscopy procedures are typically performed under conscious sedation. Drug-induced respiratory depression is a major cause of serious adverse effects during sedation. Capnographic monitoring of respiratory activity improves patient safety during procedural sedation. This bench study compares the performance of the nasal cannulas and oral bite blocks used to monitor exhaled CO2 during sedation. We used a spontaneously breathing mechanical lung to evaluated four CO2 sampling nasal cannulas and three CO2 sampling bite blocks. We placed pneumatic resistors in the mouth of the manikin to simulate different levels of mouth opening. We compared CO2 measurements taken from the sampling device to CO2 measurements taken directly from the trachea. The end tidal CO2 concentration (PetCO2) measured through the bite blocks and nasal cannulas was always lower than the corresponding PetCO2 measured at the trachea. The difference became larger as the amount of oxygen delivered through the devices increased. The difference was larger during normal ventilation than during hypoventilation. The difference became larger as the amount of oral breathing increased. The two nasal cannulas without oral cups failed to provide sufficient CO2 for breath detection when the mouth was fully open and oxygen was delivered at 10 L/min. Our simulation found that respiratory rate can be accurately monitored during the procedure using a CO2 sampling bite block or a nasal cannula with oral cup. The accuracy of PetCO2 measurements depends on the device used, the amount of supplement oxygen, the amount of oral breathing and the patient’s minute ventilation.
Literatur
3.
Zurück zum Zitat Levitzky BE, Lopez R, Dumot JA, Vargo JJ. Moderate sedation for elective upper endoscopy with balanced propofol versus fentanyl and midazolam alone: a randomized clinical trial. Endoscopy. 2012;44:13–20. doi:10.1055/s-0031-1291421.CrossRefPubMed Levitzky BE, Lopez R, Dumot JA, Vargo JJ. Moderate sedation for elective upper endoscopy with balanced propofol versus fentanyl and midazolam alone: a randomized clinical trial. Endoscopy. 2012;44:13–20. doi:10.​1055/​s-0031-1291421.CrossRefPubMed
4.
Zurück zum Zitat Gross JB, Bailey PI, Connis RT, et al. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96:1004–17.CrossRef Gross JB, Bailey PI, Connis RT, et al. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96:1004–17.CrossRef
6.
Zurück zum Zitat Heuss LT, Chhajed PN, Schnieper P, Hirt T, Beglinger C. Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip. Digestion. 2004;70(3):152–8. doi:10.1159/000081515.CrossRefPubMed Heuss LT, Chhajed PN, Schnieper P, Hirt T, Beglinger C. Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip. Digestion. 2004;70(3):152–8. doi:10.​1159/​000081515.CrossRefPubMed
7.
Zurück zum Zitat Chhajed PN, Heuss LT, Tamm M. Cutaneous carbon dioxide monitoring in adults. Curr Opin Anaesthesiol. 2004;17(6):521–5.CrossRefPubMed Chhajed PN, Heuss LT, Tamm M. Cutaneous carbon dioxide monitoring in adults. Curr Opin Anaesthesiol. 2004;17(6):521–5.CrossRefPubMed
9.
Zurück zum Zitat Eisenbacher S, Heard L. Capnography in the gastroenterology lab. Gastroenterol Nurs. 2005;28(2):99–105.CrossRefPubMed Eisenbacher S, Heard L. Capnography in the gastroenterology lab. Gastroenterol Nurs. 2005;28(2):99–105.CrossRefPubMed
10.
Zurück zum Zitat Soto RG, Fu ES, Vila H Jr, Miguel RV. Capnography accurately detects apnea during monitored anesthesia care. Anesth Analg. 2004;99(2):379–82.CrossRefPubMed Soto RG, Fu ES, Vila H Jr, Miguel RV. Capnography accurately detects apnea during monitored anesthesia care. Anesth Analg. 2004;99(2):379–82.CrossRefPubMed
11.
Zurück zum Zitat Vargo JJ, Zuccaro G, Dumot JA, Conwell DL, Morrow JB, Shay SS. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002;55(7):826–31.CrossRefPubMed Vargo JJ, Zuccaro G, Dumot JA, Conwell DL, Morrow JB, Shay SS. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002;55(7):826–31.CrossRefPubMed
12.
Zurück zum Zitat Lightdale JR, Goldmann DA, Feldman HA, Newburg AR, DiNardo JA, Fox VL. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial. Pediatrics. 2006;117(6):e1170–8. doi:10.1542/peds.2005-1709.CrossRefPubMed Lightdale JR, Goldmann DA, Feldman HA, Newburg AR, DiNardo JA, Fox VL. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial. Pediatrics. 2006;117(6):e1170–8. doi:10.​1542/​peds.​2005-1709.CrossRefPubMed
15.
Zurück zum Zitat Tassaux D, Strasser S, Fonseca S, Dalmas E, Jolliet P. Comparative bench study of triggering, pressurization, and cycling between the home ventilator VPAP II and three ICU ventilators. Intensive Care Med. 2002;28(9):1254–61. doi:10.1007/s00134-002-1421-4.CrossRefPubMed Tassaux D, Strasser S, Fonseca S, Dalmas E, Jolliet P. Comparative bench study of triggering, pressurization, and cycling between the home ventilator VPAP II and three ICU ventilators. Intensive Care Med. 2002;28(9):1254–61. doi:10.​1007/​s00134-002-1421-4.CrossRefPubMed
16.
Zurück zum Zitat Battisti A, Tassaux D, Janssens JP, Michotte JB, Jaber S, Jolliet P. Performance characteristics of 10 home mechanical ventilators in pressure-support mode: a comparative bench study. Chest. 2005;127(5):1784–92. doi:10.1378/chest.127.5.1784.CrossRefPubMed Battisti A, Tassaux D, Janssens JP, Michotte JB, Jaber S, Jolliet P. Performance characteristics of 10 home mechanical ventilators in pressure-support mode: a comparative bench study. Chest. 2005;127(5):1784–92. doi:10.​1378/​chest.​127.​5.​1784.CrossRefPubMed
18.
Zurück zum Zitat Takatori F, Yamamori S, Inoue M, Abe S, Miyasaka K. A novel mainstream capnometer system for non-intubated pediatric patients requiring oxygen administration. Conf Proc IEEE Eng Med Biol Soc. 2011;2011:1189–92. doi:10.1109/IEMBS.2011.6090279.PubMed Takatori F, Yamamori S, Inoue M, Abe S, Miyasaka K. A novel mainstream capnometer system for non-intubated pediatric patients requiring oxygen administration. Conf Proc IEEE Eng Med Biol Soc. 2011;2011:1189–92. doi:10.​1109/​IEMBS.​2011.​6090279.PubMed
19.
Zurück zum Zitat Oberg B, Larsen V. The effect of nasal oxygen flow and catheter position on the accuracy of end-tidal carbon dioxide measurements by a pharyngeal catheter in unintubated, spontaneously breathing subjects. Anaesthesia 1995;50(8):695–8.CrossRefPubMed Oberg B, Larsen V. The effect of nasal oxygen flow and catheter position on the accuracy of end-tidal carbon dioxide measurements by a pharyngeal catheter in unintubated, spontaneously breathing subjects. Anaesthesia 1995;50(8):695–8.CrossRefPubMed
Metadaten
Titel
Accuracy of CO2 monitoring via nasal cannulas and oral bite blocks during sedation for esophagogastroduodenoscopy
verfasst von
Kuo-Chen Chang
Joe Orr
Wei-Chih Hsu
Lu Yu
Mei-Yung Tsou
Dwayne R. Westenskow
Chien-Kun Ting
Publikationsdatum
01.04.2016
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 2/2016
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9696-5

Weitere Artikel der Ausgabe 2/2016

Journal of Clinical Monitoring and Computing 2/2016 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.