Abstract

Purpose

Type 3 home study (HS) monitors do not detect cortical arousal-related hypopneas and may therefore underestimate the polysomnography (PSG)-based apnea-hypopnea index (AHI). Our aim was to test the hypothesis that scoring hypopneas using heart rate accelerations as a surrogate marker for cortical arousal (autonomic hypopnea; AnH) improves the accuracy of HS for OSA diagnosis, using PSG AHI as the diagnostic gold standard.

Methods

We retrospectively identified patients referred for OSA who underwent complete PSG following an initial inconclusive HS. Respiratory events were scored using AASM research (Chicago) criteria with additional HS scoring for AnH, defined as hypopneas based on flow criteria associated with an increase in pulse oximetry-derived heart rate ≥ 6 beats/min.

Results

A total of 178 patients met inclusion criteria, with mean (±SD) HS AHI = 4.4 ± 4.2/h, which increased to 8.5 ± 5.3/h with AnH scoring. The hypopnea arousal index on subsequent PSG was 7.6 ± 7.7/h, with total AHI 15.6 ± 11.9/h. Bland-Altman analysis showed improved agreement between HS and PSG AHI (mean difference 11.2/h (95%CI 33.6, − 11.1) without vs. 7.2/h (95%CI 29.6, − 15.4) with AnH scoring). Overall diagnostic accuracy was improved with AnH scoring as reflected by an increased area under the receiver-operating characteristic curve for AHI thresholds of 10 and 15 events/h.

Conclusions

In this retrospective analysis, the diagnostic accuracy of type 3 HS was improved by the inclusion of hypopnea-associated heart rate increases as a surrogate marker of arousal. Prospective studies are warranted to evaluate the impact of AnH scoring on clinical decision-making and patient outcomes.
Literatur
6.
Zurück zum Zitat Guilleminault C, Connolly S, Winkle R, Melvin K, Tilkian A (1984) Cyclical variation of the heart rate in sleep apnoea syndrome. Mechanisms, and usefulness of 24 h electrocardiography as a screening technique. Lancet (London, England) 1(8369):126–131CrossRef Guilleminault C, Connolly S, Winkle R, Melvin K, Tilkian A (1984) Cyclical variation of the heart rate in sleep apnoea syndrome. Mechanisms, and usefulness of 24 h electrocardiography as a screening technique. Lancet (London, England) 1(8369):126–131CrossRef
7.
Zurück zum Zitat Adachi H, Mikami A, Kumano-go T, Suganuma N, Matsumoto H, Shigedo Y, Sugita Y, Takeda M (2003) Clinical significance of pulse rate rise during sleep as a screening marker for the assessment of sleep fragmentation in sleep-disordered breathing. Sleep Med 4(6):537–542CrossRefPubMed Adachi H, Mikami A, Kumano-go T, Suganuma N, Matsumoto H, Shigedo Y, Sugita Y, Takeda M (2003) Clinical significance of pulse rate rise during sleep as a screening marker for the assessment of sleep fragmentation in sleep-disordered breathing. Sleep Med 4(6):537–542CrossRefPubMed
9.
Zurück zum Zitat Pitson DJ, Stradling JR (1998) Autonomic markers of arousal during sleep in patients undergoing investigation for obstructive sleep apnoea, their relationship to EEG arousals, respiratory events and subjective sleepiness. J Sleep Res 7(1):53–59CrossRefPubMed Pitson DJ, Stradling JR (1998) Autonomic markers of arousal during sleep in patients undergoing investigation for obstructive sleep apnoea, their relationship to EEG arousals, respiratory events and subjective sleepiness. J Sleep Res 7(1):53–59CrossRefPubMed
10.
Zurück zum Zitat Kapur VK, Auckley DH, Chowdhuri S, Kuhlmann DC, Mehra R, Ramar K, Harrod CG (2017) Clinical practice guideline for diagnostic testing for adult obstructive sleep apnea: an American Academy of sleep medicine clinical practice guideline. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 13(3):479–504. https://doi.org/10.5664/jcsm.6506 CrossRef Kapur VK, Auckley DH, Chowdhuri S, Kuhlmann DC, Mehra R, Ramar K, Harrod CG (2017) Clinical practice guideline for diagnostic testing for adult obstructive sleep apnea: an American Academy of sleep medicine clinical practice guideline. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 13(3):479–504. https://​doi.​org/​10.​5664/​jcsm.​6506 CrossRef
11.
Zurück zum Zitat Collop NA, Tracy SL, Kapur V, Mehra R, Kuhlmann D, Fleishman SA, Ojile JM (2011) Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation. J Clin Sleep Medicine : JCSM : Off Publ Am Acad Sleep Med 7(5):531–548. https://doi.org/10.5664/jcsm.1328 CrossRef Collop NA, Tracy SL, Kapur V, Mehra R, Kuhlmann D, Fleishman SA, Ojile JM (2011) Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation. J Clin Sleep Medicine : JCSM : Off Publ Am Acad Sleep Med 7(5):531–548. https://​doi.​org/​10.​5664/​jcsm.​1328 CrossRef
12.
Zurück zum Zitat Flemons WW, Littner MR, Rowley JA, Gay P, Anderson WM, Hudgel DW, McEvoy RD, Loube DI (2003) Home diagnosis of sleep apnea: a systematic review of the literature. An evidence review cosponsored by the American Academy of sleep medicine, the American College of Chest Physicians, and the American Thoracic Society. Chest 124(4):1543–1579CrossRefPubMed Flemons WW, Littner MR, Rowley JA, Gay P, Anderson WM, Hudgel DW, McEvoy RD, Loube DI (2003) Home diagnosis of sleep apnea: a systematic review of the literature. An evidence review cosponsored by the American Academy of sleep medicine, the American College of Chest Physicians, and the American Thoracic Society. Chest 124(4):1543–1579CrossRefPubMed
13.
Zurück zum Zitat Masa JF, Corral J, Pereira R, Duran-Cantolla J, Cabello M, Hernandez-Blasco L, Monasterio C, Alonso A, Chiner E, Zamorano J, Aizpuru F, Montserrat JM (2011) Therapeutic decision-making for sleep apnea and hypopnea syndrome using home respiratory polygraphy: a large multicentric study. Am J Respir Crit Care Med 184(8):964–971. https://doi.org/10.1164/rccm.201103-0428OC CrossRefPubMed Masa JF, Corral J, Pereira R, Duran-Cantolla J, Cabello M, Hernandez-Blasco L, Monasterio C, Alonso A, Chiner E, Zamorano J, Aizpuru F, Montserrat JM (2011) Therapeutic decision-making for sleep apnea and hypopnea syndrome using home respiratory polygraphy: a large multicentric study. Am J Respir Crit Care Med 184(8):964–971. https://​doi.​org/​10.​1164/​rccm.​201103-0428OC CrossRefPubMed
16.
Zurück zum Zitat Catcheside PG, Chiong SC, Mercer J, Saunders NA, McEvoy RD (2002) Noninvasive cardiovascular markers of acoustically induced arousal from non-rapid-eye-movement sleep. Sleep 25(7):797–804CrossRefPubMed Catcheside PG, Chiong SC, Mercer J, Saunders NA, McEvoy RD (2002) Noninvasive cardiovascular markers of acoustically induced arousal from non-rapid-eye-movement sleep. Sleep 25(7):797–804CrossRefPubMed
18.
Zurück zum Zitat Penzel T, McNames J, Murray A, de Chazal P, Moody G, Raymond B (2002) Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings. Med Biol Eng Comput 40(4):402–407CrossRefPubMed Penzel T, McNames J, Murray A, de Chazal P, Moody G, Raymond B (2002) Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings. Med Biol Eng Comput 40(4):402–407CrossRefPubMed
19.
Zurück zum Zitat Heneghan C, Chua CP, Garvey JF, de Chazal P, Shouldice R, Boyle P, McNicholas WT (2008) A portable automated assessment tool for sleep apnea using a combined Holter-oximeter. Sleep 31(10):1432–1439PubMedPubMedCentral Heneghan C, Chua CP, Garvey JF, de Chazal P, Shouldice R, Boyle P, McNicholas WT (2008) A portable automated assessment tool for sleep apnea using a combined Holter-oximeter. Sleep 31(10):1432–1439PubMedPubMedCentral
21.
Zurück zum Zitat Ayappa I, Norman RG, Seelall V, Rapoport DM (2008) Validation of a self-applied unattended monitor for sleep disordered breathing. J Clin Sleep Med : JCSM : Off Publ Am Acad Sleep Med 4(1):26–37 Ayappa I, Norman RG, Seelall V, Rapoport DM (2008) Validation of a self-applied unattended monitor for sleep disordered breathing. J Clin Sleep Med : JCSM : Off Publ Am Acad Sleep Med 4(1):26–37
24.
Zurück zum Zitat Chowdhuri S, Quan SF, Almeida F, Ayappa I, Batool-Anwar S, Budhiraja R, Cruse PE, Drager LF, Griss B, Marshall N, Patel SR, Patil S, Knight SL, Rowley JA, Slyman A (2016) An official American Thoracic Society research statement: impact of mild obstructive sleep apnea in adults. Am J Respir Crit Care Med 193(9):e37–e54. https://doi.org/10.1164/rccm.201602-0361ST CrossRefPubMed Chowdhuri S, Quan SF, Almeida F, Ayappa I, Batool-Anwar S, Budhiraja R, Cruse PE, Drager LF, Griss B, Marshall N, Patel SR, Patil S, Knight SL, Rowley JA, Slyman A (2016) An official American Thoracic Society research statement: impact of mild obstructive sleep apnea in adults. Am J Respir Crit Care Med 193(9):e37–e54. https://​doi.​org/​10.​1164/​rccm.​201602-0361ST CrossRefPubMed
26.
Zurück zum Zitat Masa JF, Corral J, Gomez de Terreros J, Duran-Cantolla J, Cabello M, Hernandez-Blasco L, Monasterio C, Alonso A, Chiner E, Aizpuru F, Zamorano J, Cano R, Montserrat JM, Garcia-Ledesma E, Pereira R, Cancelo L, Martinez A, Sacristan L, Salord N, Carrera M, Sancho-Chust JN, Embid C (2013) Significance of including a surrogate arousal for sleep apnea-hypopnea syndrome diagnosis by respiratory polygraphy. Sleep 36(2):249–257. https://doi.org/10.5665/sleep.2384 CrossRefPubMedPubMedCentral Masa JF, Corral J, Gomez de Terreros J, Duran-Cantolla J, Cabello M, Hernandez-Blasco L, Monasterio C, Alonso A, Chiner E, Aizpuru F, Zamorano J, Cano R, Montserrat JM, Garcia-Ledesma E, Pereira R, Cancelo L, Martinez A, Sacristan L, Salord N, Carrera M, Sancho-Chust JN, Embid C (2013) Significance of including a surrogate arousal for sleep apnea-hypopnea syndrome diagnosis by respiratory polygraphy. Sleep 36(2):249–257. https://​doi.​org/​10.​5665/​sleep.​2384 CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Prasad B, Usmani S, Steffen AD, Van Dongen HP, Pack FM, Strakovsky I, Staley B, Dinges D, Maislin G, Pack AI, Weaver TE (2016) Short-term variability in apnea-hypopnea index during extended home portable monitoring. J Clin Sleep Med : JCSM : Off Publ Am Acad Sleep Med 12(6):855–863. https://doi.org/10.5664/jcsm.5886 CrossRef Prasad B, Usmani S, Steffen AD, Van Dongen HP, Pack FM, Strakovsky I, Staley B, Dinges D, Maislin G, Pack AI, Weaver TE (2016) Short-term variability in apnea-hypopnea index during extended home portable monitoring. J Clin Sleep Med : JCSM : Off Publ Am Acad Sleep Med 12(6):855–863. https://​doi.​org/​10.​5664/​jcsm.​5886 CrossRef
Metadaten
Titel
Accuracy of portable devices in sleep apnea using oximetry-derived heart rate increases as a surrogate arousal marker
verfasst von
Philippe Lachapelle
Juan Cascon
Sushmita Pamidi
R. John Kimoff
Publikationsdatum
15.08.2018
Verlag
Springer International Publishing
Erschienen in
Sleep and Breathing / Ausgabe 2/2019
Print ISSN: 1520-9512
Elektronische ISSN: 1522-1709
DOI
https://doi.org/10.1007/s11325-018-1708-5

Weitere Artikel der Ausgabe 2/2019

Sleep and Breathing 2/2019 Zur Ausgabe

Sleep and Breathing Physiology and Disorders • Letter to the Editors

The use of mandibular advancement devices in obstructive sleep apnea: a proven and effective therapy

Sleep Breathing Physiology and Disorders • Original Article

Cognitive impairment and sleep disturbances after minor ischemic stroke

Sleep and Breathing Physiology and Disorders • Original Article

Obstructive sleep apnea in pregnancy: performance of a rapid screening tool

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.