Accuracy of the Apple Watch iECG in Children With and Without Congenital Heart Disease

verfasst von: M. Kobel, P. Kalden, A. Michaelis, F. Markel, S. Mensch, M. Weidenbach, F. T. Riede, F. Löffelbein, A. Bollmann, A. S. Shamloo, I. Dähnert, R. A. Gebauer, C. Paech

Erschienen in: Pediatric Cardiology | Ausgabe 1/2022

Einloggen, um Zugang zu erhalten

Abstract

The development of smart technologies paves the way for new diagnostic modalities. The Apple Watch provides an FDA approved iECG function for users from 22 years of age. Yet, there are currently no data on the accuracy of the Apple Watch iECG in children. While arrhythmias are a frequent phenomenon in children, especially those with congenital heart disease, the increasing spread of smart watches provides the possibility to use a smart watch as mobile event recorder in case of suspected arrhythmia. This may help to provide valuable information to the treating physician, without having the patient to come to the hospital. Necessary treatment adjustments might be provided without timely delay. The aim of this study was therefore to evaluate the agreement of measured values of rate, interval, and amplitude with those obtained by a diagnostic quality ECG recording to an Apple Watch iECG in children with and without congenital heart disease. In this prospective, single-arm study, consecutive patients aged 0–16 years presenting to the Heart Center Leipzig, Department for pediatric cardiology were included. After obtaining informed consent from participants’ parents, a 12-lead ECG and an iECG using an Apple Watch were performed. Cardiac rhythm was classified, amplitudes and timing intervals were measured and analyzed in iECG and 12-lead ECG for comparability. These measurements were performed blinded to the patients’ history by two experienced pediatric cardiologists. Patient demographic data, medical and cardiac history were assessed. 215 children between 0 and 16 years were enrolled. Comparison of amplitudes and timing intervals between ECG and iECG showed excellent correlation (K > 0.7, p < 0.01) in all parameters except for the p-waves. Automatic rhythm classification was inferior to manual interpretation of ECG / iECG, while iECG interpretation was reliable in 94.86% of cases. The study demonstrates equal quality of the Apple Watch derived iECG compared to a lead I in 12-lead ECG in children of all age groups and independent from cardiac anatomy.
Literatur
1.
Zurück zum Zitat Samol A, Bischof K, Luani B, Pascut D, Wiemer M, Kaese S (2019) Single-lead ECG recordings including Einthoven and Wilson leads by a smartwatch: a new era of patient directed early ECG differential diagnosis of cardiac diseases? Sensors 19(20):4377CrossRef Samol A, Bischof K, Luani B, Pascut D, Wiemer M, Kaese S (2019) Single-lead ECG recordings including Einthoven and Wilson leads by a smartwatch: a new era of patient directed early ECG differential diagnosis of cardiac diseases? Sensors 19(20):4377CrossRef
2.
Zurück zum Zitat Drexler M, Elsner C, Gabelmann V, Gori T, Münzel T (2020) Apple Watch detecting coronary ischaemia during chest pain episodes or an apple a day may keep myocardial infarction away. Eur Heart J 2020:290 Drexler M, Elsner C, Gabelmann V, Gori T, Münzel T (2020) Apple Watch detecting coronary ischaemia during chest pain episodes or an apple a day may keep myocardial infarction away. Eur Heart J 2020:290
4.
Zurück zum Zitat Berger S, Dubin AM (2010) Arrhythmogenic forms of heart failure in children. Heart Fail Clin 6(4):471–481CrossRef Berger S, Dubin AM (2010) Arrhythmogenic forms of heart failure in children. Heart Fail Clin 6(4):471–481CrossRef
5.
Zurück zum Zitat Siddeek H, Fisher K, McMakin S, Bass JL, Cortez D (2020) AVNRT captured by Apple Watch Series 4: can the Apple watch be used as an event monitor? Noninvasive Electrocardiol 2020:e12742 Siddeek H, Fisher K, McMakin S, Bass JL, Cortez D (2020) AVNRT captured by Apple Watch Series 4: can the Apple watch be used as an event monitor? Noninvasive Electrocardiol 2020:e12742
6.
Zurück zum Zitat Yerasi C, O’Donoghue S, Satler LF, Waksman R (2020) Apple Watch detecting high-grade block after transcatheter aortic valve implantation. Eur Heart J 41(10):1096CrossRef Yerasi C, O’Donoghue S, Satler LF, Waksman R (2020) Apple Watch detecting high-grade block after transcatheter aortic valve implantation. Eur Heart J 41(10):1096CrossRef
7.
Zurück zum Zitat van der Linde D, Konings EE, Slager MA, Witsenburg M, Helbing WA, Takkenberg JJ (2011) Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis. J Am Coll Cardiol 58(21):2241–2247CrossRef van der Linde D, Konings EE, Slager MA, Witsenburg M, Helbing WA, Takkenberg JJ (2011) Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis. J Am Coll Cardiol 58(21):2241–2247CrossRef
8.
Zurück zum Zitat Kline J, Costantini O (2019) Arrhythmias in congenital heart disease. Med Clin North Am 103(5):945–956CrossRef Kline J, Costantini O (2019) Arrhythmias in congenital heart disease. Med Clin North Am 103(5):945–956CrossRef
9.
Zurück zum Zitat Behzadi A, Shamloo AS, Mouratis K, Hindricks G, Arya A, Bollmann A (2020) Feasibility and reliability of SmartWatch to obtain 3-lead electrocardiogram recordings. Sensors 20(18):5074CrossRef Behzadi A, Shamloo AS, Mouratis K, Hindricks G, Arya A, Bollmann A (2020) Feasibility and reliability of SmartWatch to obtain 3-lead electrocardiogram recordings. Sensors 20(18):5074CrossRef
Metadaten
Titel
Accuracy of the Apple Watch iECG in Children With and Without Congenital Heart Disease
verfasst von
M. Kobel
P. Kalden
A. Michaelis
F. Markel
S. Mensch
M. Weidenbach
F. T. Riede
F. Löffelbein
A. Bollmann
A. S. Shamloo
I. Dähnert
R. A. Gebauer
C. Paech
Publikationsdatum
01.09.2021
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 1/2022
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-021-02715-w

Kompaktes Leitlinien-Wissen Innere Medizin (Link öffnet in neuem Fenster)

Mit medbee Pocketcards schnell und sicher entscheiden.
Leitlinien-Wissen kostenlos und immer griffbereit auf ihrem Desktop, Handy oder Tablet.

Neu im Fachgebiet Kardiologie

ePA: Entlastung oder Mehrarbeit?

Die elektronische Patientenakte (ePA) soll das Gesundheitswesen revolutionieren. Mit über 2000 Krankenhäusern und mehr als 100.000 ärztlichen Praxen ist sie eines der größten Digitalisierungsprojekte Europas, wie Florian Fuhrmann präsentierte. Während die Politik die ePA als „Gamechanger“ feiert, zeigt sich in der Praxis ein anderes Bild. 

Herzkongress ACC 2025: Diese neuen Studien stehen im Brennpunkt

Vom 29. bis 31. März findet in Chicago der Herzkongress ACC 2025 statt. Die Liste der als „Late-breaking Trials“ in den Blickpunkt gerückten neuen Studien zu wichtigen kardiologischen Themen ist wieder einmal lang.

Blutdruck am Belastungsende zeigt kardiovaskuläres Risiko

Diverse Blutdruckparameter während der Ergometrie sind schon auf ihre Aussagekraft, Mortalität und kardiovaskuläres Risiko betreffend, hin abgeklopft worden. Nun hat auch das Druckverhalten am Ende der Belastung im Fokus einer Studie gestanden.

Lp(a) wird zu selten gemessen

Laut europäischer Dyslipidämie-Leitlinie sollte die Bestimmung der Serumkonzentration von Lipoprotein (a) mindestens einmal im Leben jedes Erwachsenen erwogen werden. Tatsächlich wird die Messung selbst kardiovaskulär gefährdeten Personen nur selten zuteil.

EKG Essentials: EKG befunden mit System (Link öffnet in neuem Fenster)

In diesem CME-Kurs können Sie Ihr Wissen zur EKG-Befundung anhand von zwölf Video-Tutorials auffrischen und 10 CME-Punkte sammeln.
Praxisnah, relevant und mit vielen Tipps & Tricks vom Profi.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.