Skip to main content
Erschienen in: European Radiology 6/2007

01.06.2007 | Gastrointestinal

Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

verfasst von: Hans Scheffel, Thomas Pfammatter, Stefan Wildi, Peter Bauerfeind, Borut Marincek, Hatem Alkadhi

Erschienen in: European Radiology | Ausgabe 6/2007

Einloggen, um Zugang zu erhalten

Abstract

This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding.
Literatur
1.
Zurück zum Zitat Manning-Dimmitt LL, Dimmitt SG, Wilson GR (2005) Diagnosis of gastrointestinal bleeding in adults. Am Fam Physician 71:1339–1346PubMed Manning-Dimmitt LL, Dimmitt SG, Wilson GR (2005) Diagnosis of gastrointestinal bleeding in adults. Am Fam Physician 71:1339–1346PubMed
2.
Zurück zum Zitat Barkun A, Bardou M, Marshall JK (2003) Consensus recommendations for managing patients with nonvariceal upper gastrointestinal bleeding. Ann Intern Med 139:843–857PubMed Barkun A, Bardou M, Marshall JK (2003) Consensus recommendations for managing patients with nonvariceal upper gastrointestinal bleeding. Ann Intern Med 139:843–857PubMed
3.
Zurück zum Zitat Palmer KR (2002) Non-variceal upper gastrointestinal haemorrhage: guidelines. Gut 51 Suppl 4:iv1–iv6 Palmer KR (2002) Non-variceal upper gastrointestinal haemorrhage: guidelines. Gut 51 Suppl 4:iv1–iv6
4.
Zurück zum Zitat Yoon W et al (2006) Acute massive gastrointestinal bleeding: detection and localization with arterial phase multi-detector row helical CT. Radiology 239:160–167PubMedCrossRef Yoon W et al (2006) Acute massive gastrointestinal bleeding: detection and localization with arterial phase multi-detector row helical CT. Radiology 239:160–167PubMedCrossRef
5.
Zurück zum Zitat Tew K, Davies RP, Jadun CK, Kew J (2004) MDCT of acute lower gastrointestinal bleeding. AJR Am J Roentgenol 182:427–430PubMed Tew K, Davies RP, Jadun CK, Kew J (2004) MDCT of acute lower gastrointestinal bleeding. AJR Am J Roentgenol 182:427–430PubMed
6.
Zurück zum Zitat Miller FH, Hwang CM (2004) An initial experience: using helical CT imaging to detect obscure gastrointestinal bleeding. Clin Imaging 28:245–251PubMedCrossRef Miller FH, Hwang CM (2004) An initial experience: using helical CT imaging to detect obscure gastrointestinal bleeding. Clin Imaging 28:245–251PubMedCrossRef
7.
Zurück zum Zitat Rajan R, Dhar P, Praseedom RK, Sudhindran S, Moorthy S (2004) Role of contrast CT in acute lower gastrointestinal bleeding. Dig Surg 21:293–296PubMedCrossRef Rajan R, Dhar P, Praseedom RK, Sudhindran S, Moorthy S (2004) Role of contrast CT in acute lower gastrointestinal bleeding. Dig Surg 21:293–296PubMedCrossRef
8.
Zurück zum Zitat Ernst O, Bulois P, Saint-Drenant S, Leroy C, Paris JC, Sergent G (2003) Helical CT in acute lower gastrointestinal bleeding. Eur Radiol 13:114–117PubMed Ernst O, Bulois P, Saint-Drenant S, Leroy C, Paris JC, Sergent G (2003) Helical CT in acute lower gastrointestinal bleeding. Eur Radiol 13:114–117PubMed
9.
Zurück zum Zitat Ettorre GC, Francioso G, Garribba AP, Fracella MR, Greco A, Farchi G (1997) Helical CT angiography in gastrointestinal bleeding of obscure origin. AJR Am J Roentgenol 168:727–731PubMed Ettorre GC, Francioso G, Garribba AP, Fracella MR, Greco A, Farchi G (1997) Helical CT angiography in gastrointestinal bleeding of obscure origin. AJR Am J Roentgenol 168:727–731PubMed
10.
Zurück zum Zitat Frauenfelder T, Wildermuth S, Marincek B, Boehm T (2004) Nontraumatic emergent abdominal vascular conditions: advantages of multi-detector row CT and three-dimensional imaging. Radiographics 24:481–496PubMedCrossRef Frauenfelder T, Wildermuth S, Marincek B, Boehm T (2004) Nontraumatic emergent abdominal vascular conditions: advantages of multi-detector row CT and three-dimensional imaging. Radiographics 24:481–496PubMedCrossRef
11.
Zurück zum Zitat Roos JE, Willmann JK, Hilfiker PR (2002) Secondary aortoenteric fistula: active bleeding detected with multi-detector-row CT. Eur Radiol 12 Suppl 3:S196–200PubMed Roos JE, Willmann JK, Hilfiker PR (2002) Secondary aortoenteric fistula: active bleeding detected with multi-detector-row CT. Eur Radiol 12 Suppl 3:S196–200PubMed
12.
Zurück zum Zitat Leschka S, Alkadhi H, Wildermuth S, Marincek B (2005) Multi-detector computed tomography of acute abdomen. Eur Radiol 15:2435–2447PubMedCrossRef Leschka S, Alkadhi H, Wildermuth S, Marincek B (2005) Multi-detector computed tomography of acute abdomen. Eur Radiol 15:2435–2447PubMedCrossRef
13.
Zurück zum Zitat Leitman IM, Paull DE, Shires GT 3rd (1989) Evaluation and management of massive lower gastrointestinal hemorrhage. Ann Surg 209:175–180PubMedCrossRef Leitman IM, Paull DE, Shires GT 3rd (1989) Evaluation and management of massive lower gastrointestinal hemorrhage. Ann Surg 209:175–180PubMedCrossRef
14.
Zurück zum Zitat Kuhle WG, Sheiman RG (2003) Detection of active colonic hemorrhage with use of helical CT: findings in a swine model. Radiology 228:743–752PubMedCrossRef Kuhle WG, Sheiman RG (2003) Detection of active colonic hemorrhage with use of helical CT: findings in a swine model. Radiology 228:743–752PubMedCrossRef
15.
Zurück zum Zitat Yoon W, Jeong YY, Kim JK (2006) Acute gastrointestinal bleeding: contrast-enhanced MDCT. Abdom Imaging 31:1–8PubMedCrossRef Yoon W, Jeong YY, Kim JK (2006) Acute gastrointestinal bleeding: contrast-enhanced MDCT. Abdom Imaging 31:1–8PubMedCrossRef
Metadaten
Titel
Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT
verfasst von
Hans Scheffel
Thomas Pfammatter
Stefan Wildi
Peter Bauerfeind
Borut Marincek
Hatem Alkadhi
Publikationsdatum
01.06.2007
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 6/2007
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0514-9

Weitere Artikel der Ausgabe 6/2007

European Radiology 6/2007 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.