Skip to main content

25.10.2019

Additive value of split-bolus single-phase CT scan protocol for preoperative assessment of lung cancer patients referred for video-assisted thoracic surgery

Erschienen in: Radiological Physics and Technology | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

We aimed to assess the additive value of the split-bolus single-phase computed tomography (CT) scan protocol to preoperatively assess patients with lung cancer, who were referred for video-assisted thoracic surgery, when compared to a standard staging CT protocol. We included 160 patients with lung cancer who underwent a split-bolus single-phase CT scan protocol (split-bolus protocol), which can acquire whole-body staging CT and pulmonary artery-vein separation CT angiography (PA–PV CTA) in a single acquisition and 160 patients who underwent whole-body staging CT (standard protocol). We compared the quality of the staging CT images of hepatic parenchyma, portal vein, and hepatic vein between both protocols. We also investigated image quality on PA–PV CTA images in the split-bolus protocol and recorded the number of patients that underwent the 3D PA–PV CTA imaging process. The split-bolus protocol for staging CT images demonstrated a slightly higher enhancement with regard to the hepatic parenchyma (p = 0.007) and hepatic vein (p = 0.006) than the standard protocol. There was no significant difference in the quality of the staging CT images between both protocols (p = 0.067). The mean CT number for the main pulmonary artery and the left atrium for the PA–PV CTA images in the split-bolus protocol were 289.1 HU and 172.8 HU, respectively. Among the images associated with the split-bolus protocol, 98.1% were of appropriate quality for 3D PA–PV CTA imaging. The split-bolus protocol is a dose-efficient protocol to acquire the staging CT and PA–PV CTA images in a single session and provides sufficient image quality for preoperative assessment in patients with lung cancer.
Literatur
1.
Zurück zum Zitat Nagayama Y, Nakaura T, Oda S, et al. Value of 100 kVp scan with sinogram-affirmed iterative reconstruction algorithm on a single-source CT system during whole-body CT for radiation and contrast medium dose reduction: an intra-individual feasibility study. Clin Radiol. 2018;73:217.e7–16.CrossRef Nagayama Y, Nakaura T, Oda S, et al. Value of 100 kVp scan with sinogram-affirmed iterative reconstruction algorithm on a single-source CT system during whole-body CT for radiation and contrast medium dose reduction: an intra-individual feasibility study. Clin Radiol. 2018;73:217.e7–16.CrossRef
2.
Zurück zum Zitat Akiba T, Marushima H, Odaka M, et al. Pulmonary vein analysis using three-dimensional computed tomography angiography for thoracicsurgery. Gen Thorac Cardiovasc Surg. 2010;58(7):331–5.CrossRef Akiba T, Marushima H, Odaka M, et al. Pulmonary vein analysis using three-dimensional computed tomography angiography for thoracicsurgery. Gen Thorac Cardiovasc Surg. 2010;58(7):331–5.CrossRef
3.
Zurück zum Zitat Galluzzo A, Fatica F, Caternicchia F, et al. 3D CT scan for perioperative identification of anatomical variations of lungs. Future Oncol. 2016;12(23):27–30.CrossRef Galluzzo A, Fatica F, Caternicchia F, et al. 3D CT scan for perioperative identification of anatomical variations of lungs. Future Oncol. 2016;12(23):27–30.CrossRef
4.
Zurück zum Zitat Fukuhara K, Akashi A, Nakane S, et al. Preoperative assessment of the pulmonary artery by three-dimensional computed tomography before video-assisted thoracic surgery lobectomy. Eur J Cardiothorac Surg. 2008;34(4):875–7.CrossRef Fukuhara K, Akashi A, Nakane S, et al. Preoperative assessment of the pulmonary artery by three-dimensional computed tomography before video-assisted thoracic surgery lobectomy. Eur J Cardiothorac Surg. 2008;34(4):875–7.CrossRef
5.
Zurück zum Zitat Hagiwara M, Shimada Y, Kato Y, et al. High-quality 3-dimensional image simulation for pulmonary lobectomy and segmentectomy: results of preoperative assessment of pulmonary vessels and short-term surgical outcomes in consecutive patients undergoing video-assisted thoracic surgery. Eur J Cardiothorac Surg. 2014;46:e120–6.CrossRef Hagiwara M, Shimada Y, Kato Y, et al. High-quality 3-dimensional image simulation for pulmonary lobectomy and segmentectomy: results of preoperative assessment of pulmonary vessels and short-term surgical outcomes in consecutive patients undergoing video-assisted thoracic surgery. Eur J Cardiothorac Surg. 2014;46:e120–6.CrossRef
6.
Zurück zum Zitat Nagashima T, Shimizu K, Ohtaki Y, et al. An analysis of variations in the bronchovascular pattern of the right upper lobe using three-dimensional CT angiography and bronchography. Gen Thorac Cardiovasc Surg. 2015;63:354–60.CrossRef Nagashima T, Shimizu K, Ohtaki Y, et al. An analysis of variations in the bronchovascular pattern of the right upper lobe using three-dimensional CT angiography and bronchography. Gen Thorac Cardiovasc Surg. 2015;63:354–60.CrossRef
7.
Zurück zum Zitat Yang Q, Xie B, Hu M, et al. Thoracoscopic anatomic pulmonary segmentectomy: a 3-dimensional guided imaging system for lung operations. Interact Cardiovasc Thorac Surg. 2016;23:183–9.CrossRef Yang Q, Xie B, Hu M, et al. Thoracoscopic anatomic pulmonary segmentectomy: a 3-dimensional guided imaging system for lung operations. Interact Cardiovasc Thorac Surg. 2016;23:183–9.CrossRef
8.
Zurück zum Zitat Sumitomo R, Fukui T, Otake Y, et al. Video-assisted thoracoscopic lobectomy with an anomalous pulmonary vein. J Thorac Cardiovasc Surg. 2016;152:1398–9.CrossRef Sumitomo R, Fukui T, Otake Y, et al. Video-assisted thoracoscopic lobectomy with an anomalous pulmonary vein. J Thorac Cardiovasc Surg. 2016;152:1398–9.CrossRef
9.
Zurück zum Zitat Mun M, Okumura S, Nakao M, Matsuura M, et al. Indocyanine green fluorescence-navigated thoracoscopic anatomical segmentectomy. J Vis Surg. 2017;2017:3–80. Mun M, Okumura S, Nakao M, Matsuura M, et al. Indocyanine green fluorescence-navigated thoracoscopic anatomical segmentectomy. J Vis Surg. 2017;2017:3–80.
10.
Zurück zum Zitat Sato T, Date H. 3D CT simulation in minimally invasive thoracic surgery. J Vis Surg. 2017;2017:3–26. Sato T, Date H. 3D CT simulation in minimally invasive thoracic surgery. J Vis Surg. 2017;2017:3–26.
11.
Zurück zum Zitat Shimizu K, Nakazawa S, Nagashima T, et al. 3D-CT anatomy for VATS segmentectomy. J Vis Surg. 2017;2017:3–88. Shimizu K, Nakazawa S, Nagashima T, et al. 3D-CT anatomy for VATS segmentectomy. J Vis Surg. 2017;2017:3–88.
12.
Zurück zum Zitat Ye M, Shen J, Kong M, et al. Video-assisted thoracoscopic surgery right upper lobectomy in a situs inversus totalis patient. J Thorac Dis. 2017;9(11):E1018–20.CrossRef Ye M, Shen J, Kong M, et al. Video-assisted thoracoscopic surgery right upper lobectomy in a situs inversus totalis patient. J Thorac Dis. 2017;9(11):E1018–20.CrossRef
13.
Zurück zum Zitat Yao F, Wang J, Yao J, et al. Three-dimensional image reconstruction with free open-source OsiriX software in video-assisted thoracoscopic lobectomy and segmentectomy. Int J Surg Oncol. 2017;39:16–22. Yao F, Wang J, Yao J, et al. Three-dimensional image reconstruction with free open-source OsiriX software in video-assisted thoracoscopic lobectomy and segmentectomy. Int J Surg Oncol. 2017;39:16–22.
14.
Zurück zum Zitat Fourdrain A, Dominicis FD, Blanchard C, et al. Three-dimensional CT angiography of anatomic variations in the pulmonary arterial tree. Surg Radiol Anat. 2018;40:45–53.CrossRef Fourdrain A, Dominicis FD, Blanchard C, et al. Three-dimensional CT angiography of anatomic variations in the pulmonary arterial tree. Surg Radiol Anat. 2018;40:45–53.CrossRef
15.
Zurück zum Zitat Schneider CA, Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 years of image analysis. Nat Methods. 2012;9(7):671–5.CrossRef Schneider CA, Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 years of image analysis. Nat Methods. 2012;9(7):671–5.CrossRef
16.
Zurück zum Zitat Jones SE, Wittram C. The indeterminate CT pulmonary angiogram: imaging characteristics and patient clinical outcome. Radiology. 2005;237:329–37.CrossRef Jones SE, Wittram C. The indeterminate CT pulmonary angiogram: imaging characteristics and patient clinical outcome. Radiology. 2005;237:329–37.CrossRef
17.
Zurück zum Zitat Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, et al. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology. 2006;241:899–907.CrossRef Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, et al. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology. 2006;241:899–907.CrossRef
18.
Zurück zum Zitat Bae KT, Tao C, Gürel S, et al. Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography. Radiology. 2007;242:582–9.CrossRef Bae KT, Tao C, Gürel S, et al. Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography. Radiology. 2007;242:582–9.CrossRef
19.
Zurück zum Zitat Heyer CM, Mohr PS, Lemburg SP, et al. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology. 2007;245:577–83.CrossRef Heyer CM, Mohr PS, Lemburg SP, et al. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology. 2007;245:577–83.CrossRef
20.
Zurück zum Zitat Borgen L, Kalra MK, Lærum F, et al. Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT. Acta Radiol. 2012;53:335–42.CrossRef Borgen L, Kalra MK, Lærum F, et al. Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT. Acta Radiol. 2012;53:335–42.CrossRef
21.
Zurück zum Zitat Nakaura T, Awai K, Oda S, et al. Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image quality, and display settings. AJR Am J Roentgenol. 2011;196:1332–8.CrossRef Nakaura T, Awai K, Oda S, et al. Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image quality, and display settings. AJR Am J Roentgenol. 2011;196:1332–8.CrossRef
22.
Zurück zum Zitat Apfaltrer P, Sudarski S, Schneider D, et al. Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. Eur J Radiol. 2014;83:322–8.CrossRef Apfaltrer P, Sudarski S, Schneider D, et al. Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. Eur J Radiol. 2014;83:322–8.CrossRef
23.
Zurück zum Zitat Gill MK, Vijayananthan A, Kumar G, et al. Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality. Quant Imaging Med Surg. 2015;5(4):524–33.PubMedPubMedCentral Gill MK, Vijayananthan A, Kumar G, et al. Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality. Quant Imaging Med Surg. 2015;5(4):524–33.PubMedPubMedCentral
24.
Zurück zum Zitat Meier A, Higashigaito K, Martini K, et al. Dual energy CT pulmonary angiography with 6 g iodine—a propensity score-matched study. PLoS ONE. 2016;11(12):e0167214.CrossRef Meier A, Higashigaito K, Martini K, et al. Dual energy CT pulmonary angiography with 6 g iodine—a propensity score-matched study. PLoS ONE. 2016;11(12):e0167214.CrossRef
25.
Zurück zum Zitat Leithner D, Gruber-Rouh T, Beeres M, et al. 90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism. Br J Radiol. 2018;91:20180269.CrossRef Leithner D, Gruber-Rouh T, Beeres M, et al. 90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism. Br J Radiol. 2018;91:20180269.CrossRef
26.
Zurück zum Zitat Awai K, Hatcho A, Nakayama Y, et al. Simulation of aortic peak enhancement on MDCT using a contrast medium flow phantom: feasibility study. AJR Am J Roentgenol. 2006;186:379–85.CrossRef Awai K, Hatcho A, Nakayama Y, et al. Simulation of aortic peak enhancement on MDCT using a contrast medium flow phantom: feasibility study. AJR Am J Roentgenol. 2006;186:379–85.CrossRef
27.
Zurück zum Zitat Hutchinson BD, Navin P, Marom EM, et al. Overdiagnosis of pulmonary embolism by pulmonary CT angiography. AJR Am J Roentgenol. 2015;205:271–7.CrossRef Hutchinson BD, Navin P, Marom EM, et al. Overdiagnosis of pulmonary embolism by pulmonary CT angiography. AJR Am J Roentgenol. 2015;205:271–7.CrossRef
Metadaten
Titel
Additive value of split-bolus single-phase CT scan protocol for preoperative assessment of lung cancer patients referred for video-assisted thoracic surgery
Publikationsdatum
25.10.2019
Erschienen in
Radiological Physics and Technology / Ausgabe 4/2019
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00541-7

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.