Abstract

Although significant advances in clinical monitoring technology and clinical practice development have taken place in the last several decades, in this editorial we argue that much more still needs to be done. We begin by identifying many of the improvements in perioperative technology that have become available in recent years; these include electroencephalographic depth of anesthesia monitoring, bedside ultrasonography, advanced neuromuscular transmission monitoring systems, and other developments. We then discuss some of the perioperative technical challenges that remain to be satisfactorily addressed, such as products that incorporate poor software design or offer a confusing user interface. Finally we suggest that the journal support initiatives to help remedy this problem by publishing reports on the evaluation of medical equipment as a means to restore the link between clinical research and clinical end-users.
Hinweise
The original version of this article was revised to correct the name of Ashraf A. Dahaba.
A correction to this article is available online at https://​doi.​org/​10.​1186/​s12871-018-0517-5.
Abkürzungen
AMG
Acceleromyogram acceleromyographic
BIS
Bispectral index
ECRI
Emergency care research institute
EEG
Electroencephalogram
ICU
Intensive care unit
KMG
Kinemyogram / kinemyographic
NMT
Neuromuscular transmission
TOF
Train of four
Advances during the last several decades have led to important improvements in clinical monitoring technology and clinical practice development, not only in patients undergoing surgery [16] or in patients being cared for in Intensive Care Units (ICUs) [79] but also in ambulatory patients [10, 11]. These developments have contributed to great improvements in patient safety [3, 57, 1214]. In addition, anesthesiologists world-wide have developed standards for continuous real-time monitoring of hemodynamics, oxygenation, ventilation, neurological status, urine output, core temperature, degree of neuromuscular blockade, as well as other items, all of which have also contributed significantly to patient safety [1517].
Several other innovative developments have also contributed to improving the quality of perioperative care. Checklists, proven to be particularly valuable in the aerospace industry, are now in common use in the operating room and elsewhere [1822]. For example, in a landmark study by Haynes et al. [23], a surgical death rate of 1.5% before the introduction of a surgical checklist fell to 0.8% after, with an inpatient complication rate dropping from a baseline of 11% down to 7% after introduction of the checklist. New approaches to clinical airway management such as airway algorithms [24, 25], video laryngoscopy [2631], extubation catheters [3234] and advanced supraglottic airway devices [3538] are also protecting patients from injury.
In the realm of perioperative cardiac monitoring, the use of conventional and 3D- echocardiography [39, 40] now allows for real-time monitoring of valvular function, ventricular filling, cardiac contractility and other hemodynamic parameters. Additionally, hand-held ultrasound machines are changing how bedside examinations are conducted [4144] (Fig. 1). Clinical early warning algorithms, especially valuable in the perioperative setting to detect the early onset of clinical deterioration, have also proven to be effective in improving patient care [4549].
Another important development concerns the numerous so called “Depth of anesthesia monitors” such as the bispectral index (BIS) monitor. Historically, bispectral analysis is a standard high-order statistical analysis first used by oceanographers as a measure of time series to study nonlinearity in ocean waves [50]. This was further developed in the 1960s by geophysicist seismologists to study complex seismic waveforms [51]. The first EEG-derived monitor, the BIS (Medtronic, Dublin, Ireland) was introduced in 1994 as a monitor of the effects of certain anesthetic/hypnotic agents [52]. To date the complete details of the BIS algorithm have not been published. Scientifically speaking, all that we really know is that the BIS monitor is merely a “black box” headset and the BIS value reflects a “head-related” biosignal that correlates with changes in the biophase effect-site concentrations of certain hypnotic /sedative drugs and thus cannot be considered a “true” reflection of the depth of anesthesia. In other words, the BIS index is a measure of certain drugs’ effect and is not a true reflection of the EEG signal nor an independent measure of brain function [53]. In the early years all attempts of the manufacturer for the Food and Drug Administration (FDA) to license the BIS as an “independent uniform depth of anesthesia” monitor failed. For instance, a BIS value of 57 for 1 MAC halothane is significantly higher than the BIS value of 32 for an equipotent 1 MAC sevoflurane [54], and significantly higher than a BIS value of 33 for an equipotent 1 MAC isoflurane [55]. While ketamine provides adequate anesthesia, ketamine administration was reported to paradoxically increase the BIS from 44 to 59 [56].
What is the bispectral index then? The BIS algorithms were derived from EEG changes with incremental doses of certain hypnotic drug(s); isoflurane or propofol while measuring 3 descriptors in volunteers. The BIS index is the weighted sum of 3 sub-parameters; Relative BetaRatio most influential during light anesthesia, a frequency–domain feature is the EEG spectral power log (P30–47 Hz /P11–20 Hz), SynchFastSlow predominates during surgical levels of hypnosis, a bispectral–domain feature, is the bispectral power wave band log (B0.5–47 Hz /B40–47 Hz) and Burst Suppression that detects very deep anesthesia, a time–domain feature combining two separate algorithms: Burst Suppression Ratio that quantifies the extent of isoelectrical silence, and QUAZI suppression index that detects Burst Suppression superimposed on wandering low baseline voltage [57]. None of these disparate descriptors is particular per se; as each has a specific range of influence where they perform best. The BIS analysis uses a proprietary algorithm that allows the 3 different descriptors to sequentially dominate as the EEG changes its character with increasing anesthetics’ concentrations. It thus transforms the nonlinear stages of the anesthetic drug effect relative contributions on the EEG into an easy-to-use dimensionless number ranging from 100 (fully awake) to zero (isoelectric EEG) [57].
Obviously, in many instances BIS changes do not truly reflect changing anesthetics’ concentrations, as BIS indices would reflect other unrelated EEG events of certain conditions exerting their own EEG effect. Because the BIS is an EEG derived parameter hence anything that would change the EEG would subsequently change the BIS. There is a body of literature of EEG changes of conditions like hypothermia, hypoglycemia, hypovolemia, hypotension, hepatic encephalopathy or physiological sleep with the same conditions consequently changing the BIS to the same extent [58].
In the realm of the ever-changing landscape of neuromuscular blockade monitors, older designs are frequently replaced with new devices that are often promoted as technically superior by the manufacturers. Conventional mechanomyography (MMG) is regarded by the Stockholm revision consensus conference [59] as the gold standard for precise quantification of neuromuscular block, as it quantifies the exact force displacement isometric muscle contraction of a preload-restrained thumb in response to electric stimulation at the ulnar nerve [33]. The main obstacle facing its wide clinical use is that the equipment takes time to set up and requires rigid support of the arm.
Over the years, we have seen numerous stand-alone or modular-integrated neuromuscular monitoring devices that quantify the neuromuscular function based on physiological phenomena other than force measurement. The kinemyographic (KMG) device known as ParaGraph [60] (Vital Signs, Totowa, NJ) is no longer available for routine clinical use as the manufacturer has been acquired by CareFusion in 2014 although the neuromuscular transmission module (E-NMT) in the AS/5TM anaesthesia monitor (GE, Helsinki, Finland) [61] is still available. Both quantify the signal generated from thumb adduction via deformation of a piezoelectric film sensor in response to electric stimulation of the ulnar nerve. E-NMT has an additional electromyographic (EMG) transducer that quantifies the evoked compound action potential generated at the thenar eminence.
Another attractive class of devices are acceleromyographic (AMG) monitors. The first commercially available product, TOF-GUARDTM (Organon Teknika, Oss, Netherlands) [62]. now discontinued, has been replaced by a simpler device known as TOF-WatchTM (MIPM, Mammendorf, Germany) [63]. Both measure the acceleration using a piezoelectric sensor attached to a freely moving thumb (“piezo” from the Greek word meaning pressure). Note that according to Newton’s second law: force = mass x acceleration, acceleration is directly proportional to force when mass is constant, so that instead of measuring the evoked force, thumb acceleration can be measured instead. A major impediment of this type of monitoring is the fact that the piezoelectric sensor may not always be “properly aligned” to the optimal plane of the thumb movement. A comprehensive systematic review of acceleromyography by Claudius and Viby-Mogensen described many of the methodological problems facing the technology based on evidence based data of 43 publications [63].
With the manufacturer official announcement of the discontinuance of all the TOF Watch monitors series effective June 2016, this development gave way to a new wave of neuromuscular monitoring devices, namely a novel generation of so-called Tri-axial acceleromyographs. Nowadays the only commercially available acceleromyographs all belong to the new Tri-axial based generation; namely the Stimpod NMS 450 (Xavant, Silverton, Pretoria, South Africa), the TOFscan (Dräger, Lübeck, Germany) and the new modular neuromuscular transducer NMT (Mindray, Shenzhen, China).
The above successes notwithstanding, many vital challenges remain to be addressed by the anesthesia technology community. One of these challenges includes reducing the time interval needed to troubleshoot a malfunctioning electrocardiogram, capnograph, pulse oximeter or some other patient monitor prior to starting an anesthesia case. Another challenge is in the realm of alarms [2, 4, 64]; who has not been irritated when the source of a monitor alarm is completely unapparent or when an asystole alarm occurs despite both a good arterial blood pressure waveform and a high-quality pulse oximeter tracing being present. Such difficulties divert attention from direct patient monitoring as mental effort is expended to address some technical problem. Problems related to poor software design or careless user interface designs have also led to patient harm [6568].
In view of these concerns, we would like to propose that the journal support initiatives by publishing reports on the evaluation of anesthesia and perioperative equipment [69]. These reports might be made in a manner not dissimilar to information provided by web sites like eopinions.​com as well as in specialized magazines like Consumer Reports (which provides evaluations of products such as household appliances) or in reports provided by a number of Personal Computer magazines (focusing on software and hardware products).
We envision two general forms of report. The first kind of report would be an informal “first impressions” description of newly available equipment. These reports – or user’s opinions -would frequently make observations concerning ergonomics and equipment usability. Extensive and definite evaluation would not be the primary objective. While necessarily subjective, this information would be valuable to individuals seeking to acquire new equipment. Further, individual feedbacks about a newly available equipment will be of major interest to coordinate clinical evaluations based on structured evaluation protocols in a collaborative effort regrouping clinicians familiar with the equipment.
A second, more formal, kind of report would be supported based on the usual scientific publication presentation. This kind of report would be based on rigorous, reproducible testing methods like those methods used by ECRI (ecri.​org) and other testing agencies to produce detailed, formal, laboratory-based assessments. Additionally, these reports would include clinical evaluations based on broadly discussed evaluation protocols including modern statistical methods. Because of the nature of the devices under evaluation, research protocols tend to vary in objectives, in design and in quality. Collaborative efforts based on a single well-structured design is sometimes the key to obtain timely clinical evaluations of a new device.
The combination of rapid feedback and qualitative structured evaluations of new equipment will allow anesthesia community to focus on the device of interest in a timely matter. Immediate feedback has the potential to improve the design of new devices, and collaborative evaluation effort is usually the fastest way to obtain sufficient data to reliably draw conclusions about the clinical and economical value of a new device.
We believe the journal can play an important role in this initiative. With a more interactive, a more collaborative, and a more international approach, such an initiative would help restore the link between clinical research and clinical end-users. Further, by quickly producing high-quality, clinically relevant evaluations, we believe this initiative could have a long-lasting impact on medical device design as well as ultimately on patient safety.

Competing interests

All authors are associate editors of BMC Anesthesiology. The authors declare that they have no other academic or financial conflicts of interest with respect to this manuscript.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
download
DOWNLOAD
print
DRUCKEN
Literatur
1.
Zurück zum Zitat Pedersen T, Nicholson A, Hovhannisyan K, Møller AM, Smith AF, Lewis SR. Pulse oximetry for perioperative monitoring. Cochrane Database Syst Rev. 2014 Mar 17;3:CD002013. Pedersen T, Nicholson A, Hovhannisyan K, Møller AM, Smith AF, Lewis SR. Pulse oximetry for perioperative monitoring. Cochrane Database Syst Rev. 2014 Mar 17;3:CD002013.
2.
Zurück zum Zitat Imhoff M, Kuhls S, Gather U, Fried R. Smart alarms from medical devices in the OR and ICU. Best Pract Res Clin Anaesthesiol. 2009 Mar;23(1):39–50.CrossRefPubMed Imhoff M, Kuhls S, Gather U, Fried R. Smart alarms from medical devices in the OR and ICU. Best Pract Res Clin Anaesthesiol. 2009 Mar;23(1):39–50.CrossRefPubMed
4.
Zurück zum Zitat Johnson KR, Hagadorn JI, Sink DW. Alarm safety and alarm fatigue. Clin Perinatol. 2017 Sep;44(3):713–28.CrossRefPubMed Johnson KR, Hagadorn JI, Sink DW. Alarm safety and alarm fatigue. Clin Perinatol. 2017 Sep;44(3):713–28.CrossRefPubMed
5.
Zurück zum Zitat Tang R, Ranmuthugala G, Cunningham F. Surgical safety checklists: a review. ANZ J Surg. 2014 Mar;84(3):148–54.CrossRefPubMed Tang R, Ranmuthugala G, Cunningham F. Surgical safety checklists: a review. ANZ J Surg. 2014 Mar;84(3):148–54.CrossRefPubMed
6.
Zurück zum Zitat Staender S, Smith A. Enhancing the quality and safety of the perioperative patient. Curr Opin Anaesthesiol. 2017 Dec;30(6):730–5.CrossRefPubMed Staender S, Smith A. Enhancing the quality and safety of the perioperative patient. Curr Opin Anaesthesiol. 2017 Dec;30(6):730–5.CrossRefPubMed
7.
8.
Zurück zum Zitat Bose E, Hoffman L, Hravnak M. Monitoring cardiorespiratory instability: current approaches and implications for nursing practice. Intensive Crit Care Nurs. 2016 Jun;34:73–80.CrossRefPubMedPubMedCentral Bose E, Hoffman L, Hravnak M. Monitoring cardiorespiratory instability: current approaches and implications for nursing practice. Intensive Crit Care Nurs. 2016 Jun;34:73–80.CrossRefPubMedPubMedCentral
9.
10.
Zurück zum Zitat Kroll RR, McKenzie ED, Boyd JG, Sheth P, Howes D, Wood M, et al. Use of wearable devices for post-discharge monitoring of ICU patients: a feasibility study. J Intensive Care. 2017 Nov 21;5:64.CrossRefPubMedPubMedCentral Kroll RR, McKenzie ED, Boyd JG, Sheth P, Howes D, Wood M, et al. Use of wearable devices for post-discharge monitoring of ICU patients: a feasibility study. J Intensive Care. 2017 Nov 21;5:64.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Stark AP, Maciel RC, Sheppard W, Sacks G, Hines OJ. An early warning score predicts risk of death after in-hospital cardiopulmonary arrest in surgical patients. Am Surg. 2015 Oct;81(10):916–21.PubMed Stark AP, Maciel RC, Sheppard W, Sacks G, Hines OJ. An early warning score predicts risk of death after in-hospital cardiopulmonary arrest in surgical patients. Am Surg. 2015 Oct;81(10):916–21.PubMed
12.
13.
Zurück zum Zitat Wright SM. Patient safety in anesthesia: learning from the culture of high-reliability organizations. Crit Care Nurs Clin North Am. 2015 Mar;27(1):1–16.CrossRefPubMed Wright SM. Patient safety in anesthesia: learning from the culture of high-reliability organizations. Crit Care Nurs Clin North Am. 2015 Mar;27(1):1–16.CrossRefPubMed
14.
Zurück zum Zitat Krombach JW, Marks JD, Dubowitz G, Radke OC. Development and implementation of checklists for routine anesthesia care: a proposal for improving patient safety. Anesth Analg. 2015 Oct;121(4):1097–103.CrossRefPubMed Krombach JW, Marks JD, Dubowitz G, Radke OC. Development and implementation of checklists for routine anesthesia care: a proposal for improving patient safety. Anesth Analg. 2015 Oct;121(4):1097–103.CrossRefPubMed
15.
Zurück zum Zitat Apfelbaum JL, Hagberg CA, Caplan RA, Blitt CD, Connis RT, Nickinovich DG, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology. 2013 Feb;118(2):251–70.CrossRefPubMed Apfelbaum JL, Hagberg CA, Caplan RA, Blitt CD, Connis RT, Nickinovich DG, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology. 2013 Feb;118(2):251–70.CrossRefPubMed
16.
Zurück zum Zitat Merchant R, Chartrand D, Dain S, Dobson G, Kurrek MM, Lagacé A, et al. Guidelines to the practice of anesthesia - revised edition 2016. Can J Anaesth. 2016 Jan;63(1):86–112.CrossRefPubMed Merchant R, Chartrand D, Dain S, Dobson G, Kurrek MM, Lagacé A, et al. Guidelines to the practice of anesthesia - revised edition 2016. Can J Anaesth. 2016 Jan;63(1):86–112.CrossRefPubMed
17.
Zurück zum Zitat Hamzaoui O, Monnet X, Teboul JL. Evolving concepts of hemodynamic monitoring for critically ill patients. Indian J Crit Care Med. 2015 Apr;19(4):220–6.CrossRefPubMedPubMedCentral Hamzaoui O, Monnet X, Teboul JL. Evolving concepts of hemodynamic monitoring for critically ill patients. Indian J Crit Care Med. 2015 Apr;19(4):220–6.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Arriaga AF, Bader AM, Wong JM, Lipsitz SR, Berry WR, Ziewacz JE, et al. Simulation-based trial of surgical-crisis checklists. N Engl J Med. 2013 Jan 17;368(3):246–53.CrossRefPubMed Arriaga AF, Bader AM, Wong JM, Lipsitz SR, Berry WR, Ziewacz JE, et al. Simulation-based trial of surgical-crisis checklists. N Engl J Med. 2013 Jan 17;368(3):246–53.CrossRefPubMed
19.
Zurück zum Zitat Low D, Walker I, Heitmiller ES, Kurth D. Implementing checklists in the operating room. Paediatr Anaesth. 2012 Oct;22(10):1025–31.CrossRefPubMed Low D, Walker I, Heitmiller ES, Kurth D. Implementing checklists in the operating room. Paediatr Anaesth. 2012 Oct;22(10):1025–31.CrossRefPubMed
20.
Zurück zum Zitat Rosenfield LK, Chang DS. The error of omission: a simple checklist approach for improving operating room safety. Plast Reconstr Surg. 2009 Jan;123(1):399–402.CrossRefPubMed Rosenfield LK, Chang DS. The error of omission: a simple checklist approach for improving operating room safety. Plast Reconstr Surg. 2009 Jan;123(1):399–402.CrossRefPubMed
21.
Zurück zum Zitat Boat AC, Spaeth JP. Handoff checklists improve the reliability of patient handoffs in the operating room and postanesthesia care unit. Paediatr Anaesth. 2013 Jul;23(7):647–54.CrossRefPubMed Boat AC, Spaeth JP. Handoff checklists improve the reliability of patient handoffs in the operating room and postanesthesia care unit. Paediatr Anaesth. 2013 Jul;23(7):647–54.CrossRefPubMed
22.
Zurück zum Zitat Erestam S, Haglind E, Bock D, Andersson AE, Angenete E. Changes in safety climate and teamwork in the operating room after implementation of a revised WHO checklist: a prospective interventional study. Patient Saf Surg. 2017 Jan 31;11:4.CrossRefPubMedPubMedCentral Erestam S, Haglind E, Bock D, Andersson AE, Angenete E. Changes in safety climate and teamwork in the operating room after implementation of a revised WHO checklist: a prospective interventional study. Patient Saf Surg. 2017 Jan 31;11:4.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Haynes AB, Weiser TG, Berry WR, Lipsitz SR, Breizat AH, Dellinger EP, et al. A surgical safety checklist to reduce morbidity and mortality in a global population. N Engl J Med. 2009 Jan 29;360(5):491–9.CrossRefPubMed Haynes AB, Weiser TG, Berry WR, Lipsitz SR, Breizat AH, Dellinger EP, et al. A surgical safety checklist to reduce morbidity and mortality in a global population. N Engl J Med. 2009 Jan 29;360(5):491–9.CrossRefPubMed
24.
Zurück zum Zitat McGill J. Airway management in trauma: an update. Emerg Med Clin North Am. 2007;25(3):603–22. viiCrossRefPubMed McGill J. Airway management in trauma: an update. Emerg Med Clin North Am. 2007;25(3):603–22. viiCrossRefPubMed
25.
Zurück zum Zitat Frova G, Sorbello M. Algorithms for difficult airway management: a review. Minerva Anestesiol. 2009 Apr;75(4):201–9.PubMed Frova G, Sorbello M. Algorithms for difficult airway management: a review. Minerva Anestesiol. 2009 Apr;75(4):201–9.PubMed
27.
Zurück zum Zitat Bjoernsen LP, Lindsay B. Video laryngoscopy in the prehospital setting. Prehosp Disaster Med. 2009 Jun;24(3):265–70.CrossRefPubMed Bjoernsen LP, Lindsay B. Video laryngoscopy in the prehospital setting. Prehosp Disaster Med. 2009 Jun;24(3):265–70.CrossRefPubMed
28.
Zurück zum Zitat Aziz MF, Kim D, Mako J, Hand K, Brambrink AM. A retrospective study of the performance of video laryngoscopy in an obstetric unit. Anesth Analg. 2012 Oct;115(4):904–6.CrossRefPubMed Aziz MF, Kim D, Mako J, Hand K, Brambrink AM. A retrospective study of the performance of video laryngoscopy in an obstetric unit. Anesth Analg. 2012 Oct;115(4):904–6.CrossRefPubMed
29.
30.
Zurück zum Zitat Russo SG, Weiss M, Eich C. Video laryngoscopy olé! Time to say good bye to direct and flexible intubation? Anaesthesist. 2012 Dec;61(12):1017–26.CrossRefPubMed Russo SG, Weiss M, Eich C. Video laryngoscopy olé! Time to say good bye to direct and flexible intubation? Anaesthesist. 2012 Dec;61(12):1017–26.CrossRefPubMed
31.
Zurück zum Zitat Xue FS, Liu GP, Sun C, Li RP. Comparing emergency intubation with direct and video laryngoscopy. Acad Emerg Med. 2016 May 14;23(6):747–8.CrossRefPubMed Xue FS, Liu GP, Sun C, Li RP. Comparing emergency intubation with direct and video laryngoscopy. Acad Emerg Med. 2016 May 14;23(6):747–8.CrossRefPubMed
32.
Zurück zum Zitat Mort TC. Continuous airway access for the difficult extubation: the efficacy of the airway exchange catheter. Anesth Analg. 2007;105(5):1357–62. table of contentsCrossRefPubMed Mort TC. Continuous airway access for the difficult extubation: the efficacy of the airway exchange catheter. Anesth Analg. 2007;105(5):1357–62. table of contentsCrossRefPubMed
33.
Zurück zum Zitat Cooper RM. The use of an endotracheal ventilation catheter in the management of difficult extubations. Can J Anaesth. 1996 Jan;43(1):90–3.CrossRefPubMed Cooper RM. The use of an endotracheal ventilation catheter in the management of difficult extubations. Can J Anaesth. 1996 Jan;43(1):90–3.CrossRefPubMed
34.
Zurück zum Zitat Moyers G, McDougle L. Use of the cook airway exchange catheter in “bridging” the potentially difficult extubation: a case report. AANA J. 2002 Aug;70(4):275–8.PubMed Moyers G, McDougle L. Use of the cook airway exchange catheter in “bridging” the potentially difficult extubation: a case report. AANA J. 2002 Aug;70(4):275–8.PubMed
36.
Zurück zum Zitat Hernandez MC, Aho JM, Zielinski MD, Zietlow SP, Kim BD, Morris DS. Definitive airway management after pre-hospital supraglottic airway insertion: outcomes and a management algorithm for trauma patients. Am J Emerg Med. 2018 Jan;36(1):114–9.CrossRefPubMed Hernandez MC, Aho JM, Zielinski MD, Zietlow SP, Kim BD, Morris DS. Definitive airway management after pre-hospital supraglottic airway insertion: outcomes and a management algorithm for trauma patients. Am J Emerg Med. 2018 Jan;36(1):114–9.CrossRefPubMed
37.
Zurück zum Zitat Huang AS, Hajduk J, Jagannathan N. Advances in supraglottic airway devices for the management of difficult airways in children. Expert Rev Med Devices. 2016 Jan 29;13(2):157–69.CrossRefPubMed Huang AS, Hajduk J, Jagannathan N. Advances in supraglottic airway devices for the management of difficult airways in children. Expert Rev Med Devices. 2016 Jan 29;13(2):157–69.CrossRefPubMed
38.
Zurück zum Zitat Vithalani VD, Vlk S, Davis SQ, Richmond NJ. Unrecognized failed airway management using a supraglottic airway device. Resuscitation. 2017 Oct;119:1–4.CrossRefPubMed Vithalani VD, Vlk S, Davis SQ, Richmond NJ. Unrecognized failed airway management using a supraglottic airway device. Resuscitation. 2017 Oct;119:1–4.CrossRefPubMed
39.
Zurück zum Zitat Katsnelson Y, Raman J, Katsnelson F, Mor-Avi V, Heller LB, Jayakar D, et al. Current state of intraoperative echocardiography. Echocardiography. 2003 Nov;20(8):771–80.CrossRefPubMed Katsnelson Y, Raman J, Katsnelson F, Mor-Avi V, Heller LB, Jayakar D, et al. Current state of intraoperative echocardiography. Echocardiography. 2003 Nov;20(8):771–80.CrossRefPubMed
40.
Zurück zum Zitat Pislaru SV, Michelena HI, Mankad SV. Interventional echocardiography. Prog Cardiovasc Dis. 2014 Aug;57(1):32–46.CrossRefPubMed Pislaru SV, Michelena HI, Mankad SV. Interventional echocardiography. Prog Cardiovasc Dis. 2014 Aug;57(1):32–46.CrossRefPubMed
41.
Zurück zum Zitat Stock KF, Klein B, Steubl D, Lersch C, Heemann U, Wagenpfeil S, et al. Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination. Abdom Imaging. 2015 Oct;40(7):2861–6.CrossRefPubMed Stock KF, Klein B, Steubl D, Lersch C, Heemann U, Wagenpfeil S, et al. Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination. Abdom Imaging. 2015 Oct;40(7):2861–6.CrossRefPubMed
42.
Zurück zum Zitat Kobal SL, Trento L, Baharami S, Tolstrup K, Naqvi TZ, Cercek B, et al. Comparison of effectiveness of hand-carried ultrasound to bedside cardiovascular physical examination. Am J Cardiol. 2005 Oct 1;96(7):1002–6.CrossRefPubMed Kobal SL, Trento L, Baharami S, Tolstrup K, Naqvi TZ, Cercek B, et al. Comparison of effectiveness of hand-carried ultrasound to bedside cardiovascular physical examination. Am J Cardiol. 2005 Oct 1;96(7):1002–6.CrossRefPubMed
43.
Zurück zum Zitat Galusko V, Khanji MY, Bodger O, Weston C, Chambers J, Ionescu A. Hand-held ultrasound scanners in medical education: a systematic review. J Cardiovasc Ultrasound. 2017 Sep 29;25(3):75–83.CrossRefPubMedPubMedCentral Galusko V, Khanji MY, Bodger O, Weston C, Chambers J, Ionescu A. Hand-held ultrasound scanners in medical education: a systematic review. J Cardiovasc Ultrasound. 2017 Sep 29;25(3):75–83.CrossRefPubMedPubMedCentral
44.
Zurück zum Zitat Kimura BJ, Shaw DJ, Amundson SA, Phan JN, Blanchard DG, DeMaria AN. Cardiac limited ultrasound examination techniques to augment the bedside cardiac physical examination. J Ultrasound Med. 2015 Sep;34(9):1683–90.CrossRefPubMed Kimura BJ, Shaw DJ, Amundson SA, Phan JN, Blanchard DG, DeMaria AN. Cardiac limited ultrasound examination techniques to augment the bedside cardiac physical examination. J Ultrasound Med. 2015 Sep;34(9):1683–90.CrossRefPubMed
45.
Zurück zum Zitat Smith ME, Chiovaro JC, O’Neil M, Kansagara D, Quiñones AR, Freeman M, et al. Early warning system scores for clinical deterioration in hospitalized patients: a systematic review. Ann Am Thorac Soc. 2014 Nov;11(9):1454–65.CrossRefPubMed Smith ME, Chiovaro JC, O’Neil M, Kansagara D, Quiñones AR, Freeman M, et al. Early warning system scores for clinical deterioration in hospitalized patients: a systematic review. Ann Am Thorac Soc. 2014 Nov;11(9):1454–65.CrossRefPubMed
46.
Zurück zum Zitat Friedman AM. Maternal early warning systems. Obstet Gynecol Clin N Am. 2015 Jun;42(2):289–98.CrossRef Friedman AM. Maternal early warning systems. Obstet Gynecol Clin N Am. 2015 Jun;42(2):289–98.CrossRef
47.
Zurück zum Zitat Paliwoda M, New K, Bogossian F. Neonatal early warning tools for recognising and responding to clinical deterioration in neonates cared for in the maternity setting: a retrospective case-control study. Int J Nurs Stud. 2016 Sep;61:125–35.CrossRefPubMed Paliwoda M, New K, Bogossian F. Neonatal early warning tools for recognising and responding to clinical deterioration in neonates cared for in the maternity setting: a retrospective case-control study. Int J Nurs Stud. 2016 Sep;61:125–35.CrossRefPubMed
48.
Zurück zum Zitat Parfitt SE, Bogat ML, Hering SL, Ottley C, Roth C. Sepsis in obstetrics: clinical features and early warning tools. MCN Am J Matern Child Nurs. 2017;42(4):199–205.CrossRefPubMed Parfitt SE, Bogat ML, Hering SL, Ottley C, Roth C. Sepsis in obstetrics: clinical features and early warning tools. MCN Am J Matern Child Nurs. 2017;42(4):199–205.CrossRefPubMed
49.
Zurück zum Zitat Miranda JOF, Camargo CL, Nascimento CL, Portela DS, Monaghan A. Accuracy of a pediatric early warning score in the recognition of clinical deterioration. Rev Lat Am Enfermagem. 2017 Jul 10;25:e2912.CrossRefPubMedPubMedCentral Miranda JOF, Camargo CL, Nascimento CL, Portela DS, Monaghan A. Accuracy of a pediatric early warning score in the recognition of clinical deterioration. Rev Lat Am Enfermagem. 2017 Jul 10;25:e2912.CrossRefPubMedPubMedCentral
50.
Zurück zum Zitat Hasselmann K, Munk W, MacDonald G. Bispectra of ocean waves. In: Rosenblatt M, editor. Time series analysis; 1963. p. 125–39. Hasselmann K, Munk W, MacDonald G. Bispectra of ocean waves. In: Rosenblatt M, editor. Time series analysis; 1963. p. 125–39.
51.
Zurück zum Zitat Haubrich RA. Earth noise 5 to 500 millicycles per second. J Geophys Res. 1965;70:1415–27.CrossRef Haubrich RA. Earth noise 5 to 500 millicycles per second. J Geophys Res. 1965;70:1415–27.CrossRef
52.
Zurück zum Zitat Sigl JC, Chamoun NG. An introduction to bispectral analysis for the electroencephalogram. J Clin Monit. 1994 Nov;10(6):392–404.CrossRefPubMed Sigl JC, Chamoun NG. An introduction to bispectral analysis for the electroencephalogram. J Clin Monit. 1994 Nov;10(6):392–404.CrossRefPubMed
53.
Zurück zum Zitat Vuyk J, Lichtenbelt BJ, Vieveen J, Dahan A, Engbers FH, Burm AG. Low bispectral index values in awake volunteers receiving a combination of propofol and midazolam. Anesthesiology. 2004 Jan 1;100(1):179–81.CrossRefPubMed Vuyk J, Lichtenbelt BJ, Vieveen J, Dahan A, Engbers FH, Burm AG. Low bispectral index values in awake volunteers receiving a combination of propofol and midazolam. Anesthesiology. 2004 Jan 1;100(1):179–81.CrossRefPubMed
54.
Zurück zum Zitat Edwards JJ, Soto RG, Thrush DM, Bedford RF. Bispectral index scale is higher for halothane than sevoflurane during intraoperative anesthesia. Anesthesiology. 2003 Dec;99(6):1453–5.CrossRefPubMed Edwards JJ, Soto RG, Thrush DM, Bedford RF. Bispectral index scale is higher for halothane than sevoflurane during intraoperative anesthesia. Anesthesiology. 2003 Dec;99(6):1453–5.CrossRefPubMed
55.
Zurück zum Zitat Davidson AJ, Czarnecki C. The Bispectral index in children: comparing isoflurane and halothane. Br J Anaesth. 2004 Jan;92(1):14–7.CrossRefPubMed Davidson AJ, Czarnecki C. The Bispectral index in children: comparing isoflurane and halothane. Br J Anaesth. 2004 Jan;92(1):14–7.CrossRefPubMed
56.
Zurück zum Zitat Vereecke HE, Struys MM, Mortier EPA. Comparison of bispectral index and ARX-derived auditory evoked potential index in measuring the clinical interaction between ketamine and propofol anaesthesia. Anaesthesia. 2003 Oct;58(10):957–61.CrossRefPubMed Vereecke HE, Struys MM, Mortier EPA. Comparison of bispectral index and ARX-derived auditory evoked potential index in measuring the clinical interaction between ketamine and propofol anaesthesia. Anaesthesia. 2003 Oct;58(10):957–61.CrossRefPubMed
57.
Zurück zum Zitat Rampil IJA. Primer for EEG signal processing in anesthesia. Anesthesiology. 1998 Oct;89(4):980–1002.CrossRefPubMed Rampil IJA. Primer for EEG signal processing in anesthesia. Anesthesiology. 1998 Oct;89(4):980–1002.CrossRefPubMed
58.
Zurück zum Zitat Dahaba AA. Different conditions that could result in the bispectral index indicating an incorrect hypnotic state. Anesth Analg. 2005 Sep;101(3):765–73.CrossRefPubMed Dahaba AA. Different conditions that could result in the bispectral index indicating an incorrect hypnotic state. Anesth Analg. 2005 Sep;101(3):765–73.CrossRefPubMed
59.
Zurück zum Zitat Fuchs-Buder T, Claudius C, Skovgaard LT, Eriksson LI, Mirakhur RK, Viby-Mogensen J, et al. Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents II: the Stockholm revision. Acta Anaesthesiol Scand. 2007 Aug;51(7):789–808.CrossRefPubMed Fuchs-Buder T, Claudius C, Skovgaard LT, Eriksson LI, Mirakhur RK, Viby-Mogensen J, et al. Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents II: the Stockholm revision. Acta Anaesthesiol Scand. 2007 Aug;51(7):789–808.CrossRefPubMed
60.
Zurück zum Zitat Dahaba AA, Von Klobucar F, Rehak PH, List WF. Comparison of a new piezoelectric train-of-four neuromuscular monitor, the ParaGraph, and the Relaxometer mechanomyograph. Br J Anaesth. 1999 May;82(5):780–2.CrossRefPubMed Dahaba AA, Von Klobucar F, Rehak PH, List WF. Comparison of a new piezoelectric train-of-four neuromuscular monitor, the ParaGraph, and the Relaxometer mechanomyograph. Br J Anaesth. 1999 May;82(5):780–2.CrossRefPubMed
61.
Zurück zum Zitat Dahaba AA, von Klobucar F, Rehak PH, List WF. The neuromuscular transmission module versus the relaxometer mechanomyograph for neuromuscular block monitoring. Anesth Analg. 2002;94(3):591–6. table of contentsCrossRefPubMed Dahaba AA, von Klobucar F, Rehak PH, List WF. The neuromuscular transmission module versus the relaxometer mechanomyograph for neuromuscular block monitoring. Anesth Analg. 2002;94(3):591–6. table of contentsCrossRefPubMed
62.
Zurück zum Zitat Loan PB, Paxton LD, Mirakhur RK, Connolly FM, McCoy EP. The TOF-guard neuromuscular transmission monitor. A comparison with the Myograph 2000. Anaesthesia. 1995 Aug;50(8):699–702.CrossRefPubMed Loan PB, Paxton LD, Mirakhur RK, Connolly FM, McCoy EP. The TOF-guard neuromuscular transmission monitor. A comparison with the Myograph 2000. Anaesthesia. 1995 Aug;50(8):699–702.CrossRefPubMed
63.
Zurück zum Zitat Claudius C, Viby-Mogensen J. Acceleromyography for use in scientific and clinical practice: a systematic review of the evidence. Anesthesiology. 2008 Jun;108(6):1117–40.CrossRefPubMed Claudius C, Viby-Mogensen J. Acceleromyography for use in scientific and clinical practice: a systematic review of the evidence. Anesthesiology. 2008 Jun;108(6):1117–40.CrossRefPubMed
64.
Zurück zum Zitat Cosper P, Zellinger M, Enebo A, Jacques S, Razzano L, Flack MN. Improving clinical alarm management: guidance and strategies. Biomed Instrum Technol. 2017 Apr;51(2):109–15.CrossRefPubMed Cosper P, Zellinger M, Enebo A, Jacques S, Razzano L, Flack MN. Improving clinical alarm management: guidance and strategies. Biomed Instrum Technol. 2017 Apr;51(2):109–15.CrossRefPubMed
65.
Zurück zum Zitat Ronquillo JG, Zuckerman DM. Software-related recalls of health information technology and other medical devices: implications for FDA regulation of digital health. Milbank Q. 2017;95(3):535–53.CrossRefPubMedPubMedCentral Ronquillo JG, Zuckerman DM. Software-related recalls of health information technology and other medical devices: implications for FDA regulation of digital health. Milbank Q. 2017;95(3):535–53.CrossRefPubMedPubMedCentral
66.
Zurück zum Zitat Ergonomics DD. Patient safety, and engineering ethics: a case study and cautionary tale. J Long-Term Eff Med Implants. 2007;17(1):27–33.CrossRef Ergonomics DD. Patient safety, and engineering ethics: a case study and cautionary tale. J Long-Term Eff Med Implants. 2007;17(1):27–33.CrossRef
67.
Zurück zum Zitat Bennett KB. Ecological interface design and system safety: one facet of Rasmussen’s legacy. Appl Ergon. 2017 Mar;59(Pt B):625–36.CrossRefPubMed Bennett KB. Ecological interface design and system safety: one facet of Rasmussen’s legacy. Appl Ergon. 2017 Mar;59(Pt B):625–36.CrossRefPubMed
68.
Zurück zum Zitat Israelski EW, Muto WH. Human factors risk management as a way to improve medical device safety: a case study of the Therac 25 radiation therapy system. Jt Comm J Qual Saf. 2004 Dec;30(12):689–95.CrossRefPubMed Israelski EW, Muto WH. Human factors risk management as a way to improve medical device safety: a case study of the Therac 25 radiation therapy system. Jt Comm J Qual Saf. 2004 Dec;30(12):689–95.CrossRefPubMed
69.
Zurück zum Zitat Doyle DJ. Consumer reports for anesthesia equipment: an idea whose time has come? Anesth Analg. 2007;105(6):1866–7. author reply 1867CrossRefPubMed Doyle DJ. Consumer reports for anesthesia equipment: an idea whose time has come? Anesth Analg. 2007;105(6):1866–7. author reply 1867CrossRefPubMed
Metadaten
Titel
Advances in anesthesia technology are improving patient care, but many challenges remain
verfasst von
D. John Doyle
Ashraf A. Dahaba
Yannick LeManach
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
BMC Anesthesiology / Ausgabe 1/2018
Elektronische ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-018-0504-x

Weitere Artikel der Ausgabe 1/2018

BMC Anesthesiology 1/2018 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.