Allergy to Surgical Implants

verfasst von: Karin A. Pacheco

Erschienen in: Clinical Reviews in Allergy & Immunology | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

Surgical implants are essential elements of repair procedures to correct worn out joints, damaged spinal components, heart and vascular disease, and chronic pain. However, many of the materials that provide stability, flexibility, and durability to the implants are also immunogenic. Fortunately, allergic responses to surgical implants are infrequent. When they do occur, however, the associated pain, swelling, inflammation, and decreased range of motion can significantly impair the implant function. Given the high numbers of joint replacements performed in the developed world, allergic reactions to orthopedic implants form the largest category of allergic responses. The most important allergens in this category include nickel, cobalt, chromium, and bone cement. These allergens are also the most important in reactions to spinal surgeries. Multiple cardiac and neurostimulatory devices are constructed of metals and adhesives that can be sensitizing in some individuals. Implantable pulse generators, important in cardiac pacemakers, gastric stimulators, and neurostimulators, may include components made of stainless steel, titanium alloy, platinum and iridium, epoxy resins, poly methyl methacrylates, and isocyanates, all of which are immunogenic in some patients. Cardiac stents and patches are often made of Nitinol, a composite of nickel and titanium. More surgical procedures are closed using skin glues, which are also capable of triggering a blistering contact dermatitis. Patch testing is the gold standard to determine sensitization, and this review provides a list of standard allergens to test for different implants. The patients most appropriate for testing include (1) pre-operative joint replacement patients with a prior history of skin reactions to metal jewelry, jean snaps, watch bands, metal glass frames, artificial nails, or skin glue; (2) post-operative joint replacement failure patients needing revision without an obvious cause such as infection or mechanical incompatibility; and (3) post-operative cardiac or neurological patients with localized rash, pain, swelling, or inflammation near or over the implant.
Literatur
1.
Zurück zum Zitat Cram P, Lu X, Kaboli PJ et al (2011) Clinical characteristics and outcomes of Medicare patients undergoing total hip arthroplasty, 1991–2008. JAMA 305:1560–1567CrossRefPubMedPubMedCentral Cram P, Lu X, Kaboli PJ et al (2011) Clinical characteristics and outcomes of Medicare patients undergoing total hip arthroplasty, 1991–2008. JAMA 305:1560–1567CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Cram P, Lu X, Kates SL, Singh JA, Li Y, Wolf BR (2012) Total knee arthroplasty volume, utilization, and outcomes among Medicare beneficiaries, 1991–2010. JAMA 308:1227–1236CrossRefPubMedPubMedCentral Cram P, Lu X, Kates SL, Singh JA, Li Y, Wolf BR (2012) Total knee arthroplasty volume, utilization, and outcomes among Medicare beneficiaries, 1991–2010. JAMA 308:1227–1236CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Maradit Kremers H, Larson DR, Crowson CS et al (2015) Prevalence of total hip and knee replacement in the United States. J Bone Joint Surg Am 97:1386–1397CrossRefPubMed Maradit Kremers H, Larson DR, Crowson CS et al (2015) Prevalence of total hip and knee replacement in the United States. J Bone Joint Surg Am 97:1386–1397CrossRefPubMed
5.
Zurück zum Zitat Hawker GA, Badley EM, Croxford R et al (2009) A population-based nested case-control study of the costs of hip and knee replacement surgery. Med Care 47:732–741CrossRefPubMed Hawker GA, Badley EM, Croxford R et al (2009) A population-based nested case-control study of the costs of hip and knee replacement surgery. Med Care 47:732–741CrossRefPubMed
6.
Zurück zum Zitat Rasanen P, Paavolainen P, Sintonen H et al (2007) Effectiveness of hip or knee replacement surgery in terms of quality-adjusted life years and costs. Acta Orthop 78:108–115CrossRefPubMed Rasanen P, Paavolainen P, Sintonen H et al (2007) Effectiveness of hip or knee replacement surgery in terms of quality-adjusted life years and costs. Acta Orthop 78:108–115CrossRefPubMed
7.
Zurück zum Zitat Daigle ME, Weinstein AM, Katz JN, Losina E (2012) The cost-effectiveness of total joint arthroplasty: a systematic review of published literature. Best Pract Res Clin Rheumatol 26:649–658CrossRefPubMed Daigle ME, Weinstein AM, Katz JN, Losina E (2012) The cost-effectiveness of total joint arthroplasty: a systematic review of published literature. Best Pract Res Clin Rheumatol 26:649–658CrossRefPubMed
8.
Zurück zum Zitat Nwachukwu BU, Bozic KJ, Schairer WW et al (2015) Current status of cost utility analyses in total joint arthroplasty: a systematic review. Clin Orthop Relat Res 473:1815–1827CrossRefPubMed Nwachukwu BU, Bozic KJ, Schairer WW et al (2015) Current status of cost utility analyses in total joint arthroplasty: a systematic review. Clin Orthop Relat Res 473:1815–1827CrossRefPubMed
10.
Zurück zum Zitat Ong KL, Mowat FS, Chan N, Lau E, Halpern MT, Kurtz SM (2006) Economic burden of revision hip and knee arthroplasty in Medicare enrollees. Clin Orthop Relat Res 446:22–28CrossRefPubMed Ong KL, Mowat FS, Chan N, Lau E, Halpern MT, Kurtz SM (2006) Economic burden of revision hip and knee arthroplasty in Medicare enrollees. Clin Orthop Relat Res 446:22–28CrossRefPubMed
11.
Zurück zum Zitat Labek G, Thaler M, Janda W, Agreiter M, Stockl B (2011) Revision rates after total joint replacement: cumulative results from worldwide joint register datasets. J Bone Joint Surg (Br) 93:293–297CrossRef Labek G, Thaler M, Janda W, Agreiter M, Stockl B (2011) Revision rates after total joint replacement: cumulative results from worldwide joint register datasets. J Bone Joint Surg (Br) 93:293–297CrossRef
12.
Zurück zum Zitat Labek G, Todorov S, Iovanescu L, Stoica CI, Bohler N (2013) Outcome after total ankle arthroplasty-results and findings from worldwide arthroplasty registers. Int Orthop 37:1677–1682CrossRefPubMedPubMedCentral Labek G, Todorov S, Iovanescu L, Stoica CI, Bohler N (2013) Outcome after total ankle arthroplasty-results and findings from worldwide arthroplasty registers. Int Orthop 37:1677–1682CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Dummit LA, Kahvecioglu D, Marrufo G et al (2016) Association between hospital participation in a Medicare bundled payment initiative and payments and quality outcomes for lower extremity joint replacement episodes. JAMA 316:1267–1278CrossRefPubMed Dummit LA, Kahvecioglu D, Marrufo G et al (2016) Association between hospital participation in a Medicare bundled payment initiative and payments and quality outcomes for lower extremity joint replacement episodes. JAMA 316:1267–1278CrossRefPubMed
14.
Zurück zum Zitat Sharkey PF, Lichstein PM, Shen C, Tokarski AT, Parvizi J (2014) Why are total knee arthroplasties failing today—has anything changed after 10 years? J Arthroplast 29:1774–1778CrossRef Sharkey PF, Lichstein PM, Shen C, Tokarski AT, Parvizi J (2014) Why are total knee arthroplasties failing today—has anything changed after 10 years? J Arthroplast 29:1774–1778CrossRef
15.
Zurück zum Zitat Jafari SM, Coyle C, Mortazavi SM, Sharkey PF, Parvizi J (2010) Revision hip arthroplasty: infection is the most common cause of failure. Clin Orthop Relat Res 468:2046–2051CrossRefPubMedPubMedCentral Jafari SM, Coyle C, Mortazavi SM, Sharkey PF, Parvizi J (2010) Revision hip arthroplasty: infection is the most common cause of failure. Clin Orthop Relat Res 468:2046–2051CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Delaunay C, Hamadouche M, Girard J, Duhamel A (2013) So FG. What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471:3863–3869CrossRefPubMedPubMedCentral Delaunay C, Hamadouche M, Girard J, Duhamel A (2013) So FG. What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471:3863–3869CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Evans EM, Freeman MA, Miller AJ, Vernon-Roberts B (1974) Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement. J Bone Joint Surg (Br) 56-B:626–642CrossRef Evans EM, Freeman MA, Miller AJ, Vernon-Roberts B (1974) Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement. J Bone Joint Surg (Br) 56-B:626–642CrossRef
18.
19.
Zurück zum Zitat Thienpont E, Berger Y (2013) No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature. Knee Surg Sports Traumatol Arthrosc 21:636–640CrossRefPubMed Thienpont E, Berger Y (2013) No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature. Knee Surg Sports Traumatol Arthrosc 21:636–640CrossRefPubMed
20.
Zurück zum Zitat Granchi D, Cenni E, Trisolino G, Giunti A, Baldini N (2005) Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater 77:257–264 Granchi D, Cenni E, Trisolino G, Giunti A, Baldini N (2005) Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater 77:257–264
21.
Zurück zum Zitat Krecisz B, Kiec-Swierczynska M, Chomiczewska-Skora D (2012) Allergy to orthopedic metal implants—a prospective study. Int J Occup Med Environ Health 25:463–469PubMed Krecisz B, Kiec-Swierczynska M, Chomiczewska-Skora D (2012) Allergy to orthopedic metal implants—a prospective study. Int J Occup Med Environ Health 25:463–469PubMed
22.
Zurück zum Zitat Eben R, Dietrich KA, Nerz C et al (2010) Contact allergy to metals and bone cement components in patients with intolerance of arthroplasty. Dtsch Med Wochenschr 135:1418–1422CrossRefPubMed Eben R, Dietrich KA, Nerz C et al (2010) Contact allergy to metals and bone cement components in patients with intolerance of arthroplasty. Dtsch Med Wochenschr 135:1418–1422CrossRefPubMed
23.
Zurück zum Zitat Atanaskova Mesinkovska N, Tellez A, Molina L et al (2012) The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants. Arch Dermatol 148:687–693CrossRefPubMed Atanaskova Mesinkovska N, Tellez A, Molina L et al (2012) The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants. Arch Dermatol 148:687–693CrossRefPubMed
24.
Zurück zum Zitat Thomas P, Braathen LR, Dorig M et al (2009) Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy 64:1157–1165CrossRefPubMed Thomas P, Braathen LR, Dorig M et al (2009) Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy 64:1157–1165CrossRefPubMed
25.
Zurück zum Zitat Treudler R, Simon JC (2007) Benzoyl peroxide: is it a relevant bone cement allergen in patients with orthopaedic implants? Contact Dermatitis 57:177–180CrossRefPubMed Treudler R, Simon JC (2007) Benzoyl peroxide: is it a relevant bone cement allergen in patients with orthopaedic implants? Contact Dermatitis 57:177–180CrossRefPubMed
26.
Zurück zum Zitat Edwards SA, Gardiner J (2007) Hypersensitivity to benzoyl peroxide in a cemented total knee arthroplasty: cement allergy. J Arthroplast 22:1226–1228CrossRef Edwards SA, Gardiner J (2007) Hypersensitivity to benzoyl peroxide in a cemented total knee arthroplasty: cement allergy. J Arthroplast 22:1226–1228CrossRef
27.
Zurück zum Zitat Bircher A, Friederich NF, Seelig W, Scherer K (2012) Allergic complications from orthopaedic joint implants: the role of delayed hypersensitivity to benzoyl peroxide in bone cement. Contact Dermatitis 66:20–26CrossRefPubMed Bircher A, Friederich NF, Seelig W, Scherer K (2012) Allergic complications from orthopaedic joint implants: the role of delayed hypersensitivity to benzoyl peroxide in bone cement. Contact Dermatitis 66:20–26CrossRefPubMed
28.
Zurück zum Zitat Haddad FS, Cobb AG, Bentley G, Levell NJ, Dowd PM (1996) Hypersensitivity in aseptic loosening of total hip replacements. The role of constituents of bone cement. J Bone Joint Surg (Br) 78:546–549CrossRef Haddad FS, Cobb AG, Bentley G, Levell NJ, Dowd PM (1996) Hypersensitivity in aseptic loosening of total hip replacements. The role of constituents of bone cement. J Bone Joint Surg (Br) 78:546–549CrossRef
29.
Zurück zum Zitat Erpenbach J, Hofmeister E (2008) Hypersensitivity to polymethylmethacrylate following shoulder hemiarthroplasty. Orthopedics 31:708CrossRefPubMed Erpenbach J, Hofmeister E (2008) Hypersensitivity to polymethylmethacrylate following shoulder hemiarthroplasty. Orthopedics 31:708CrossRefPubMed
30.
Zurück zum Zitat Anand A, McGlynn F, Jiranek W (2009) Metal hypersensitivity: can it mimic infection? J Arthroplast 24:826 e825–826 e828CrossRef Anand A, McGlynn F, Jiranek W (2009) Metal hypersensitivity: can it mimic infection? J Arthroplast 24:826 e825–826 e828CrossRef
31.
Zurück zum Zitat Willert HG, Buchhorn GH, Fayyazi A et al (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87:28–36CrossRefPubMed Willert HG, Buchhorn GH, Fayyazi A et al (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87:28–36CrossRefPubMed
32.
Zurück zum Zitat Thomas P, von der Helm C, Schopf C et al (2015) Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern. Biomed Res Int 2015:910156PubMedPubMedCentral Thomas P, von der Helm C, Schopf C et al (2015) Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern. Biomed Res Int 2015:910156PubMedPubMedCentral
33.
Zurück zum Zitat Mahendra G, Pandit H, Kliskey K, Murray D, Gill HS, Athanasou N (2009) Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. Acta Orthop 80:653–659CrossRefPubMedPubMedCentral Mahendra G, Pandit H, Kliskey K, Murray D, Gill HS, Athanasou N (2009) Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. Acta Orthop 80:653–659CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Koster R, Vieluf D, Kiehn M et al (2000) Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 356:1895–1897CrossRefPubMed Koster R, Vieluf D, Kiehn M et al (2000) Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 356:1895–1897CrossRefPubMed
35.
Zurück zum Zitat Saito T, Hokimoto S, Oshima S, Noda K, Kojyo Y, Matsunaga K (2009) Metal allergic reaction in chronic refractory in-stent restenosis. Cardiovasc Revasc Med 10:17–22CrossRefPubMed Saito T, Hokimoto S, Oshima S, Noda K, Kojyo Y, Matsunaga K (2009) Metal allergic reaction in chronic refractory in-stent restenosis. Cardiovasc Revasc Med 10:17–22CrossRefPubMed
36.
Zurück zum Zitat Banerji A, Lax T, Guyer A, Hurwitz S, Camargo CA Jr, Long AA (2014) Management of hypersensitivity reactions to Carboplatin and Paclitaxel in an outpatient oncology infusion center: a 5-year review. J Allergy Clin Immunol Pract 2:428–433CrossRefPubMed Banerji A, Lax T, Guyer A, Hurwitz S, Camargo CA Jr, Long AA (2014) Management of hypersensitivity reactions to Carboplatin and Paclitaxel in an outpatient oncology infusion center: a 5-year review. J Allergy Clin Immunol Pract 2:428–433CrossRefPubMed
37.
Zurück zum Zitat Pfoch L, Mahler V, Sticherling M (2009) Drug-eluting coronary stents: hypersensitivity reactions to paclitaxel. A case report. Dermatology 218:52–55CrossRefPubMed Pfoch L, Mahler V, Sticherling M (2009) Drug-eluting coronary stents: hypersensitivity reactions to paclitaxel. A case report. Dermatology 218:52–55CrossRefPubMed
38.
Zurück zum Zitat Nakazawa G (2011) Stent thrombosis of drug eluting stent: pathological perspective. J Cardiol 58:84–91CrossRefPubMed Nakazawa G (2011) Stent thrombosis of drug eluting stent: pathological perspective. J Cardiol 58:84–91CrossRefPubMed
39.
Zurück zum Zitat Svedman C, Moller H, Gruvberger B et al (2014) Implants and contact allergy: are sensitizing metals released as haptens from coronary stents? Contact Dermatitis 71:92–97CrossRefPubMed Svedman C, Moller H, Gruvberger B et al (2014) Implants and contact allergy: are sensitizing metals released as haptens from coronary stents? Contact Dermatitis 71:92–97CrossRefPubMed
40.
Zurück zum Zitat Halwani DO, Anderson PG, Lemons JE, Jordan WD, Anayiotos AS, Brott BC (2010) In-vivo corrosion and local release of metallic ions from vascular stents into surrounding tissue. J Invasive Cardiol 22:528–535PubMed Halwani DO, Anderson PG, Lemons JE, Jordan WD, Anayiotos AS, Brott BC (2010) In-vivo corrosion and local release of metallic ions from vascular stents into surrounding tissue. J Invasive Cardiol 22:528–535PubMed
41.
Zurück zum Zitat Svedman C, Ekqvist S, Moller H et al (2009) A correlation found between contact allergy to stent material and restenosis of the coronary arteries. Contact Dermatitis 60:158–164CrossRefPubMed Svedman C, Ekqvist S, Moller H et al (2009) A correlation found between contact allergy to stent material and restenosis of the coronary arteries. Contact Dermatitis 60:158–164CrossRefPubMed
42.
Zurück zum Zitat Thyssen JP, Engkilde K, Menne T, Johansen JD, Hansen PR, Gislason GH (2011) No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis—results from a linkage study. Contact Dermatitis 64:138–141CrossRefPubMed Thyssen JP, Engkilde K, Menne T, Johansen JD, Hansen PR, Gislason GH (2011) No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis—results from a linkage study. Contact Dermatitis 64:138–141CrossRefPubMed
43.
Zurück zum Zitat Gimenez-Arnau A, Riambau V, Serra-Baldrich E, Camarasa JG (2000) Metal-induced generalized pruriginous dermatitis and endovascular surgery. Contact Dermatitis 43:35–40CrossRefPubMed Gimenez-Arnau A, Riambau V, Serra-Baldrich E, Camarasa JG (2000) Metal-induced generalized pruriginous dermatitis and endovascular surgery. Contact Dermatitis 43:35–40CrossRefPubMed
44.
Zurück zum Zitat Guerra A, Kirkwood M (2017) Severe generalized dermatitis in a nickel-allergic patient with a popliteal artery nitinol stent. J Vasc Surg Cases Innov Tech 3:23–25CrossRefPubMedPubMedCentral Guerra A, Kirkwood M (2017) Severe generalized dermatitis in a nickel-allergic patient with a popliteal artery nitinol stent. J Vasc Surg Cases Innov Tech 3:23–25CrossRefPubMedPubMedCentral
45.
Zurück zum Zitat Jetty P, Jayaram S, Veinot J, Pratt M (2013) Superficial femoral artery nitinol stent in a patient with nickel allergy. J Vasc Surg 58:1388–1390CrossRefPubMed Jetty P, Jayaram S, Veinot J, Pratt M (2013) Superficial femoral artery nitinol stent in a patient with nickel allergy. J Vasc Surg 58:1388–1390CrossRefPubMed
46.
Zurück zum Zitat D’Arrigo G, Giaquinta A, Virgilio C, Davi A, Pierfrancesco V, Veroux M (2014) Nickel allergy in a patient with a nitinol stent in the superficial femoral artery. J Vasc Interv Radiol 25:1304–1306CrossRefPubMed D’Arrigo G, Giaquinta A, Virgilio C, Davi A, Pierfrancesco V, Veroux M (2014) Nickel allergy in a patient with a nitinol stent in the superficial femoral artery. J Vasc Interv Radiol 25:1304–1306CrossRefPubMed
47.
Zurück zum Zitat Khan SF, Sherbondy MA, Ormsby A, Velanovich V (2007) Occlusion of metallic biliary stent related to nickel allergy. Gastrointest Endosc 66:413–414CrossRefPubMed Khan SF, Sherbondy MA, Ormsby A, Velanovich V (2007) Occlusion of metallic biliary stent related to nickel allergy. Gastrointest Endosc 66:413–414CrossRefPubMed
48.
Zurück zum Zitat Prestipino F, Pragliola C, Lusini M, Chello M (2014) Nickel allergy induced systemic reaction to an intracardiac amplatzer device. J Card Surg 29:349–350CrossRefPubMed Prestipino F, Pragliola C, Lusini M, Chello M (2014) Nickel allergy induced systemic reaction to an intracardiac amplatzer device. J Card Surg 29:349–350CrossRefPubMed
49.
Zurück zum Zitat Spina R, Muller DW, Jansz P, Gunalingam B (2016) Nickel hypersensitivity reaction following Amplatzer atrial septal defect occluder device deployment successfully treated by explantation of the device. Int J Cardiol 223:242–243CrossRefPubMed Spina R, Muller DW, Jansz P, Gunalingam B (2016) Nickel hypersensitivity reaction following Amplatzer atrial septal defect occluder device deployment successfully treated by explantation of the device. Int J Cardiol 223:242–243CrossRefPubMed
50.
Zurück zum Zitat Rigatelli G, Cardaioli P, Giordan M et al (2007) Nickel allergy in interatrial shunt device-based closure patients. Congenit Heart Dis 2:416–420CrossRefPubMed Rigatelli G, Cardaioli P, Giordan M et al (2007) Nickel allergy in interatrial shunt device-based closure patients. Congenit Heart Dis 2:416–420CrossRefPubMed
51.
Zurück zum Zitat Kang J, Simpson CS, Campbell D et al (2013) Cardiac rhythm device contact dermatitis. Ann Noninvasive Electrocardiol 18:79–83CrossRefPubMed Kang J, Simpson CS, Campbell D et al (2013) Cardiac rhythm device contact dermatitis. Ann Noninvasive Electrocardiol 18:79–83CrossRefPubMed
52.
Zurück zum Zitat Citerne O, Gomes S, Scanu P, Milliez P (2011) Painful Eczema mimicking pocket infection in a patient with an ICD: a rare cause of skin allergy to nickel/cobalt alloy. Circulation 123:1241–1242CrossRefPubMed Citerne O, Gomes S, Scanu P, Milliez P (2011) Painful Eczema mimicking pocket infection in a patient with an ICD: a rare cause of skin allergy to nickel/cobalt alloy. Circulation 123:1241–1242CrossRefPubMed
53.
Zurück zum Zitat Andrews ID, Scheinman P (2011) Systemic hypersensitivity reaction (without cutaneous manifestations) to an implantable cardioverter-defibrillator. Dermatitis 22:161–164PubMed Andrews ID, Scheinman P (2011) Systemic hypersensitivity reaction (without cutaneous manifestations) to an implantable cardioverter-defibrillator. Dermatitis 22:161–164PubMed
54.
Zurück zum Zitat Abdallah HI, Balsara RK, O’Riordan AC (1994) Pacemaker contact sensitivity: clinical recognition and management. Ann Thorac Surg 57:1017–1018CrossRefPubMed Abdallah HI, Balsara RK, O’Riordan AC (1994) Pacemaker contact sensitivity: clinical recognition and management. Ann Thorac Surg 57:1017–1018CrossRefPubMed
55.
Zurück zum Zitat Delaplace M, Maitre F, Dufour T et al (2010) Two cases of cutaneous erythema following spinal cord stimulation. Ann Dermatol Venereol 137:297–300CrossRefPubMed Delaplace M, Maitre F, Dufour T et al (2010) Two cases of cutaneous erythema following spinal cord stimulation. Ann Dermatol Venereol 137:297–300CrossRefPubMed
56.
Zurück zum Zitat Taverner MG (2013) A case of an allergic reaction to a spinal cord stimulator: identification of the antigen with epicutaneous patch testing, allowing successful reimplantation. Neuromodulation 16:595–599CrossRefPubMed Taverner MG (2013) A case of an allergic reaction to a spinal cord stimulator: identification of the antigen with epicutaneous patch testing, allowing successful reimplantation. Neuromodulation 16:595–599CrossRefPubMed
57.
Zurück zum Zitat Schmidlin K, Verzwyvelt J, Bernstein D, Kim H (2015) Probable delayed-type hypersensitivity to nickel-containing cerebral aneurysm clip associated with neurologic deficits. J Allergy Clin Immunol Pract 3:609–611CrossRefPubMed Schmidlin K, Verzwyvelt J, Bernstein D, Kim H (2015) Probable delayed-type hypersensitivity to nickel-containing cerebral aneurysm clip associated with neurologic deficits. J Allergy Clin Immunol Pract 3:609–611CrossRefPubMed
58.
Zurück zum Zitat Gautschi OP, Schlett CL, Fournier JY, Cadosch D (2010) Laboratory confirmed polymethyl-methacrylate (Palacos)-hypersensitivity after cranioplasty. Clin Neurol Neurosurg 112:915–916CrossRefPubMed Gautschi OP, Schlett CL, Fournier JY, Cadosch D (2010) Laboratory confirmed polymethyl-methacrylate (Palacos)-hypersensitivity after cranioplasty. Clin Neurol Neurosurg 112:915–916CrossRefPubMed
59.
Zurück zum Zitat King L Jr, Fransway A, Adkins RB (1993) Chronic urticaria due to surgical clips. N Engl J Med 329:1583–1584CrossRefPubMed King L Jr, Fransway A, Adkins RB (1993) Chronic urticaria due to surgical clips. N Engl J Med 329:1583–1584CrossRefPubMed
60.
Zurück zum Zitat Fage SW, Muris J, Jakobsen SS, Thyssen JP (2016) Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity. Contact Dermatitis 74:323–345CrossRefPubMed Fage SW, Muris J, Jakobsen SS, Thyssen JP (2016) Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity. Contact Dermatitis 74:323–345CrossRefPubMed
61.
Zurück zum Zitat Keane FM, Morris SD, Smith HR, Rycroft RJ (2001) Allergy in coronary in-stent restenosis. Lancet 357:1205–1206 author reply 1206–1207CrossRefPubMed Keane FM, Morris SD, Smith HR, Rycroft RJ (2001) Allergy in coronary in-stent restenosis. Lancet 357:1205–1206 author reply 1206–1207CrossRefPubMed
62.
Zurück zum Zitat Goon AT, Bruze M, Zimerson E et al (2011) Variation in allergen content over time of acrylates/methacrylates in patch test preparations. Br J Dermatol 164:116–124CrossRefPubMed Goon AT, Bruze M, Zimerson E et al (2011) Variation in allergen content over time of acrylates/methacrylates in patch test preparations. Br J Dermatol 164:116–124CrossRefPubMed
63.
Zurück zum Zitat Goon AT, Bruze M, Zimerson E et al (2011) Correlation between stated and measured concentrations of acrylate and methacrylate allergens in patch-test preparations. Dermatitis 22:27–32PubMed Goon AT, Bruze M, Zimerson E et al (2011) Correlation between stated and measured concentrations of acrylate and methacrylate allergens in patch-test preparations. Dermatitis 22:27–32PubMed
64.
Zurück zum Zitat Pacheco K, Barker L, Maier L, Erb S, Sills M, Knight V (2013) Development of a validated blood test for nickel sensitization. J Allergy Clin Immunol 132:767–769CrossRefPubMed Pacheco K, Barker L, Maier L, Erb S, Sills M, Knight V (2013) Development of a validated blood test for nickel sensitization. J Allergy Clin Immunol 132:767–769CrossRefPubMed
Metadaten
Titel
Allergy to Surgical Implants
verfasst von
Karin A. Pacheco
Publikationsdatum
15.09.2018
Verlag
Springer US
Erschienen in
Clinical Reviews in Allergy & Immunology / Ausgabe 1/2019
Print ISSN: 1080-0549
Elektronische ISSN: 1559-0267
DOI
https://doi.org/10.1007/s12016-018-8707-y

Weitere Artikel der Ausgabe 1/2019

Clinical Reviews in Allergy & Immunology 1/2019 Zur Ausgabe

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.