Skip to main content
Erschienen in: Journal of Robotic Surgery 1/2012

01.03.2012 | Original Article

An effective visualisation and registration system for image-guided robotic partial nephrectomy

verfasst von: Philip Pratt, Erik Mayer, Justin Vale, Daniel Cohen, Eddie Edwards, Ara Darzi, Guang-Zhong Yang

Erschienen in: Journal of Robotic Surgery | Ausgabe 1/2012

Einloggen, um Zugang zu erhalten

Abstract

Robotic partial nephrectomy is presently the fastest-growing robotic surgical procedure, and in comparison to traditional techniques it offers reduced tissue trauma and likelihood of post-operative infection, while hastening recovery time and improving cosmesis. It is also an ideal candidate for image guidance technology since soft tissue deformation, while still present, is localised and less problematic compared to other surgical procedures. This work describes the implementation and ongoing development of an effective image guidance system that aims to address some of the remaining challenges in this area. Specific innovations include the introduction of an intuitive, partially automated registration interface, and the use of a hardware platform that makes sophisticated augmented reality overlays practical in real time. Results and examples of image augmentation are presented from both retrospective and live cases. Quantitative analysis of registration error verifies that the proposed registration technique is appropriate for the chosen image guidance targets.
Literatur
1.
Zurück zum Zitat Gautam G, Benway BM, Bhayani SB, Zorn KC (2009) Robot assisted partial nephrectomy: current perspectives and future prospects. Urology 74(4):735–740PubMedCrossRef Gautam G, Benway BM, Bhayani SB, Zorn KC (2009) Robot assisted partial nephrectomy: current perspectives and future prospects. Urology 74(4):735–740PubMedCrossRef
2.
Zurück zum Zitat Teber D, Guven S, Simpfendörfer T, Baumhauer M, Güven EO, Yencilek F, Gözen AS, Rassweiler J (2009) Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy? Preliminary in vitro and in vivo results. Eur Urol 56(2):332–338 (Epub 2009 May 19) Teber D, Guven S, Simpfendörfer T, Baumhauer M, Güven EO, Yencilek F, Gözen AS, Rassweiler J (2009) Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy? Preliminary in vitro and in vivo results. Eur Urol 56(2):332–338 (Epub 2009 May 19)
3.
Zurück zum Zitat Altamar HO, Ong RE, Glisson CL, Viprakasit DP, Miga MI, Herrell SD, Galloway RL (2011) Kidney deformation and intraprocedural registration: a study of elements of image-guided kidney surgery. J Endourol 25(3):511–517 (Epub 2010 Dec 13) Altamar HO, Ong RE, Glisson CL, Viprakasit DP, Miga MI, Herrell SD, Galloway RL (2011) Kidney deformation and intraprocedural registration: a study of elements of image-guided kidney surgery. J Endourol 25(3):511–517 (Epub 2010 Dec 13)
4.
Zurück zum Zitat Su LM, Vagvolgyi BP, Agarwal R, Reiley CE, Taylor RH, Hager GD (2009) Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration. Urology 73(4):896–900 (Epub 2009 Feb 4) Su LM, Vagvolgyi BP, Agarwal R, Reiley CE, Taylor RH, Hager GD (2009) Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration. Urology 73(4):896–900 (Epub 2009 Feb 4)
5.
Zurück zum Zitat Stolka P, Keil M, Sakas G, McVeigh E, Allaf M, Taylor R, Boctor E (2010) A 3D-elastography-guided system for laparoscopic partial nephrectomies. In: Proceedings of SPIE 7625, 76251I-1 Stolka P, Keil M, Sakas G, McVeigh E, Allaf M, Taylor R, Boctor E (2010) A 3D-elastography-guided system for laparoscopic partial nephrectomies. In: Proceedings of SPIE 7625, 76251I-1
7.
Zurück zum Zitat Kirk D, Hwu W (2010) Programming massively parallel processors: A hands-on approach. Morgan Kaufmann, Burlington, MA Kirk D, Hwu W (2010) Programming massively parallel processors: A hands-on approach. Morgan Kaufmann, Burlington, MA
8.
Zurück zum Zitat Rost RJ, Licea-Kane B, Ginsburg D, Kessenich JM, Barthold L, Malan H, Weiblen M (2009) The OpenGL Shading Language. Addison-Wesley Professional, Boston, MA Rost RJ, Licea-Kane B, Ginsburg D, Kessenich JM, Barthold L, Malan H, Weiblen M (2009) The OpenGL Shading Language. Addison-Wesley Professional, Boston, MA
9.
Zurück zum Zitat Lerotic M, Chung A, Mylonas G, Yang G-Z (2007) pq-Space based non-photorealistic rendering for augmented reality. MICCAI Part II. LNCS 4792:102–109 Lerotic M, Chung A, Mylonas G, Yang G-Z (2007) pq-Space based non-photorealistic rendering for augmented reality. MICCAI Part II. LNCS 4792:102–109
10.
Zurück zum Zitat Miller K, Joldes G, Lance D, Wittek A (2007) Total Lagrangian explicit dynamics finite element algorithm for computing soft tissue deformation. Commun Numer Methods Eng 23(2007):121–134 Miller K, Joldes G, Lance D, Wittek A (2007) Total Lagrangian explicit dynamics finite element algorithm for computing soft tissue deformation. Commun Numer Methods Eng 23(2007):121–134
11.
Zurück zum Zitat Yushkevich P, Piven J, Cody Hazlett H, Gimpel Smith R, Ho S, Gee J, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures. Neuroimage 31(3):1116–1128PubMedCrossRef Yushkevich P, Piven J, Cody Hazlett H, Gimpel Smith R, Ho S, Gee J, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures. Neuroimage 31(3):1116–1128PubMedCrossRef
13.
Zurück zum Zitat Geuzaine C, Remacle JF (2009) Gmsh: a three-dimensional finite element mesh generator with built-in pre- and post-processing facilities. Int J Numer Methods Eng 79(11):1309–1331CrossRef Geuzaine C, Remacle JF (2009) Gmsh: a three-dimensional finite element mesh generator with built-in pre- and post-processing facilities. Int J Numer Methods Eng 79(11):1309–1331CrossRef
14.
Zurück zum Zitat Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334CrossRef Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334CrossRef
15.
Zurück zum Zitat Stoyanov D, Mylonas GP, Deligianni F, Darzi A, Yang G-Z (2005) Soft-tissue motion tracking and structure estimation for robotic assisted MIS procedures. MICCAI Part II. LNCS 3750:139–146 Stoyanov D, Mylonas GP, Deligianni F, Darzi A, Yang G-Z (2005) Soft-tissue motion tracking and structure estimation for robotic assisted MIS procedures. MICCAI Part II. LNCS 3750:139–146
16.
Zurück zum Zitat Bradski A, Kaehler A (2008) Learning OpenCV: computer vision with the OpenCV library. O'Reilly Media Inc., Sebastopol, CA Bradski A, Kaehler A (2008) Learning OpenCV: computer vision with the OpenCV library. O'Reilly Media Inc., Sebastopol, CA
17.
Zurück zum Zitat Moller T, Trumbore B (1997) Fast, minimum storage ray-triangle intersection. J Graphics Tools 2(1):21–28 Moller T, Trumbore B (1997) Fast, minimum storage ray-triangle intersection. J Graphics Tools 2(1):21–28
18.
Zurück zum Zitat Hanson A (1992) The rolling ball. In: Graphics Gems III. San Diego, Academic Press Professional, pp 51–60 Hanson A (1992) The rolling ball. In: Graphics Gems III. San Diego, Academic Press Professional, pp 51–60
19.
Zurück zum Zitat Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am 4(4):629–642CrossRef Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am 4(4):629–642CrossRef
20.
Zurück zum Zitat Alleemudder A, Dudderidge T, Rao AR, Mayer EK, Hrouda D, Vale JA, Khoubehi B (2011) Feasibility of robotic partial nephrectomy in a UK Cancer Centre. Br J Med Surg Urol 4:78–85CrossRef Alleemudder A, Dudderidge T, Rao AR, Mayer EK, Hrouda D, Vale JA, Khoubehi B (2011) Feasibility of robotic partial nephrectomy in a UK Cancer Centre. Br J Med Surg Urol 4:78–85CrossRef
21.
Zurück zum Zitat Ljungberg B, Cowan NC, Hanbury DC, Hora M, Kuczyk MA, Merseburger AS, Patard J-J, Mulders PFA, Sinescu IC (2010) EAU guidelines on renal cell carcinoma: the 2010 update. Eur Urol 58(3):398–406PubMedCrossRef Ljungberg B, Cowan NC, Hanbury DC, Hora M, Kuczyk MA, Merseburger AS, Patard J-J, Mulders PFA, Sinescu IC (2010) EAU guidelines on renal cell carcinoma: the 2010 update. Eur Urol 58(3):398–406PubMedCrossRef
22.
Zurück zum Zitat Benway BM, Bhayani SB, Rogers CG, Porter JR, Buffi NM, Figenshau RS, Mottrie A (2010) Robot-assisted partial nephrectomy: an international experience. Eur Urol 57(5):815–820 (Epub 2010 Jan 22) Benway BM, Bhayani SB, Rogers CG, Porter JR, Buffi NM, Figenshau RS, Mottrie A (2010) Robot-assisted partial nephrectomy: an international experience. Eur Urol 57(5):815–820 (Epub 2010 Jan 22)
23.
Zurück zum Zitat Lam JS, Bergman J, Breda A, Schulam PG (2008) Importance of surgical margins in the management of renal cell carcinoma. Nat Clin Pract Urol 5(6):308–317 (Epub 2008 May 13) Lam JS, Bergman J, Breda A, Schulam PG (2008) Importance of surgical margins in the management of renal cell carcinoma. Nat Clin Pract Urol 5(6):308–317 (Epub 2008 May 13)
24.
Zurück zum Zitat Herrell SD, Kwartowitz DM, Milhoua PM, Galloway RL (2009) Toward image guided robotic surgery: system validation. J Urol 181(2):783–789 (discussion 789–790) (Epub 2008 Dec 16) Herrell SD, Kwartowitz DM, Milhoua PM, Galloway RL (2009) Toward image guided robotic surgery: system validation. J Urol 181(2):783–789 (discussion 789–790) (Epub 2008 Dec 16)
25.
Zurück zum Zitat Cheung C, Wedlake C, Moore J, Paulter S, Peters T (2010) Fused video and ultrasound for minimally invasive partial nephrectomy: a phantom study. MICCAI Part III. LNCS 6363:408–415 Cheung C, Wedlake C, Moore J, Paulter S, Peters T (2010) Fused video and ultrasound for minimally invasive partial nephrectomy: a phantom study. MICCAI Part III. LNCS 6363:408–415
26.
Zurück zum Zitat Pratt P, Stoyanov D, Visentini-Scarzanella M, Yang G-Z (2010) Dynamic guidance for robotic surgery using image-constrained biomechanical models. MICCAI Part I. LNCS 6361:77–85 Pratt P, Stoyanov D, Visentini-Scarzanella M, Yang G-Z (2010) Dynamic guidance for robotic surgery using image-constrained biomechanical models. MICCAI Part I. LNCS 6361:77–85
Metadaten
Titel
An effective visualisation and registration system for image-guided robotic partial nephrectomy
verfasst von
Philip Pratt
Erik Mayer
Justin Vale
Daniel Cohen
Eddie Edwards
Ara Darzi
Guang-Zhong Yang
Publikationsdatum
01.03.2012
Verlag
Springer-Verlag
Erschienen in
Journal of Robotic Surgery / Ausgabe 1/2012
Print ISSN: 1863-2483
Elektronische ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-011-0334-z

Weitere Artikel der Ausgabe 1/2012

Journal of Robotic Surgery 1/2012 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.