Skip to main content
Erschienen in:

10.06.2024 | Original Article

Anatomical study of the safety corridor for bridge plating positioned on the lateral border of the humerus

verfasst von: Lourenço Galizia Heitzmann, Igel de Souza Aquino, Antonio Carlos Tenor Junior, Miguel Pereira da Costa, Monica Paschoal Nogueira

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 9/2024

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study shows the danger zone and the safety corridor in the lateral approach with bridge plating by measuring the distance between the lateral side of the plate positioned on the lateral aspect of the humerus and the radial nerve after it pierces the lateral intermuscular septum, in the different forearm positions.

Methods

Forty arms of 20 human cadavers were used, the radial nerve was identified and marked on the lateral surface the radial nerve at the exit of the lateral intermuscular septum and anteriorisation of the nerve in relation to the humeral shaft and the lateral epicondyle was also marked. The distances were measured with a digital caliper. A submuscular extraperiosteal corridor was created, proximally between the biceps brachialis and deltoid muscle and distally between the triceps and brachioradialis muscle, followed by the positioning of the low contact large fragments contoured plate with 14 combined holes (fixed and cortical angle), inserted from distal to proximal. Measurements were performed in four positions (elbow flexion with forearm pronation, elbow flexion with forearm supination, elbow extension with forearm pronation and elbow extension with forearm supination).

Results

Significant statistical differences occurred with the different positions, and the elbow flexion with forearm supination was shown to be the position that provides the safest submuscular extraperiosteal corridor in a lateral approach of the humerus.

Conclusion

The danger zone of radial nerve is an area that extends from 15 cm to 5 cm proximal to the lateral epicondyle and the safest way to create a submuscular and extraperiosteal corridor in the lateral region of the humerus is with the elbow in flexion and the forearm in supination.
Literatur
1.
Zurück zum Zitat An Z, He X, Jiang C et al (2010) [Comparison of effectiveness between minimally invasive plating osteosynthesis and expandable intramedullary nailing technique in treatment of middle third humeral shaft fractures]. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 24:1413–1415PubMed An Z, He X, Jiang C et al (2010) [Comparison of effectiveness between minimally invasive plating osteosynthesis and expandable intramedullary nailing technique in treatment of middle third humeral shaft fractures]. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 24:1413–1415PubMed
2.
Zurück zum Zitat Apivatthakakul T (2007) Humerus, shaft. in: Tong (ed) AO Manual of Fracture Management. Minimally invasive plate osteosynthesis (MIPO). Thieme, Stuttgart, pp 152–153 Apivatthakakul T (2007) Humerus, shaft. in: Tong (ed) AO Manual of Fracture Management. Minimally invasive plate osteosynthesis (MIPO). Thieme, Stuttgart, pp 152–153
12.
Zurück zum Zitat Holstein A, Lewis GM (1963) Fractures of the humerus with radial-nerve paralysis. J Bone Joint Surg Am 45:1382–1388CrossRefPubMed Holstein A, Lewis GM (1963) Fractures of the humerus with radial-nerve paralysis. J Bone Joint Surg Am 45:1382–1388CrossRefPubMed
17.
Zurück zum Zitat Kulkarni VS, Kulkarni MS, Kulkarni GS et al (2017) Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plate osteosynthesis (MIPO) in treatment of humerus diaphyseal fractures. https://doi.org/10.1016/S0020-1383(17)30487-4. Injury Kulkarni VS, Kulkarni MS, Kulkarni GS et al (2017) Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plate osteosynthesis (MIPO) in treatment of humerus diaphyseal fractures. https://​doi.​org/​10.​1016/​S0020-1383(17)30487-4. Injury
Metadaten
Titel
Anatomical study of the safety corridor for bridge plating positioned on the lateral border of the humerus
verfasst von
Lourenço Galizia Heitzmann
Igel de Souza Aquino
Antonio Carlos Tenor Junior
Miguel Pereira da Costa
Monica Paschoal Nogueira
Publikationsdatum
10.06.2024
Verlag
Springer Paris
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 9/2024
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-024-03405-x

Neu im Fachgebiet Radiologie

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

PMBCL mit CMR: Radiatio kann ohne Risiko weggelassen werden

Patienten mit primär mediastinalem B-Zell-Lymphom (PMBCL), die nach der Induktionstherapie eine komplette metabolische Remission (CMR) erreichen und keine konsolidierende Bestrahlung erhalten, müssen offenbar keine Überlebensnachteile fürchten.

Hypoxisch-ischämische Enzephalopathie: Indikatoren für eine ungünstige Prognose

Eine US-amerikanische Studie widmete sich der Identifizierung prognostischer Parameter bei Neugeborenen mit mittelschwerer oder schwerer hypoxisch-ischämischer Enzephalopathie (HIE), die mittels induzierter Hypoxie behandelt wurden. Besonders im 24-Stunden-EEG und der MRT konnten relevante Hinweise gefunden werden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.