Skip to main content
Erschienen in: Journal of Digital Imaging 1/2011

01.02.2011

Anatomically Anchored Template-Based Level Set Segmentation: Application to Quadriceps Muscles in MR Images from the Osteoarthritis Initiative

verfasst von: Jeffrey W. Prescott, Thomas M. Best, Mark S. Swanson, Furqan Haq, Rebecca D. Jackson, Metin N. Gurcan

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

In this paper, we present a semi-automated segmentation method for magnetic resonance images of the quadriceps muscles. Our method uses an anatomically anchored, template-based initialization of the level set-based segmentation approach. The method only requires the input of a single point from the user inside the rectus femoris. The templates are quantitatively selected from a set of images based on modes in the patient population, namely, sex and body type. For a given image to be segmented, a template is selected based on the smallest Kullback–Leibler divergence between the histograms of that image and the set of templates. The chosen template is then employed as an initialization for a level set segmentation, which captures individual anatomical variations in the image to be segmented. Images from 103 subjects were analyzed using the developed method. The algorithm was trained on a randomly selected subset of 50 subjects (25 men and 25 women) and tested on the remaining 53 subjects. The performance of the algorithm on the test set was compared against the ground truth using the Zijdenbos similarity index (ZSI). The average ZSI means and standard deviations against two different manual readers were as follows: rectus femoris, 0.78 ± 0.12; vastus intermedius, 0.79 ± 0.10; vastus lateralis, 0.82 ± 0.08; and vastus medialis, 0.69 ± 0.16.
Literatur
1.
Zurück zum Zitat Felson DT, Lawrence RC, Dieppe PA, et al: Osteoarthritis: new insights. Part 1: the disease and its risk factors. Ann Intern Med 133:635–646, 2000PubMed Felson DT, Lawrence RC, Dieppe PA, et al: Osteoarthritis: new insights. Part 1: the disease and its risk factors. Ann Intern Med 133:635–646, 2000PubMed
2.
Zurück zum Zitat Buckwalter JA, Einhorn TA, Simon SR, American Academy of Orthopaedic Surgeons: Orthopaedic Basic Science Biology and Biomechanics of the Musculoskeletal System, Rosemont: American Academy of Orthopaedic Surgeons, 2000 Buckwalter JA, Einhorn TA, Simon SR, American Academy of Orthopaedic Surgeons: Orthopaedic Basic Science Biology and Biomechanics of the Musculoskeletal System, Rosemont: American Academy of Orthopaedic Surgeons, 2000
4.
Zurück zum Zitat Baker KR, Xu L, Zhang Y, Nevitt M, Niu J, Aliabadi P, Yu W, Felson D: Quadriceps weakness and its relationship to tibiofemoral and patellafemoral knee osteoarthritis in Chinese. Arthritis Rheum 50:1815–1821, 2004CrossRefPubMed Baker KR, Xu L, Zhang Y, Nevitt M, Niu J, Aliabadi P, Yu W, Felson D: Quadriceps weakness and its relationship to tibiofemoral and patellafemoral knee osteoarthritis in Chinese. Arthritis Rheum 50:1815–1821, 2004CrossRefPubMed
5.
Zurück zum Zitat Slemenda CW, Heilman DK, Brandt KD, Katz BP, Mazzuca SA, Braunstein EM, Byrd D: Reduced quadriceps strength relative to body weight: a risk factor for knee osteoarthritis in women? Arthritis Rheum 41:1951–1959, 1998CrossRefPubMed Slemenda CW, Heilman DK, Brandt KD, Katz BP, Mazzuca SA, Braunstein EM, Byrd D: Reduced quadriceps strength relative to body weight: a risk factor for knee osteoarthritis in women? Arthritis Rheum 41:1951–1959, 1998CrossRefPubMed
6.
Zurück zum Zitat Brandt KD, Heilman DK, Slemenda CW, Katz BP, Mazzuca SA, Braunstein EM, Byrd D: Quadriceps strength in women with radiographically progressive osteoarthritis of the knee and those with stable radiographic changes. J Rheumatol 26:2431–2437, 1999PubMed Brandt KD, Heilman DK, Slemenda CW, Katz BP, Mazzuca SA, Braunstein EM, Byrd D: Quadriceps strength in women with radiographically progressive osteoarthritis of the knee and those with stable radiographic changes. J Rheumatol 26:2431–2437, 1999PubMed
7.
Zurück zum Zitat Cooper C, Snow S, McAlindon TE, Kellingray S, Stuart B, Coggon D, Dieppe PA: Risk factors for the incidence and progression of radiographic knee osteoarthritis. Arthritis Rheum 43:995, 2000CrossRefPubMed Cooper C, Snow S, McAlindon TE, Kellingray S, Stuart B, Coggon D, Dieppe PA: Risk factors for the incidence and progression of radiographic knee osteoarthritis. Arthritis Rheum 43:995, 2000CrossRefPubMed
8.
Zurück zum Zitat Klein CS, Rice CL, Marsh GD: Normalized force, activation, and coactivation in the arm muscles of young and old men. J Appl Physiol 91(3):1341–1349, 2001PubMed Klein CS, Rice CL, Marsh GD: Normalized force, activation, and coactivation in the arm muscles of young and old men. J Appl Physiol 91(3):1341–1349, 2001PubMed
9.
Zurück zum Zitat Morse CI, Thom JM, Reeves ND, Birch KM, Narici MV: In vivo physiological cross-sectional area and specific force are reduced in the gastrocnemius of elderly men. J Appl Physiol 99(3):1050–1055, 2005CrossRefPubMed Morse CI, Thom JM, Reeves ND, Birch KM, Narici MV: In vivo physiological cross-sectional area and specific force are reduced in the gastrocnemius of elderly men. J Appl Physiol 99(3):1050–1055, 2005CrossRefPubMed
10.
Zurück zum Zitat Morse CI, Degens H, Jones DA: The validity of estimating quadriceps volume from single MRI cross-sections of young men. Eur J Appl Physiol 100:267–274, 2007CrossRefPubMed Morse CI, Degens H, Jones DA: The validity of estimating quadriceps volume from single MRI cross-sections of young men. Eur J Appl Physiol 100:267–274, 2007CrossRefPubMed
11.
Zurück zum Zitat Stammberger T, Eckstein F, Michaelis M, Englmeier KH, Reiser M: Interobserver reproducibility of quantitative cartilage measurements: comparison of B-spline snakes and manual segmentation. Magn Reson Imaging 17:1033–1042, 1999CrossRefPubMed Stammberger T, Eckstein F, Michaelis M, Englmeier KH, Reiser M: Interobserver reproducibility of quantitative cartilage measurements: comparison of B-spline snakes and manual segmentation. Magn Reson Imaging 17:1033–1042, 1999CrossRefPubMed
12.
Zurück zum Zitat Duryea J, Neumann G, Brem MH, Koh W, Noorbakhsh F, Jackson RD, Yu J, Eaton CB, Lang P: Novel fast semi-automated software to segment cartilage for knee MR acquisitions. Osteoarthr Cartil 15(5):487–492, 2007CrossRefPubMed Duryea J, Neumann G, Brem MH, Koh W, Noorbakhsh F, Jackson RD, Yu J, Eaton CB, Lang P: Novel fast semi-automated software to segment cartilage for knee MR acquisitions. Osteoarthr Cartil 15(5):487–492, 2007CrossRefPubMed
13.
Zurück zum Zitat Solloway S, Hutchinson CE, Waterton JC, Taylor CJ: The use of active shape models for making thickness measurements of articular cartilage from MR images. Magn Reson Med 37:943–952, 1997CrossRefPubMed Solloway S, Hutchinson CE, Waterton JC, Taylor CJ: The use of active shape models for making thickness measurements of articular cartilage from MR images. Magn Reson Med 37:943–952, 1997CrossRefPubMed
14.
Zurück zum Zitat Lynch JA, Zaim S, Zhao J, Stork A, Peterfy C, Genant HK: Cartilage segmentation of 3D MRO scans of the osteoarthritic knee combining user knowledge and active contours. Proc SPIE 3979:925–35, 2000CrossRef Lynch JA, Zaim S, Zhao J, Stork A, Peterfy C, Genant HK: Cartilage segmentation of 3D MRO scans of the osteoarthritic knee combining user knowledge and active contours. Proc SPIE 3979:925–35, 2000CrossRef
15.
Zurück zum Zitat Gougoutas AJ, Wheaton AJ, Borthakur A, Shapiro EM, Kneeland BJ, Udupa JK, Reddy R: Cartilage volume quantification via Live Wire segmentation. Acad Rad 11(12):1389–1395, 2004CrossRef Gougoutas AJ, Wheaton AJ, Borthakur A, Shapiro EM, Kneeland BJ, Udupa JK, Reddy R: Cartilage volume quantification via Live Wire segmentation. Acad Rad 11(12):1389–1395, 2004CrossRef
16.
Zurück zum Zitat Steines D, Cheng C, Wong J, Tsai S, Napel P, Lang P: Segmentation of osteoarthritic femoral cartilage using live wire. Proc Int Soc Magn Reson Med 8:220, 2000 Steines D, Cheng C, Wong J, Tsai S, Napel P, Lang P: Segmentation of osteoarthritic femoral cartilage using live wire. Proc Int Soc Magn Reson Med 8:220, 2000
17.
Zurück zum Zitat Kuk J, Ross R: Measurement of body composition in obesity. In: Kushner R, Bessesen D Eds. Contemporary Endocrinology: Treatment of the Obese Patient. Totowa: Humana Press, 2007 Kuk J, Ross R: Measurement of body composition in obesity. In: Kushner R, Bessesen D Eds. Contemporary Endocrinology: Treatment of the Obese Patient. Totowa: Humana Press, 2007
18.
Zurück zum Zitat Mitsiopoulos N, Baumgartner RN, Heymsfield SB, Lyons W, Gallagher D, Ross R: Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography. J Appl Physiol 85:115–122, 1998PubMed Mitsiopoulos N, Baumgartner RN, Heymsfield SB, Lyons W, Gallagher D, Ross R: Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography. J Appl Physiol 85:115–122, 1998PubMed
19.
Zurück zum Zitat Gargiulo P, Vatnsdal B, Ingvarsson P, Knútsdóttir S, Gudmundsdóttir V, Yngvason S, Helgason T: Restoration of muscle volume and shape induced by electrical stimulation of denervated degenerated muscles: qualitative and quantitative measurement of changes in rectus femoris using computer tomography and image segmentation. Artif Organs 32(8):609–613, 2008CrossRefPubMed Gargiulo P, Vatnsdal B, Ingvarsson P, Knútsdóttir S, Gudmundsdóttir V, Yngvason S, Helgason T: Restoration of muscle volume and shape induced by electrical stimulation of denervated degenerated muscles: qualitative and quantitative measurement of changes in rectus femoris using computer tomography and image segmentation. Artif Organs 32(8):609–613, 2008CrossRefPubMed
20.
Zurück zum Zitat Nevitt MC, Felson DT, Lester G: The Osteoarthritis Initiative: Protocol for the Cohort Study, v. 1.1. June 21, 2006 Nevitt MC, Felson DT, Lester G: The Osteoarthritis Initiative: Protocol for the Cohort Study, v. 1.1. June 21, 2006
21.
Zurück zum Zitat Kellgren J, Lawrence J: Radiological assessment of osteoarthritis. Ann Rheum Dis 16:494–501, 1957CrossRefPubMed Kellgren J, Lawrence J: Radiological assessment of osteoarthritis. Ann Rheum Dis 16:494–501, 1957CrossRefPubMed
22.
Zurück zum Zitat Haacke EM: Magnetic resonance imaging: Physical principles and sequence design, New York: Wiley, 1999 Haacke EM: Magnetic resonance imaging: Physical principles and sequence design, New York: Wiley, 1999
23.
Zurück zum Zitat Sled JG, Zijdenbos AP, Evans AC: A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans Med Imag 17(1):87–97, 1998CrossRef Sled JG, Zijdenbos AP, Evans AC: A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans Med Imag 17(1):87–97, 1998CrossRef
24.
Zurück zum Zitat Madabhushi A, Udupa JK: Interplay between intensity standardization and inhomogeneity correction in mr image processing. IEEE Trans Med Img 24(5):561–576, 2005CrossRef Madabhushi A, Udupa JK: Interplay between intensity standardization and inhomogeneity correction in mr image processing. IEEE Trans Med Img 24(5):561–576, 2005CrossRef
25.
Zurück zum Zitat Prescott JW, Priddy M, Swanson MS, Haq F, Best TM, Powell K, Jackson R, Gurcan MN: An Automated Method for Intramuscular Fat Detection in Quadriceps Muscles for Osteoarthritis Diagnosis. EMBC 2009, Minneapolis, MN, Sept. 2–6, 2009 Prescott JW, Priddy M, Swanson MS, Haq F, Best TM, Powell K, Jackson R, Gurcan MN: An Automated Method for Intramuscular Fat Detection in Quadriceps Muscles for Osteoarthritis Diagnosis. EMBC 2009, Minneapolis, MN, Sept. 2–6, 2009
26.
Zurück zum Zitat Parzen E: On estimation of a probability density function and mode. Ann Math Stat 33(3):1065–1076, 1962CrossRef Parzen E: On estimation of a probability density function and mode. Ann Math Stat 33(3):1065–1076, 1962CrossRef
27.
Zurück zum Zitat Duda RO, Hart PE: Pattern Classification, New York: Wiley, 2001 Duda RO, Hart PE: Pattern Classification, New York: Wiley, 2001
28.
Zurück zum Zitat Cover TM, Thomas JA: Elements of Information Theory, New York: Wiley, 1991CrossRef Cover TM, Thomas JA: Elements of Information Theory, New York: Wiley, 1991CrossRef
29.
Zurück zum Zitat Gonzalez RC, Woods RE: Digital Image Processing, Upper Saddle River: Prentice Hall, 2002 Gonzalez RC, Woods RE: Digital Image Processing, Upper Saddle River: Prentice Hall, 2002
30.
Zurück zum Zitat Prescott JW, Swanson MS, Haq F, Best TM, Powell K, Jackson R, Gurcan MN: An Automated Method for Femur Segmentation for Osteoarthritis Research,” EMBC 2009, Minneapolis, MN, Sept. 2–6, 2009 Prescott JW, Swanson MS, Haq F, Best TM, Powell K, Jackson R, Gurcan MN: An Automated Method for Femur Segmentation for Osteoarthritis Research,” EMBC 2009, Minneapolis, MN, Sept. 2–6, 2009
31.
Zurück zum Zitat Mitsiopoulos N, Baumgartner RN, Hemsfield SB, Lyons W, Gallagher D, Ross R: Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography. J Appl Physiol 85:115–122, 1998PubMed Mitsiopoulos N, Baumgartner RN, Hemsfield SB, Lyons W, Gallagher D, Ross R: Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography. J Appl Physiol 85:115–122, 1998PubMed
32.
Zurück zum Zitat Perona P, Malik J: Scale-space and edge detection using anisotropic diffusion. IEEE Trans Patt Anal Mach Intell 12(7):629–639, 1990CrossRef Perona P, Malik J: Scale-space and edge detection using anisotropic diffusion. IEEE Trans Patt Anal Mach Intell 12(7):629–639, 1990CrossRef
33.
Zurück zum Zitat Li C, Xu C, Gui C, Fox MD: Level set evolution without re-initialization: a new variational formulation. IEEE Conf Comp Vis Patt Recog 1:430–436, 2005 Li C, Xu C, Gui C, Fox MD: Level set evolution without re-initialization: a new variational formulation. IEEE Conf Comp Vis Patt Recog 1:430–436, 2005
34.
Zurück zum Zitat Zijdenbos AP, Dawant BM, Margolin RA, Palmer AC: Morphometric analysis of white matter lesions in MR images: Method and validation. IEEE Trans Med Imag 13:716–724, 1994CrossRef Zijdenbos AP, Dawant BM, Margolin RA, Palmer AC: Morphometric analysis of white matter lesions in MR images: Method and validation. IEEE Trans Med Imag 13:716–724, 1994CrossRef
35.
Zurück zum Zitat Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 33(1):159–174, 1977CrossRefPubMed Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 33(1):159–174, 1977CrossRefPubMed
Metadaten
Titel
Anatomically Anchored Template-Based Level Set Segmentation: Application to Quadriceps Muscles in MR Images from the Osteoarthritis Initiative
verfasst von
Jeffrey W. Prescott
Thomas M. Best
Mark S. Swanson
Furqan Haq
Rebecca D. Jackson
Metin N. Gurcan
Publikationsdatum
01.02.2011
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2011
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9260-2

Weitere Artikel der Ausgabe 1/2011

Journal of Digital Imaging 1/2011 Zur Ausgabe

Update Radiologie