Skip to main content
main-content

19.12.2018 | Original Research | Ausgabe 5/2019

Journal of Clinical Monitoring and Computing 5/2019

Anesthesia depth monitoring using alternative placement of entropy sensors: a prospective study

Zeitschrift:
Journal of Clinical Monitoring and Computing > Ausgabe 5/2019
Autoren:
David I. Vachnadze, Boris A. Akselrod, Denis A. Guskov, Alevtina V. Goncharova

Abstract

Spectral entropy is based on analysis of variations in electroencephalography and frontal electromyography, and is a safe and reliable method for anesthesia depth monitoring. However, standard frontal positioning of entropy electrodes in patients undergoing cardiac surgery is sometimes challenging. The present study aimed to compare standard entropy sensor placement with an alternative (infraorbital) site. This prospective study included 20 patients who underwent cardiovascular surgery at the authors’ center. Monitoring was performed with standard and alternative entropy electrode positions from patient admission to surgery to transfer to the intensive care unit. Data were recorded every 15 s; all data were analyzed and compared using Bland–Altman, scatter plot with Pearson correlation coefficient, and sensitivity/specificity analyses. Overall, 20,784 pairs of response entropy (RE) and state entropy (SE) indexes were collected. Bland–Altman analysis revealed a mean difference in RE of 0.37 (95% LOA − 7.09, 7.88) and SE 0.69 (95% LOA − 5.95, 7.31); with 3.46% (720/20,784) RE and 3.40% (706/10,790) SE values lying outside of the limits of agreement. Correlation analysis revealed strong positive correlation in both cases: RE, r = 0.983, p < 0.05; SE, r = 0.984; p < 0.05. Sensitivity/specificity analysis revealed 98.1% sensitivity, 93.3% specificity and 97.1% test efficiency for RE, and 99.2%, 95.1% and 98.5% for SE, respectively. Infraorbital entropy sensor placement in patients undergoing cardiovascular surgery is reliable and effective. The strong positive correlation between the two methods of registration enables alternative entropy measurement when frontal placement is not possible.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt e.Med zum Sonderpreis bestellen!

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 5/2019

Journal of Clinical Monitoring and Computing 5/2019 Zur Ausgabe

Neu im Fachgebiet AINS

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update AINS und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise