Skip to main content
Erschienen in: International Ophthalmology 8/2020

20.04.2020 | Original Paper

Anterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantation

verfasst von: José-María Sánchez-González, Federico Alonso-Aliste, Gracia Perea-Peña, Rahul Rachwani-Anil, Rafael Márquez-de-Aracena-del-Cid, Carlos Rocha-de-Lossada

Erschienen in: International Ophthalmology | Ausgabe 8/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate 1-year changes of vault, anterior chamber angle width (ACAW) and intraocular pressure (IOP) after the implantation of implantable collamer lens (ICL) V4c in high myopic patients.

Methods

Sixty ICL V4c implantation surgeries were included. Patients underwent surgery between January 2014 and June 2017 at Ophthalmology Center Tecnolaser Clinic Vision®, Seville, Spain. All patients had a 12-month follow-up. A preoperative spherical equivalent between − 4.00 and − 15.00 D was established as inclusion criterion. ACAW and vault were measured with Pentacam single rotation Scheimpflug camera (Oculus Optikgeräte GmbH, Wetzlar, Germany). IOP was measured with CORVIS ST (Oculus Optikgeräte GmbH, Wetzlar, Germany).

Results

One-day vault was 553.17 ± 169.80 [268–975] µm; 12-month vault was 515.67 ± 176.46 [169–950] µm (p < 0.01). Preoperative ACAW was 36.85° ± 4.60° [26.7°–46.8°]; postoperative ACAW was 25.98° ± 3.85° [16.4°–32.6°] (p < 0.01). Preoperative IOP was 15.37 ± 1.58 [12.0–18.3] mmHg, postoperative IOP was 15.61 ± 1.60 [12.0–19.0] mm Hg (p = 0.35).

Conclusions

ICL V4c lens experienced a progressive reduction of vault after 12-month follow-up. ACAW decrease was significant between preoperative and postoperative values. We propose to include a minimum preoperative ACAW and an IOP correction factor for lens size.
Literatur
15.
Zurück zum Zitat Chung T-Y, Park SC, Lee MO et al (2009) Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years. J Refract Surg 25:251–258CrossRef Chung T-Y, Park SC, Lee MO et al (2009) Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years. J Refract Surg 25:251–258CrossRef
Metadaten
Titel
Anterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantation
verfasst von
José-María Sánchez-González
Federico Alonso-Aliste
Gracia Perea-Peña
Rahul Rachwani-Anil
Rafael Márquez-de-Aracena-del-Cid
Carlos Rocha-de-Lossada
Publikationsdatum
20.04.2020
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 8/2020
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-020-01381-w

Weitere Artikel der Ausgabe 8/2020

International Ophthalmology 8/2020 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.