Skip to main content
Erschienen in: Surgical and Radiologic Anatomy 2/2017

11.05.2016 | Original Article

Anterior loop of the mental nerve, mental foramen and incisive nerve emergency: tridimensional assessment and surgical applications

verfasst von: Juan Carlos Prados-Frutos, Carmen Salinas-Goodier, Ángel Manchón, Rosa Rojo

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim of this study was to investigate the prevalence and length of the anterior loop (AL), the distance from this landmark to the alveolar crest and its relation with the shape of the foramen and emergency pattern in the Spanish population on helical computed tomography scan (helical CT scan) through tridimensional reconstructions.

Methods

Helical CT scan images of 41 patients aged 65 or older were analyzed. A total of 82 human hemi-mandibles were examined in this study. A tridimensional reconstruction of each mandible and Inferior Alveolar Nerve canal was created in AMIRA® software (AMIRA, Mercury Computer Systems, Berlin, Germany). Prevalence, length and distance between the AL, mental foramen and alveolar ridge were measured. This retrospective observational study was performed according to the STROBE guidelines.

Results

Prevalence of the AL was 53.7 % (n = 44) and the mean length was 1.3 ± 0.64 mm. The mean distance from the highest point of the loop to the alveolar ridge was 13.4 ± 2.8 mm. The mean diameter of the mental foramen was 3.5 ± 0.65 mm and the proportion of the oval-shaped was 62.2 % (n = 51) and round-shaped was 37.8 % (n = 31). The study found that patients with type 1 pattern emergency pattern had a higher prevalence of the AL (p = 0.03).

Conclusions

Prevalence, location and length of the anterior loop can be overlooked if only two-dimensional pre-surgical studies are performed. Therefore, three-dimensional imaging and modeling of anatomic structures should be used for the pre-operative examination of the interforaminal area. Given the wide variability of the emergency pattern of the mental nerve and the prevalence and location of the anterior loop, it should be studied in every patient individually.
Literatur
1.
Zurück zum Zitat Alonso MB, Cortes AR, Camargo AJ, Arita ES, Haiter-Neto F, Watanabe PC (2011) Assessment of panoramic radiomorphometric indices of the mandible in a Brazilian population. ISRN Rheumatol 854287 Alonso MB, Cortes AR, Camargo AJ, Arita ES, Haiter-Neto F, Watanabe PC (2011) Assessment of panoramic radiomorphometric indices of the mandible in a Brazilian population. ISRN Rheumatol 854287
2.
Zurück zum Zitat Angelopoulos C, Thomas SL, Hechler S, Parissis N, Hlavacek M (2008) Comparison between digital panoramic radiography and cone-beam computed tomography for the identification of the mandibular canal as part of presurgical dental implant assessment. J Oral Maxillofac Surg 66:2130–2135CrossRefPubMed Angelopoulos C, Thomas SL, Hechler S, Parissis N, Hlavacek M (2008) Comparison between digital panoramic radiography and cone-beam computed tomography for the identification of the mandibular canal as part of presurgical dental implant assessment. J Oral Maxillofac Surg 66:2130–2135CrossRefPubMed
3.
Zurück zum Zitat Apostolakis D, Brown JE (2012) The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and recommendation for interforaminal implant installation based on cone beam CT imaging. Clin Oral Implants Res 23:1022–1030CrossRefPubMed Apostolakis D, Brown JE (2012) The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and recommendation for interforaminal implant installation based on cone beam CT imaging. Clin Oral Implants Res 23:1022–1030CrossRefPubMed
4.
Zurück zum Zitat Bavitz JB, Harn SD, Hansen CA, Lang M (1993) An anatomical study of mental neurovascular bundle-implant relationships. Int J Oral Maxillofac Implants 8:563–567PubMed Bavitz JB, Harn SD, Hansen CA, Lang M (1993) An anatomical study of mental neurovascular bundle-implant relationships. Int J Oral Maxillofac Implants 8:563–567PubMed
5.
Zurück zum Zitat Benninger B, Miller D, Maharathi A, Carter W (2011) Dental implant placement investigation: is the anterior loop of the mental nerve clinically relevant? J Oral Maxillofac Surg 69:182–185CrossRefPubMed Benninger B, Miller D, Maharathi A, Carter W (2011) Dental implant placement investigation: is the anterior loop of the mental nerve clinically relevant? J Oral Maxillofac Surg 69:182–185CrossRefPubMed
6.
Zurück zum Zitat Chen JC, Lin LM, Geist JR, Chen JY, Chen CH, Chen YK (2013) A retrospective comparison of the location and diameter of the inferior alveolar canal at the mental foramen and length of the anterior loop between American and Taiwanese cohorts using CBCT. Surg Radiol Anat 35:11–18CrossRefPubMed Chen JC, Lin LM, Geist JR, Chen JY, Chen CH, Chen YK (2013) A retrospective comparison of the location and diameter of the inferior alveolar canal at the mental foramen and length of the anterior loop between American and Taiwanese cohorts using CBCT. Surg Radiol Anat 35:11–18CrossRefPubMed
7.
Zurück zum Zitat de Oliveira-Santos C, Souza PH, de Azambuja Berti-Couto S, Stinkens L, Moyaert K, Rubira-Bullen IR et al (2012) Assessment of variations of the mandibular canal through cone beam computed tomography. Clin Oral Investig 16:387–393CrossRefPubMed de Oliveira-Santos C, Souza PH, de Azambuja Berti-Couto S, Stinkens L, Moyaert K, Rubira-Bullen IR et al (2012) Assessment of variations of the mandibular canal through cone beam computed tomography. Clin Oral Investig 16:387–393CrossRefPubMed
8.
Zurück zum Zitat Deeb GR, Dierks E, So YT (2009) Sensory nerve conduction study of the mental nerve. Muscle Nerve 23:1121–1124CrossRef Deeb GR, Dierks E, So YT (2009) Sensory nerve conduction study of the mental nerve. Muscle Nerve 23:1121–1124CrossRef
9.
Zurück zum Zitat Filo K, Schneider T, Locher MC, Kruse AL, Lübbers HT (2014) The inferior alveolar nerve’s loop at the mental foramen and its implications for surgery. J Am Dent Assoc 145:260–269CrossRefPubMed Filo K, Schneider T, Locher MC, Kruse AL, Lübbers HT (2014) The inferior alveolar nerve’s loop at the mental foramen and its implications for surgery. J Am Dent Assoc 145:260–269CrossRefPubMed
10.
Zurück zum Zitat Greenstein G, Tarnow D (2006) The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review. J Periodontol 77:1933–1943CrossRefPubMed Greenstein G, Tarnow D (2006) The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review. J Periodontol 77:1933–1943CrossRefPubMed
11.
Zurück zum Zitat Hu KS, Yun HS, Hur MS, Kwon HJ, Abe S, Kim HJ (2007) Branching patterns and intraosseous course of the mental nerve. J Oral Maxillofac Surg 65:2288–2294CrossRefPubMed Hu KS, Yun HS, Hur MS, Kwon HJ, Abe S, Kim HJ (2007) Branching patterns and intraosseous course of the mental nerve. J Oral Maxillofac Surg 65:2288–2294CrossRefPubMed
12.
Zurück zum Zitat Jacobs R, Mraiwa N, Van Steenberghe D, Sanderink G, Quirynen M (2004) Appearance of the mandibular incisive canal on panoramic radiographs. Surg Radiol Anat 26:329–333CrossRefPubMed Jacobs R, Mraiwa N, Van Steenberghe D, Sanderink G, Quirynen M (2004) Appearance of the mandibular incisive canal on panoramic radiographs. Surg Radiol Anat 26:329–333CrossRefPubMed
13.
Zurück zum Zitat Kaya Y, Sencimen M, Sahin S, Okcu KM, Dogan N, Bahcecitapar M (2008) Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography. Int J Oral Maxillofac Implants 23:919–925PubMed Kaya Y, Sencimen M, Sahin S, Okcu KM, Dogan N, Bahcecitapar M (2008) Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography. Int J Oral Maxillofac Implants 23:919–925PubMed
14.
Zurück zum Zitat Khan I, Halli R, Gadre P, Gadre KS (2011) Correlation of panoramic radiographs and spiral CT scan in the preoperative assessment of intimacy of the inferior alveolar canal to impacted mandibular third molars. J Craniofac Surg 22:566–570CrossRefPubMed Khan I, Halli R, Gadre P, Gadre KS (2011) Correlation of panoramic radiographs and spiral CT scan in the preoperative assessment of intimacy of the inferior alveolar canal to impacted mandibular third molars. J Craniofac Surg 22:566–570CrossRefPubMed
15.
Zurück zum Zitat Kieser J, Kuzmanovic D, Payne A, Dennison J, Herbison P (2002) Patterns of emergence of the human mental nerve. Arch Oral Biol 47:743–747CrossRefPubMed Kieser J, Kuzmanovic D, Payne A, Dennison J, Herbison P (2002) Patterns of emergence of the human mental nerve. Arch Oral Biol 47:743–747CrossRefPubMed
16.
Zurück zum Zitat Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res 14:464–471CrossRefPubMed Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res 14:464–471CrossRefPubMed
17.
Zurück zum Zitat Lekholm U, Zarb GA. In: Patient selection and preparation. Tissue integrated prostheses: osseointegration in clinical dentistry. Branemark PI, Zarb GA, Albrektsson T, editor. Chicago: Quintessence Publishing Company y 199–209. pp 199–209 Lekholm U, Zarb GA. In: Patient selection and preparation. Tissue integrated prostheses: osseointegration in clinical dentistry. Branemark PI, Zarb GA, Albrektsson T, editor. Chicago: Quintessence Publishing Company y 199–209. pp 199–209
18.
Zurück zum Zitat Li X, Jin ZK, Zhao H, Yang K, Duan JM, Wang WJ (2013) The prevalence, length and position of the anterior loop of the inferior alveolar nerve in Chinese, assessed by spiral computed tomography. Surg Radiol Anat 35:823–830CrossRefPubMed Li X, Jin ZK, Zhao H, Yang K, Duan JM, Wang WJ (2013) The prevalence, length and position of the anterior loop of the inferior alveolar nerve in Chinese, assessed by spiral computed tomography. Surg Radiol Anat 35:823–830CrossRefPubMed
19.
Zurück zum Zitat Lu CI, Won J, Al-Ardah A, Santana R, Rice D, Lozada J (2015) Assessment of the anterior loop of the mental nerve using cone beam CT-scan. J Oral Implantol 41:632–639CrossRefPubMed Lu CI, Won J, Al-Ardah A, Santana R, Rice D, Lozada J (2015) Assessment of the anterior loop of the mental nerve using cone beam CT-scan. J Oral Implantol 41:632–639CrossRefPubMed
20.
Zurück zum Zitat Neiva RF, Gapski R, Wang HL (2004) Morphometric analysis of implant-related anatomy in Caucasian skulls. J Periodontol 75:1061–1067CrossRefPubMed Neiva RF, Gapski R, Wang HL (2004) Morphometric analysis of implant-related anatomy in Caucasian skulls. J Periodontol 75:1061–1067CrossRefPubMed
21.
Zurück zum Zitat Ngeow WC, Dionysius DD, Ishak H, Nambiar P (2009) A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups. J Oral Sci 51:231–237CrossRefPubMed Ngeow WC, Dionysius DD, Ishak H, Nambiar P (2009) A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups. J Oral Sci 51:231–237CrossRefPubMed
22.
Zurück zum Zitat Parnia F, Moslehifard E, Hafezeqoran A, Mahboub F, Mojaver-Kahnamoui H (2012) Characteristics of anatomical landmarks in the mandibular interforaminal region: a cone-beam computed tomography study. Med Oral Patol Oral Cir Bucal 17:420–425CrossRef Parnia F, Moslehifard E, Hafezeqoran A, Mahboub F, Mojaver-Kahnamoui H (2012) Characteristics of anatomical landmarks in the mandibular interforaminal region: a cone-beam computed tomography study. Med Oral Patol Oral Cir Bucal 17:420–425CrossRef
23.
Zurück zum Zitat Rosa MB, Sotto-Maior BS, de Machado V, Francischone CE (2013) Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography. Int J Oral Maxillofac Implants 28:388–392CrossRefPubMed Rosa MB, Sotto-Maior BS, de Machado V, Francischone CE (2013) Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography. Int J Oral Maxillofac Implants 28:388–392CrossRefPubMed
24.
Zurück zum Zitat Sahman H, Sekerci AE, Sisman Y, Payveren M (2014) Assessment of the visibility and characteristics of the mandibular incisive canal: cone beam computed tomography versus panoramic radiography. Int J Oral Maxillofac Implants 29:71–78CrossRefPubMed Sahman H, Sekerci AE, Sisman Y, Payveren M (2014) Assessment of the visibility and characteristics of the mandibular incisive canal: cone beam computed tomography versus panoramic radiography. Int J Oral Maxillofac Implants 29:71–78CrossRefPubMed
25.
Zurück zum Zitat Sankar DK, Bhanu SP, Susan PJ (2011) Morphometrical and morphological study of mental foramen in dry dentulous mandibles of South Andhra population of India. Indian J Dent Res 22:542–546CrossRefPubMed Sankar DK, Bhanu SP, Susan PJ (2011) Morphometrical and morphological study of mental foramen in dry dentulous mandibles of South Andhra population of India. Indian J Dent Res 22:542–546CrossRefPubMed
26.
Zurück zum Zitat Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H et al (2009) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg 67:744–750CrossRefPubMed Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H et al (2009) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg 67:744–750CrossRefPubMed
27.
Zurück zum Zitat von Arx T, Häfliger J, Chappuis V (2005) Neurosensory disturbances following bone harvesting in the symphysis: a prospective clinical study. Clin Oral Implants Res 16:432–439CrossRef von Arx T, Häfliger J, Chappuis V (2005) Neurosensory disturbances following bone harvesting in the symphysis: a prospective clinical study. Clin Oral Implants Res 16:432–439CrossRef
28.
Zurück zum Zitat von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP, y Initiative., STROBE (2008) The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE)statement: guidelines for reporting observational studies. J Clin Epidemiol 61(4):344–349CrossRef von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP, y Initiative., STROBE (2008) The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE)statement: guidelines for reporting observational studies. J Clin Epidemiol 61(4):344–349CrossRef
29.
Zurück zum Zitat Vujanovic-Eskenazi A, Valero-James JM, Sánchez-Garcés MA, Gay-Escoda C (2015) A retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and cone beam computerized tomography. Med Oral Patol Oral Cir Bucal 20:239–245CrossRef Vujanovic-Eskenazi A, Valero-James JM, Sánchez-Garcés MA, Gay-Escoda C (2015) A retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and cone beam computerized tomography. Med Oral Patol Oral Cir Bucal 20:239–245CrossRef
30.
Zurück zum Zitat Watanabe H, Mohammad Abdul M, Kurabayashi T, Aoki H (2010) Mandible size and morphology determined wit. CT on a premise of dental implant operation. Surg Radiol Anat 32:343–349CrossRefPubMed Watanabe H, Mohammad Abdul M, Kurabayashi T, Aoki H (2010) Mandible size and morphology determined wit. CT on a premise of dental implant operation. Surg Radiol Anat 32:343–349CrossRefPubMed
Metadaten
Titel
Anterior loop of the mental nerve, mental foramen and incisive nerve emergency: tridimensional assessment and surgical applications
verfasst von
Juan Carlos Prados-Frutos
Carmen Salinas-Goodier
Ángel Manchón
Rosa Rojo
Publikationsdatum
11.05.2016
Verlag
Springer Paris
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 2/2017
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-016-1690-1

Weitere Artikel der Ausgabe 2/2017

Surgical and Radiologic Anatomy 2/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.