Abstract

Cardiac implantable electronic device (CIED) infections are associated with significant morbidity in the pediatric device population, with a tenfold higher risk of infection in children compared to adults. The 2010 American Heart Association (AHA) guidelines recommend a single dose of systemic antibiotic (ABX) prophylaxis prior to CIED implantation and no post-operative (OP) ABX. However, there is limited data regarding adherence to this recommendation among the pediatric community. To assess current clinical practices for CIED ABX prophylaxis in pediatrics; whether the AHA guidelines are being followed; and if not, the reasons for non-adherence. An anonymous web-based survey was sent to physician members of the Pediatric And Congenital Electrophysiology Society regarding ABX prophylaxis for new CIED implants and reoperations. 75 (25%) members responded. Only 7% of respondents follow the 2010 AHA guidelines. While all respondents give pre-OP IV ABX, 64% routinely treat patients with 24-h post-OP IV ABX with additional oral or IV therapy. 69% of respondents are cognizant of the guidelines but 88% of those cognizant do not follow the guidelines for a variety of reasons including lack of data and different substrate (pediatric patients). 79% stated that pediatric-specific data would be required for them to change their practice and follow the published guidelines. The majority of pediatric EP physicians who responded to this survey do not follow the current AHA guidelines on ABX prophylaxis and administer post-OP ABX. Most pediatric EP physicians believe that the increased risk of infection in children merits additional ABX.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Zhan C, Baine WB, Sedrakyan A, Steiner C (2008) Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis. J Gen Intern Med 23:13–19CrossRefPubMed Zhan C, Baine WB, Sedrakyan A, Steiner C (2008) Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis. J Gen Intern Med 23:13–19CrossRefPubMed
2.
Zurück zum Zitat Burns KM, Evans F, Kaltman JR (2011) Pediatric ICD utilization in the United States from 1997 to 2006. Heart Rhythm 8:23–28CrossRefPubMed Burns KM, Evans F, Kaltman JR (2011) Pediatric ICD utilization in the United States from 1997 to 2006. Heart Rhythm 8:23–28CrossRefPubMed
3.
Zurück zum Zitat Mirowski M, Reid PR, Mower MM et al (1980) Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med 303:322–324CrossRefPubMed Mirowski M, Reid PR, Mower MM et al (1980) Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med 303:322–324CrossRefPubMed
4.
Zurück zum Zitat Moss AJ, Liu JE, Gottlieb S, Locati EH, Schwartz PJ, Robinson JL (1991) Efficacy of permanent pacing in the management of high-risk patients with long QT syndrome. Circulation 84:1524–1529CrossRefPubMed Moss AJ, Liu JE, Gottlieb S, Locati EH, Schwartz PJ, Robinson JL (1991) Efficacy of permanent pacing in the management of high-risk patients with long QT syndrome. Circulation 84:1524–1529CrossRefPubMed
5.
Zurück zum Zitat Bardy GH, Lee KL, Mark DB et al (2005) Amiodarone or an implantable cardioverter–defibrillator for congestive heart failure. N Engl J Med 352:225–237CrossRefPubMed Bardy GH, Lee KL, Mark DB et al (2005) Amiodarone or an implantable cardioverter–defibrillator for congestive heart failure. N Engl J Med 352:225–237CrossRefPubMed
6.
Zurück zum Zitat Brignole M, Menozzi C, Moya A et al (2012) Pacemaker therapy in patients with neurally mediated syncope and documented asystole: Third International Study on Syncope of Uncertain Etiology (ISSUE-3): a randomized trial. Circulation 125:2566–2571CrossRefPubMed Brignole M, Menozzi C, Moya A et al (2012) Pacemaker therapy in patients with neurally mediated syncope and documented asystole: Third International Study on Syncope of Uncertain Etiology (ISSUE-3): a randomized trial. Circulation 125:2566–2571CrossRefPubMed
7.
Zurück zum Zitat Silka MJ, Kron J, Dunnigan A, Dick M (1993) Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. Pediatr Electrophysiol Soc Circ 87:800–807 Silka MJ, Kron J, Dunnigan A, Dick M (1993) Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. Pediatr Electrophysiol Soc Circ 87:800–807
8.
Zurück zum Zitat Voigt A, Shalaby A, Saba S (2006) Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coll Cardiol 48:590–591CrossRefPubMed Voigt A, Shalaby A, Saba S (2006) Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coll Cardiol 48:590–591CrossRefPubMed
9.
Zurück zum Zitat Voigt A, Shalaby A, Saba S (2010) Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights. Pacing Clin Electrophysiol 33:414–419CrossRefPubMed Voigt A, Shalaby A, Saba S (2010) Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights. Pacing Clin Electrophysiol 33:414–419CrossRefPubMed
10.
Zurück zum Zitat Greenspon AJ, Patel JD, Lau E et al (2011) 16-Year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States: 1993 to 2008. J Am Coll Cardiol 58:1001–1006CrossRefPubMed Greenspon AJ, Patel JD, Lau E et al (2011) 16-Year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States: 1993 to 2008. J Am Coll Cardiol 58:1001–1006CrossRefPubMed
11.
Zurück zum Zitat Link MS, Hill SL, Cliff DL et al (1999) Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults. Am J Cardiol 83:263–266CrossRefPubMed Link MS, Hill SL, Cliff DL et al (1999) Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults. Am J Cardiol 83:263–266CrossRefPubMed
12.
Zurück zum Zitat Baddour LM, Epstein AE, Erickson CC et al (2010) Update on cardiovascular implantable electronic device infections and their management. Circulation 121:458–477CrossRefPubMed Baddour LM, Epstein AE, Erickson CC et al (2010) Update on cardiovascular implantable electronic device infections and their management. Circulation 121:458–477CrossRefPubMed
13.
Zurück zum Zitat de Oliveira JC, Martinelli M, Nishioka SADO et al (2009) Efficacy of antibiotic prophylaxis before the implantation of pacemakers and cardioverter-defibrillators. Results of a large, prospective, randomized, double-blinded, placebo-controlled trial. Circulation 2:29–34PubMed de Oliveira JC, Martinelli M, Nishioka SADO et al (2009) Efficacy of antibiotic prophylaxis before the implantation of pacemakers and cardioverter-defibrillators. Results of a large, prospective, randomized, double-blinded, placebo-controlled trial. Circulation 2:29–34PubMed
14.
Zurück zum Zitat Klug D, Vaksmann GUY, JarwÉ M et al (2003) Pacemaker lead infection in young patients. Pacing Clin Electrophysiol 26:1489–1493CrossRefPubMed Klug D, Vaksmann GUY, JarwÉ M et al (2003) Pacemaker lead infection in young patients. Pacing Clin Electrophysiol 26:1489–1493CrossRefPubMed
15.
Zurück zum Zitat Berul CI, Van Hare GF, Kertesz NJ et al (2008) Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients. J Am Coll Cardiol 51:1685–1691CrossRefPubMed Berul CI, Van Hare GF, Kertesz NJ et al (2008) Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients. J Am Coll Cardiol 51:1685–1691CrossRefPubMed
16.
Zurück zum Zitat Basil A, Lubitz SA, Noseworthy PA et al (2017) Periprocedural antibiotic prophylaxis for cardiac implantable electrical device procedures: results from a Heart Rhythm Society Survey. JACC Clin Electrophysiol 3:632–634CrossRefPubMedPubMedCentral Basil A, Lubitz SA, Noseworthy PA et al (2017) Periprocedural antibiotic prophylaxis for cardiac implantable electrical device procedures: results from a Heart Rhythm Society Survey. JACC Clin Electrophysiol 3:632–634CrossRefPubMedPubMedCentral
Metadaten
Titel
Antibiotic Prophylaxis Practices in Pediatric Cardiac Implantable Electronic Device Procedures: A Survey of the Pediatric And Congenital Electrophysiology Society (PACES)
verfasst von
Spenser Y. Chen
Scott R. Ceresnak
Kara S. Motonaga
Anthony Trela
Debra Hanisch
Anne M. Dubin
Publikationsdatum
22.03.2018
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 6/2018
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-018-1865-0

Weitere Artikel der Ausgabe 6/2018

Pediatric Cardiology 6/2018 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.