Aortic annulus sizing in stenotic bicommissural non-raphe-type bicuspid aortic valves: reconstructing a three-dimensional structure using only two hinge points

verfasst von: Antonio H. Frangieh, Jonathan Michel, Oliver Deutsch, Michael Joner, Costanza Pellegrini, Tobias Rheude, Sabine Bleiziffer, Albert Markus Kasel

Erschienen in: Clinical Research in Cardiology | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

Bicuspid aortic valve (BAV) anatomy is becoming an increasingly frequently encountered challenge in transcatheter aortic valve implantation (TAVI). Bicommissural non-raphe-type BAV (Sievers and Schmidtke Type 0) is composed morphologically of two aortic cusps with no raphe and is less common than the tricommissural or bicommissural raphe-type configurations. Precise annular sizing is a key step for successful TAVI in BAV. The challenge in bicommissural non-raphe-type BAV is that a three-dimensional structure has to be reconstructed using only two anatomical hinge points. For this reason, available software are limited when it comes to bicommissural non-raphe-type BAV. We propose that manual assessment of the aortic root in bicommissural non-raphe-type BAV using multi-planar reconstruction (MPR) software can be performed successfully by aligning the two available hinge points and measuring the smallest identifiable annular dimensions in the transverse plane (Fig. 1). We identified 12 patients with bicommissural non-raphe-type BAV undergoing TAVI between January 2013 and December 2017 in our high-volume institution. Our novel sizing strategy was employed prospectively in three patients—with good clinical outcomes—and evaluated retrospectively in the remainder (Table 1). No patient suffered a central major vascular complication or required new permanent pacemaker implantation. Device success occurred in all patients except one (post-procedural echocardiographic transvalvular gradient of 23 mmHg). In the retrospectively assessed cases, the novel annulus measure was concordant with the implanted THV size in 7 out of 9 procedures and, importantly, did not overestimate the annulus dimensions in any case. Furthermore, in two balloon-expandable THV cases the new measure may, in retrospect, have prompted consideration of a smaller implant size. To be noted, balloon sizing of the aortic annulus has additional value when selecting the valve size in BAV anatomy. Further prospective validation of this novel MDCT sizing technique is required.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Hoffman JI, Kaplan S (2002) The incidence of congenital heart disease. J Am Coll Cardiol 39(12):1890–1900CrossRef Hoffman JI, Kaplan S (2002) The incidence of congenital heart disease. J Am Coll Cardiol 39(12):1890–1900CrossRef
2.
Zurück zum Zitat Roberts WC, Ko JM (2005) Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation. Circulation 111(7):920–925CrossRef Roberts WC, Ko JM (2005) Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation. Circulation 111(7):920–925CrossRef
3.
Zurück zum Zitat Popma JJ, Ramadan R (2016) CT imaging of bicuspid aortic valve disease for TAVR. JACC Cardiovasc Imaging 9(10):1159–1163CrossRef Popma JJ, Ramadan R (2016) CT imaging of bicuspid aortic valve disease for TAVR. JACC Cardiovasc Imaging 9(10):1159–1163CrossRef
4.
Zurück zum Zitat Sievers HH, Schmidtke C (2007) A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg 133(5):1226–1233CrossRef Sievers HH, Schmidtke C (2007) A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg 133(5):1226–1233CrossRef
5.
Zurück zum Zitat Jilaihawi H, Chen M, Webb J, Himbert D, Ruiz CE, Rodes-Cabau J et al (2016) A bicuspid aortic valve imaging classification for the TAVR era. JACC Cardiovasc Imaging 9(10):1145–1158CrossRef Jilaihawi H, Chen M, Webb J, Himbert D, Ruiz CE, Rodes-Cabau J et al (2016) A bicuspid aortic valve imaging classification for the TAVR era. JACC Cardiovasc Imaging 9(10):1145–1158CrossRef
6.
Zurück zum Zitat Himbert D, Pontnau F, Messika-Zeitoun D, Descoutures F, Detaint D, Cueff C et al (2012) Feasibility and outcomes of transcatheter aortic valve implantation in high-risk patients with stenotic bicuspid aortic valves. Am J Cardiol 110(6):877–883CrossRef Himbert D, Pontnau F, Messika-Zeitoun D, Descoutures F, Detaint D, Cueff C et al (2012) Feasibility and outcomes of transcatheter aortic valve implantation in high-risk patients with stenotic bicuspid aortic valves. Am J Cardiol 110(6):877–883CrossRef
7.
Zurück zum Zitat Siu SC, Silversides CK (2010) Bicuspid aortic valve disease. J Am Coll Cardiol 55(25):2789–2800CrossRef Siu SC, Silversides CK (2010) Bicuspid aortic valve disease. J Am Coll Cardiol 55(25):2789–2800CrossRef
8.
Zurück zum Zitat Zhao ZG, Jilaihawi H, Feng Y, Chen M (2015) Transcatheter aortic valve implantation in bicuspid anatomy. Nat Rev Cardiol 12(2):123–128CrossRef Zhao ZG, Jilaihawi H, Feng Y, Chen M (2015) Transcatheter aortic valve implantation in bicuspid anatomy. Nat Rev Cardiol 12(2):123–128CrossRef
9.
Zurück zum Zitat Ng ACT, Wang WYS, Delgado V, Bax JJ (2017) Bicuspid aortic valve disease: new insights. Struct Heart 1(1–2):9–17CrossRef Ng ACT, Wang WYS, Delgado V, Bax JJ (2017) Bicuspid aortic valve disease: new insights. Struct Heart 1(1–2):9–17CrossRef
10.
Zurück zum Zitat Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363(17):1597–1607CrossRef Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363(17):1597–1607CrossRef
11.
Zurück zum Zitat Adams DH, Popma JJ, Reardon MJ (2014) Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med 371(10):967–968CrossRef Adams DH, Popma JJ, Reardon MJ (2014) Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med 371(10):967–968CrossRef
12.
Zurück zum Zitat Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK et al (2016) Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med 374(17):1609–1620CrossRef Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK et al (2016) Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med 374(17):1609–1620CrossRef
13.
Zurück zum Zitat Kochman J, Huczek Z, Scislo P, Dabrowski M, Chmielak Z, Szymanski P et al (2014) Comparison of one- and 12-month outcomes of transcatheter aortic valve replacement in patients with severely stenotic bicuspid versus tricuspid aortic valves (results from a multicenter registry). Am J Cardiol 114(5):757–762CrossRef Kochman J, Huczek Z, Scislo P, Dabrowski M, Chmielak Z, Szymanski P et al (2014) Comparison of one- and 12-month outcomes of transcatheter aortic valve replacement in patients with severely stenotic bicuspid versus tricuspid aortic valves (results from a multicenter registry). Am J Cardiol 114(5):757–762CrossRef
14.
Zurück zum Zitat Mylotte D, Lefevre T, Sondergaard L, Watanabe Y, Modine T, Dvir D et al (2014) Transcatheter aortic valve replacement in bicuspid aortic valve disease. J Am Coll Cardiol 64(22):2330–2339CrossRef Mylotte D, Lefevre T, Sondergaard L, Watanabe Y, Modine T, Dvir D et al (2014) Transcatheter aortic valve replacement in bicuspid aortic valve disease. J Am Coll Cardiol 64(22):2330–2339CrossRef
15.
Zurück zum Zitat Bauer T, Linke A, Sievert H, Kahlert P, Hambrecht R, Nickenig G et al (2014) Comparison of the effectiveness of transcatheter aortic valve implantation in patients with stenotic bicuspid versus tricuspid aortic valves (from the German TAVI Registry). Am J Cardiol 113(3):518–521CrossRef Bauer T, Linke A, Sievert H, Kahlert P, Hambrecht R, Nickenig G et al (2014) Comparison of the effectiveness of transcatheter aortic valve implantation in patients with stenotic bicuspid versus tricuspid aortic valves (from the German TAVI Registry). Am J Cardiol 113(3):518–521CrossRef
16.
Zurück zum Zitat Yousef A, Simard T, Webb J, Rodes-Cabau J, Costopoulos C, Kochman J et al (2015) Transcatheter aortic valve implantation in patients with bicuspid aortic valve: a patient level multi-center analysis. Int J Cardiol 189:282–288CrossRef Yousef A, Simard T, Webb J, Rodes-Cabau J, Costopoulos C, Kochman J et al (2015) Transcatheter aortic valve implantation in patients with bicuspid aortic valve: a patient level multi-center analysis. Int J Cardiol 189:282–288CrossRef
17.
Zurück zum Zitat Xie X, Shi X, Xun X, Rao L (2016) Efficacy and safety of transcatheter aortic valve implantation for bicuspid aortic valves: a systematic review and meta-analysis. Ann Thorac Cardiovasc Surg 22(4):203–215CrossRef Xie X, Shi X, Xun X, Rao L (2016) Efficacy and safety of transcatheter aortic valve implantation for bicuspid aortic valves: a systematic review and meta-analysis. Ann Thorac Cardiovasc Surg 22(4):203–215CrossRef
18.
Zurück zum Zitat Yoon SH, Lefevre T, Ahn JM, Perlman GY, Dvir D, Latib A et al (2016) Transcatheter aortic valve replacement with early- and new-generation devices in bicuspid aortic valve stenosis. J Am Coll Cardiol 68(11):1195–1205CrossRef Yoon SH, Lefevre T, Ahn JM, Perlman GY, Dvir D, Latib A et al (2016) Transcatheter aortic valve replacement with early- and new-generation devices in bicuspid aortic valve stenosis. J Am Coll Cardiol 68(11):1195–1205CrossRef
19.
Zurück zum Zitat Phan K, Wong S, Phan S, Ha H, Qian P, Yan TD (2015) Transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valve stenosis—systematic review and meta-analysis. Heart Lung Circ 24(7):649–659CrossRef Phan K, Wong S, Phan S, Ha H, Qian P, Yan TD (2015) Transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valve stenosis—systematic review and meta-analysis. Heart Lung Circ 24(7):649–659CrossRef
20.
Zurück zum Zitat Yoon SH, Bleiziffer S, De Backer O, Delgado V, Arai T, Ziegelmueller J et al (2017) Outcomes in transcatheter aortic valve replacement for bicuspid versus tricuspid aortic valve stenosis. J Am Coll Cardiol 69(21):2579–2589CrossRef Yoon SH, Bleiziffer S, De Backer O, Delgado V, Arai T, Ziegelmueller J et al (2017) Outcomes in transcatheter aortic valve replacement for bicuspid versus tricuspid aortic valve stenosis. J Am Coll Cardiol 69(21):2579–2589CrossRef
21.
Zurück zum Zitat Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Sondergaard L, Mumtaz M et al (2017) Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med 376(14):1321–1331CrossRef Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Sondergaard L, Mumtaz M et al (2017) Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med 376(14):1321–1331CrossRef
22.
Zurück zum Zitat Thyregod HG, Steinbruchel DA, Ihlemann N, Nissen H, Kjeldsen BJ, Petursson P et al (2015) Transcatheter versus surgical aortic valve replacement in patients with severe aortic valve stenosis: 1-year results from the all-comers NOTION randomized clinical trial. J Am Coll Cardiol 65(20):2184–2194CrossRef Thyregod HG, Steinbruchel DA, Ihlemann N, Nissen H, Kjeldsen BJ, Petursson P et al (2015) Transcatheter versus surgical aortic valve replacement in patients with severe aortic valve stenosis: 1-year results from the all-comers NOTION randomized clinical trial. J Am Coll Cardiol 65(20):2184–2194CrossRef
23.
Zurück zum Zitat Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A et al (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6(2):249–262CrossRef Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A et al (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6(2):249–262CrossRef
24.
Zurück zum Zitat Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1(1):74–81CrossRef Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1(1):74–81CrossRef
25.
Zurück zum Zitat Holmes DR Jr, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR et al (2012) 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol 59(13):1200–1254CrossRef Holmes DR Jr, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR et al (2012) 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol 59(13):1200–1254CrossRef
26.
Zurück zum Zitat Detaint D, Lepage L, Himbert D, Brochet E, Messika-Zeitoun D, Iung B et al (2009) Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. JACC Cardiovasc Interv 2(9):821–827CrossRef Detaint D, Lepage L, Himbert D, Brochet E, Messika-Zeitoun D, Iung B et al (2009) Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. JACC Cardiovasc Interv 2(9):821–827CrossRef
27.
Zurück zum Zitat Tay EL, Gurvitch R, Wijeysinghe N, Nietlispach F, Leipsic J, Wood DA et al (2011) Outcome of patients after transcatheter aortic valve embolization. JACC Cardiovasc Interv 4(2):228–234CrossRef Tay EL, Gurvitch R, Wijeysinghe N, Nietlispach F, Leipsic J, Wood DA et al (2011) Outcome of patients after transcatheter aortic valve embolization. JACC Cardiovasc Interv 4(2):228–234CrossRef
28.
Zurück zum Zitat Blanke P, Reinohl J, Schlensak C, Siepe M, Pache G, Euringer W et al (2012) Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv 5(4):540–548CrossRef Blanke P, Reinohl J, Schlensak C, Siepe M, Pache G, Euringer W et al (2012) Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv 5(4):540–548CrossRef
29.
Zurück zum Zitat Barbanti M, Yang TH, Rodes Cabau J, Tamburino C, Wood DA, Jilaihawi H et al (2013) Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation 128(3):244–253CrossRef Barbanti M, Yang TH, Rodes Cabau J, Tamburino C, Wood DA, Jilaihawi H et al (2013) Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation 128(3):244–253CrossRef
30.
Zurück zum Zitat Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C et al (2013) Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol 61(15):1585–1595CrossRef Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C et al (2013) Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol 61(15):1585–1595CrossRef
31.
Zurück zum Zitat Ribeiro HB, Webb JG, Makkar RR, Cohen MG, Kapadia SR, Kodali S et al (2013) Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry. J Am Coll Cardiol 62(17):1552–1562CrossRef Ribeiro HB, Webb JG, Makkar RR, Cohen MG, Kapadia SR, Kodali S et al (2013) Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry. J Am Coll Cardiol 62(17):1552–1562CrossRef
32.
33.
Zurück zum Zitat Badiani S, Bhattacharyya S, Lloyd G (2016) Role of echocardiography before transcatheter aortic valve implantation (TAVI). Curr Cardiol Rep 18(4):38CrossRef Badiani S, Bhattacharyya S, Lloyd G (2016) Role of echocardiography before transcatheter aortic valve implantation (TAVI). Curr Cardiol Rep 18(4):38CrossRef
34.
Zurück zum Zitat Siegel RJ, Luo H (2012) Echocardiography in transcatheter aortic valve implantation and mitral valve clip. Korean J Intern Med 27(3):245–261CrossRef Siegel RJ, Luo H (2012) Echocardiography in transcatheter aortic valve implantation and mitral valve clip. Korean J Intern Med 27(3):245–261CrossRef
35.
Zurück zum Zitat Altiok E, Koos R, Schroder J, Brehmer K, Hamada S, Becker M et al (2011) Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart 97(19):1578–1584CrossRef Altiok E, Koos R, Schroder J, Brehmer K, Hamada S, Becker M et al (2011) Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart 97(19):1578–1584CrossRef
36.
Zurück zum Zitat Muraru D, Badano LP, Vannan M, Iliceto S (2012) Assessment of aortic valve complex by three-dimensional echocardiography: a framework for its effective application in clinical practice. Eur Heart J Cardiovasc Imaging 13(7):541–555CrossRef Muraru D, Badano LP, Vannan M, Iliceto S (2012) Assessment of aortic valve complex by three-dimensional echocardiography: a framework for its effective application in clinical practice. Eur Heart J Cardiovasc Imaging 13(7):541–555CrossRef
37.
Zurück zum Zitat Saitoh T, Shiota M, Izumo M, Gurudevan SV, Tolstrup K, Siegel RJ et al (2012) Comparison of left ventricular outflow geometry and aortic valve area in patients with aortic stenosis by 2-dimensional versus 3-dimensional echocardiography. Am J Cardiol 109(11):1626–1631CrossRef Saitoh T, Shiota M, Izumo M, Gurudevan SV, Tolstrup K, Siegel RJ et al (2012) Comparison of left ventricular outflow geometry and aortic valve area in patients with aortic stenosis by 2-dimensional versus 3-dimensional echocardiography. Am J Cardiol 109(11):1626–1631CrossRef
38.
Zurück zum Zitat Wiley BM, Kovacic JC, Basnet S, Makoto A, Chaudhry FA, Kini AS et al (2016) Intraprocedural TAVR annulus sizing using 3D TEE and the “turnaround rule”. JACC Cardiovasc Imaging 9(2):213–215CrossRef Wiley BM, Kovacic JC, Basnet S, Makoto A, Chaudhry FA, Kini AS et al (2016) Intraprocedural TAVR annulus sizing using 3D TEE and the “turnaround rule”. JACC Cardiovasc Imaging 9(2):213–215CrossRef
39.
Zurück zum Zitat Tsang W, Bateman MG, Weinert L, Pellegrini G, Mor-Avi V, Sugeng L et al (2012) Accuracy of aortic annular measurements obtained from three-dimensional echocardiography, CT and MRI: human in vitro and in vivo studies. Heart 98(15):1146–1152CrossRef Tsang W, Bateman MG, Weinert L, Pellegrini G, Mor-Avi V, Sugeng L et al (2012) Accuracy of aortic annular measurements obtained from three-dimensional echocardiography, CT and MRI: human in vitro and in vivo studies. Heart 98(15):1146–1152CrossRef
40.
Zurück zum Zitat Jilaihawi H, Doctor N, Kashif M, Chakravarty T, Rafique A, Makar M et al (2013) Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography. J Am Coll Cardiol 61(9):908–916CrossRef Jilaihawi H, Doctor N, Kashif M, Chakravarty T, Rafique A, Makar M et al (2013) Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography. J Am Coll Cardiol 61(9):908–916CrossRef
41.
Zurück zum Zitat Bersvendsen JBJ, Urheim S, Aakhus S, Samset E (2014) Automatic measurement of aortic annulus diameter in 3-dimensional transoesophageal echocardiography. BMC Med Imaging 14:31CrossRef Bersvendsen JBJ, Urheim S, Aakhus S, Samset E (2014) Automatic measurement of aortic annulus diameter in 3-dimensional transoesophageal echocardiography. BMC Med Imaging 14:31CrossRef
42.
Zurück zum Zitat Mahmood F, Jeganathan J, Saraf R, Shahul S, Swaminathan M, Mackensen GB et al (2016) A practical approach to an intraoperative three-dimensional transesophageal echocardiography examination. J Cardiothorac Vasc Anesth 30(2):470–490CrossRef Mahmood F, Jeganathan J, Saraf R, Shahul S, Swaminathan M, Mackensen GB et al (2016) A practical approach to an intraoperative three-dimensional transesophageal echocardiography examination. J Cardiothorac Vasc Anesth 30(2):470–490CrossRef
43.
Zurück zum Zitat Pawade TA, Newby DE, Dweck MR (2015) Calcification in aortic stenosis: the skeleton key. J Am Coll Cardiol 66(5):561–577CrossRef Pawade TA, Newby DE, Dweck MR (2015) Calcification in aortic stenosis: the skeleton key. J Am Coll Cardiol 66(5):561–577CrossRef
44.
Zurück zum Zitat Philip F, Faza NN, Schoenhagen P, Desai MY, Tuzcu EM, Svensson LG et al (2015) Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies. Catheter Cardiovasc Interv 86(2):E88–E98CrossRef Philip F, Faza NN, Schoenhagen P, Desai MY, Tuzcu EM, Svensson LG et al (2015) Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies. Catheter Cardiovasc Interv 86(2):E88–E98CrossRef
45.
Zurück zum Zitat Otto CM, Kumbhani DJ, Alexander KP, Calhoon JH, Desai MY, Kaul S et al (2017) 2017 ACC expert consensus decision pathway for transcatheter aortic valve replacement in the management of adults with aortic stenosis: a report of the american college of cardiology task force on clinical expert consensus documents. J Am Coll Cardiol 69(10):1313–1346CrossRef Otto CM, Kumbhani DJ, Alexander KP, Calhoon JH, Desai MY, Kaul S et al (2017) 2017 ACC expert consensus decision pathway for transcatheter aortic valve replacement in the management of adults with aortic stenosis: a report of the american college of cardiology task force on clinical expert consensus documents. J Am Coll Cardiol 69(10):1313–1346CrossRef
46.
Zurück zum Zitat Queiros S, Dubois C, Morais P, Adriaenssens T, Fonseca JC, Vilaca JL et al (2017) Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation. J Cardiovasc Comput Tomogr 11(1):25–32CrossRef Queiros S, Dubois C, Morais P, Adriaenssens T, Fonseca JC, Vilaca JL et al (2017) Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation. J Cardiovasc Comput Tomogr 11(1):25–32CrossRef
47.
Zurück zum Zitat Watanabe Y, Morice MC, Bouvier E, Leong T, Hayashida K, Lefevre T et al (2013) Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Interv 6(9):955–964CrossRef Watanabe Y, Morice MC, Bouvier E, Leong T, Hayashida K, Lefevre T et al (2013) Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Interv 6(9):955–964CrossRef
48.
Zurück zum Zitat Shivaraju A, Thilo C, Ott I, Mayr PN, Schunkert H, von Scheidt W et al (2015) Tools and techniques—clinical: fluoroscopic balloon sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR)—follow the “right cusp rule”. EuroIntervention 11(7):840–842CrossRef Shivaraju A, Thilo C, Ott I, Mayr PN, Schunkert H, von Scheidt W et al (2015) Tools and techniques—clinical: fluoroscopic balloon sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR)—follow the “right cusp rule”. EuroIntervention 11(7):840–842CrossRef
49.
Zurück zum Zitat Frangieh AH, Ott I, Michel J, Shivaraju A, Joner M, Mayr NP et al (2017) Standardized minimalistic transfemoral transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 device: stepwise description, feasibility and safety from a large consecutive single-center single- operator cohort. Struct Heart 1:000–000CrossRef Frangieh AH, Ott I, Michel J, Shivaraju A, Joner M, Mayr NP et al (2017) Standardized minimalistic transfemoral transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 device: stepwise description, feasibility and safety from a large consecutive single-center single- operator cohort. Struct Heart 1:000–000CrossRef
50.
Zurück zum Zitat Babaliaros VC, Liff D, Chen EP, Rogers JH, Brown RA, Thourani VH et al (2008) Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size? JACC Cardiovasc Interv 1(5):580–586CrossRef Babaliaros VC, Liff D, Chen EP, Rogers JH, Brown RA, Thourani VH et al (2008) Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size? JACC Cardiovasc Interv 1(5):580–586CrossRef
51.
Zurück zum Zitat Frangieh AH, Kasel AM (2017) TAVI in bicuspid aortic valves ‘made easy’. Eur Heart J 38(16):1177–1181CrossRef Frangieh AH, Kasel AM (2017) TAVI in bicuspid aortic valves ‘made easy’. Eur Heart J 38(16):1177–1181CrossRef
Metadaten
Titel
Aortic annulus sizing in stenotic bicommissural non-raphe-type bicuspid aortic valves: reconstructing a three-dimensional structure using only two hinge points
verfasst von
Antonio H. Frangieh
Jonathan Michel
Oliver Deutsch
Michael Joner
Costanza Pellegrini
Tobias Rheude
Sabine Bleiziffer
Albert Markus Kasel
Publikationsdatum
14.06.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 1/2019
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-018-1295-2

Weitere Artikel der Ausgabe 1/2019

Clinical Research in Cardiology 1/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.