Skip to main content
Erschienen in: BMC Oral Health 1/2015

Open Access 01.12.2015 | Research article

Apical extrusion of sodium hypochlorite activated with two laser systems and ultrasonics: a spectrophotometric analysis

verfasst von: Bağdagül Helvacıoğlu Kıvanç, Hacer Deniz Arısu, Nazlı Özge Yanar, Hülya Mercan Silah, Recai İnam, Güliz Görgül

Erschienen in: BMC Oral Health | Ausgabe 1/2015

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Background

The aim of the present study was to compare the effect of ultrasonically or laser (Nd:YAG or diode) activated irrigation on the irrigating solution extrusion compared to non-activated syringe irrigation.

Methods

Extracted mandibular premolar teeth (n = 48) with single canals were instrumented. The teeth were secured through the lid of an Eppendorf tube filled with 1.0 mL distilled water to collect the apically extruded irrigating solution. The teeth were randomly divided into four groups: non-activated syringe irrigation, diode laser, Nd:YAG laser and passive ultrasonic irrigation (PUI) using 2 % NaOCl. The irrigating solution extruded through the apical foramen was collected in the Eppendorf tube and evaluated by a chemical reaction with using a spectrophotometer. The data was analyzed using one-way ANOVA and Tukey’s post hoc test (α = 0.05).

Results

All the groups showed apically extruded irrigating solution. There were significant differences among the groups (p < 0.05). Nd:YAG laser activated irrigation showed greater extrusion (p < 0.05), while the non-activated syringe irrigation showed less extrusion (p < 0.05). Only the difference between diode laser and PUI was not statistically significant (p > 0.05).

Conclusion

Within the limitations of this in vitro study, the researchers concluded that non-activated syringe irrigation caused less apically extruded irrigating solution than PUI and LAI using Nd:YAG or diode lasers.
Hinweise

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

BHK formulated the conception and design of the study, participated in data acquisition and interpretation of data analysis and prepared the manuscript. HDA participated in the design of the study and interpretation of data analysis and performed the stastistical analysis. NÖY participated in data acquisition. HMS carried out the chemical analysis. Rİ contributed to data acquisition and interpretation of the chemical anaysis. GG participated in its design and coordination. All authors read and approved the final manuscript.
Abkürzungen
PUI
Passive ultrasonic irrigation
LAI
Laser-activated irrigation
NaOCl
Sodium hypochlorite
Nd:YAG laser
Neodymium-doped yttrium aluminium garnet laser
I2
Iodine

Background

Root canal irrigation plays an important role in the debridement and disinfection of the root canal system [1]. The goal of irrigation is to remove pulp tissue and/or microorganisms (planktonic or biofilm) from the root canal system [2]. Irrigation is also used to eliminate the smear layer and dentin debris, which occur following instrumentation of the root canal [3]. Sodium hypochlorite at various concentrations is widely used as an endodontic disinfectant thanks to the chemical properties of the pulp dissolution, effective antimicrobial action, dissolution of organic material, transformation of amines into chloramines, and deodorizing effects [46].
The mechanical and chemical effectiveness of an irrigation regimen depend on the working mechanisms of the irrigating solution and the ability to bring the irrigating solution in contact with those elements, materials, and structures within the canal system that should be removed [7]. Syringe irrigation is the standard procedure; however, it is not effective in the apical part of the canal [8] and in the isthmus and oval extensions [9]. Moreover, predictable delivery of irrigants to the working length with needle irrigation is not often attained [10]. Nonetheless, some studies suggest that the tip of an injection needle should be placed as close as possible to the apical end of the canal to clean the entire root canal length effectively [1012]. However, it may increase the risk of extrusion of the solution [13]. As the irrigating solutions are usually cytotoxic, the possibility of an accidental extrusion beyond the apical construction should be considered during root canal irrigation.
Passive ultrasonic irrigation (PUI) was first described by Weller et al. [14]. When a small file or smooth wire placed at the center of the root canal that does not contact the canal wall is activated ultrasonically, ‘acoustic streaming’ occurs. As the root canal is enlarged, the file or wire can vibrate freely in a way to enable acoustic streaming, thereby transferring its energy to the irrigating solution throughout the canal [15]. Various studies have shown that NaOCl used with PUI removes more dentin debris, planktonic bacteria, and pulp tissue from the root canal compared to syringe irrigation [16, 17].
Laser-activated irrigation (LAI) has been introduced as a powerful method for root canal irrigation. Past work has shown that solid-state laser systems with short pulse durations can induce pressure waves in water, including the near-infrared Nd:YAG laser [18] and more recently the middle infrared Er:YAG and Er,Cr:YSGG lasers [19, 20] These laser-generated pressure waves move at high speed, with different characteristics from waves induced by freely vibrating sonic and ultrasonic endodontic instruments [18] and appear to enhance the action of endodontic irrigating solutions in terms of smear layer removal [21]. In the study of Hmud et al. [22] laser-induced cavitations with near-infrared diode lasers was shown in a glass capillary tube model. The laser radiation produces transient cavitation in the liquid through the optical breakdown by absorption of the laser energy. Laser-activated irrigation may result not only in the removal of the smear layer from the root canal wall, but also extrusion of irrigating solution through the apex [20, 21].
The aim of the present study was to compare the effect of ultrasonically or laser (ND:YAG or Diode) activated irrigation on the irrigating solution extrusion compared to non-activated syringe irrigation (control).
The null hypothesis was that the activation methods did not result in more apical extrusion than the control group.

Methods

This study was approved by Ethics Committee of Ankara University Faculty of Dentistry, Turkey, in accordance with the Declaration of Helsinki (Reference number:36290600/121).
For this study, forty-eight (N = 48) freshly extracted single-rooted human mandibular premolar teeth with single canals were collected from the Clinic of the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Gazi University of Ankara, Turkey. The teeth with straight root canals of similar size were included to reduce the effects of canal size and curvature on the extrusion of the irrigant. Radiographic images from the buccal and proximal aspects for each sample were exposed. The teeth with an open apex in the radiographic images were excluded from the study.
Following extraction, the teeth were stored for two days in 3 % NaOCl at room temperature to remove organic debris. They were scaled with ultrasonics, washed with distilled water to remove any calculus or soft tissue debris, and then immersed in 10 % formalin solution until use.
The teeth were decoronated to obtain root segments of 14-mm in length. A 10-K file (Antaeos; Vereinigte Dentalwerke GmbH & Co, Munich, Germany) was placed into the canal until it was visible at the apical foramen. The working length was established as 0.5 mm short of this length.
The root canal preparation was performed using rotary instruments (ProTaper, Dentsply, Maillefer, Ballaigues, Switzerland) with a crown down technique. Apical instrumentation was completed with a F3 file (ISO size 30, taper 0.09-0.05). Between the instruments, each canal was irrigated with 2 mL of 2 % NaOCl solution using a syringe and 27-gauge needle. Apical patency was checked with a size 10-K file between each instrument. The teeth were secured with self-curing acrylic resin through the lid of an Eppendorf tube filled with 1.0 mL distilled water to collect the apically extruded irrigating solution. 27-gauge needle was inserted into the Eppendorf tube to equalize the pressure inside and outside the tube (Fig. 1)
The volume of the irrigating solution was kept constant as 4 mL for all control and experimental groups.
Non-activated syringe irrigation (Control group): 4 mL of 2 % NaOCl was injected into the root canals in 60 s with a 27-gauge open-end tip needle, which was placed 2-mm short of the working length without binding (with a constant fluid flow rate of 0.7 mL/sec).
LAI using diode laser (Pocket Diode Laser, Orotig, Verona, Italy): the diode laser (915 nm, 1.2 W, 200 μm fiber optic tip, continuous wave) was activated for a total of 21 s (3 X 7 sec).
LAI using Nd:YAG laser (Pulse Master 600 IQ, Texas, USA): Nd:YAG laser (120 mJ, 20 Hz, 2.4 W, 320 μm fiber optic tip, pulsed mode) was activated for 20 s.
PUI (Satelec, Acteon Group, Merignac, France): PUI was performed with a piezoelectrical ultrasonic unit with power setting 5. A stainless steel size 15-K file (Satalec) was inserted into the root canal and the irrigating solution was ultrasonically activated for 60 s [23].
After LAI using diode laser, LAI using Nd:YAG laser and PUI, the root canals were irrigated with 2 mL of 2 % NaOCl for 30 s with a 27-gauge needle, which was placed 2 mm short of the working length (with a constant fluid flow rate of 0.7 mL/sec).
The quantitiy of hydrochloride ion in an aqueous sample can be determined by finding out how much iodine it can produce by oxidizing an iodide ion [24]. The amount of the extruded NaOCl in the Eppendorf tubes was determined by this chemical reaction of OCl with I (iodide) in acidic solution.
$$ \begin{array}{l}\\ {}\begin{array}{ll}\mathbf{2}{\mathbf{e}}^{-} + \mathbf{2}{\mathbf{H}}^{+} + \mathbf{O}\mathbf{C}{\mathbf{l}}^{-}\hfill & \kern0.36em \mathbf{C}{\mathbf{l}}^{-} + {\mathbf{H}}_{\mathbf{2}}\mathbf{O}\hfill \\ {}\mathbf{2}{\mathbf{I}}^{-}\hfill & \kern0.36em {\mathbf{I}}_{\mathbf{2}} + \mathbf{2}{\mathbf{e}}^{-}\hfill \\ {}\mathbf{2}{\mathbf{H}}^{+} + \mathbf{O}\mathbf{C}{\mathbf{l}}^{-} + \mathbf{2}{\mathbf{I}}^{-}\hfill & \kern0.36em {\mathbf{I}}_{\mathbf{2}} + \mathbf{C}{\mathbf{l}}^{-} + {\mathbf{H}}_{\mathbf{2}}\mathbf{O}\hfill \end{array}\end{array} $$
Following the chemical reaction, the amount of NaOCl was determined by spectrophotometric assessment of the change in color due to the formation of iodine (I2) in an aqueous solution with a spectrophotometer (Unicam UV2-100 UV/Visible Spectrometer, Aberdeen, UK). The statistical analysis was performed using one-way analysis of variance (ANOVA) and Tukey’s post hoc tests (α = 0.05).

Results

The concentration of the apically extruded irrigating solution is presented in Fig. 2. All the groups showed apical extrusion of irrigating solution. There were significant differences between the groups. (p < 0.05). The non-activated syringe irrigation showed less extrusion, while LAI using Nd:YAG laser showed a greater amount of extrusion. There was only not a significant difference between the LAI using diode laser and PUI (p > 0.05).

Discussion

With the aim of comparing the effect of the methods used for improving the efficacy of NaOCl irrigation, the researchers assessed more apical extrusion of the irrigant as a result of activating the irrigation solution with different systems. The null hypothesis was rejected.
The protocol for this study was designed to maximize the possibility of extrusion of irrigating solution through an unrestricted, yet normal apex. To standardize the apical constriction, apical patency was checked with a size 10-K file between each instrument. All control and activated groups were irrigated from 2 mm short of the working length with 4 mL NaOCl using 27- gauge needle for obtaining a standardization of irrigation. In laser groups the fiber tip was inserted 1 mm short of the working length as the manufacturers’ instructions. In PUI group the file was also inserted 1 mm short of the working length to obtain standardization between activations. In the present study, each tooth was secured through the lid of an Eppendorf tube filled with distilled water to collect the apically extruded irrigating solution. The amount of extruded NaOCl in the Eppendorf tubes was determined by the chemical reaction of OCl with I (iodide) in an acidic solution. Following the chemical reaction, the amount of NaOCl was determined by spectrophotometric assessment of the change in color due to the formation of iodine (I2) in aqueous solution which is consistent for detecting small increments of extruded material. Various methods have been used to evaluate apical extrusion of irriganting solutions in vitro, however this model provides sensitivity along with quantification of extrusion of irrigating solution [24, 25].
The results of the current study revealed that apical extrusion increased with the activation of sodium hypochlorite irrigation. Non-activated syringe irrigation showed less apical extrusion of irrigating solution than activated methods. Meire et al. [26] found that the absorption coefficient values of NaOCl at 980 nm diode laser and 1064 nm Nd:YAG laser are 0.250 and 0.108 cm−1 respectively. These values are well below the absorbtion coefficient values required for occurrence of cavitation at the laser tip (10 cm−1). However, the absorption coefficient of the irrigation solution is not the only factor that effects the occurance of cavitation at the laser fiber tip. The wavelength, power density and energy density also play a role. It has been suggested that 940-nm and 980-nm diode lasers also are able to induce cavitations and hence activate irrigants [22]. Lauterborn and Ohl [27] produced cavitation bubbles in water using a laser with very low absorption in water (Nd:YAG laser; 1.064 nm alpha of 0.1 cm−1 98 % transmission through 1 mm). In this study although apical extrusion occurred with both lasers in different modes, the Nd:YAG laser activation showed a greater amount of extrusion of irrigating solution. As the lasers were used in accordance with the manufacturers’ instructions, it may be related to high power setting of Nd:YAG laser. In this study, diode laser was used in a continuous wave, whereas the Nd:YAG laser was used in pulsed mode. Due to the pulsations of the laser, the fluid becomes accelerated at every pulse and the acceleration gives rise to the inertia forces [28]. Pulsed lasers can create pressure waves of sufficient force to propel microdroplets of the aqueous irrigating solution beyond the apical constriction [18]. Thus, caution should be exercised when using such lasers in combination with irrigating solutions such as sodium hypochlorite.
The PUI group also showed apical extrusion of irrigating solution. One of the previous studies showed that systems using ultrasound cleaned the endodontic space more effectively; however, that cleansing action was more difficult to control [29] . There might be a risk of pushing the irrigating solution beyond the apex. The PUI system showed absolute safety when used at 5 and 3 mm, whereas there was some extrusion of NaOCl in almost all tests at 1 mm [29]. The result of this study, contradicts an earlier report [30] which concluded that no significant difference was detected between PUI techniques and passive extrusion (control) of irrigating solution. The application time (10 s) of PUI differs from this study (60s). In a spectrophotometric study, Rodriguez-Figueroa et al. [25] used PUI 2 mm short from the working length, and concluded that PUI as a safe device. However, in this study we used PUI 1 mm short from the working length.

Conclusion

Within the limitations of this in vitro study, the researchers concluded that non-activated syringe irrigation caused less apical extrusion of irrigating solution than PUI and LAI using Nd:YAG or diode lasers..

Acknowledgements

This study was funded by Scientific Research Projects Unit of Gazi University.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
The Creative Commons Public Domain Dedication waiver (https://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

BHK formulated the conception and design of the study, participated in data acquisition and interpretation of data analysis and prepared the manuscript. HDA participated in the design of the study and interpretation of data analysis and performed the stastistical analysis. NÖY participated in data acquisition. HMS carried out the chemical analysis. Rİ contributed to data acquisition and interpretation of the chemical anaysis. GG participated in its design and coordination. All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Lee SJ, Wu MK, Wesselink PR. The effectiveness of syringe irrigation and ultrasonics to remove debris from simulated irregularities within prepared root canal walls. Int Endod J. 2004;37:672–8.CrossRefPubMed Lee SJ, Wu MK, Wesselink PR. The effectiveness of syringe irrigation and ultrasonics to remove debris from simulated irregularities within prepared root canal walls. Int Endod J. 2004;37:672–8.CrossRefPubMed
2.
Zurück zum Zitat Haapasalo M, Endal U, Zandi H, Coil JM. Eradication of endodontic infection by instrumentation and irrigation solutions. Endod Topics. 2005;10:77–102.CrossRef Haapasalo M, Endal U, Zandi H, Coil JM. Eradication of endodontic infection by instrumentation and irrigation solutions. Endod Topics. 2005;10:77–102.CrossRef
3.
Zurück zum Zitat Baugh D, Wallace J. The role of apical instrumentation in root canal treatment: a review of the literature. J Endod. 2005;31:333–40.CrossRefPubMed Baugh D, Wallace J. The role of apical instrumentation in root canal treatment: a review of the literature. J Endod. 2005;31:333–40.CrossRefPubMed
4.
Zurück zum Zitat Marending M, Luder HU, Brunner TJ, Knecht S, Stark WJ, Zehnder M. Effect of sodium hypochlorite on human root dentine–mechanical, chemical and structural evaluation. Int Endod J. 2007;40:786–93.CrossRefPubMed Marending M, Luder HU, Brunner TJ, Knecht S, Stark WJ, Zehnder M. Effect of sodium hypochlorite on human root dentine–mechanical, chemical and structural evaluation. Int Endod J. 2007;40:786–93.CrossRefPubMed
5.
Zurück zum Zitat Spanó JC, Barbin EL, Santos TC, Guimarães LF, Pécora JD. Solvent action of sodium hypochlorite on bovine pulp and physico-chemical properties of resulting liquid. Braz Dent J. 2001;12:154–7.PubMed Spanó JC, Barbin EL, Santos TC, Guimarães LF, Pécora JD. Solvent action of sodium hypochlorite on bovine pulp and physico-chemical properties of resulting liquid. Braz Dent J. 2001;12:154–7.PubMed
6.
Zurück zum Zitat Sirtes G, Waltimo T, Schaetzle M, Zehnder M. The effects of temperature on sodium hypochlorite short-term stability, pulp dissolution capacity, and antimicrobial efficacy. J Endod. 2005;31:669–71.CrossRefPubMed Sirtes G, Waltimo T, Schaetzle M, Zehnder M. The effects of temperature on sodium hypochlorite short-term stability, pulp dissolution capacity, and antimicrobial efficacy. J Endod. 2005;31:669–71.CrossRefPubMed
7.
Zurück zum Zitat Chow TW. Mechanical effectiveness of root canal irrigation. J Endod. 1983;11:475–9.CrossRef Chow TW. Mechanical effectiveness of root canal irrigation. J Endod. 1983;11:475–9.CrossRef
8.
Zurück zum Zitat Jiang LM, Lak B, Eijsvogels LM, Wesselink P, van der Sluis LW. Comparison of the cleaning efficacy of different final irrigation techniques. J Endod. 2012;38:838–41.CrossRefPubMed Jiang LM, Lak B, Eijsvogels LM, Wesselink P, van der Sluis LW. Comparison of the cleaning efficacy of different final irrigation techniques. J Endod. 2012;38:838–41.CrossRefPubMed
9.
Zurück zum Zitat Lee SJ, Wu MK, Wesselink PR. The efficacy of ultrasonic irrigation to remove artificially placed dentin debris from different sized simulated plastic root canals. Int Endod J. 2004;37:607–12.CrossRefPubMed Lee SJ, Wu MK, Wesselink PR. The efficacy of ultrasonic irrigation to remove artificially placed dentin debris from different sized simulated plastic root canals. Int Endod J. 2004;37:607–12.CrossRefPubMed
10.
Zurück zum Zitat Goldman M, Kronman JH, Goldman LB, Clausen H, Grady J. New method of irrigation during endodontic treatment. J Endod. 1976;2:257–60.CrossRefPubMed Goldman M, Kronman JH, Goldman LB, Clausen H, Grady J. New method of irrigation during endodontic treatment. J Endod. 1976;2:257–60.CrossRefPubMed
11.
Zurück zum Zitat Abou-Rass M, Piccinino MV. The effectiveness of four clinical irrigation methods on the removal of root canal debris. Oral Surg Oral Med Oral Pathol. 1982;54:323–8.CrossRefPubMed Abou-Rass M, Piccinino MV. The effectiveness of four clinical irrigation methods on the removal of root canal debris. Oral Surg Oral Med Oral Pathol. 1982;54:323–8.CrossRefPubMed
12.
Zurück zum Zitat Sedgley CM, Nagel AC, Hall D, Applegate B. Influence of irrigant needle depth in removing bioluminescent bacteria inoculated into instrumented root canals using real-time imaging in vitro. Int Endod J. 2005;38:97–104.CrossRefPubMed Sedgley CM, Nagel AC, Hall D, Applegate B. Influence of irrigant needle depth in removing bioluminescent bacteria inoculated into instrumented root canals using real-time imaging in vitro. Int Endod J. 2005;38:97–104.CrossRefPubMed
13.
Zurück zum Zitat Mitchell RP, Baumgartner JC, Sedgley CM. Apical extrusion of sodium hypochlorite using different root canal irrigation systems. J Endod. 2011;37:1677–81.CrossRefPubMed Mitchell RP, Baumgartner JC, Sedgley CM. Apical extrusion of sodium hypochlorite using different root canal irrigation systems. J Endod. 2011;37:1677–81.CrossRefPubMed
14.
15.
Zurück zum Zitat Ahmad M, Pitt Ford TJ, Crum LA. Ultrasonic debridement of root canals: aninsight into the mechanisms involved. J Endod. 1987;13:490–9.CrossRefPubMed Ahmad M, Pitt Ford TJ, Crum LA. Ultrasonic debridement of root canals: aninsight into the mechanisms involved. J Endod. 1987;13:490–9.CrossRefPubMed
16.
Zurück zum Zitat Huque J, Kota K, Yamaga M, Iwaku M, Hoshino E. Bacterial eradication from root dentine by ultrasonic irrigation with sodium hypochlorite. Int Endod J. 1998;31:242–50.CrossRefPubMed Huque J, Kota K, Yamaga M, Iwaku M, Hoshino E. Bacterial eradication from root dentine by ultrasonic irrigation with sodium hypochlorite. Int Endod J. 1998;31:242–50.CrossRefPubMed
17.
Zurück zum Zitat Gutarts R, Nusstein J, Reader A, Beck M. In vivo debridement efficacy of ultrasonic irrigation following hand rotary instrumentation in human mandibular molars. J Endod. 2005;31:166–70.CrossRefPubMed Gutarts R, Nusstein J, Reader A, Beck M. In vivo debridement efficacy of ultrasonic irrigation following hand rotary instrumentation in human mandibular molars. J Endod. 2005;31:166–70.CrossRefPubMed
18.
Zurück zum Zitat Levy G, Rizoiu L, Friedman S, Lam H. Pressure waves in root canals induced by Nd:YAG laser. J Endod. 1996;22:81–4.CrossRefPubMed Levy G, Rizoiu L, Friedman S, Lam H. Pressure waves in root canals induced by Nd:YAG laser. J Endod. 1996;22:81–4.CrossRefPubMed
19.
Zurück zum Zitat Blanken JW, Verdaasdonk RM. Cavitation as a working mechanism of the Er, Cr:YSGG laser in endodontics: a visualization study. J Oral Laser Appl. 2007;7:97–106. Blanken JW, Verdaasdonk RM. Cavitation as a working mechanism of the Er, Cr:YSGG laser in endodontics: a visualization study. J Oral Laser Appl. 2007;7:97–106.
20.
Zurück zum Zitat George R, Walsh LJ. Apical extrusion of root canal irrigants when using Er:YAG and Er, Cr:YSGG lasers with optical fibers: an in vitro dye study. J Endod. 2008;34:706–8.CrossRefPubMed George R, Walsh LJ. Apical extrusion of root canal irrigants when using Er:YAG and Er, Cr:YSGG lasers with optical fibers: an in vitro dye study. J Endod. 2008;34:706–8.CrossRefPubMed
21.
Zurück zum Zitat George R, Meyers IA, Walsh LJ. Laser activation of endodontic irrigants with improved conical laser fiber tips for removing smear layer in the apical third of the root canal. J Endod. 2008;34:1524–7.CrossRefPubMed George R, Meyers IA, Walsh LJ. Laser activation of endodontic irrigants with improved conical laser fiber tips for removing smear layer in the apical third of the root canal. J Endod. 2008;34:1524–7.CrossRefPubMed
22.
Zurück zum Zitat Hmud R, Kahler WA, George R, Walsh LJ. Cavitational effects in aqueous endodontic irrigants generated by near-infrared lasers. J Endod. 2010;36:275–8.CrossRefPubMed Hmud R, Kahler WA, George R, Walsh LJ. Cavitational effects in aqueous endodontic irrigants generated by near-infrared lasers. J Endod. 2010;36:275–8.CrossRefPubMed
23.
Zurück zum Zitat Mancini M, Cerroni L, Iorio L, Armellin E, Conte G, Cianconi L. Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and passive ultrasonic irrigation): field emission scanning electron microscopic evaluation in an in vitro study. J Endod. 2013;39:1456–60.CrossRefPubMed Mancini M, Cerroni L, Iorio L, Armellin E, Conte G, Cianconi L. Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and passive ultrasonic irrigation): field emission scanning electron microscopic evaluation in an in vitro study. J Endod. 2013;39:1456–60.CrossRefPubMed
24.
Zurück zum Zitat Pasha C: Studies on new reagents for the spectrophotometric determination of anions, metals and drugs. Doctorate Thesis. Mangalore University Department of Post Graduate Studies and Research in Chemistry, India, 2008. Pasha C: Studies on new reagents for the spectrophotometric determination of anions, metals and drugs. Doctorate Thesis. Mangalore University Department of Post Graduate Studies and Research in Chemistry, India, 2008.
25.
Zurück zum Zitat Rodríguez-Figueroa C, McClanahan SB, Bowles WR. Spectrophotometric determination of irrigant extrusion using passive ultrasonic irrigation, EndoActivator, or syringe irrigation. J Endod. 2014;40:1622–6.CrossRefPubMed Rodríguez-Figueroa C, McClanahan SB, Bowles WR. Spectrophotometric determination of irrigant extrusion using passive ultrasonic irrigation, EndoActivator, or syringe irrigation. J Endod. 2014;40:1622–6.CrossRefPubMed
26.
Zurück zum Zitat Meire MA, Poelman D, De Moor RJ. Optical properties of root canal irrigants in the 300–3,000-nm wavelength region. Lasers Med Sci. 2014;29:1557–62.CrossRefPubMed Meire MA, Poelman D, De Moor RJ. Optical properties of root canal irrigants in the 300–3,000-nm wavelength region. Lasers Med Sci. 2014;29:1557–62.CrossRefPubMed
27.
28.
Zurück zum Zitat de Groot SD, Verhaagen B, Versluis M, Wu MK, Wesselink PR, van der Sluis LW. Laser-activated irrigation within root canals: cleaning efficacy and flow visualization. Int Endod J. 2009;42:1077–83.CrossRefPubMed de Groot SD, Verhaagen B, Versluis M, Wu MK, Wesselink PR, van der Sluis LW. Laser-activated irrigation within root canals: cleaning efficacy and flow visualization. Int Endod J. 2009;42:1077–83.CrossRefPubMed
29.
Zurück zum Zitat Malentacca A, Uccioli U, Zangari D, Lajolo C, Fabiani C. Efficacy and safety of various active irrigation devices when used with either positive or negative pressure: an in vitro study. J Endod. 2012;38:1622–6.CrossRefPubMed Malentacca A, Uccioli U, Zangari D, Lajolo C, Fabiani C. Efficacy and safety of various active irrigation devices when used with either positive or negative pressure: an in vitro study. J Endod. 2012;38:1622–6.CrossRefPubMed
30.
Zurück zum Zitat Boutsioukis C, Psimma Z, Kastrinakis E. The effect of flow rate and agitation technique on irrigant extrusion ex vivo. Int Endod J. 2014;47:487–96.CrossRefPubMed Boutsioukis C, Psimma Z, Kastrinakis E. The effect of flow rate and agitation technique on irrigant extrusion ex vivo. Int Endod J. 2014;47:487–96.CrossRefPubMed
Metadaten
Titel
Apical extrusion of sodium hypochlorite activated with two laser systems and ultrasonics: a spectrophotometric analysis
verfasst von
Bağdagül Helvacıoğlu Kıvanç
Hacer Deniz Arısu
Nazlı Özge Yanar
Hülya Mercan Silah
Recai İnam
Güliz Görgül
Publikationsdatum
01.12.2015
Verlag
BioMed Central
Erschienen in
BMC Oral Health / Ausgabe 1/2015
Elektronische ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-015-0056-0

Weitere Artikel der Ausgabe 1/2015

BMC Oral Health 1/2015 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.