Abstract

Background

Ventana ALK (D5F3) screening of anaplastic lymphoma kinase (ALK) gene rearrangement in tissue specimens has been approved by US FDA (Food and Drug Administration) to select treatment for non–small-cell lung carcinoma (NSCLC). However, tumor tissues are often not readily obtainable, and cytology specimens and may be the only tumor material available for diagnosis and molecular marker analysis. In this study, we evaluated the feasibility of ALK immunocytochemistry (ICC) on ThinPrep slides and determined a suitable scoring system for interpretation of the results.

Methods

One hundred twenty-one fine-needle aspirate (FNA) specimens from metastatic lesions of NSCLC were analyzed. ALK rearrangement was detected on ThinPrep cytology slides using the Ventana immunocytochemistry ALK-D5F3 system, which adopts two scoring systems for interpretation of the ICC results. The results were subsequently confirmed by reverse transcription polymerase chain reaction (RT-PCR) analysis and fluorescence in situ hybridization (FISH).

Results

Among the 121 ICC specimens, 16 that were considered ALK-positive by either scoring system were referred for PCR analysis. Among the ALK ICC-negative cases, 33 had correlated FISH ALK results. A total of 49 specimens that exhibited either a positive or negative ICC result with a correlated ALK status were analyzed statistically. ICC results showed a high concordance rate with the results of PCR/FISH analysis. The sensitivity and specificity of ALK ICC by the binary scoring algorithm were 68.75 and 96.97%, respectively. These values increased to 93.75 and 96.97%, respectively, when interpreted by the semiquantified interpretation system.

Conclusions

ALK ICC analysis on ThinPrep slides is a reliable ALK testing method, and the semiquantified interpretation system on cytology specimens is recommended rather than the binary scoring algorithm on tissue specimens.
Hinweise
Hui Qin Guo and Jia Jia contributed equally to this work.
Abkürzungen
ALK
Anaplastic lymphoma kinase
FFEP
Formalin-fixed, paraffin-embedded
FISH
Fluorescence in situ hybridization
FNA
Fine-needle aspirate
ICC
Immunocytochemistry
IHC
Immunohistochemistry
NPV
Negative predictive value
NSCLC
Non–small-cell lung cancer
PPV
Positive predictive value
RT-PCR
Reverse-transcription polymerase chain reaction

Background

In the past decade, personalized medicine directed at specific molecular targets in tumors has helped improve the survival of patients with non–small-cell lung cancer (NSCLC) [1, 2]. For the treatment of patients with NSCLC harboring anaplastic lymphoma kinase (ALK) gene fusions, crizotinib, ceritinib, and alectinib have all been approved. ALK rearrangements have been reported in 3%-7% of lung tumors [35]. In clinical practice, 3 methods of detecting ALK rearrangements are generally used: fluorescence in situ hybridization (FISH), reverse-transcription polymerase chain reaction (RT-PCR) assays, and immunohistochemistry (IHC) analysis. Of these, IHC is easily practicable and less costly, and has been approved by the US FDA as a screening assay for detecting ALK rearrangements [69]. Currently, most studies of IHC have used tissue sections and only a few have focused on the feasibility of IHC using cytology specimens [10].
As lung cancer is only diagnosed at an advanced stage in many patients, there is often no opportunity for surgery. Consequently, tissue sections may not be readily obtainable and cytology specimens are sometimes the only tumor material available for diagnosis and molecular marker analysis [1113]. While formalin-fixed, paraffin-embedded cell blocks using the same processing methods as for tissue sections are ideal for IHC analysis, not all cytology materials are sufficient for cell block processing [14]. In such cases, direct smears or liquid-based slides such as ThinPrep, which are used for cytological diagnosis, may be the only available material for molecular marker analysis. Although ALK ICC analysis using direct cytology smears has been described previously [10, 15], to our knowledge, there are no published studies of the application of ALK ICC analysis on ThinPrep (liquid-based) slides.
In the present study, we performed ALK ICC analysis on ThinPrep slides, with the results interpreted by 2 separate scoring systems [7, 16]. To evaluate the accuracy of ALK ICC analysis on ThinPrep slides, the results with both scoring systems were correlated with ALK PCR/FISH results. We also determined the most suitable of the 2 scoring systems for ALK ICC analysis on ThinPrep slides.

Methods

Patient selection

A consecutive series of NSCLC patients evaluated in the Department of Pathology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences, Beijing between November 2013 and October 2016 comprised the study cohort. Specimens from the patients were selected for analysis on the following basis: (1) fine-needle aspirate (FNA) specimens were able to be obtained from metastatic lesions; (2) at least 15 mL of PreservCyt solution (Hologic Inc., Marlborough, MA, USA) was left in the specimen bottles; and (3) more than 100 tumor cells were present in Papanicolaou-stained ThinPrep slides (Hologic Inc, Marlborough, MA, USA) [17]. The liquid-based materials were stored at 4°C and submitted for ICC and molecular testing within 3 months.
The study protocol was reviewed and approved by the ethics committee of the National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences. All patients provided informed consent to participate in the study.

Immunocytochemistry (ICC) analysis

Liquid-based specimens were required to be at room temperature for 20 minutes before preparation of the ThinPrep slides. Automated ICC for ALK expression was performed on ThinPrep slides (each sample had 2 slides) using the highly sensitive anti-ALK (D5F3) rabbit monoclonal primary antibody and a corresponding negative control (Ventana Medical Systems Inc., Tucson, AZ, USA). The entire staining procedure was performed according to the manufacturer’s instructions on a BenchMark XT slide stainer (Ventana Medical Systems, Inc.).
For interpretation of the Ventana ALK (D5F3) ICC results, 2 scoring systems were adopted. The first of these, the binary scoring algorithm, which is recommended by the manufacturer, provides positive or negative results based on the granular cytoplasmic staining intensity. Any percentage of tumor cells presenting with strong granular cytoplasmic staining denotes positive ALK expression. The second system, the semiquantified interpretation system, rates ALK staining patterns as zero (no stain), 1+ (weak cytoplasmic stain seen at 400× magnification), 2+ (moderate cytoplasmic stain seen at 100× to 200× magnification), or 3+ (strong cytoplasmic stain seen at 20× to 40× magnification). Scores of 2+ and 3+ are considered ALK-positive, while scores of zero and 1+ are considered negative [10] (Fig. 1).
The staining intensity was scored according to both standards, and the results were reviewed independently by 2 experienced cytopathologists. If there was any discordance between them, the results were re-evaluated. Positive results determined by either scoring system were referred for RT-PCR analysis to confirm the ALK status.

Reverse-transcription polymerase chain reaction (RT-PCR) analysis

For RT-PCR analysis, cells in PreservCyt solution were first centrifuged, and the RNA was then extracted by a commercial RNA kit [AmoyDx® Tissue RNA Kit (Spin Column), Amoy Diagnostics Co., China]. The RNA quality control assessed by ratio of OD260 to OD280 ranged from 1.9 to 2.0, and the extracted RNA suggested immediate detection. The detection of EML4-ALK, including reverse transcriptase and PCR amplification, was performed by RT-PCR according to the manufacturer’s instructions using an AmoyDx® EML4-ALK Fusion Gene Detection Kit. If any EML4-ALK reaction has obvious sample FAM signal amplification curve and Ct <30, then the sample was positive for fusion gene. If all the sample EML4-ALK reaction holes have no FAM signal expansion, growth curve, or Ct = 30, the sample for detection of fusion gene is negative.

Fluorescence In Situ Hybridization (FISH) analysis

FISH was performed on tissue FFPE samples, using the Vysis LSI ALK Dual color Break Apart Probe, according to the manufacturer’s instructions. The LSI ALK 5′ probe (spectrum green) and the LSI ALK 3′ probe (spectrum orange) were applied, hybridized, and assessed along with standard controls according to our standard laboratory procedure and validation studies. A positive cell was defined as one in which the nucleus had split signals (three or more signal diameters apart) or a single orange signal (deleted green signal). A positive sample was considered when if >25 positive cells out of 50 were positive or if there was an average percentage of positive cells of ≥15% in 100 tumour cells. The results were reviewed independently by two experienced pathologists, and any discordance was reevaluated.

Statistical analysis

The ALK ICC results obtained with the binary scoring algorithm and the semiquantified interpretation system were measured with Cohen’s k coefficient. Differences between the ICC interpretations with the 2 scoring systems were analyzed with a χ2 test. All statistical analyses were performed with SPSS® 19.0 (SPSS Inc, Chicago, IL, USA). A P value <0.05 was considered statistically significant.

Results

Patient characteristics

A total of 121 FNA specimens were obtained from 121 NSCLC patients with near or distant metastases, including specimens from supraclavicular lymph nodes (n = 106), mediastinal lymph nodes (n = 10), axillary lymph nodes (n = 2), the chest wall (n = 2), and liver (n = 1). The 121 patients included 75 males and 46 females, and their median age was 58 years. Histological diagnoses included metastatic adenocarcinoma in 83.47% of the patients (101/121), squamous cell carcinoma in 9.92% (12/121), and non–small-cell-lung cancer not otherwise specified in 6.61% (8/121) (Table 1).
Table 1
Patient characteristics
Characteristics
n
Mean age, years
58
Sex:
 Male
75
 Female
46
Histopathological subtypes:
 Squamous carcinomas
12
 Adenocarcinoma
101
 Non–small-cell carcinoma NOS
8
Location:
 Supraclavicular lymph nodes
106
 Mediastinal lymph nodes
10
 Axillary lymph nodes
2
 Chest wall
2
 Liver
1
NOS not otherwise specified

Detection of ALK rearrangements

Among the 121 specimens analyzed, 16 that were considered ALK-positive by ICC analysis (with either interpretation system) were then referred for PCR analysis, which confirmed an ALK-positive result in 15 cases. The other 105 cytology specimens that were negative for ALK rearrangement by ICC analysis did not undergo any further molecular analysis of the FNA cytology specimens. However, when the medical records of these 105 patients were reviewed, 33 had results for ALK FISH analysis of formalin-fixed tissue specimens. Among the corresponding 33 ALK ICC-negative specimens, 32 were confirmed as negative by ALK FISH analysis of formalin-fixed tissue, but 1 specimen was found to be ALK-positive.
Altogether, a total of 49 specimens that exhibited either a positive or negative ALK rearrangement status in cytology or tissue specimens were included in the statistical analysis to evaluate the feasibility of ALK ICC testing on ThinPrep slides.

Diagnostic ability of the 2 scoring systems for interpreting ALK ICC results

The binary scoring algorithm for interpreting ALK ICC results detected the expression of ALK protein in 12 of the 121 specimens. Of these, 11 were confirmed as positive for ALK rearrangements by PCR analysis, but 1 proved negative. Five specimens interpreted as ALK-negative by the binary scoring algorithm showed ALK rearrangement on ALK PCR analysis (Table 2). One specimen interpreted as ALK-negative by this interpretation system was ALK-positive on FISH analysis of a tissue specimen (Table 3). Thus, the sensitivity of ALK ICC analysis using the binary scoring algorithm was 68.75% (11/16) and the specificity was 96.97% (32/33). The positive predictive value (PPV) of the test was 91.67% (11/12), and the negative predictive value (NPV) was 86.49% (32/37).
Table 2
Comparison of the results obtained with ALK ICC analysis using the binary scoring algorithm and ALK PCR/FISH analysis
ALK ICC result
ALK PCR/FISH result
Total
Positive
Negative
Positive
11
1
12
Negative
5
32
37
Total
16
33
49
Abbreviations: ALK, anaplastic lymphoma kinase, FISH fluorescence in situ hybridization, ICC immunocytochemistry, IHC immunohistochemistry, RT-PCR reverse-transcription polymerase chain reaction
Table 3
Comparison of the results obtained with ALK ICC analysis using the semiquantified interpretation system and ALK PCR/FISH analysis
ALK ICC result
ALK PCR/FISH result
Total
Positive
Negative
Positive
15
1
16
Negative
1
32
33
Total
16
33
49
Abbreviations: ALK anaplastic lymphoma kinase, FISH fluorescence in situ hybridization, ICC immunocytochemistry, IHC immunohistochemistry, RT-PCR reverse-transcription polymerase chain reaction
With the semiquantified interpretation system, ALK ICC analysis detected ALK protein expression in 16 of the 121 specimens. Of these, 15 were confirmed as positive for ALK rearrangement by ALK PCR analysis, but 1 proved negative. One specimen interpreted as ALK-negative by the semiquantified interpretation system was ALK-positive on FISH analysis of a tissue specimen (Table 3). Thus, the sensitivity, specificity, PPV, and NPV of the semiquantified interpretation system were 93.75% (15/16), 96.97% (32/33), 93.75% (15/16), and 96.97% (32/33), respectively.
When analyzed statistically, the results obtained with the binary scoring algorithm were not significantly different from those obtained with the semiquantified interpretation system (P = 0.125; κ = 0.802), and the sensitivity and specificity of the 2 methods were similar (P = 0.169 and P = 1.000, respectively).

Comparison of the 2 scoring systems for interpreting ALK ICC results

Table 4 shows a comparison of the results obtained with the 2 scoring systems. Among 121 specimens analyzed, there were concordant results with the 2 scoring systems in 117 cases, including 12 positive and 105 negative positive cases; 75% (9/12) of ALK-positive specimens interpreted by the binary scoring algorithm were scored as 3+ by the semiquantified interpretation system, and all were confirmed as positive for ALK rearrangement by PCR analysis (Fig. 2a, b, and, c). One case that was ALK-negative by PCR analysis was interpreted as positive (score 2+) by the 2 interpretation systems (Fig. 2g, h, and i).
Table 4
Correlation of the two scoring systems for ALK ICC analysis
Binary scoring algorithm interpretation
Semiquantified interpretation score
Total
Negative
Positive
0
1+
2+
3+
Positive
0
0
3
9
12
Negative
95
10
4
0
109
Total
95
10
7
9
121
Abbreviations: ALK anaplastic lymphoma kinase, ICC immunocytochemistry
There were 4 discrepant results between the semiquantified interpretation system and the binary scoring algorithm: all were scored as 2+ by the semiquantified interpretation system but negative by the binary scoring algorithm. The ICC staining patterns for these 4 specimens showed intratumoral heterogeneity. A small proportion of the tumor cells (5%-30%) showed moderate staining intensity (score 2+) but the others (70%-95%) showed faint staining intensity (score 1+). Unexpectedly, all were positive for ALK rearrangement on PCR analysis (Fig. 2d, e, and f)

Discussion

The Ventana ALK (D5F3) CDx assay (Ventana Medical Systems Inc., Tucson, AZ, USA) has been approved for screening of ALK rearrangement in China and the US since 2012 and 2015, respectively. This standardized IHC assay has been shown to have between 93% and 100% agreement with the results of FISH analysis when used for screening of ALK rearrangement in clinical practice [6, 7].
Cytology specimens play an important role in the diagnosis of lung cancer, especially for inoperable patients, and may be the only tumor material available for diagnosis and molecular marker analysis in up to 44% of cases [11, 12]. The fixative type is an important consideration when using the Ventana ALK (D5F3) CDx assay on cytology specimens, and the one approved by the FDA is formalin-fixed, paraffin-embedded (FFPE) tissue. Studies have shown that alcohol or methanol fixation may cause the loss or a decrease of antigen immunogenicity [16, 18].
Several studies have performed ALK ICC testing on conventional cytology smears and proved the feasibility of the method. In a study by Tanaka et al.[14], 18 cytology smears obtained by bronchoscopic brushing were examined, and the results of ALK ICC analysis on Papanicolau-stained and alcohol-fixed slides were compared with IHC analysis of FFPE tissues. The ICC and IHC results showed a high concordance rate, and the sensitivity and specificity of the ICC test were 85.7% and 100%, respectively [14]. In another study of ALK ICC analysis on direct cytology smears [10], the cytology specimens were fixed in Delaunay solution. The ALK ICC results were correlated with ALK FISH results on the cytology smears, and the sensitivity and specificity of the ICC test were 93.3% and 96.0%, respectively [10].
Since the approval of ThinPrep slides by the US FDA for processing non-gynecological material in 1991, a growing number of laboratories are processing FNA, bronchial brushing, and effusion specimens with this method [19, 20]. In our laboratory, ThinPrep specimens are the only available cytology material for bronchial brushing and imaging-guided FNA specimens. However, there are no published data on the performance of ALK ICC analysis on ThinPrep slides. ThinPrep slides are methanol pre-fixed and alcohol-fixed cytology specimens, which are different to conventional cytology smears. Consequently, this is the first study of the Ventana ALK (D5F3) CDx assay on ThinPrep slides.
The overall prevalence of ALK rearrangement with this method was 13.22% in our study, which is higher than the rates of 3% to 7% reported in previous studies [35]. We consider that the small sample size takes the major responsibility for this result. However, our results are in line with those of a previous study by our group showing that the prevalence of ALK rearrangement with FISH analysis on cytology specimens was 11.7% [21]. A higher prevalence of ALK rearrangement may be attributed to the presence of advanced disease stages among lung cancer patients who are diagnosed via cytology specimens.
The present study revealed a significant correlation between ALK ICC analysis on ThinPrep slides and ALK PCR/FISH analysis, especially when the semiquantified interpretation system was used. The sensitivity, specificity, PPV, and NPV of the ALK ICC test were 93.75%, 96.97%, 93.75%, and 96.97%, respectively, which are in line with a recent large-scale study of ALK IHC analysis [9]. In this study, 933 FFPE NSCLC tissue specimens were analyzed by both the ALK (D5F3) CDx assay and FISH. The results obtained with the ALK (D5F3) CDx assay were highly concordant with those obtained with the FISH assay, and the PPV and NPV of the ALK (D5F3) CDx assay were 86.0% and 96.3%, respectively.
The results of our study suggest that ALK ICC analysis on ThinPrep slides is a reliable ALK testing method that can be used for identification of patients suitable for treatment with crizotinib, particularly when tissue specimens are not available. An interesting finding was that the binary scoring algorithm recommended by manufacturer did not seem to be as valuable as previously reported [6, 9]. Four ALK-positive specimens that were missed when the binary scoring algorithm was used were positive for ALK rearrangement when the semiquantified interpretation system was used, and all 4 were also positive for ALK rearrangement when tested by PCR. The ICC staining pattern of these 4 cases showed intratumoral heterogeneity and moderate staining intensity, which is not a common phenomenon in ALK IHC based on FFPE tissue in that it often demonstrates diffuse strong tumor tissue staining [6]. As an extreme example, it showed moderate staining in 5% of tumor cells, and faint staining in the other 95% (Fig. 2d, e). However, we believe that the heterogeneity of ALK expression in ICC here is not a real heterogeneous expression. Because in the same sample of PCR detection, their results showed a clear positive, its CT value between 14-20, did not show heterogeneity. As mentioned above, this can mainly be attributed to a loss or decrease of immunogenicity caused by the fixation. For example, in the study of Sauter et al. [18], 13 of the 30 antibodies (43%) in a methanol-fixed cell block failed initial validation using IHC conditions that were established in the study laboratory for FFPE material, but when the IHC protocol was adjusted, immunogenicity was restored for most but not all of the antigens [18]. It is worth conducting a prospective, randomized study that explores the influence of alcohol or methanol fixation in ICC analysis. However,Based on the above data, the semiquantified interpretation system, due to its higher sensitivity, may be preferable for ALK ICC analysis on ThinPrep cytology slides, although there was no statistically significant difference between the 2 scoring systems.
There was one false-positive ALK ICC result in our study. This specimen showed faint staining in 50% of tumor cells and strong staining in another 5%, and was considered positive by both scoring systems (Fig. 2g, h) but negative on RT-PCR. It is well known that PCR analysis of ALK based on several common fusion points (Exon 2, 3, 6, 13, 14, 15, 17, 18 and 20) without including all the variants, leads to a negative result for ALK fusion protein expressed in ICC. Unfortunately, the ALK status of this patient did not have a chance to be confirmed by FISH analysis due to the lack of remaining specimens and non-receipt of treatment with crizotinib.
This is the first report of ALK ICC on ThinPrep slides. Further studies are required to corroborate the results obtained in this study. Furthermore, prospective studies that correlate a positive diagnostic test with patients’ response to treatment are required.

Conclusion

ALK ICC analysis on ThinPrep slides is a reliable testing method for ALK rearrangement. It can be used as a stand-alone test to identify patients suitable for treatment with crizotinib when tissue specimens are not available for ALK analysis. With ALK ICC analysis on ThinPrep slides, the semiquantified interpretation system may be preferable to the binary scoring algorithm, as the test then has higher sensitivity without a reduction of specificity.

Acknowledgements

We thank the patients and all the investigators who participated in the study.

Author contributions

ZZ designed the study and edited the manuscript. HG and JJ drafted the manuscript. HZ and JC performed the FNA and made the cytological diagnoses. LZ, CW and YS performed the ICC. JY and LG performed FISH and IHC. All authors have read and approved the final version of this manuscript.

Funding

This work was supported by the National Natural Science Foundation of China (Grant No. 81641115) and CAMS Innovation Fund for Medical Sciences (2017-I2M-1-006). These funding bodies had no role in the design of the study, the collection, analysis and interpretation of data, or in writing of the manuscript.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
The study protocol was reviewed and approved by the Ethics Committee of the National Cancer Center/Cancer Hospital. All the patients were required to sign an informed consent form explaining the risks of FNA before the FNA examination. At this time, they also gave their informed consent to the present study by signing the paper's informed consent form.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Riely GJ, Marks J, Pao W. KRAS mutations in non-small cell lung cancer. Proc Am Thorac Soc. 2009;6:201–5.CrossRef Riely GJ, Marks J, Pao W. KRAS mutations in non-small cell lung cancer. Proc Am Thorac Soc. 2009;6:201–5.CrossRef
2.
Zurück zum Zitat Solomon BJ, Mok T, Kim DW, et al. First-line crizotinib versus chemotherapy in ALK-positive lung cancer. N Engl J Med. 2014;371:2167–77.CrossRef Solomon BJ, Mok T, Kim DW, et al. First-line crizotinib versus chemotherapy in ALK-positive lung cancer. N Engl J Med. 2014;371:2167–77.CrossRef
3.
Zurück zum Zitat Soda M, Choi YL, Enomoto M. Identification of the transforming EML4-ALK fusion gene in non-small-cell lung cancer. Nature. 2007;448:561–6.CrossRef Soda M, Choi YL, Enomoto M. Identification of the transforming EML4-ALK fusion gene in non-small-cell lung cancer. Nature. 2007;448:561–6.CrossRef
4.
Zurück zum Zitat Takeuchi K, Choi YL, Soda M, et al. Multiplex reverse transcription-PCR screening for EML4-ALK fusion transcripts. Clin Cancer Res. 2008;14:6618–24.CrossRef Takeuchi K, Choi YL, Soda M, et al. Multiplex reverse transcription-PCR screening for EML4-ALK fusion transcripts. Clin Cancer Res. 2008;14:6618–24.CrossRef
5.
Zurück zum Zitat Koivunen JP, Mermel C, Zejnullahu K, et al. EML4-ALK fusion gene and efficacy of an ALK kinase inhibitor in lung cancer. Clin Cancer Res. 2008;14:4275–83.CrossRef Koivunen JP, Mermel C, Zejnullahu K, et al. EML4-ALK fusion gene and efficacy of an ALK kinase inhibitor in lung cancer. Clin Cancer Res. 2008;14:4275–83.CrossRef
6.
Zurück zum Zitat Wynes MW, Sholl LM, Dietel M, et al. An international interpretation study using the ALK IHC antibody D5F3 and a sensitive detection kit demonstrates high concordance between ALK IHC and ALK FISH and between evaluators. J Thorac Oncol. 2014;9:631–8.CrossRef Wynes MW, Sholl LM, Dietel M, et al. An international interpretation study using the ALK IHC antibody D5F3 and a sensitive detection kit demonstrates high concordance between ALK IHC and ALK FISH and between evaluators. J Thorac Oncol. 2014;9:631–8.CrossRef
7.
Zurück zum Zitat Minca EC, Portier BP, Wang Z, et al. ALK status testing in non-small cell lung carcinoma: correlation between ultrasensitive IHC and FISH. J Mol Diagn. 2013;15:341–6.CrossRef Minca EC, Portier BP, Wang Z, et al. ALK status testing in non-small cell lung carcinoma: correlation between ultrasensitive IHC and FISH. J Mol Diagn. 2013;15:341–6.CrossRef
8.
Zurück zum Zitat Conklin CM, Craddock KJ, Have C, et al. Immunohistochemistry is a reliable screening tool for identification of ALK rearrangement in non-small-cell lung carcinoma and is antibody dependent. J Thorac Oncol. 2013;8:45–51.CrossRef Conklin CM, Craddock KJ, Have C, et al. Immunohistochemistry is a reliable screening tool for identification of ALK rearrangement in non-small-cell lung carcinoma and is antibody dependent. J Thorac Oncol. 2013;8:45–51.CrossRef
9.
Zurück zum Zitat Thorne-Nuzzo T, Williams C, Catallini A, et al. A sensitive ALK immunohistochemistry companion diagnostic test identifies patients eligible for treatment with crizotinib. J Thorac Oncol. 2017;12:804–13.CrossRef Thorne-Nuzzo T, Williams C, Catallini A, et al. A sensitive ALK immunohistochemistry companion diagnostic test identifies patients eligible for treatment with crizotinib. J Thorac Oncol. 2017;12:804–13.CrossRef
10.
Zurück zum Zitat Savic S, Bode B, Diebold J, et al. Detection of ALK-positive non-small-cell lung cancers on cytological specimens: high accuracy of immunocytochemistry with the 5A4 clone. J Thorac Oncol. 2013;8:1004–11.CrossRef Savic S, Bode B, Diebold J, et al. Detection of ALK-positive non-small-cell lung cancers on cytological specimens: high accuracy of immunocytochemistry with the 5A4 clone. J Thorac Oncol. 2013;8:1004–11.CrossRef
11.
Zurück zum Zitat Jones AM, Hanson IM, Armstrong GR, et al. Value and accuracy of cytology in addition to histology in the diagnosis of lung cancer at flexible bronchoscopy. Respir Med. 2001;95:374–8.CrossRef Jones AM, Hanson IM, Armstrong GR, et al. Value and accuracy of cytology in addition to histology in the diagnosis of lung cancer at flexible bronchoscopy. Respir Med. 2001;95:374–8.CrossRef
12.
Zurück zum Zitat Savic S, Tapia C, Grilli B, et al. Comprehensive epidermal growth factor receptor gene analysis from cytological specimens of non-small-cell lung cancers. Br J Cancer. 2008;98:154–60.CrossRef Savic S, Tapia C, Grilli B, et al. Comprehensive epidermal growth factor receptor gene analysis from cytological specimens of non-small-cell lung cancers. Br J Cancer. 2008;98:154–60.CrossRef
13.
Zurück zum Zitat Zito MF, Rossi G, Brunelli M, et al. Diagnosis of anaplastic lymphoma kinase rearrangement in cytological samples through a fluorescence in situ hybridization-based assay: Cytological smears versus cell blocks. [J]. Cancer. 2017;125(5):303. Zito MF, Rossi G, Brunelli M, et al. Diagnosis of anaplastic lymphoma kinase rearrangement in cytological samples through a fluorescence in situ hybridization-based assay: Cytological smears versus cell blocks. [J]. Cancer. 2017;125(5):303.
14.
Zurück zum Zitat Knoepp SM, Roh MH. Ancillary techniques on direct-smear aspirate slides: a significant evolution for cytopathology techniques. Cancer Cytopathol. 2013;121:120–8.CrossRef Knoepp SM, Roh MH. Ancillary techniques on direct-smear aspirate slides: a significant evolution for cytopathology techniques. Cancer Cytopathol. 2013;121:120–8.CrossRef
15.
Zurück zum Zitat Tanaka H, Tone K, Hayashi A, et al. Clinical application of immunocytochemical detection of ALK rearrangement on cytology slides for detection or screening of lung adenocarcinoma. Lung Cancer. 2013;80:289–92.CrossRef Tanaka H, Tone K, Hayashi A, et al. Clinical application of immunocytochemical detection of ALK rearrangement on cytology slides for detection or screening of lung adenocarcinoma. Lung Cancer. 2013;80:289–92.CrossRef
16.
Zurück zum Zitat Conde E, Suarez-Gauthier A, Benito A, et al. Accurate identification of ALK positive lung carcinoma patients: novel FDA-cleared automated fluorescence in situ hybridization scanning system and ultrasensitive immunohistochemistry. PLoS One. 2014;9:e107200.CrossRef Conde E, Suarez-Gauthier A, Benito A, et al. Accurate identification of ALK positive lung carcinoma patients: novel FDA-cleared automated fluorescence in situ hybridization scanning system and ultrasensitive immunohistochemistry. PLoS One. 2014;9:e107200.CrossRef
17.
Zurück zum Zitat Guo L, Liu X, Qiu T, et al. In: Bing Z, Xue L, Zhi Z, editors. ALK fusion gene assessment by fully automatic immunohistochemistry in non-smal- cell lung cancer, vol. 43; 2014. p. 95–8. Guo L, Liu X, Qiu T, et al. In: Bing Z, Xue L, Zhi Z, editors. ALK fusion gene assessment by fully automatic immunohistochemistry in non-smal- cell lung cancer, vol. 43; 2014. p. 95–8.
18.
Zurück zum Zitat Sauter JL, Grogg KL, Vrana JA, et al. Young investigator challenge: validation and optimization of immunohistochemistry protocols for use on cellient cell block specimens. Cancer Cytopathol. 2016;124:89–100.CrossRef Sauter JL, Grogg KL, Vrana JA, et al. Young investigator challenge: validation and optimization of immunohistochemistry protocols for use on cellient cell block specimens. Cancer Cytopathol. 2016;124:89–100.CrossRef
19.
Zurück zum Zitat Penín Álvarez M, San Miguel Fraile P, Seoane Cruz I, et al. Needle washing increases the diagnostic yield of fine needle aspiration biopsy of the thyroid gland. Endocrinol Nutr. 2013;60:115–8.CrossRef Penín Álvarez M, San Miguel Fraile P, Seoane Cruz I, et al. Needle washing increases the diagnostic yield of fine needle aspiration biopsy of the thyroid gland. Endocrinol Nutr. 2013;60:115–8.CrossRef
20.
Zurück zum Zitat Minca EC, Lanigan CP, Reynolds JP, et al. ALK status testing in non-small-cell lung carcinoma by FISH on ThinPrep slides with cyology material. J Thorac Oncol. 2014;9:464–8.CrossRef Minca EC, Lanigan CP, Reynolds JP, et al. ALK status testing in non-small-cell lung carcinoma by FISH on ThinPrep slides with cyology material. J Thorac Oncol. 2014;9:464–8.CrossRef
21.
Zurück zum Zitat Li W, Zhang Z, Guo L, et al. Assessment of cytology based molecular analysis to guide targeted therapy in advanced non-small-cell lung cancer. Oncotarget. 2016;7:8332–40.PubMed Li W, Zhang Z, Guo L, et al. Assessment of cytology based molecular analysis to guide targeted therapy in advanced non-small-cell lung cancer. Oncotarget. 2016;7:8332–40.PubMed
Metadaten
Titel
Application of Ventana immunocytochemical analysis on ThinPrep cytology slides for detection of ALK rearrangement in patients with advanced non–small-cell lung cancer
verfasst von
Hui Qin Guo
Jia Jia
Lin Lin Zhao
Huan Zhao
Cong Wang
Yue Sun
Jian Ming Ying
Lei Guo
Jian Cao
Zhi Hui Zhang
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
BMC Cancer / Ausgabe 1/2018
Elektronische ISSN: 1471-2407
DOI
https://doi.org/10.1186/s12885-018-5184-x

Weitere Artikel der Ausgabe 1/2018

BMC Cancer 1/2018 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.