1/R control is a physiological control method of the total artificial heart (TAH) with which long-term survival was obtained with animal experiments. However, 1/R control occasionally diverged in the undulation pump TAH (UPTAH) animal experiment. To improve the control stability of the 1/R control, appropriate control time constant in relation to characteristics of the baroreflex vascular system was investigated with frequency analysis and numerical simulation. In the frequency analysis, data of five goats in which the UPTAH was implanted were analyzed with first Fourier transform technique to examine the vasomotion frequency. The numerical simulation was carried out repeatedly changing baroreflex parameters and control time constant using the elements-expanded Windkessel model. Results of the frequency analysis showed that the 1/R control tended to diverge when very low frequency band that was an indication of the vasomotion frequency was relative high. In numerical simulation, divergence of the 1/R control could be reproduced and the boundary curves between the divergence and convergence of the 1/R control varied depending on the control time constant. These results suggested that the 1/R control tended to be unstable when the TAH recipient had high reflex speed in the baroreflex vascular system. Therefore, the control time constant should be adjusted appropriately with the individual vasomotion frequency.
Literatur
1.
Zurück zum Zitat Hennig E, Grosse-Siestrup C, Krautzberger W, et al. The relationship of cardiac output and venous pressure in long surviving calves with total artificial heart. Trans Am Soc Artif Intern Organs. 1978;24:616–23.PubMed Hennig E, Grosse-Siestrup C, Krautzberger W, et al. The relationship of cardiac output and venous pressure in long surviving calves with total artificial heart. Trans Am Soc Artif Intern Organs. 1978;24:616–23.PubMed
2.
Zurück zum Zitat Takatani S, Harasaki H, Koike S, et al. Optimum control mode for a total artificial heart. Trans Am Soc Artif Intern Organs. 1982;28:148–53.PubMed Takatani S, Harasaki H, Koike S, et al. Optimum control mode for a total artificial heart. Trans Am Soc Artif Intern Organs. 1982;28:148–53.PubMed
3.
Zurück zum Zitat Vasku J. Perspectives of total artificial heart research as a valuable modelling system for general physiology and pathophysiology. In: Akutsu T, Koyanagi H, editors. Heart replacement—artificial heart 4. Tokyo: Springer-Verlag; 1998. p. 161–71. Vasku J. Perspectives of total artificial heart research as a valuable modelling system for general physiology and pathophysiology. In: Akutsu T, Koyanagi H, editors. Heart replacement—artificial heart 4. Tokyo: Springer-Verlag; 1998. p. 161–71.
4.
Zurück zum Zitat Imachi K, Fujimasa I, Omichi H, Mano I, Nishisaka T, Iwai N, Atsumi K. Cardiac output control and blood circulation in artificial heart. Jpn J Artif Organs. 1976;5:321–7. Imachi K, Fujimasa I, Omichi H, Mano I, Nishisaka T, Iwai N, Atsumi K. Cardiac output control and blood circulation in artificial heart. Jpn J Artif Organs. 1976;5:321–7.
5.
Zurück zum Zitat Pierce WS, Landis D, O’Bannon W, Donachy JH, White W, Phillips W, Brighton JA. Automatic control of artificial heart. Trans Am Soc Artif Intern Organs. 1976;22:347–56.PubMed Pierce WS, Landis D, O’Bannon W, Donachy JH, White W, Phillips W, Brighton JA. Automatic control of artificial heart. Trans Am Soc Artif Intern Organs. 1976;22:347–56.PubMed
6.
Zurück zum Zitat Abe Y, Chinzei T, Mabuchi K, Snyder AJ, Isoyama T, Imanishi K, Ymonezawa T, Matsuura H, Kouno A, Ono T, Atsumi K, Fujimasa I, Imachi K. Physiological control of a total artificial heart: conductance- and arterial pressure-based control. J Appl Physiol. 1998;84:868–76.PubMed Abe Y, Chinzei T, Mabuchi K, Snyder AJ, Isoyama T, Imanishi K, Ymonezawa T, Matsuura H, Kouno A, Ono T, Atsumi K, Fujimasa I, Imachi K. Physiological control of a total artificial heart: conductance- and arterial pressure-based control. J Appl Physiol. 1998;84:868–76.PubMed
7.
Zurück zum Zitat Abe Y, Chinzei T, Mabuchi K, Isoyama T, Baba K, Matsuura H, Kouno A, Ono T, Mochizuki S, Sun YP, Imanishi K, Atsumi K, Fujimasa I, Imachi K. Over 500 days survival of a total artificial heart goat with 1/R control. In: Akutsu T, Koyanagi H, editors. Heart replacement—artificial heart 6. Tokyo: Springer-Verlag; 1998. p. 34–40. Abe Y, Chinzei T, Mabuchi K, Isoyama T, Baba K, Matsuura H, Kouno A, Ono T, Mochizuki S, Sun YP, Imanishi K, Atsumi K, Fujimasa I, Imachi K. Over 500 days survival of a total artificial heart goat with 1/R control. In: Akutsu T, Koyanagi H, editors. Heart replacement—artificial heart 6. Tokyo: Springer-Verlag; 1998. p. 34–40.
8.
Zurück zum Zitat Abe Y, Isoyama T, Saito I, Shi W, Inoue Y, Ishii K, Nakagawa H, Ono T, Ono M, Imachi K. Results of animal experiments with the fourth model of the undulation pump total artificial heart. Artif Organs. 2011;35:781–90.CrossRefPubMed Abe Y, Isoyama T, Saito I, Shi W, Inoue Y, Ishii K, Nakagawa H, Ono T, Ono M, Imachi K. Results of animal experiments with the fourth model of the undulation pump total artificial heart. Artif Organs. 2011;35:781–90.CrossRefPubMed
9.
Zurück zum Zitat Ikeda Y, Kawada T, Sugimachi M, Kawaguchi O, Shishido T, Sato T, Miyano H, Matsuura W, Alexander J Jr, Sunagawa K. Neural arc of baroreflex optimizes dynamic pressure regulation in achieving both stability and quickness. Am J Physiol, Heart and Circ Physiol. 1996;271:882–90. Ikeda Y, Kawada T, Sugimachi M, Kawaguchi O, Shishido T, Sato T, Miyano H, Matsuura W, Alexander J Jr, Sunagawa K. Neural arc of baroreflex optimizes dynamic pressure regulation in achieving both stability and quickness. Am J Physiol, Heart and Circ Physiol. 1996;271:882–90.
10.
Zurück zum Zitat Bertram D, Barres C, Cuisinaud G, Julien C. The arterial baroreceptor reflex of the rat exhibits positive feedback properties at the frequency of Mayer waves. J Physiol. 1998;513:251–61.CrossRefPubMedPubMedCentral Bertram D, Barres C, Cuisinaud G, Julien C. The arterial baroreceptor reflex of the rat exhibits positive feedback properties at the frequency of Mayer waves. J Physiol. 1998;513:251–61.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Stergiopulos N, Segers P, Westerhof N. Use of pulse pressure method for estimating total arterial compliance in vivo. Am J Physiol, Heart and Circ Physiol. 1999;276:424–8. Stergiopulos N, Segers P, Westerhof N. Use of pulse pressure method for estimating total arterial compliance in vivo. Am J Physiol, Heart and Circ Physiol. 1999;276:424–8.
12.
Zurück zum Zitat Borst C, Karemaker JM. Time delays in the human baroreceptor reflex. J Auton Nerv Syst. 1983;9:399–409.CrossRefPubMed Borst C, Karemaker JM. Time delays in the human baroreceptor reflex. J Auton Nerv Syst. 1983;9:399–409.CrossRefPubMed
13.
Zurück zum Zitat Gulli G, Cooper VL, Claydon VE, Hainsworth R. Prolonged latency in the baroreflex mediated vascular resistance response in subjects with postural related syncope. Clin Auton Res. 2005;15:207–12.CrossRefPubMed Gulli G, Cooper VL, Claydon VE, Hainsworth R. Prolonged latency in the baroreflex mediated vascular resistance response in subjects with postural related syncope. Clin Auton Res. 2005;15:207–12.CrossRefPubMed
Metadaten
Titel
Appropriate control time constant in relation to characteristics of the baroreflex vascular system in 1/R control of the total artificial heart
verfasst von
Sora Mizuta
Itsuro Saito
Takashi Isoyama
Shintaro Hara
Terumi Yurimoto
Xinyang Li
Haruka Murakami
Toshiya Ono
Kunihiko Mabuchi
Yusuke Abe
Publikationsdatum
17.05.2017
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 3/2017
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-017-0965-6

Weitere Artikel der Ausgabe 3/2017

Journal of Artificial Organs 3/2017 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.