Skip to main content
Erschienen in: Journal of Digital Imaging 6/2010

01.12.2010

Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D–3D Registration

verfasst von: Guoyan Zheng

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 6/2010

Einloggen, um Zugang zu erhalten

Abstract

Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D–3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called “HipMatch.” However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D–3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D–3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D–3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D–3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D–3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
Literatur
1.
Zurück zum Zitat Kiefer H: Differences and opportunities of THA in the USA, Asia and Europe. In: Chang J-D, Billau K Eds. Ceramics in Orthopaedics. Proceedings of the 12th BIOLOX® Symposium on Bioceramics and Alternative Bearings in Joint Arthroplasty, Seoul, Republic of Korea, September 7–8, 2007. Springer, 2007, pp 3–8 Kiefer H: Differences and opportunities of THA in the USA, Asia and Europe. In: Chang J-D, Billau K Eds. Ceramics in Orthopaedics. Proceedings of the 12th BIOLOX® Symposium on Bioceramics and Alternative Bearings in Joint Arthroplasty, Seoul, Republic of Korea, September 7–8, 2007. Springer, 2007, pp 3–8
2.
Zurück zum Zitat Ali Kahn MA, Brakenbury PH, Reynolds IS: Dislocation following total hip replacement. J Bone Jt Surg Br 63B(2):214–218, 1981 Ali Kahn MA, Brakenbury PH, Reynolds IS: Dislocation following total hip replacement. J Bone Jt Surg Br 63B(2):214–218, 1981
3.
Zurück zum Zitat McCollum DE, Gray WJG: Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop 261:159–170, 1990PubMed McCollum DE, Gray WJG: Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop 261:159–170, 1990PubMed
4.
Zurück zum Zitat Sarmiento A, Ebramzadeh E, Gogan WJ, McKellop HA: Cup containment and orientation in cemented total hip arthroplasties. J Bone Jt Surg Br 72B(6):996–1002, 1990 Sarmiento A, Ebramzadeh E, Gogan WJ, McKellop HA: Cup containment and orientation in cemented total hip arthroplasties. J Bone Jt Surg Br 72B(6):996–1002, 1990
5.
Zurück zum Zitat Bader RJ, Steinhauser E, Willmann G, Gradinger R: The effects of implant position, design and wear on the range of motion after total hip arthroplasty. Hip Int 11(2):80–90, 2001 Bader RJ, Steinhauser E, Willmann G, Gradinger R: The effects of implant position, design and wear on the range of motion after total hip arthroplasty. Hip Int 11(2):80–90, 2001
6.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR: Dislocations after total hip-replacement arthroplasties. J Bone Jt Surg Am 60(2):217–220, 1978 Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR: Dislocations after total hip-replacement arthroplasties. J Bone Jt Surg Am 60(2):217–220, 1978
7.
Zurück zum Zitat Thomas T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J: Position of the acetabular cup-accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58:294–300, 2006CrossRef Thomas T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J: Position of the acetabular cup-accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58:294–300, 2006CrossRef
8.
Zurück zum Zitat Marx A, von Knoch M, Pförtner J, Wiese M, Saxler G: Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg 126:487–492, 2006CrossRefPubMed Marx A, von Knoch M, Pförtner J, Wiese M, Saxler G: Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg 126:487–492, 2006CrossRefPubMed
9.
Zurück zum Zitat Pradhan R: Planar anteversion of the acetabular cup as determined from plain nteroposterior radiographs. J Bone Jt Surg Br 81-B:431–435, 1999CrossRef Pradhan R: Planar anteversion of the acetabular cup as determined from plain nteroposterior radiographs. J Bone Jt Surg Br 81-B:431–435, 1999CrossRef
10.
Zurück zum Zitat Della Valle CJ, Kaplan K, Jazrawi A, Ahmed S, Jaffe WL: Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years. J Arthroplasty 19:23–26, 2004CrossRefPubMed Della Valle CJ, Kaplan K, Jazrawi A, Ahmed S, Jaffe WL: Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years. J Arthroplasty 19:23–26, 2004CrossRefPubMed
11.
Zurück zum Zitat Tannast M, Langlotz U, Siebenrock KA, Wiese KM, Bernsmann K, Langlotz F: Anatomical referencing of cup orientation in total hip arthroplasty. Clin Orthop Relat Res 436:144–150, 2005CrossRefPubMed Tannast M, Langlotz U, Siebenrock KA, Wiese KM, Bernsmann K, Langlotz F: Anatomical referencing of cup orientation in total hip arthroplasty. Clin Orthop Relat Res 436:144–150, 2005CrossRefPubMed
12.
Zurück zum Zitat Sellers RG, Lyles D, Dorr LD: The effect of pelvic rotation on alpha and theta angles in total hip arthroplasty. Contemp Orthop 17:67–70, 1988 Sellers RG, Lyles D, Dorr LD: The effect of pelvic rotation on alpha and theta angles in total hip arthroplasty. Contemp Orthop 17:67–70, 1988
13.
Zurück zum Zitat Larose D, Cassenti L, Jaramaz B, Moody JE, Kanade T, DiGioia AM: Post-operative measurement of acetabular cup position using X-ray/CT registration. Proceedings of the 3rd International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2000). LNCS 1935, 2000, pp 1104–1113 Larose D, Cassenti L, Jaramaz B, Moody JE, Kanade T, DiGioia AM: Post-operative measurement of acetabular cup position using X-ray/CT registration. Proceedings of the 3rd International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2000). LNCS 1935, 2000, pp 1104–1113
14.
Zurück zum Zitat Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia III, AM: Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10:37–43, 2005CrossRefPubMed Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia III, AM: Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10:37–43, 2005CrossRefPubMed
15.
Zurück zum Zitat Jaramaz B, Eckman K: 2D/3D registration for measurement of implant alignment after total hip replacement. Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2006), LNCS 4191, 2006, pp 653–661 Jaramaz B, Eckman K: 2D/3D registration for measurement of implant alignment after total hip replacement. Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2006), LNCS 4191, 2006, pp 653–661
16.
Zurück zum Zitat Penney GP, Edwards PJ, Hipwell JH, Slomczykowski M, Revie I, Hawkes DJ: Postoperative calculation of acetabular cup position using 2D–3D registration. IEEE Trans Biomed Eng 54:342–1348, 2007CrossRef Penney GP, Edwards PJ, Hipwell JH, Slomczykowski M, Revie I, Hawkes DJ: Postoperative calculation of acetabular cup position using 2D–3D registration. IEEE Trans Biomed Eng 54:342–1348, 2007CrossRef
17.
Zurück zum Zitat Jaramaz B, DiGioia III, AM, Blackwell M, Nikou C: Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res 354:70–81, 1998CrossRefPubMed Jaramaz B, DiGioia III, AM, Blackwell M, Nikou C: Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res 354:70–81, 1998CrossRefPubMed
18.
Zurück zum Zitat Langlotz U, Grützner PA, Bernsmann K, Kowal J, Tannast M, Caversaccio M, Nolte L-P: Accuracy considerations in navigated cup placement for THR. Proc Inst Mech Eng [H] 221:739–753, 2007 Langlotz U, Grützner PA, Bernsmann K, Kowal J, Tannast M, Caversaccio M, Nolte L-P: Accuracy considerations in navigated cup placement for THR. Proc Inst Mech Eng [H] 221:739–753, 2007
19.
Zurück zum Zitat Zheng G, Steppacher S, Zhang X, Tannast M: Precise estimation of postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. Proceedings of 2007 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI 2007), Part II, LNCS 4792. Springer, 2007, pp 951–959 Zheng G, Steppacher S, Zhang X, Tannast M: Precise estimation of postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. Proceedings of 2007 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI 2007), Part II, LNCS 4792. Springer, 2007, pp 951–959
20.
Zurück zum Zitat Zheng G, Zhang X, Steppacher S, Murphy SB, Siebenrock KA, Tannast M: HipMatch: an object-oriented cross-platform program for accurate determination of cup orientation using 2D–3D registration of single standard X-ray radiograph and a CT volume. Comput Methods Programs Biomed 95:236–248, 2009 doi:10.1016/j.cmpb.2009.02.009 CrossRefPubMed Zheng G, Zhang X, Steppacher S, Murphy SB, Siebenrock KA, Tannast M: HipMatch: an object-oriented cross-platform program for accurate determination of cup orientation using 2D–3D registration of single standard X-ray radiograph and a CT volume. Comput Methods Programs Biomed 95:236–248, 2009 doi:10.​1016/​j.​cmpb.​2009.​02.​009 CrossRefPubMed
21.
Zurück zum Zitat The B: Digital radiographic peroperative planning and postoperative monitoring of total hip replacements—techniques, validation and implementation. Doctoral dissertations, University Medical Center Groningen, The Netherlands, 2006 The B: Digital radiographic peroperative planning and postoperative monitoring of total hip replacements—techniques, validation and implementation. Doctoral dissertations, University Medical Center Groningen, The Netherlands, 2006
22.
Zurück zum Zitat Gao X-S, Hou X-R, Tang J, Cheng H-F: Complete solution classification for the perspective-three-point problem. IEEE Trans Pattern Anal Mach Intell 25:930–943, 2003CrossRef Gao X-S, Hou X-R, Tang J, Cheng H-F: Complete solution classification for the perspective-three-point problem. IEEE Trans Pattern Anal Mach Intell 25:930–943, 2003CrossRef
23.
Zurück zum Zitat Wunsch P, Hirzinger G: Registration of CAD-models to image by iterative inverse perspective matching. Proceedings of the 1996 International Conference on Pattern Recognition (ICPR 1996), 1996, pp 78–83 Wunsch P, Hirzinger G: Registration of CAD-models to image by iterative inverse perspective matching. Proceedings of the 1996 International Conference on Pattern Recognition (ICPR 1996), 1996, pp 78–83
24.
Zurück zum Zitat Joni S, Thévenaz P, Zheng G, Nolte L-P, Unser M: An optimized spline-based registration of a 3D CT to a set of C-Arm images. Int J Biomed Imaging 1–12, 2006 doi:10.1155/IJBI/2006/47197 Joni S, Thévenaz P, Zheng G, Nolte L-P, Unser M: An optimized spline-based registration of a 3D CT to a set of C-Arm images. Int J Biomed Imaging 1–12, 2006 doi:10.​1155/​IJBI/​2006/​47197
25.
Zurück zum Zitat Zheng G, Zhang X, Joni S, Thévenaz P, Unser M, Nolte L-P: Point similarity measures based on MRF modeling of difference images for spline-based 2D-3D rigid registration of X-ray fluoroscopy to CT images. Proceedings of the 3rd International Workshop on Biomedical Image Registration (WBIR 2006), LNCS 4057, 2006, pp 186–194 Zheng G, Zhang X, Joni S, Thévenaz P, Unser M, Nolte L-P: Point similarity measures based on MRF modeling of difference images for spline-based 2D-3D rigid registration of X-ray fluoroscopy to CT images. Proceedings of the 3rd International Workshop on Biomedical Image Registration (WBIR 2006), LNCS 4057, 2006, pp 186–194
26.
Zurück zum Zitat Doolan A, et al: Gonad protection for the antero-posterior projection of the pelvis in diagnostic radiography in Dublin. Radiography 10:15–21, 2004CrossRef Doolan A, et al: Gonad protection for the antero-posterior projection of the pelvis in diagnostic radiography in Dublin. Radiography 10:15–21, 2004CrossRef
27.
Zurück zum Zitat Beckmann J, Lüring C, Tingart M, Aders S, Grifka J, Köck FX: Cup positioning in THA: current status and pitfalls. A systematic evaluation of the literature. Arch Orthop Trauma Surg 1–10, 2008 doi:10.1007/s00402-008-0686-7 Beckmann J, Lüring C, Tingart M, Aders S, Grifka J, Köck FX: Cup positioning in THA: current status and pitfalls. A systematic evaluation of the literature. Arch Orthop Trauma Surg 1–10, 2008 doi:10.​1007/​s00402-008-0686-7
28.
Zurück zum Zitat Lin F, Lim D, Wixson RL, Milos S, Hendrix RW, Makhsous M: Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study. Clin Biomech 23:1004–1011, 2008CrossRef Lin F, Lim D, Wixson RL, Milos S, Hendrix RW, Makhsous M: Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study. Clin Biomech 23:1004–1011, 2008CrossRef
29.
Zurück zum Zitat Langlotz U, Grutzner PA, Bernsmann K, et al: Accuracy considerations in navigated cup placement for total hip arthroplasty. Proc Inst Mech Eng [H] 221:739–753, 2007 Langlotz U, Grutzner PA, Bernsmann K, et al: Accuracy considerations in navigated cup placement for total hip arthroplasty. Proc Inst Mech Eng [H] 221:739–753, 2007
30.
Zurück zum Zitat Zheng G: Statistically deformable 2D/3D registration for accurate determination of post-operative cup orientation from single standard X-ray radiograph. Proceedings of the 12th International Conference on Medical Image Computing and Computer-assisted Intervention (MICCAI 2009). Springer, 2009 (accepted) Zheng G: Statistically deformable 2D/3D registration for accurate determination of post-operative cup orientation from single standard X-ray radiograph. Proceedings of the 12th International Conference on Medical Image Computing and Computer-assisted Intervention (MICCAI 2009). Springer, 2009 (accepted)
31.
Zurück zum Zitat Zheng G, Gonzalez Ballester MA, Styner MA, Nolte L-P: Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and point distribution model. Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2006), vol I, LNCS 4190, 2006, pp 25–32 Zheng G, Gonzalez Ballester MA, Styner MA, Nolte L-P: Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and point distribution model. Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2006), vol I, LNCS 4190, 2006, pp 25–32
32.
Zurück zum Zitat Steppacher S, Moritz T, Zheng G, Zhang X, Kowal J, Suzanne A, Klaus S, Stephen M: Validation of a new method for determination of cup orientation in THA. J Orthop Res, 2009 (in press). doi:10.1002/jor.20929 Steppacher S, Moritz T, Zheng G, Zhang X, Kowal J, Suzanne A, Klaus S, Stephen M: Validation of a new method for determination of cup orientation in THA. J Orthop Res, 2009 (in press). doi:10.​1002/​jor.​20929
Metadaten
Titel
Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D–3D Registration
verfasst von
Guoyan Zheng
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 6/2010
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9226-4

Weitere Artikel der Ausgabe 6/2010

Journal of Digital Imaging 6/2010 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.