Abstract

Background

Assessment of cardiac function is crucial in pediatric patients undergoing cardiovascular surgery, monitoring cardiac output and changing hemodynamic conditions during surgery accordingly is important to improve post-surgical outcome. We aimed to measure cardiac index (CI) and maximal rate of the increase of left ventricular pressure dp/dt(max) with the pressure recording analytic method (PRAM, MostCare®) and compared it with transthoracic echocardiographic cardiac index estimation in infants with transposition of the great arteries (TGA) undergoing surgical correction.

Methods

We enrolled 74 infants with TGA consecutively into this study. CI and dp/dt(max) were measured with PRAM and echocardiography at 0, 4, 8, 12, 24 and 48 h postoperatively. Blood brain natriuretic peptide (BNP) and blood lactate (Lac) were measured at baseline and after operation.

Results

The median age at surgery was 13 days (range 1–25 days) with an average weight of 3.24 kg (range 2.31–4.17 kg). CI estimated by PRAM was 1.11 ± 0.12 L/min/m2 (range 0.69–1.36) and by Doppler echocardiography was 1.13 ± 0.13 L/min/m2 (range 0.76–1.40). dp/dt(max) estimated by PRAM was 1.31 ± 0.03 mmHg/s (range 1.23–1.43) and by Doppler echocardiography was 1.31 ± 0.04 L/min/m2 (range 1.25–1.47). CI (r = 0.817, < 0.001) and dp/dt(max) (r = 0.794, P < 0.001) measured by two methods were highly correlated with a linear relation. Blood BNP and lactate increased to the highest level at 8–12 h post-operatively.

Conclusions

In the early post-operative period, PRAM provides reliable estimates of cardiac index and dp/dt(max) value compared with echocardiographic measurements. PRAM through mostcare® is a reliable continuous monitoring method for peri-operative management in children with congenital heart disease.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high risk surgical patients. Anesth Analg. 2011;112:1392–402.CrossRefPubMed Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high risk surgical patients. Anesth Analg. 2011;112:1392–402.CrossRefPubMed
2.
Zurück zum Zitat Vincent JL, Pelosi P, Pearse R, Payen D, Perel A, Hoeft A, et al. Perioperative cardiovascular monitoring of high—risk patients: a consensus of 12. Crit Care. 2015;19:224–36.CrossRefPubMedPubMedCentral Vincent JL, Pelosi P, Pearse R, Payen D, Perel A, Hoeft A, et al. Perioperative cardiovascular monitoring of high—risk patients: a consensus of 12. Crit Care. 2015;19:224–36.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Thompson AE. Pulmonary artery catheterization in children. New Horiz. 1997;5:244–50.PubMed Thompson AE. Pulmonary artery catheterization in children. New Horiz. 1997;5:244–50.PubMed
4.
Zurück zum Zitat Romano SM, Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med. 2002;30:1834–41.CrossRefPubMed Romano SM, Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med. 2002;30:1834–41.CrossRefPubMed
5.
Zurück zum Zitat Garisto C, Favia I, Ricci Z, Romagnoli S, Haiberger R, Polito A, et al. Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery. Paediatr Anaesth. 2014;2:143–9. Garisto C, Favia I, Ricci Z, Romagnoli S, Haiberger R, Polito A, et al. Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery. Paediatr Anaesth. 2014;2:143–9.
6.
Zurück zum Zitat Scolletta S, Bodson L, Donadello K, Taccone FS, Devigili A, Vincent JL, et al. Assessment of left ventricular function by pulse wave analysis in critically ill patients. Intensive Care Med. 2013;39:1025–33.CrossRefPubMed Scolletta S, Bodson L, Donadello K, Taccone FS, Devigili A, Vincent JL, et al. Assessment of left ventricular function by pulse wave analysis in critically ill patients. Intensive Care Med. 2013;39:1025–33.CrossRefPubMed
8.
Zurück zum Zitat Calamandrei M, Mirabile L, Muschetta S, Gensini GF, De Simone L, Romano SM. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography. Pediatr Crit Care Med. 2008;9:310–2.CrossRefPubMed Calamandrei M, Mirabile L, Muschetta S, Gensini GF, De Simone L, Romano SM. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography. Pediatr Crit Care Med. 2008;9:310–2.CrossRefPubMed
9.
Zurück zum Zitat Giomarelli P, Biagioli B, Scolletta S. Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg. 2004;26:515–20.CrossRefPubMed Giomarelli P, Biagioli B, Scolletta S. Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg. 2004;26:515–20.CrossRefPubMed
10.
Zurück zum Zitat Lipshultz SE, Miller TL. Establishing norms for echocardiographic measurements of cardiovascular structures and function in children. J Appl Physiol. 1985;2005:386–8. Lipshultz SE, Miller TL. Establishing norms for echocardiographic measurements of cardiovascular structures and function in children. J Appl Physiol. 1985;2005:386–8.
11.
Zurück zum Zitat Yingchoncharoen T, Agarwal S, Popovic ZB, Marwick TH. Normal ranges of left ventricular strain: a meta-analysis. J Am Soc Echocardiogr. 2013;26:185–91.CrossRefPubMed Yingchoncharoen T, Agarwal S, Popovic ZB, Marwick TH. Normal ranges of left ventricular strain: a meta-analysis. J Am Soc Echocardiogr. 2013;26:185–91.CrossRefPubMed
12.
Zurück zum Zitat Gottdiener JS, Bednarz J, Devereux R, Gardin J, Klein A, Manning WJ, et al. American Society of Echocardiography recommendations for use of echocardiography in clinical trials. J Am Soc Echocardiogr. 2004;17:1086–119.PubMed Gottdiener JS, Bednarz J, Devereux R, Gardin J, Klein A, Manning WJ, et al. American Society of Echocardiography recommendations for use of echocardiography in clinical trials. J Am Soc Echocardiogr. 2004;17:1086–119.PubMed
13.
Zurück zum Zitat Labovitz AJ, Buckingham TA, Habermehl K, Nelson J, Kennedy HL, Williams GA, et al. The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output. Am Heart J. 1985;109:327–32.CrossRefPubMed Labovitz AJ, Buckingham TA, Habermehl K, Nelson J, Kennedy HL, Williams GA, et al. The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output. Am Heart J. 1985;109:327–32.CrossRefPubMed
14.
Zurück zum Zitat DuBourg O, Jondeau G, Beauchet A, Hardy A, Bourdarias JP. Doppler-derived aortic maximal acceleration: a reliable index of left ventricular systolic function. Chest. 1993;103:1064–7.CrossRefPubMed DuBourg O, Jondeau G, Beauchet A, Hardy A, Bourdarias JP. Doppler-derived aortic maximal acceleration: a reliable index of left ventricular systolic function. Chest. 1993;103:1064–7.CrossRefPubMed
15.
Zurück zum Zitat Michalak KW, Moll JA, Moll M, Dryzek P, Moszura T, Kopala M, et al. The neoaortic root in children with transposition of the great arteries after an arterial switch operation. Eur J Cardiothorac Surg. 2013;43:1101–8.CrossRefPubMed Michalak KW, Moll JA, Moll M, Dryzek P, Moszura T, Kopala M, et al. The neoaortic root in children with transposition of the great arteries after an arterial switch operation. Eur J Cardiothorac Surg. 2013;43:1101–8.CrossRefPubMed
16.
Zurück zum Zitat Chew MS, Poelaert J. Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature. Intensive Care Med. 2003;29:1889–94.CrossRefPubMed Chew MS, Poelaert J. Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature. Intensive Care Med. 2003;29:1889–94.CrossRefPubMed
17.
Zurück zum Zitat Sangkum L, Liu GL, Yu L, Yan H, Kaye AD, Liu H. Minimally invasive of noninvasive cardiac output measurement: an update. J Anesth. 2016;30:461–80.CrossRefPubMed Sangkum L, Liu GL, Yu L, Yan H, Kaye AD, Liu H. Minimally invasive of noninvasive cardiac output measurement: an update. J Anesth. 2016;30:461–80.CrossRefPubMed
18.
Zurück zum Zitat Marik PE. Noninvasive cardiac output monitors: a state-of the art review. J Cardiothorac Vasc Anesth. 2013;27:121–34.CrossRefPubMed Marik PE. Noninvasive cardiac output monitors: a state-of the art review. J Cardiothorac Vasc Anesth. 2013;27:121–34.CrossRefPubMed
19.
Zurück zum Zitat Pittman J, Bar-Yosef S, SumPing J, Sherwood M, Mark J. Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med. 2005;33:2015–21.CrossRefPubMed Pittman J, Bar-Yosef S, SumPing J, Sherwood M, Mark J. Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med. 2005;33:2015–21.CrossRefPubMed
20.
Zurück zum Zitat Mellander M, Sabel KG, Caidahl K, Solymar L, Eriksson B. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol. 1987;8:241–6.CrossRefPubMed Mellander M, Sabel KG, Caidahl K, Solymar L, Eriksson B. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol. 1987;8:241–6.CrossRefPubMed
21.
Zurück zum Zitat Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W Jr, et al. Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr. 1982;101:46–50.CrossRefPubMed Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W Jr, et al. Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr. 1982;101:46–50.CrossRefPubMed
22.
Zurück zum Zitat Mandelbaum-Isken VH, Linderkamp O. Cardiac output by pulsed Doppler in neonates using the apical window. Pediatr Cardiol. 1991;12:13–6.CrossRefPubMed Mandelbaum-Isken VH, Linderkamp O. Cardiac output by pulsed Doppler in neonates using the apical window. Pediatr Cardiol. 1991;12:13–6.CrossRefPubMed
Metadaten
Titel
Assessment of cardiac function in infants with transposition of the great arteries after surgery: comparison of two methods
verfasst von
Fan Yang
Roberta Iacobelli
Jian-Ming Wang
Fiore Salvatore Iorio
Publikationsdatum
30.07.2018
Verlag
Childrens Hospital, Zhejiang University School of Medicine
Erschienen in
World Journal of Pediatrics / Ausgabe 4/2018
Print ISSN: 1708-8569
Elektronische ISSN: 1867-0687
DOI
https://doi.org/10.1007/s12519-018-0178-y

Weitere Artikel der Ausgabe 4/2018

World Journal of Pediatrics 4/2018 Zur Ausgabe

Update Pädiatrie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.