Abstract

Purpose

A variety of statistical models based on overnight oximetry has been proposed to simplify the detection of children with suspected obstructive sleep apnea syndrome (OSAS). Despite the usefulness reported, additional thorough comparative analyses are required. This study was aimed at assessing common binary classification models from oximetry for the detection of childhood OSAS.

Methods

Overnight oximetry recordings from 176 children referred for clinical suspicion of OSAS were acquired during in-lab polysomnography. Several training and test datasets were randomly composed by means of bootstrapping for model optimization and independent validation. For every child, blood oxygen saturation (SpO2) was parameterized by means of 17 features. Fast correlation-based filter (FCBF) was applied to search for the optimum features. The discriminatory power of three statistical pattern recognition algorithms was assessed: linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), and logistic regression (LR). The performance of each automated model was evaluated for the three common diagnostic polysomnographic cutoffs in pediatric OSAS: 1, 3, and 5 events/h.

Results

Best screening performances emerged using the 1 event/h cutoff for mild-to-severe childhood OSAS. LR achieved 84.3% accuracy (95% CI 76.8–91.5%) and 0.89 AUC (95% CI 0.83–0.94), while QDA reached 96.5% PPV (95% CI 90.3–100%) and 0.91 AUC (95% CI 0.85–0.96%). Moreover, LR and QDA reached diagnostic accuracies of 82.7% (95% CI 75.0–89.6%) and 82.1% (95% CI 73.8–89.5%) for a cutoff of 5 events/h, respectively.

Conclusions

Automated analysis of overnight oximetry may be used to develop reliable as well as accurate screening tools for childhood OSAS.
Literatur
4.
Zurück zum Zitat Kheirandish-Gozal L (2010) What is “abnormal” in pediatric sleep? Respir Care 55:1366–1376PubMed Kheirandish-Gozal L (2010) What is “abnormal” in pediatric sleep? Respir Care 55:1366–1376PubMed
8.
Zurück zum Zitat Alonso-Álvarez ML, Terán-Santos J, Ordax-Carbajo E et al (2015) Reliability of home respiratory polygraphy for the diagnosis of sleep apnea in children. Chest 147:1020–1028CrossRefPubMed Alonso-Álvarez ML, Terán-Santos J, Ordax-Carbajo E et al (2015) Reliability of home respiratory polygraphy for the diagnosis of sleep apnea in children. Chest 147:1020–1028CrossRefPubMed
9.
Zurück zum Zitat Garde A, Dehkordi P, Karlen W et al (2014) Development of a screening tool for sleep disordered breathing in children using the phone OximeterTM. PLoS One 9:e112959CrossRefPubMedPubMedCentral Garde A, Dehkordi P, Karlen W et al (2014) Development of a screening tool for sleep disordered breathing in children using the phone OximeterTM. PLoS One 9:e112959CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Cohen G, de Chazal P (2013) Automated detection of sleep apnea in infants using minimally invasive sensors. In: Proceedings of the 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE-EMBC), 3–7 July 2013, Osaka (Japan), pp 1652–1655. https://doi.org/10.1109/EMBC.2013.6609834 Cohen G, de Chazal P (2013) Automated detection of sleep apnea in infants using minimally invasive sensors. In: Proceedings of the 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE-EMBC), 3–7 July 2013, Osaka (Japan), pp 1652–1655. https://​doi.​org/​10.​1109/​EMBC.​2013.​6609834
14.
Zurück zum Zitat Álvarez D, Alonso-Álvarez ML, Gutiérrez-Tobal GC, Crespo A, Kheirandish-Gozal L, Hornero R, Gozal D, Terán-Santos J, del Campo F (2017) Automated screening of children with obstructive sleep apnea using nocturnal oximetry: an alternative to respiratory polygraphy in unattended settings. J Clin Sleep Med 13(05):693–702. https://doi.org/10.5664/jcsm.6586 CrossRefPubMedPubMedCentral Álvarez D, Alonso-Álvarez ML, Gutiérrez-Tobal GC, Crespo A, Kheirandish-Gozal L, Hornero R, Gozal D, Terán-Santos J, del Campo F (2017) Automated screening of children with obstructive sleep apnea using nocturnal oximetry: an alternative to respiratory polygraphy in unattended settings. J Clin Sleep Med 13(05):693–702. https://​doi.​org/​10.​5664/​jcsm.​6586 CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Hornero R, Kheirandish-Gozal L, Gutiérrez-Tobal GC et al (2017) Nocturnal oximetry-based evaluation of habitually snoring children. Am J Respir Crit Care Med 196:1591–1598CrossRefPubMedPubMedCentral Hornero R, Kheirandish-Gozal L, Gutiérrez-Tobal GC et al (2017) Nocturnal oximetry-based evaluation of habitually snoring children. Am J Respir Crit Care Med 196:1591–1598CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Gil E, Bailón R, Vergara JM et al (2010) PTT variability for discrimination of sleep apnea related decreases in the amplitude fluctuations of PPG signal in children. IEEE Trans Biomed Eng 57:1079–1088CrossRefPubMed Gil E, Bailón R, Vergara JM et al (2010) PTT variability for discrimination of sleep apnea related decreases in the amplitude fluctuations of PPG signal in children. IEEE Trans Biomed Eng 57:1079–1088CrossRefPubMed
17.
Zurück zum Zitat Lázaro J, Gil E, Vergara JM et al (2014) Pulse rate variability analysis for discrimination of sleep-apnea-related decreases in the amplitude fluctuations of pulse photoplethysmographic signal in children. IEEE J Biomed Health Inform 18:240–246CrossRefPubMed Lázaro J, Gil E, Vergara JM et al (2014) Pulse rate variability analysis for discrimination of sleep-apnea-related decreases in the amplitude fluctuations of pulse photoplethysmographic signal in children. IEEE J Biomed Health Inform 18:240–246CrossRefPubMed
19.
Zurück zum Zitat Gutiérrez-Tobal GC, Alonso-Álvarez ML, Álvarez D, del Campo F, Terán-Santos J, Hornero R (2015) Diagnosis of pediatric obstructive sleep apnea: preliminary findings using automatic analysis of airflow and oximetry recordings obtained at patients’ home. Biomed Signal Process Control 18:401–407. https://doi.org/10.1016/j.bspc.2015.02.014 CrossRef Gutiérrez-Tobal GC, Alonso-Álvarez ML, Álvarez D, del Campo F, Terán-Santos J, Hornero R (2015) Diagnosis of pediatric obstructive sleep apnea: preliminary findings using automatic analysis of airflow and oximetry recordings obtained at patients’ home. Biomed Signal Process Control 18:401–407. https://​doi.​org/​10.​1016/​j.​bspc.​2015.​02.​014 CrossRef
23.
Zurück zum Zitat Berry RB, Budhiraja R, Gottlieb DJ, et al for the American Academy of Sleep Medicine (2012). Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations Sleep Apnea Definitions Task Force Am Academy Sleep Medicine J Clin Sleep Med 8:597–619 Berry RB, Budhiraja R, Gottlieb DJ, et al for the American Academy of Sleep Medicine (2012). Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations Sleep Apnea Definitions Task Force Am Academy Sleep Medicine J Clin Sleep Med 8:597–619
24.
Zurück zum Zitat Álvarez D, Hornero R, Marcos JV et al (2013) Assessment of feature selection and classification approaches to enhance information from overnight oximetry in the context of sleep apnea diagnosis. Int J Neural Syst 23:e13520CrossRef Álvarez D, Hornero R, Marcos JV et al (2013) Assessment of feature selection and classification approaches to enhance information from overnight oximetry in the context of sleep apnea diagnosis. Int J Neural Syst 23:e13520CrossRef
25.
Zurück zum Zitat Alvarez D, Gutiérrez-Tobal GC, Alonso-Álvarez ML, et al (2014) Análisis espectral y no lineal de la señal de oximetría domiciliaria en la ayuda al diagnóstico de la apnea infantil. In proc 32th Annu Nac Conf Spanish Biomedical Engineering Society, Barcelona (Spain), pp 1–4 Alvarez D, Gutiérrez-Tobal GC, Alonso-Álvarez ML, et al (2014) Análisis espectral y no lineal de la señal de oximetría domiciliaria en la ayuda al diagnóstico de la apnea infantil. In proc 32th Annu Nac Conf Spanish Biomedical Engineering Society, Barcelona (Spain), pp 1–4
26.
Zurück zum Zitat Álvarez D, Hornero R, Marcos JV et al (2010) Multivariate analysis of blood oxygen saturation recordings in obstructive sleep apnea diagnosis. IEEE Trans Biomed Eng 57:2816–2824CrossRefPubMed Álvarez D, Hornero R, Marcos JV et al (2010) Multivariate analysis of blood oxygen saturation recordings in obstructive sleep apnea diagnosis. IEEE Trans Biomed Eng 57:2816–2824CrossRefPubMed
27.
Zurück zum Zitat Gutiérrez-Tobal GC, Álvarez D, Marcos JV et al (2013) Pattern recognition in airflow recordings to assist in the sleep apnoea–hypopnoea syndrome diagnosis. Med Biol Eng Comput 51:1367–1380CrossRefPubMed Gutiérrez-Tobal GC, Álvarez D, Marcos JV et al (2013) Pattern recognition in airflow recordings to assist in the sleep apnoea–hypopnoea syndrome diagnosis. Med Biol Eng Comput 51:1367–1380CrossRefPubMed
28.
Zurück zum Zitat Yu L, Liu H (2004) Efficient feature selection via analysis of relevance and redundancy. J Mach Learn Res 5:1205–1224 Yu L, Liu H (2004) Efficient feature selection via analysis of relevance and redundancy. J Mach Learn Res 5:1205–1224
29.
Zurück zum Zitat Crespo A, Álvarez D, Gutiérrez-Tobal GC et al (2017) Multiscale entropy analysis of unattended oximetric recordings to assist in the screening of paediatric sleep apnoea at home. Entropy 19:284CrossRef Crespo A, Álvarez D, Gutiérrez-Tobal GC et al (2017) Multiscale entropy analysis of unattended oximetric recordings to assist in the screening of paediatric sleep apnoea at home. Entropy 19:284CrossRef
30.
Zurück zum Zitat Bishop CM (2006) Pattern recognition and machine learning. Springer, New York Bishop CM (2006) Pattern recognition and machine learning. Springer, New York
31.
Zurück zum Zitat Witten IH, Frank E, Hall MA (2011) Data mining practical machine learning tools and techniques. Burlington, Morgan Kaufmann/Elsevier Witten IH, Frank E, Hall MA (2011) Data mining practical machine learning tools and techniques. Burlington, Morgan Kaufmann/Elsevier
32.
Zurück zum Zitat Kaditis A, Kheirandish-Gozal L, Gozal D (2016) Pediatric OSAS: oximetry can provide answers when polysomnography is not available. Sleep Med Rev 27:96–105CrossRefPubMed Kaditis A, Kheirandish-Gozal L, Gozal D (2016) Pediatric OSAS: oximetry can provide answers when polysomnography is not available. Sleep Med Rev 27:96–105CrossRefPubMed
Metadaten
Titel
Assessment of oximetry-based statistical classifiers as simplified screening tools in the management of childhood obstructive sleep apnea
verfasst von
Andrea Crespo
Daniel Álvarez
Leila Kheirandish-Gozal
Gonzalo C. Gutiérrez-Tobal
Ana Cerezo-Hernández
David Gozal
Roberto Hornero
Félix del Campo
Publikationsdatum
16.02.2018
Verlag
Springer International Publishing
Erschienen in
Sleep and Breathing / Ausgabe 4/2018
Print ISSN: 1520-9512
Elektronische ISSN: 1522-1709
DOI
https://doi.org/10.1007/s11325-018-1637-3

Weitere Artikel der Ausgabe 4/2018

Sleep and Breathing 4/2018 Zur Ausgabe

Sleep Breathing Physiology and Disorders • Review

Effect of CPAP therapy on liver disease in patients with OSA: a review

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.