Skip to main content
Erschienen in: International Journal of Legal Medicine 1/2019

Open Access 29.03.2018 | Original Article

Assessment of polyurethane spheres as surrogates for military ballistic head injury

verfasst von: Peter Mahoney, Debra Carr, Nicholas Hunt, Russ J Delaney

Erschienen in: International Journal of Legal Medicine | Ausgabe 1/2019

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

SYNBONE® spheres were impacted with 7.62 × 39 mm mild steel core ammunition at a mean impact velocity of 654 m/s, SD 7 m/s, to simulate engagement distances of around 50–100 m. The wounds and fracture patterns were assessed by two forensic pathologists familiar with military cranial injury. The overall fracture pattern was assessed as being too comminuted when compared with actual injury. This suggests the SYNBONE® spheres have less utility for simulating military injury than other purposes described in the literature.

Introduction

The aim of this project was to assess if SYNBONE® spheres (SYNBONE AG, Neugutstrasse 4, 7208 Malans, Switzerland) are suitable for simulating military ballistic head injury at engagement distances of 50 to 100 m.
Much of the ground work in simulating cranial gunshot injury with synthetic models has been done by Thali and colleagues [13]. In his initial paper [1], Thali expresses concern that the physical mechanisms behind ballistic trauma are poorly understood. To address this, the group built a synthetic head model using a layered polyurethane sphere (to simulate bone structure), a latex periosteum and a silicone cap to substitute for the scalp. Ten percent gelatine at 4 °C was used as a ‘brain’ fill. The model was shot with a broad range of ammunition (including 7.62 × 51 mm and 7.62 × 39 mm, but mainly 9 × 19 mm full metal jacket, FMJ, Luger) from 10 m and the authors concluded that the injuries created in the model were fully comparable to those seen in real incidents.
Further work with this model included impacting it with 9 mm Luger bullets to explore the underlying mechanisms for entrance wound characteristics [2] and a study of tangential gunshot head injury [3]. In the latter study, the bullets were fired directly at the synthetic skull with the latex periosteum layer (but not the silicone scalp) and found to produce realistic tangential injury and fracture patterns.
More recent work by Taylor and Kranioti has used SYNBONE® spheres to investigate execution style gunshot injuries [4]. The gelatine-filled models were shot at a range of 30 cm with seven different handgun ammunitions with the aim of detecting similarities and differences in wound characteristics for use in future investigations. The authors provide examples of two clinical cases (shot with 0.22LR and 0.45 ACP ammunition) that closely match the corresponding models.
Smith et al. [5] carried out a detailed analysis of the differences between injuries inflicted on a real bone compared to polyurethane bone substitutes. They used both flat plates of synthetic bone (5 mm thick) and spheres (5 and 7 mm wall thickness), and impacted them with a crossbow bolt, a ball fired from a black powder musket, and modern rifle ammunition (0.243″ Winchester Soft Point, velocity 905 m/s, and 7.62 × 51 mm NATO FMJ, velocity 853 m/s). The weapons were fired from a 2 m distance at the targets. They initially compared impacts on flat plates and empty spheres to see if the different shapes affected the response to impact, and compared these with shots into cattle scapulae. There were no gross differences between flat plates and spheres; both showed internal bevelling at the entry site. Differences between the synthetic and real bone are considered later in this paper.
Subsequent work involved spheres filled with 10% gelatine at 4 °C. The secondary and tertiary fracture patterns produced by modern firearms were generally consistent with those seen in published examples of real cranial trauma [5].

Method

Nine SYNBONE® spheres (190 mm diameter, 6 mm wall thickness, thin rubber skin covering outer surface) were filled with ballistic gelatine of either 5,7, or 10% by mass (Fig. 1a). The gelatine was allowed to set at around 17 °C for 24 h. Other work by our group has shown no difference in fracture patterns in a skull model when impacted at a series of temperatures from 4 to 25 °C [6] and no difference with the above gelatine % fills.
The models were taken to the Small Arms Experimental Range, Cranfield University, Defence Academy of the UK (Fig. 1b), and placed 10 m from a no 3 Enfield proof mount fitted with an accurate barrel and shot with 7.62 × 39 mm Ukrainian mild steel core (MSC) ammunition (Soviet State Factory, Lugansk, manufactured 1967; mean impact velocity 654 m/s, SD 7 m/s). The ammunition was downloaded to achieve these velocities simulating engagement distances of around 50–100 m) [7].
Bullet velocity was tracked using a Weibel Doppler (Fig. 1c) and impacts filmed using two Phantom high-speed cameras (V12 from above, sample rate 20,000 frames per second, exposure time 5 μs, resolution 512 × 480; V1212 from the side, sample rate 34,000 frames per second, exposure time 10 μs, resolution 640 × 480).
Models 1–3 were each shot twice to assess their suitability for simulating more than one gunshot injury and assessing if the order of shot impact could be determined as described by Thali [1]. Models 4–9 were each shot once to assess entry and exit fracture patterns from one impact sequence.
The condition of the models in situ post-impact was captured using a Nikon D3200 DSLR camera fitted with an AF-S NIKKOR 18–55 mm lens.
The nine models were then examined by two Home Office forensic pathologists with extensive experience of assessing ballistic injury. The pathologists were invited to score the entry wound, exit wound, and overall fracture pattern using a 4-point Likert-type scale [8] (where 4 = exactly like a real injury, 3 = a lot like a real injury, 2 = a bit like a real injury and 1 = nothing like a real injury) and provide comment as needed. The scores are summarised in Table 1.
Table 1
Score of the entry wound, exit wound, and overall fracture pattern using a 4-point Likert-type scale
Model
% gelatine fill
Assessor
Entry wound
Exit wound
Overall fracture pattern
1
10
(a)
2
2
2
  
(b)
2
2
2
2
10
(a)
1
2
1
  
(b)
1
2
1
3
10
(a)
2
2
2
  
(b)
1
2
2
4
7
(a)
1
1
1
  
(b)
1
2
1
5
7
(a)
1
1
1
  
(b)
1
2
1
6
7
(a)
1
2
1
  
(b)
1
2
1
7
5
(a)
1
2
1
  
(b)
1
2
1
8
5
(a)
1
2
2
  
(b)
1
2
1
9
5
(a)
1
2
1
  
(b)
1
2
1

Results

High-speed videos (HSV)

Example impact sequences taken from the high-speed cameras are shown in Figs. 2, 3, and 4. All HSV triggered and captured the impacts except the V1212 side view for model 4; the overhead view was recorded.
There were two distinct series of events. For models 1, 3, 6, and 8 and the first shot into model 2, the fractures developed as illustrated in Figs. 2 and 3. Fractures spread from both the entry and exit sites but the main fragments were drawn back together by the extendable latex ‘periosteum’. With models 4, 5, 7, 9 and the second shot into model 2, the sphere ruptured and the gelatine fill was expelled (Fig. 4), imitating the ‘Krönlein shot’ [9]. From review of the high-speed videos, the impact sites are not obviously different in the two groups and bullets can be seen to have yawed within the material and exited sideways (Figs. 2b and4b) in an example from each group, although the fractures are more extensive and the integrity of the sphere lost in the models where the contents are completely expelled.
There were also no obvious differences in the fracture patterns seen on the HSV when the spheres with the different gelatine concentrations were compared.

Pathologist assessment

From Table 1, it can be seen that the most of the entry wounds only scored 1. Although the entry sites displayed bullet wipe and six models had internal beveling, the overall view was that they were too fractured when compared with real incidents and not realistic. The assessors were able to distinguish the different impacts in models 1–3 (model 3 was noted to have a good example of a key hole injury pattern from the second bullet impact) and the order in which they had occurred from the intersecting fracture lines.
The exit wounds scored marginally better but the overall view was that they were too comminuted. External beveling was found in three models (3, 7, and 9), but in others, the exit elements were so fragmented that this could not be assessed.
The overall fracture patterns were judged as being too comminuted when compared with actual military head injury.
The pathologists also noted that differences in bone thickness and the structure within skulls and anatomically correct models does influence fracture patterns as discussed by Fenton et al. [10].

Discussion

SYNBONE® spheres have been successfully used to simulate ballistic injury by a number of authors. Smith [5] found that the models produced different fracture patterns when impacted by the three projectile types described above, and the black powder carbine did produce a realistic key hole defect from a tangential impact, similar to that described by Thali [3]. Taylor and Kranioti [4] noted differences in the entry wound characteristics between the ammunition types tested with ‘entrance wound radius ...positively correlated with the caliber dimension’ and ‘the number of radiating and concentric fractures is also increasing with the caliber dimension’ [4].
There have been a number of observations regarding how the models differ from real injury. Smith [5] noted that the exit fracture patterns were different from real bone and described ‘stepped fractures where the radius of defect varied widely forming jagged corners around margins, unlike usually rounded/ovoid shapes in real bone’.
Taylor and Kranioti [4] also noted that the exit wounds in their model were larger than real injury.
The eviscerating injury seen in Fig. 4 was first described by the Swiss Surgeon Rudolf Ulrich Krönlein in relation to close range gunshots with the 1889 Swiss repeating rifle [9]. This effect was also seen by Thali et al. [1].
Our experience using 7.62 × 39 mm ammunition at simulated engagement ranges is that the bony injuries produced in our models were too comminuted and fractured in comparison with contemporary military bony injuries reviewed by the pathologists. This suggests that the model has less utility for this purpose than when used in the tests described by others [15]. Of note, two of the 10% gelatine fill spheres had marginally higher scores when compared with the other fills, although the number of replicates for each experiment is small.

Conclusion

SYNBONE® spheres were assessed for their suitability in simulating military ballistic head injury at engagement distances of 50 to 100 m. Although the overall number of replicates was low (n = 9), the impression was that the fractures produced were too comminuted when compared with recent military injury. Further work is ongoing to assess other materials for replicating these injuries.

Caveats

This experiment only used one ammunition type simulating a particular engagement range. Different results may be obtained with other ammunition and impact velocities.

Acknowledgements

The authors are grateful to David Miller and Michael Teagle from the Small Arms Experimental Range, Cranfield University, Defence Academy of the United Kingdom, Shrivenham, SN6 8LA.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Literatur
1.
Zurück zum Zitat Thali MJ, Kneubuehl BP, Zollinger U, Dirnhofer R (2002) The ‘Skin-skull-brain model’: a new instrument for the study of gunshot effects. Forensic Sci Int 125(2–3):178–189CrossRefPubMed Thali MJ, Kneubuehl BP, Zollinger U, Dirnhofer R (2002) The ‘Skin-skull-brain model’: a new instrument for the study of gunshot effects. Forensic Sci Int 125(2–3):178–189CrossRefPubMed
2.
Zurück zum Zitat Thali MJ, Kneubuehl BP, Zollinger U, Dirnhofer R (2002) A study of the morphology of gunshot entry wounds in connection with their dynamic creation, utilizing the ‘skin-skull-brain model’. Forensic Sci Int 125:190–194CrossRefPubMed Thali MJ, Kneubuehl BP, Zollinger U, Dirnhofer R (2002) A study of the morphology of gunshot entry wounds in connection with their dynamic creation, utilizing the ‘skin-skull-brain model’. Forensic Sci Int 125:190–194CrossRefPubMed
3.
Zurück zum Zitat Thali MJ, Kneubuehl BP, Zollinger U, Dirnhofer R (2003) A high-speed study of the dynamic bullet-body interactions produced by grazing gunshots with full metal jacketed and lead projectiles. Forensic Sci Int 132:93–98CrossRefPubMed Thali MJ, Kneubuehl BP, Zollinger U, Dirnhofer R (2003) A high-speed study of the dynamic bullet-body interactions produced by grazing gunshots with full metal jacketed and lead projectiles. Forensic Sci Int 132:93–98CrossRefPubMed
4.
Zurück zum Zitat Taylor SC, Kranioti EF (2018) Cranial trauma in handgun executions: Experimental data using polyurethane proxies. Forensic Sci Int 282:157–167CrossRefPubMed Taylor SC, Kranioti EF (2018) Cranial trauma in handgun executions: Experimental data using polyurethane proxies. Forensic Sci Int 282:157–167CrossRefPubMed
5.
Zurück zum Zitat Smith MJ, James S, Pover T, Ball N, Barnetson V, Foster B, Guy C, Rickman J, Walton V (2015) Fantastic plastic? Experimental evaluation of polyurethane bone substitutes as proxies for human bone in trauma simulations. Legal Med 17:427–435CrossRefPubMed Smith MJ, James S, Pover T, Ball N, Barnetson V, Foster B, Guy C, Rickman J, Walton V (2015) Fantastic plastic? Experimental evaluation of polyurethane bone substitutes as proxies for human bone in trauma simulations. Legal Med 17:427–435CrossRefPubMed
6.
Zurück zum Zitat Mahoney PF, Carr DJ, Delaney R, Hunt N, Harrison S, Breeze J, Gibb I (2017) Does preliminary optimisation of an anatomically correct skull-brain model produce clinically realistic ballistic injury fracture patterns? Int J Legal Med 131:1043–1053CrossRefPubMedPubMedCentral Mahoney PF, Carr DJ, Delaney R, Hunt N, Harrison S, Breeze J, Gibb I (2017) Does preliminary optimisation of an anatomically correct skull-brain model produce clinically realistic ballistic injury fracture patterns? Int J Legal Med 131:1043–1053CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Appendix A.10; Ballistics tables (metric system). In: Kneubuehl BP, Coupland RM, Rothschild MA, Thali MJ (2011) (eds) Wound ballistics basics and applications. Springer-Verlag, Berlin Heidelberg pp 366–384 Appendix A.10; Ballistics tables (metric system). In: Kneubuehl BP, Coupland RM, Rothschild MA, Thali MJ (2011) (eds) Wound ballistics basics and applications. Springer-Verlag, Berlin Heidelberg pp 366–384
8.
Zurück zum Zitat Clason DL, Dormody TJ (1994) Analyzing data measured by individual Likert-type items. J Agric Educ 35:31–35CrossRef Clason DL, Dormody TJ (1994) Analyzing data measured by individual Likert-type items. J Agric Educ 35:31–35CrossRef
10.
Zurück zum Zitat Fenton TW, Stefan VH, Wood LA, Sauer NJ (2005) Symmetrical fracturing of the skull from midline contact gunshot wounds: reconstruction of individual death histories from skeletonized human remains. J Forensic Sci 50:1–12CrossRef Fenton TW, Stefan VH, Wood LA, Sauer NJ (2005) Symmetrical fracturing of the skull from midline contact gunshot wounds: reconstruction of individual death histories from skeletonized human remains. J Forensic Sci 50:1–12CrossRef
Metadaten
Titel
Assessment of polyurethane spheres as surrogates for military ballistic head injury
verfasst von
Peter Mahoney
Debra Carr
Nicholas Hunt
Russ J Delaney
Publikationsdatum
29.03.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Legal Medicine / Ausgabe 1/2019
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-018-1832-6

Weitere Artikel der Ausgabe 1/2019

International Journal of Legal Medicine 1/2019 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin