Skip to main content
Erschienen in: International Ophthalmology 1/2020

15.07.2019 | Original Paper

Assessment of tear meniscus by optical coherence tomography in patients with canalicular laceration repair

verfasst von: Seyda Karadenız Ugurlu, Meryem Altın Ekın, Hasan Aytogan

Erschienen in: International Ophthalmology | Ausgabe 1/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To analyze tear meniscus measurements with optical coherence tomography (OCT) in patients with canalicular laceration repair.

Methods

Thirty-four consecutive patients who underwent unilateral canalicular repair due to canalicular laceration between January 2014 and December 2018 were included. All patients had canalicular repair followed by monocanalicular or annular silicone tube intubation. Anatomic patency of canalicular system was tested with probing and irrigation, while functional patency was evaluated with Munk score. Tear meniscus measurements of all patients were obtained following tube removal by spectral OCT. Tear meniscus height (TMH), tear meniscus depth (TMD) and tear meniscus area (TMA) of eyes with canalicular laceration repair and contralateral uninvolved eyes were compared.

Results

Average age of 34 patients was 32.8 ± 21.3 years (range 4–68 years). Lower canaliculus was involved in 27 (79.4%), upper canaliculus in five (14.7%), and both canaliculi in two (5.9%) patients. Mean follow-up period was 6.5 ± 5.7 months. Anatomic patency rate was 100%, and functional patency (patients free of epiphora) was 91.2%. Average TMH (317.9 ± 133.1 µm), TMD (198.1 ± 82.5 µm) and TMA (29,792.1 ± 21,285.3 μm2) values of eyes with canalicular repair were not significantly different from TMH (308.9 ± 111.9 µm), TMD (184.5 ± 61.4 µm) and TMA (26,682.5 ± 16,178.1 μm2) values of contralateral control eyes (p values: 0.758, 0.225 and 0.778, respectively). There was a strong positive correlation between TMA and Munk score (r = 0.637, p < 0.001) and moderate positive correlation between TMH (r = 521, p = 0.002), TMD (r = 0.481, p = 0.004) and Munk score.

Conclusion

Tear meniscus measurement with OCT is a rapid, quantitative and objective tool for evaluation of canalicular patency in patients with canalicular laceration repair.
Literatur
1.
Zurück zum Zitat Han SB, Liu YC, Noriega KM, Mehta JS (2016) Applications of anterior segment optical coherence tomography in cornea and ocular surface diseases. J Ophthalmol 2016:4971572PubMedPubMedCentral Han SB, Liu YC, Noriega KM, Mehta JS (2016) Applications of anterior segment optical coherence tomography in cornea and ocular surface diseases. J Ophthalmol 2016:4971572PubMedPubMedCentral
2.
Zurück zum Zitat Ibrahim OMA, Dogru M, Takano Y, Satake Y, Wakamatsu TH, Fukagawa K et al (2010) Application of visante optical coherence tomography tear meniscus height measurement in the diagnosis of dry eye disease. Ophthalmology 117:1923–1929CrossRef Ibrahim OMA, Dogru M, Takano Y, Satake Y, Wakamatsu TH, Fukagawa K et al (2010) Application of visante optical coherence tomography tear meniscus height measurement in the diagnosis of dry eye disease. Ophthalmology 117:1923–1929CrossRef
3.
Zurück zum Zitat Zhou S, Li Y, Lu ATH et al (2009) Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study. Ophthalmic Surg Laser Imaging 40:442–447CrossRef Zhou S, Li Y, Lu ATH et al (2009) Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study. Ophthalmic Surg Laser Imaging 40:442–447CrossRef
4.
Zurück zum Zitat Nguyen P, Huang D, Li Y, Liu P, Tang M, Yiu SC et al (2012) Correlation between optical coherence tomography-derived assessments of lower tear meniscus parameters and clinical features of dry eye disease. Cornea 31:680–685CrossRef Nguyen P, Huang D, Li Y, Liu P, Tang M, Yiu SC et al (2012) Correlation between optical coherence tomography-derived assessments of lower tear meniscus parameters and clinical features of dry eye disease. Cornea 31:680–685CrossRef
5.
Zurück zum Zitat Akiyama R, Usui T, Yamagami S (2015) Diagnosis of dry eye by tear meniscus measurements using anterior segments swept source optical coherence tomography. Cornea 34:115–120CrossRef Akiyama R, Usui T, Yamagami S (2015) Diagnosis of dry eye by tear meniscus measurements using anterior segments swept source optical coherence tomography. Cornea 34:115–120CrossRef
6.
Zurück zum Zitat Qiu X, Gong L, Sun X, Jin H (2011) Age-related variations of human tear meniscus and diagnosis of dry eye with fourier-domain anterior segment optical coherence tomography. Cornea 30:543–549CrossRef Qiu X, Gong L, Sun X, Jin H (2011) Age-related variations of human tear meniscus and diagnosis of dry eye with fourier-domain anterior segment optical coherence tomography. Cornea 30:543–549CrossRef
7.
Zurück zum Zitat Johnson ME, Murphy PJ (2005) The agreement and repeatability of tear meniscus height measurement methods. Optom Vis Sci 82:1030–1037CrossRef Johnson ME, Murphy PJ (2005) The agreement and repeatability of tear meniscus height measurement methods. Optom Vis Sci 82:1030–1037CrossRef
8.
Zurück zum Zitat Eroglu FC, Karalezli A, Dursun R (2016) Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea? Eye 30:545–552CrossRef Eroglu FC, Karalezli A, Dursun R (2016) Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea? Eye 30:545–552CrossRef
9.
Zurück zum Zitat Baek J, Doh SH, Chung SK (2015) Assessment of the tear meniscus using optical coherence tomography in patients with type 2 diabetes mellitus. Cornea 34:1534–1540CrossRef Baek J, Doh SH, Chung SK (2015) Assessment of the tear meniscus using optical coherence tomography in patients with type 2 diabetes mellitus. Cornea 34:1534–1540CrossRef
10.
Zurück zum Zitat Park DI, Lew H, Lee SY (2012) Tear meniscus measurement in nasolacrimal duct obstruction patients with Fourier-domain optical coherence tomography: novel three-point capture method. Acta Ophthalmol 90:783–787CrossRef Park DI, Lew H, Lee SY (2012) Tear meniscus measurement in nasolacrimal duct obstruction patients with Fourier-domain optical coherence tomography: novel three-point capture method. Acta Ophthalmol 90:783–787CrossRef
11.
Zurück zum Zitat Czajkowski G, Kaluzny BJ, Laudencka A, Malukiewicz G, Kaluzny JJ (2012) Tear meniscus measurement by spectral optical coherence tomography. Optom Vis Sci 89:336–342CrossRef Czajkowski G, Kaluzny BJ, Laudencka A, Malukiewicz G, Kaluzny JJ (2012) Tear meniscus measurement by spectral optical coherence tomography. Optom Vis Sci 89:336–342CrossRef
12.
Zurück zum Zitat García-Resúa C, Santodomingo-Rubido J, Lira M, Giraldez MJ, Vilar EY (2009) Clinical assessment of the lower tear meniscus height. Ophthalmic Physiol Opt 29:487–496CrossRef García-Resúa C, Santodomingo-Rubido J, Lira M, Giraldez MJ, Vilar EY (2009) Clinical assessment of the lower tear meniscus height. Ophthalmic Physiol Opt 29:487–496CrossRef
13.
Zurück zum Zitat Adhi M, Duker JS (2013) Optical coherence tomography—current and future applications. Curr Opin Ophthalmol 24:213–221CrossRef Adhi M, Duker JS (2013) Optical coherence tomography—current and future applications. Curr Opin Ophthalmol 24:213–221CrossRef
14.
Zurück zum Zitat Chen F, Shen M, Chen W, Wang J, Li M, Yuan Y et al (2010) Tear meniscus volume in dry eye after punctual occlusion. Invest Ophthalmol Vis Sci 51:1965–1969CrossRef Chen F, Shen M, Chen W, Wang J, Li M, Yuan Y et al (2010) Tear meniscus volume in dry eye after punctual occlusion. Invest Ophthalmol Vis Sci 51:1965–1969CrossRef
15.
Zurück zum Zitat Roh JH, Chi MJ (2010) Efficacy of dye disappearance test and tear meniscus height in diagnosis and postoperative assessment of nasolacrimal duct obstruction. Acta Ophthalmol 88:73–77CrossRef Roh JH, Chi MJ (2010) Efficacy of dye disappearance test and tear meniscus height in diagnosis and postoperative assessment of nasolacrimal duct obstruction. Acta Ophthalmol 88:73–77CrossRef
16.
Zurück zum Zitat Ohtomo K, Ueta T, Fukuda R, Usui T, Miyai T, Shirakawa R et al (2014) Tear meniscus volume changes in dacryocystorhinostomy evaluated with quantitative measurement using anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci 55:2057–2061CrossRef Ohtomo K, Ueta T, Fukuda R, Usui T, Miyai T, Shirakawa R et al (2014) Tear meniscus volume changes in dacryocystorhinostomy evaluated with quantitative measurement using anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci 55:2057–2061CrossRef
17.
Zurück zum Zitat Kim SE, Lee SJ, Lee SY, Yoon JS (2012) Outcomes of 4-snip punctoplasty for severe punctal stenosis: measurement of tear meniscus height by optical coherence tomography. Am J Ophthalmol 153:769–773CrossRef Kim SE, Lee SJ, Lee SY, Yoon JS (2012) Outcomes of 4-snip punctoplasty for severe punctal stenosis: measurement of tear meniscus height by optical coherence tomography. Am J Ophthalmol 153:769–773CrossRef
18.
Zurück zum Zitat Munk PL, Lin DT, Morris DC (1990) Epiphora: treatment by means of dacryocystoplasty with balloon dilation of the nasolacrimal drainage apparatus. Radiology 177:687–690CrossRef Munk PL, Lin DT, Morris DC (1990) Epiphora: treatment by means of dacryocystoplasty with balloon dilation of the nasolacrimal drainage apparatus. Radiology 177:687–690CrossRef
19.
Zurück zum Zitat Shen M, Li J, Wang J, Ma H, Cai C, Tao A et al (2009) Upper and lower tear menisci in the diagnosis of dry eye. Invest Ophthalmol Vis Sci 50:2722–2726CrossRef Shen M, Li J, Wang J, Ma H, Cai C, Tao A et al (2009) Upper and lower tear menisci in the diagnosis of dry eye. Invest Ophthalmol Vis Sci 50:2722–2726CrossRef
20.
Zurück zum Zitat Schneider CA, Rasband WS, Eliceiri KW (2012) NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9:671–675CrossRef Schneider CA, Rasband WS, Eliceiri KW (2012) NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9:671–675CrossRef
21.
Zurück zum Zitat Savini G, Prabhawasat P, Kojima T, Grueterich M, Espana E, Goto E (2008) The challenge of dry eye diagnosis. Clin Ophthalmol 2:31–55CrossRef Savini G, Prabhawasat P, Kojima T, Grueterich M, Espana E, Goto E (2008) The challenge of dry eye diagnosis. Clin Ophthalmol 2:31–55CrossRef
22.
Zurück zum Zitat O’Donnell B, Shah R (2001) Dacryocystorhinostomy for epiphora in the presence of a patent lacrimal system. Clin Exp Ophthalmol 29:27–29CrossRef O’Donnell B, Shah R (2001) Dacryocystorhinostomy for epiphora in the presence of a patent lacrimal system. Clin Exp Ophthalmol 29:27–29CrossRef
23.
Zurück zum Zitat At’kova EL, Yartsev VD, Krakhovetskiy NN, Root AO, Reyn DA (2016) Use of optical coherence tomography based lacrimal meniscometry in dacryology. Vestn Ophthalmol 132:101–107 At’kova EL, Yartsev VD, Krakhovetskiy NN, Root AO, Reyn DA (2016) Use of optical coherence tomography based lacrimal meniscometry in dacryology. Vestn Ophthalmol 132:101–107
Metadaten
Titel
Assessment of tear meniscus by optical coherence tomography in patients with canalicular laceration repair
verfasst von
Seyda Karadenız Ugurlu
Meryem Altın Ekın
Hasan Aytogan
Publikationsdatum
15.07.2019
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 1/2020
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-019-01147-z

Weitere Artikel der Ausgabe 1/2020

International Ophthalmology 1/2020 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.