Skip to main content
Erschienen in: Journal of Ophthalmic Inflammation and Infection 1/2016

Open Access 01.12.2016 | Original research

Assessment of vitreous haze using ultra-wide field retinal imaging

verfasst von: Drew Dickson, Aniruddha Agarwal, Mohammad Ali Sadiq, Muhammad Hassan, Robin High, Quan Dong Nguyen, Yasir J. Sepah

Erschienen in: Journal of Ophthalmic Inflammation and Infection | Ausgabe 1/2016

Abstract

Background

Conventional fundus imaging has been used to assess vitreous haze (VH) in patients with uveitis. Ultra-wide field (UWF) retinal imaging that uses scanning laser technology has not been evaluated for the detection of VH. This pilot study evaluates the ability of UWF imaging in detecting VH.
Patients with intermediate, posterior, or panuveitis were examined to assess the level of VH using slit-lamp biomicroscopy. Colored fundus images were acquired using a Carl Zeiss FF450 camera. The same photographer obtained fundus images of the same eyes during the same visit by Optos UWF P200Tx retinal camera. Two graders independently analyzed UWF fundus images for presence or absence of VH, without quantifying the degree of VH using any scale. The images were analyzed using the composite red plus red-free wavelengths utilized by the Optos UWF camera and by using each wavelength exclusively. These findings were compared to clinical detection of VH and detection of VH using conventional fundus photography.

Results

Ninety-two eyes were included in the study. For composite UWF images, sensitivity was 0.27, specificity was 0.88, PPV was 0.31, NPV was 0.86, positive LR was 2.25, and negative LR was 0.83. For the conventional Zeiss images, sensitivity was 0.5, specificity was 0.84, PPV was 0.33, NPV was 0.91, positive LR was 3.13, and negative LR was 0.6.
Agreement between the composite UWF and Zeiss techniques was substantial with k = 0.64. Inter-observer agreement for composite UWF images was also substantial with k = 0.65. Inter-observer agreement for Zeiss images was moderate with k = 0.471. Intra-observer agreement for both imaging modalities was substantial with a composite UWF k = 0.76 and Zeiss k = 0.7.

Conclusions

UWF fundus imaging using scanning laser technique may be used to assess VH and employed in the management of intermediate, posterior, and panuveitis.
Abkürzungen
FA
Fluorescein angiography
LR
Likelihood ratio
NEI
National Eye Institute
NPV
Negative predictive value
PPV
Positive predictive value
SLO
Scanning laser ophthalmoscopy
SUN
Standardization of Uveitis Nomenclature
UWF
Ultra-wide field
VH
Vitreous haze

Background

Uveitis is a group of inflammatory ocular conditions that may cause significant visual impairment. Recent estimates suggest that uveitis causes between 5 and 20 % of legal blindness in the USA and Europe and up to 25 % of blindness in the developing world [1]. Protein exudates and inflammatory cells in yes with uveitis distort a clear view of the fundus and cause vitreous haze (VH) [2]. Therefore, detecting and grading vitreous haze is important for patient management and has been approved by the United States Food and Drug Administration (US-FDA) as an outcome measure for clinical trials in uveitis [37].
Fundus imaging using conventional color photographs is commonly used to assess VH in patients with uveitis. A five-step scale of VH based upon ophthalmoscopic clarity of the fundus was proposed by Kimura and associates in 1959 [8]. A six-step scale of VH was created at the National Eye Institute (NEI) in 1985 [9]. This scale was approved by the Standardization of Uveitis Nomenclature (SUN) Working Group in 2005 as an acceptable method of grading VH in clinical research [10]. A nine-step ordinal scale was recently designed by Davis et al. for grading VH [11].
While VH grading of conventional fundus photographs has been validated and standardized, it only provides a 30° field of view. Ultra-wide field (UWF) retinal imaging using scanning laser technology provides a field of view of approximately 200°, which covers 82 % of the retina in a single image [12, 13]. Due to the superior ability of UWF imaging in visualizing the peripheral retina, it has been reported to aid in the management of several posterior segment disorders including uveitis [1317]. A prospective study by Campbell et al. suggested that using UWF imaging and fluorescein angiography (FA) might alter the clinical management of patients with posterior non-infectious uveitis [14].
UWF imaging has not been evaluated for the detection of VH due to the belief that lasers can penetrate media opacities such as cataracts, vitreous hemorrhage, and inflammation and therefore cannot effectively measure VH [18]. However, given the increasing application of UWF imaging and its ability to aid in the management of patients with uveitis, it is important to explore the ability of UWF imaging to identify vitreous haze. This prospective pilot study aims to determine if UWF imaging is able to identify vitreous haze.

Methods

Image acquisition and analysis

Patients diagnosed with intermediate, posterior, or panuveitis at a tertiary eye care center were examined with slit-lamp biomicroscopy to assess the level of VH using the NEI scale. Since the study aimed at determining the ability of UWF imaging in detecting VH, patients with no or only mild VH (≤2+ VH) were included in the study. Colored fundus images (30°, standard 2 M field) were acquired during each patient visit using Carl Zeiss FF450N (Carl Zeiss Meditech, Dublin, CA) camera. An Optos UWF 200° retinal camera (Optos P200Tx, Optos, Scotland, UK) that uses green (532 nm) and red (633 nm) lasers was also used to obtain fundus images of the same eyes during the same patient visit by a single photographer. The eyes with significant cataract, hemorrhage, corneal opacity, and poor cooperation for photography were excluded.
Two graders were masked to the clinical data and independently analyzed UWF fundus images on a single computer monitor for presence or absence of VH, without quantifying the degree of VH using any scale. They did this for composite red plus red-free images and for exclusively red or red-free images. The graders then analyzed the conventional fundus images obtained from the Zeiss camera for the presence or absence of VH, again without quantifying the degree of VH using any scale. These images were analyzed again in the same manner by the first grader 1 month later. A third grader, masked to the clinical data, independently analyzed the UWF and Zeiss images the first two graders disagreed upon to serve as a tie-breaker in order to perform the statistical evaluation. The findings were then compared to the gold standard, i.e., clinical examination, to measure the ability of the UWF technique to detect VH.

Statistical evaluation

Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and positive and negative likelihood ratios (LR) for both the UWF and Zeiss imaging techniques in detecting VH were calculated. An agreement between the two imaging techniques, inter-observer agreement, and intra-observer agreement in detecting VH were calculated using the weighted kappa statistic to account for any random chance in agreement. An adjusted inter-observer agreement was also determined by awarding agreement between the two graders for all images that had a clinical grade of 0 or 0.5+ VH. A 95 % confidence interval was calculated for each kappa value. The kappa measure lies on a scale from −1 to 1, where negative values represent agreement less than chance, 0 represents agreement no more than chance, and 1 represents perfect agreement [19]. A commonly used scale designates a k value of 0.01–0.20 as slight agreement, 0.21–0.40 as fair agreement, 0.41–0.60 as moderate agreement, 0.61–0.80 as substantial agreement, and 0.81–0.99 as almost perfect agreement [20].

Results

Images from 92 eyes (47 patients) were analyzed. Six Zeiss images were not of sufficient quality and were not used in the kappa calculations of intra- and inter-observer agreement of Zeiss image analysis or agreement between the UWF and Zeiss images. All of the non-gradable images had no clinical VH. All of the composite UWF images and red-free images were gradable, while three of the red-only images were not of sufficient quality and disregarded for the calculations. One of these three red-only images had clinical VH. Eighty of the 92 eyes had no clinically detectable VH. Five eyes had 0.5+ VH, four eyes had 1+ VH, one eye had 1.5+ VH, and two eyes had 2+ VH on clinical examination using the NEI scale. None of the eyes included in the analysis had grade 3+ or 4+ VH. The mean clinical VH of the eyes with active uveitis was 1+ on the NEI scale.
In comparing the UWF imaging and the conventional Zeiss photographs to the clinical VH assessment, the sensitivity was 0.27 and 0.5 for Optos UWF and conventional photographs, respectively. Specificity was 0.88 for Optos UWF and 0.84 for conventional photographs. The PPV was 0.31 and 0.33, while the NPV was 0.86 and 0.91 for Optos UWF and conventional photographs, respectively. The positive LR was 2.25 and the negative LR was 0.83 for Optos UWF, whereas the positive LR was 3.13 and the negative LR was 0.6 for conventional photographs. For the red-only UWF images, the sensitivity was 0.50, specificity was 0.853, PPV was 0.353, NPV was 0.914, positive LR was 3.4, and negative LR was 0.531. For the red-free UWF images, the sensitivity was 0.417, specificity was 0.857, PPV was 0.313, NPV was 0.904, positive LR was 2.92, and negative LR was 0.68. These results are summarized in Table 1. Figure 1 provides comparison of the composite Optos UWF and Zeiss techniques in the eyes with and without VH, while Fig. 2 provides comparison between the red-only Optos UWF and red-free Optos UWF imaging techniques in the eyes with and without VH.
Table 1
Statistical evaluation of vitreous haze detection (clinical haze present in 12 eyes)
Statistical measure
Composite UWF images (haze + in 9 eyes)
Red-only UWF images (haze + in 17 eyes)
Red-free UWF images (haze + in 16 eyes)
Conventional Zeiss images (haze + in 16 eyes)
Sensitivity
0.27
0.50
0.42
0.50
Specificity
0.88
0.85
0.86
0.84
PPV
0.31
0.35
0.31
0.33
NPV
0.86
0.91
0.90
0.91
Positive LR
2.25
3.40
2.92
3.13
Negative LR
0.83
0.53
0.68
0.60
UWF ultra-wide field imaging, PPV positive predictive value, NPV negative predictive value, LR likelihood ratio
The agreement between the composite UWF and Zeiss techniques was substantial with the agreement on 76/86 eyes (88.4 %) and k = 0.64 (95 % CI 0.44–0.84). The agreement between the composite UWF and red-only UWF images was moderate with the agreement on 75/87 eyes (86.2 %) and k = 0.49 (95 % CI 0.25–0.74). Substantial agreement was observed between the composite UWF and red-free UWF images in detecting VH with agreement on 80/88 eyes (90.9 %) and k = 0.64 (95 % CI 0.41–0.87). There was substantial agreement between the two observers for detection of VH using composite Optos UWF images with agreement on 83/92 eyes (90.2 %) and a k = 0.65 (95 % CI 0.45–0.86). Red-only inter-observer agreement was substantial with agreement on 78/86 eyes (90.7 %) and k = 0.66 (95 % CI 0.45–0.88). Red-free inter-observer agreement was moderate with agreement on 79/90 eyes (87.8 %) with k = 0.58 (95 % CI 0.36–0.79). For the Zeiss technique, there was agreement on 67/86 eyes (77.9 %) and a modest k = 0.47 (95 % CI 0.27–0.67).
There was near-perfect agreement for all imaging modalities using the adjusted inter-observer agreement. Agreement occurred on 91/92 eyes (97.8 %) with a k = 0.95 (95 % CI 0.85–1.0) for the composite UWF technique. For the red-only UWF images, agreement occurred on 83/86 eyes (96.5 %) with a k = 0.85, and for the red-free UWF images, agreement occurred on 89/90 eyes (98.9 %) with a k = 0.95. Likewise, the Zeiss technique had near-perfect agreement for the adjusted inter-observer agreement with agreement on 84/86 eyes (97.7 %) with a k = 0.94 (95 % CI 0.85–1.0). Intra-observer agreement for the composite UWF images was substantial with agreement on 86/92 eyes (93.5 %) and k = 0.76. Similarly, substantial intra-observer agreement was observed for the red-only UWF images with agreement on 80/86 eyes (93.0 %) and k = 0.75 (95 % CI 0.56–0.94). The red-free UWF intra-observer agreement was near-perfect with agreement on 86/90 eyes (95.6 %) and k = 0.81 (95 % CI 0.63–0.99). Intra-observer agreement for conventional images was substantial with agreement on 77/88 eyes (87.5 %) and k = 0.70 (Fig. 3).

Discussion

Detecting and grading VH is important for both patient care and as an outcome measure in clinical trials for patients with uveitis. The NEI scale and new nine-step scale developed by Davis et al. have demonstrated adequate ability to detect and grade VH in a reproducible manner, but with some limitations. Likewise, the results of this study indicate that UWF imaging may be used to assess VH and be employed in the management of patients with uveitis with some limitations as well.
The results of this pilot study suggest that UWF using SLO does indeed detect VH similar to conventional imaging techniques despite the belief that SLO may pierce through opacities caused by inflammation [18]. Similar results were observed in a recent study by Keane et al. in which spectral domain optical coherence tomography (SD-OCT), which also uses scanning laser technology, was used to assess and quantify VH based on the reflectivity pattern [21]. Keane et al. demonstrated that SD-OCT may be used as an objective measure to quantify VH [21]. In SLO, the emitted laser wavefront is composed of coherent light (spatial and temporal) allowing it to be focused at a tight spot and cover great distances. Properties of diffraction physics apply to laser waves much like visible light. Thus, protein exudates and inflammatory cells may scatter the incident laser beams albeit with a different pattern, resulting in detection of VH. Although both the NEI and Davis scales have shown to provide sufficient reproducibility, the growing use and benefits of UWF imaging in the management of patients with uveitis makes it important to evaluate its ability to detect VH. This study did not intend to develop a scale for UWF grading of VH since it first needs to be determined if UWF can detect VH. Sensitivity, specificity, PPV, NPV, and positive and negative LR using composite, red-only, and red-free UWF imaging were similar to the values seen with conventional imaging (Table 1). It is worth emphasizing here that all UWF images and conventional photographs demonstrated poor sensitivity in detecting haze but good specificity (Table 1).
The inter-observer agreement with composite UWF imaging (k = 0.65) was substantial, while inter-observer agreement with Zeiss (k = 0.47) was moderate. Additionally, both the red-only UWF (k = 0.66) and red-free UWF (k = 0.58) inter-observer agreements were higher than the Zeiss inter-observer agreement. This suggests that UWF imaging may provide a less ambiguous assessment of VH than conventional imaging. When compared to the composite UWF image analysis, the red-only and red-free UWF images did not differ much in terms of their reproducibility. Red-only images had better inter-observer agreement, while red-only images had better intra-observer agreement. A comparison of the inter-observer agreements for the composite UWF and Zeiss images in this study with inter-observer agreements in the Kempen, Davis, and Hornbeak studies can be seen in Fig. 4.
It should be noted that the calculation of the kappa statistic for this study differed from the calculation of kappa in the Davis study. For this study, kappa was calculated based on the graders’ analysis of haze being present or absent and not on haze gradation. In the Davis study, kappa was determined by giving credit for both exact inter-observer agreement and inter-observer agreement within one haze grade [11]. In the index study, if one grader thought there was no VH (0 VH in the Davis scale) and the other thought there was slight VH (1+ VH on the Davis scale), no credit would be given for agreement. This accounts for the discrepancy in the kappa values for inter-observer agreement of conventional images in this study (k = 0.47) versus the average kappa value for inter-observer agreement in the Davis study (k = 0.91). Although kappa was not calculated for exact inter-observer agreement in the Davis study, the exact agreement between the graders only occurred 48 ± 7.6 % of the time [11]. Exact agreement occurred on 77.9 % of images for this study. In the Hornbeak study, kappa was reported for exact inter-observer agreement for the six- and nine-step scales, with an average k = 0.46 and 0.40, respectively [22]. This is similar to the inter-observer agreement for conventional images seen in this study (k = 0.47). The adjusted inter-observer agreement calculated for this study, which awarded agreement for images that had clinical grade of 0 or 0.5+ VH, represents a kappa calculation method more similar to that used by Davis et al. This adjusted agreement had a k value for both the UWF and Zeiss imaging modalities (k = 0.95 and 0.94, respectively) that was much closer to the k value (k = 0.91) for the average inter-observer agreement in the Davis study [11].
It is relevant to note that while a substantial agreement has been found between conventional and UWF imaging in detecting VH, these imaging modalities cannot be used interchangeably during the follow-up imaging of patients with uveitis. In addition, visibility of the retinal nerve fiber layer (RNFL) and the posterior pole is an important parameter in detecting and grading VH in the eyes with uveitis. Compared to UWF imaging, conventional imaging may provide images with better detailing of the posterior pole and RNFL.
While UWF imaging appears to be effective at detecting VH, this study has limitations. This study was performed at a single tertiary care center, which may cause sampling bias. The results of this study also need to be validated. Furthermore, quantification of haze was not performed. Although UWF imaging appears to be useful in detecting VH, it remains unknown if UWF imaging can adequately allow for VH grading. The results of the index study cannot provide details of the ability of UWF imaging in quantifying VH among patients with uveitis. The majority of the disagreement between the graders occurred on the eyes that either had no clinical haze present or mild VH, indicating that UWF imaging may be poor at detecting low levels of VH. Additionally, UWF imaging needs to be validated for detecting haze in the presence of cataracts, hemorrhage, and other corneal opacities. Future studies will need to assess the ability of UWF imaging in accurately and reproducibly grading VH.

Conclusions

The results of this study suggest that UWF imaging may be used to detect VH. With the growing use and benefits of UWF imaging, the ability to assess VH using UWF images may help management of patients with uveitis more efficient and effective.

Authors’ contributions

DD, AA, RH, YJS, and QDN participated in the study design. DD, AA, MAS, and MH analyzed the UWF and conventional photographs. QDN performed the clinical assessment of VH. DD, AA, MAS, YJS, and QDN managed, analyzed, and interpreted the data. DD, AA, and YJS prepared, reviewed, and approved the manuscript. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.
This prospective study was approved by the University of Nebraska Medical Center Institutional Review Board and conducted at the Ocular Imaging Research and Reading Center (OIRRC) of the Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center (Omaha, Nebraska, USA). The study adhered to the tenets established in the Declaration of Helsinki. Informed consent was obtained from all individual participants included in the study.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Literatur
1.
Zurück zum Zitat Miserocchi E, Fogliato G, Modorati G, Bandello F (2013) Review on the worldwide epidemiology of uveitis. Eur J Ophthalmol 23:705–717CrossRefPubMed Miserocchi E, Fogliato G, Modorati G, Bandello F (2013) Review on the worldwide epidemiology of uveitis. Eur J Ophthalmol 23:705–717CrossRefPubMed
3.
Zurück zum Zitat Lowder C, Belfort R, Lightman S et al (2011) Dexamethasone intravitreal implant for noninfectious intermediate or posterior uveitis. Arch Ophthalmol 129:545–553CrossRefPubMed Lowder C, Belfort R, Lightman S et al (2011) Dexamethasone intravitreal implant for noninfectious intermediate or posterior uveitis. Arch Ophthalmol 129:545–553CrossRefPubMed
4.
Zurück zum Zitat Bodaghi B, Gendron G, Wechsler B et al (2007) Efficacy of interferon alpha in the treatment of refractory and sight threatening uveitis: a retrospective monocentric study of 45 patients. Br J Ophthalmol 91:335–339CrossRefPubMed Bodaghi B, Gendron G, Wechsler B et al (2007) Efficacy of interferon alpha in the treatment of refractory and sight threatening uveitis: a retrospective monocentric study of 45 patients. Br J Ophthalmol 91:335–339CrossRefPubMed
5.
Zurück zum Zitat Markomichelakis N, Delicha E, Masselos S, Sfikakis PP (2012) Intravitreal infliximab for sight-threatening relapsing uveitis in Beçhet disease: a pilot study in 15 patients. Am J Ophthalmol 154:534–541CrossRefPubMed Markomichelakis N, Delicha E, Masselos S, Sfikakis PP (2012) Intravitreal infliximab for sight-threatening relapsing uveitis in Beçhet disease: a pilot study in 15 patients. Am J Ophthalmol 154:534–541CrossRefPubMed
6.
Zurück zum Zitat Nguyen QD, Ibrahim MA, Watters A et al (2013) Ocular tolerability and efficacy of intravitreal and subconjunctival injections of sirolimus in patients with non-infectious uveitis: primary 6-month results of the SAVE study. J Ophthalmic Inflamm Infect 3:32CrossRefPubMedPubMedCentral Nguyen QD, Ibrahim MA, Watters A et al (2013) Ocular tolerability and efficacy of intravitreal and subconjunctival injections of sirolimus in patients with non-infectious uveitis: primary 6-month results of the SAVE study. J Ophthalmic Inflamm Infect 3:32CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Dick AD, Tugal-Tutkun I, Foster S et al (2013) Secukinumab in the treatment of noninfectious uveitis: results of three randomized, controlled clinical trials. Ophthalmology 120:777–787CrossRefPubMed Dick AD, Tugal-Tutkun I, Foster S et al (2013) Secukinumab in the treatment of noninfectious uveitis: results of three randomized, controlled clinical trials. Ophthalmology 120:777–787CrossRefPubMed
8.
Zurück zum Zitat Kimura SJ, Thygeson P, Hogan MJ (1959) Signs and symptoms of uveitis. II. Classification of the posterior manifestations of uveitis. Am J Opthalmol 47:171–176CrossRef Kimura SJ, Thygeson P, Hogan MJ (1959) Signs and symptoms of uveitis. II. Classification of the posterior manifestations of uveitis. Am J Opthalmol 47:171–176CrossRef
9.
Zurück zum Zitat Nussenblatt RB, Palestine AG, Chan CC, Roberge F (1985) Standardization of vitreal inflammatory activity in intermediate and posterior uveitis. Ophthalmology 92:467–471CrossRefPubMed Nussenblatt RB, Palestine AG, Chan CC, Roberge F (1985) Standardization of vitreal inflammatory activity in intermediate and posterior uveitis. Ophthalmology 92:467–471CrossRefPubMed
10.
Zurück zum Zitat Standardization of Uveitis Nomenclature (SUN) Working Group (2005) Standardization of uveitis nomenclature for reporting clinical data. Results of the first international workshop. Am J Ophthalmol 140:509–516CrossRef Standardization of Uveitis Nomenclature (SUN) Working Group (2005) Standardization of uveitis nomenclature for reporting clinical data. Results of the first international workshop. Am J Ophthalmol 140:509–516CrossRef
12.
Zurück zum Zitat Manivannan A, Plskova J, Farrow A et al (2005) Ultra-wide-field fluorescein angiography of the ocular fundus. Am J Ophthalmol 140:525–527CrossRefPubMed Manivannan A, Plskova J, Farrow A et al (2005) Ultra-wide-field fluorescein angiography of the ocular fundus. Am J Ophthalmol 140:525–527CrossRefPubMed
13.
Zurück zum Zitat Patel M, Kiss S (2014) Ultra-wide-field fluorescein angiography in retinal disease. Curr Opin Ophthalmol 25:213–220CrossRefPubMed Patel M, Kiss S (2014) Ultra-wide-field fluorescein angiography in retinal disease. Curr Opin Ophthalmol 25:213–220CrossRefPubMed
14.
Zurück zum Zitat Campbell JP, Leder HA, Sepah YJ et al (2012) Wide-field retinal imaging in the management of noninfectious posterior uveitis. Am J Ophthalmol 154:908–911CrossRefPubMed Campbell JP, Leder HA, Sepah YJ et al (2012) Wide-field retinal imaging in the management of noninfectious posterior uveitis. Am J Ophthalmol 154:908–911CrossRefPubMed
15.
Zurück zum Zitat Leder HA, Campbell JP, Sepah YJ et al (2013) Wide-field retinal imaging in the management of noninfectious retinal vasculitis. J Ophthalmic Inflamm Infect 3:1–6CrossRef Leder HA, Campbell JP, Sepah YJ et al (2013) Wide-field retinal imaging in the management of noninfectious retinal vasculitis. J Ophthalmic Inflamm Infect 3:1–6CrossRef
16.
Zurück zum Zitat Tsui I, Kaines A, Schwarts S (2009) Patterns of periphlebitis in intermediate uveitis using ultra wide field fluorescein angiography. Semin Ophthalmol 24:29–33CrossRefPubMed Tsui I, Kaines A, Schwarts S (2009) Patterns of periphlebitis in intermediate uveitis using ultra wide field fluorescein angiography. Semin Ophthalmol 24:29–33CrossRefPubMed
17.
Zurück zum Zitat Kaines A, Tsui I, Sarraf D et al (2009) The use of ultra wide field fluorescein angiography in evaluation and management of uveitis. Semin Ophthalmol 24:19–24CrossRefPubMed Kaines A, Tsui I, Sarraf D et al (2009) The use of ultra wide field fluorescein angiography in evaluation and management of uveitis. Semin Ophthalmol 24:19–24CrossRefPubMed
18.
Zurück zum Zitat Holz FG, Spaide RF (2010) Medical Retina: Focus on Retinal Imaging. Springer, HeidelbergCrossRef Holz FG, Spaide RF (2010) Medical Retina: Focus on Retinal Imaging. Springer, HeidelbergCrossRef
19.
Zurück zum Zitat Viera AJ, Garrett JM (2005) Understanding interobserver agreement: the kappa statistic. Family Med 37:360–363 Viera AJ, Garrett JM (2005) Understanding interobserver agreement: the kappa statistic. Family Med 37:360–363
20.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
21.
Zurück zum Zitat Keane PA, Karmpelas M, Sim DA et al (2014) Objective measurement of vitreous inflammation using optical coherence tomography. Ophthalmology 121:1709–1714 Keane PA, Karmpelas M, Sim DA et al (2014) Objective measurement of vitreous inflammation using optical coherence tomography. Ophthalmology 121:1709–1714
22.
Zurück zum Zitat Hornbeak DM, Payal A, Pistilli M et al (2014) Interobserver agreement in clinical grading of vitreous haze using alternative grading scales. Ophthalmology 121:1643–1648CrossRefPubMedPubMedCentral Hornbeak DM, Payal A, Pistilli M et al (2014) Interobserver agreement in clinical grading of vitreous haze using alternative grading scales. Ophthalmology 121:1643–1648CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Kempen JH, Ganesh SK, Virender SS, Rathinam SR (2008) Interobserver agreement in grading activity and site of inflammation in eyes of patients with uveitis. Am J Ophthalmol 146:813–818CrossRefPubMed Kempen JH, Ganesh SK, Virender SS, Rathinam SR (2008) Interobserver agreement in grading activity and site of inflammation in eyes of patients with uveitis. Am J Ophthalmol 146:813–818CrossRefPubMed
Metadaten
Titel
Assessment of vitreous haze using ultra-wide field retinal imaging
verfasst von
Drew Dickson
Aniruddha Agarwal
Mohammad Ali Sadiq
Muhammad Hassan
Robin High
Quan Dong Nguyen
Yasir J. Sepah
Publikationsdatum
01.12.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Journal of Ophthalmic Inflammation and Infection / Ausgabe 1/2016
Elektronische ISSN: 1869-5760
DOI
https://doi.org/10.1186/s12348-016-0105-0

Weitere Artikel der Ausgabe 1/2016

Journal of Ophthalmic Inflammation and Infection 1/2016 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Open Access 22.02.2024 | Peeling | Originalien

Selektive Vitalfarbstoffe in der Makulachirurgie

Erhöhen sie die Wahrscheinlichkeit der intraoperativen ILM-Identifizierung auch bei einem erfahrenen Operateur?

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.